Evaluation of Fisher Information Matrix-Based Methods for Fast Assessment of Image Quality in Pinhole SPECT.

Abstract:

:The accurate determination of the local impulse response and the covariance in voxels from penalized maximum likelihood reconstructed images requires performing reconstructions from many noise realizations of the projection data. As this is usually a very time-consuming process, efficient analytical approximations based on the Fisher information matrix (FIM) have been extensively used in PET and SPECT to estimate these quantities. For 3D imaging, however, additional approximations need to be made to the FIM in order to speed up the calculations. The most common approach is to use the local shift-invariant (LSI) approximation of the FIM, but this assumes specific conditions which are not always necessarily valid. In this paper we take a single-pinhole SPECT system and compare the accuracy of the LSI approximation against two other methods that have been more recently put forward: the non-uniform object-space pixelation (NUOP) and the subsampled FIM. These methods do not assume such restrictive conditions while still increasing the speed of the calculations considerably. Our results indicate that in pinhole SPECT the NUOP and subsampled FIM approaches could be more reliable than the LSI approximation, especially when a high accuracy is required.

journal_name

IEEE Trans Med Imaging

authors

Pato LR,Vandenberghe S,Vandeghinste B,Van Holen R

doi

10.1109/TMI.2015.2410342

subject

Has Abstract

pub_date

2015-09-01 00:00:00

pages

1830-42

issue

9

eissn

0278-0062

issn

1558-254X

journal_volume

34

pub_type

杂志文章
  • Computer-Aided Cervical Cancer Diagnosis Using Time-Lapsed Colposcopic Images.

    abstract::Cervical cancer causes the fourth most cancer-related deaths of women worldwide. Early detection of cervical intraepithelial neoplasia (CIN) can significantly increase the survival rate of patients. In this paper, we propose a deep learning framework for the accurate identification of LSIL+ (including CIN and cervical...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2020.2994778

    authors: Li Y,Chen J,Xue P,Tang C,Chang J,Chu C,Ma K,Li Q,Zheng Y,Qiao Y

    更新日期:2020-11-01 00:00:00

  • Co-registration of white matter tractographies by adaptive-mean-shift and Gaussian mixture modeling.

    abstract::In this paper, we present a robust approach to the registration of white matter tractographies extracted from diffusion tensor-magnetic resonance imaging scans. The fibers are projected into a high dimensional feature space based on the sequence of their 3-D coordinates. Adaptive mean-shift clustering is applied to ex...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2009.2029097

    authors: Zvitia O,Mayer A,Shadmi R,Miron S,Greenspan HK

    更新日期:2010-01-01 00:00:00

  • Improved methods to determine optimal currents in electrical impedance tomography.

    abstract::An electrical impedance tomography (EIT) system that uses the optimal current method to inject currents and the regularized Newton-Raphson algorithm to reconstruct an image of resistivity distribution is discussed. Iterative methods to derive the optimal current patterns through iterative physical measurements are dev...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.192684

    authors: Hua P,Woo EJ,Webster JG,Tompkins WJ

    更新日期:1992-01-01 00:00:00

  • Spatiotemporal forward solution of the EEG and MEG using network modeling.

    abstract::Dynamic systems have proven to be well suited to describe a broad spectrum of human coordination behavior such synchronization with auditory stimuli. Simultaneous measurements of the spatiotemporal dynamics of electroencephalographic (EEG) and magnetoencephalographic (MEG) data reveals that the dynamics of the brain s...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2002.1009385

    authors: Jirsa VK,Jantzen KJ,Fuchs A,Kelso JA

    更新日期:2002-05-01 00:00:00

  • Automatic correction of motion artifacts in magnetic resonance images using an entropy focus criterion.

    abstract::We present the use of an entropy focus criterion to enable automatic focusing of motion corrupted magnetic resonance images. We demonstrate the principle using illustrative examples from cooperative volunteers. Our technique can determine unknown patient motion or use knowledge of motion from other measures as a start...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.650886

    authors: Atkinson D,Hill DL,Stoyle PN,Summers PE,Keevil SF

    更新日期:1997-12-01 00:00:00

  • Corrections to "Direct Patlak Reconstruction From Dynamic PET Data Using the Kernel Method With MRI Information Based on Structural Similarity".

    abstract::In the above paper [1], there are typos in Algorithm 1 table. The correct version of Algorithm 1 is given below. ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章,已发布勘误

    doi:10.1109/TMI.2018.2849798

    authors: Gong K,Cheng-Liao J,Wang G,Chen KT,Catana C,Qi J

    更新日期:2018-08-01 00:00:00

  • Accuracy of the morphology enabled dipole inversion (MEDI) algorithm for quantitative susceptibility mapping in MRI.

    abstract::Determining the susceptibility distribution from the magnetic field measured in a magnetic resonance (MR) scanner is an ill-posed inverse problem, because of the presence of zeroes in the convolution kernel in the forward problem. An algorithm called morphology enabled dipole inversion (MEDI), which incorporates spati...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2011.2182523

    authors: Liu T,Xu W,Spincemaille P,Avestimehr AS,Wang Y

    更新日期:2012-03-01 00:00:00

  • Unified bundling and registration of brain white matter fibers.

    abstract::Magnetic resonance diffusion tensor imaging is being widely used to reconstruct brain white matter fiber tracts. To characterize structural properties of the tracts, reconstructed fibers are often grouped into bundles that correspond to coherent anatomic structures. For further group analysis of fiber bundles, it is d...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2009.2016337

    authors: Xu Q,Anderson AW,Gore JC,Ding Z

    更新日期:2009-09-01 00:00:00

  • Spatio-temporal fMRI analysis using Markov random fields.

    abstract::Functional magnetic resonance images (fMRI's) provide high-resolution datasets which allow researchers to obtain accurate delineation and sensitive detection of activation areas involved in cognitive processes. To preserve the resolution of this noninvasive technique, refined methods are required in the analysis of th...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.746636

    authors: Descombes X,Kruggel F,von Cramon DY

    更新日期:1998-12-01 00:00:00

  • Two iterative image restoration algorithms with applications to nuclear medicine.

    abstract::Two methods for recovering an image that has been degraded while being processed are presented. The restoration problem is formulated as a constrained optimization problem in which a measure of smoothness based on the second derivatives of the restored image is maximized subject to the constraint that noise energy is ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.126904

    authors: Charalambous C,Ghaddar FK,Kouris K

    更新日期:1992-01-01 00:00:00

  • Learning Domain Shift in Simulated and Clinical Data: Localizing the Origin of Ventricular Activation From 12-Lead Electrocardiograms.

    abstract::Building a data-driven model to localize the origin of ventricular activation from 12-lead electrocardiograms (ECG) requires addressing the challenge of large anatomical and physiological variations across individuals. The alternative of a patient-specific model is, however, difficult to implement in clinical practice...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2018.2880092

    authors: Alawad M,Wang L

    更新日期:2019-05-01 00:00:00

  • Improved SPECT quantitation using fully three-dimensional iterative spatially variant scatter response compensation.

    abstract::The quality and quantitative accuracy of iteratively reconstructed SPECT images improves when better point spread function (PSF) models of the gamma camera are used during reconstruction. Here, inclusion in the PSF model of photon crosstalk between different slices caused by limited gamma camera resolution and scatter...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.511752

    authors: Beekman FJ,Kamphuis C,Viergever MA

    更新日期:1996-01-01 00:00:00

  • PORTR: Pre-operative and post-recurrence brain tumor registration.

    abstract::We propose a new method for deformable registration of pre-operative and post-recurrence brain MR scans of glioma patients. Performing this type of intra-subject registration is challenging as tumor, resection, recurrence, and edema cause large deformations, missing correspondences, and inconsistent intensity profiles...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2013.2293478

    authors: Kwon D,Niethammer M,Akbari H,Bilello M,Davatzikos C,Pohl KM

    更新日期:2014-03-01 00:00:00

  • GPU-based real-time volumetric ultrasound image reconstruction for a ring array.

    abstract::Synthetic phased array (SPA) beamforming with Hadamard coding and aperture weighting is an optimal option for real-time volumetric imaging with a ring array, a particularly attractive geometry in intracardiac and intravascular applications. However, the imaging frame rate of this method is limited by the immense compu...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2013.2253117

    authors: Choe JW,Nikoozadeh A,Oralkan O,Khuri-Yakub BT

    更新日期:2013-07-01 00:00:00

  • Spatial-resolution enhancement in computed tomography.

    abstract::We propose an approach that combines an asymmetric fan-beam configuration and a new reconstruction algorithm to enhancing spatial resolution in computed tomography (CT). The asymmetric configuration can be achieved by changing the center of rotation (COR) from the conventional symmetric configuration. It does not, how...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/tmi.2004.840846

    authors: Pan X,Yu L,Kao CM

    更新日期:2005-02-01 00:00:00

  • Automatic Segmentation of Wrist Bones in CT Using a Statistical Wrist Shape + Pose Model.

    abstract::Segmentation of the wrist bones in CT images has been frequently used in different clinical applications including arthritis evaluation, bone age assessment and image-guided interventions. The major challenges include non-uniformity and spongy textures of the bone tissue as well as narrow inter-bone spaces. In this wo...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2016.2529500

    authors: Anas EM,Rasoulian A,Seitel A,Darras K,Wilson D,John PS,Pichora D,Mousavi P,Rohling R,Abolmaesumi P

    更新日期:2016-08-01 00:00:00

  • Three-dimensional PET emission scan registration and transmission scan synthesis.

    abstract::The duration of a positron emission tomography (PET) imaging scan can be reduced if the transmission scan of one patient which is used for emission correction can be synthesized by using the reference transmission scan of another patient. In this paper, we propose a new intersubjects PET emission scan registration met...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.640744

    authors: Huang CL,Chang WT,Wu LC,Wang JK

    更新日期:1997-10-01 00:00:00

  • Simulation of the expected performance of a seamless scanner for brain PET based on highly pixelated CdTe detectors.

    abstract::The aim of this work is the evaluation of the design for a nonconventional PET scanner, the voxel imaging PET (VIP), based on pixelated room-temperature CdTe detectors yielding a true 3-D impact point with a density of 450 channels/cm(3), for a total 6 336 000 channels in a seamless ring shaped volume. The system is s...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2013.2284657

    authors: Mikhaylova E,De Lorenzo G,Chmeissani M,Kolstein M,Cañadas M,Arce P,Calderón Y,Uzun D,Ariño G,Macias-Montero JG,Martinez R,Puigdengoles C,Cabruja E

    更新日期:2014-02-01 00:00:00

  • A fast Bayesian reconstruction algorithm for emission tomography with entropy prior converging to feasible images.

    abstract::The development and tests of an iterative reconstruction algorithm for emission tomography based on Bayesian statistical concepts are described. The algorithm uses the entropy of the generated image as a prior distribution, can be accelerated by the choice of an exponent, and converges uniformly to feasible images by ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.56340

    authors: Nunez J,Llacer J

    更新日期:1990-01-01 00:00:00

  • Improved Sensitivity in Ultrasound Molecular Imaging With Coherence-Based Beamforming.

    abstract::Ultrasound molecular imaging (USMI) is accomplished by detecting microbubble (MB) contrast agents that have bound to specific biomarkers, and can be used for a variety of imaging applications, such as the early detection of cancer. USMI has been widely utilized in preclinical imaging in mice; however, USMI in humans c...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2017.2774814

    authors: Hyun D,Abou-Elkacem L,Perez VA,Chowdhury SM,Willmann JK,Dahl JJ

    更新日期:2018-01-01 00:00:00

  • Framing U-Net via Deep Convolutional Framelets: Application to Sparse-View CT.

    abstract::X-ray computed tomography (CT) using sparse projection views is a recent approach to reduce the radiation dose. However, due to the insufficient projection views, an analytic reconstruction approach using the filtered back projection (FBP) produces severe streaking artifacts. Recently, deep learning approaches using l...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2018.2823768

    authors: Han Y,Ye JC

    更新日期:2018-06-01 00:00:00

  • Automated segmentation of multiple sclerosis lesions by model outlier detection.

    abstract::This paper presents a fully automated algorithm for segmentation of multiple sclerosis (MS) lesions from multispectral magnetic resonance (MR) images. The method performs intensity-based tissue classification using a stochastic model for normal brain images and simultaneously detects MS lesions as outliers that are no...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.938237

    authors: Van Leemput K,Maes F,Vandermeulen D,Colchester A,Suetens P

    更新日期:2001-08-01 00:00:00

  • EMS-Net: A Deep Learning Method for Autodetecting Epileptic Magnetoencephalography Spikes.

    abstract::Epilepsy is a neurological disorder characterized by sudden and unpredictable epileptic seizures, which incurs significant negative impacts on patients' physical, psychological and social health. A practical approach to assist with the clinical assessment and treatment planning for patients is to process magnetoenceph...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2019.2958699

    authors: Zheng L,Liao P,Luo S,Sheng J,Teng P,Luan G,Gao JH

    更新日期:2020-06-01 00:00:00

  • Bayesian approach for a robust speed-of-sound reconstruction using pulse-echo ultrasound.

    abstract::Computed ultrasound tomography in echo mode (CUTE) is a promising ultrasound (US) based multi-modal technique that allows to image the spatial distribution of speed of sound (SoS) inside tissue using hand-held pulse-echo US. It is based on measuring the phase shift of echoes when detected under varying steering angles...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2020.3029286

    authors: Stahli PS,Frenz M,Jaeger M

    更新日期:2020-10-07 00:00:00

  • Development of a Mechanical Scanning Device With High-Frequency Ultrasound Transducer for Ultrasonic Capsule Endoscopy.

    abstract::Wireless capsule endoscopy has opened a new era by enabling remote diagnostic assessment of the gastrointestinal tract in a painless procedure. Video capsule endoscopy is currently commercially available worldwide. However, it is limited to visualization of superficial tissue. Ultrasound (US) imaging is a complementar...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2017.2699973

    authors: Wang X,Seetohul V,Chen R,Zhang Z,Qian M,Shi Z,Yang G,Mu P,Wang C,Huang Z,Zhou Q,Zheng H,Cochran S,Qiu W

    更新日期:2017-09-01 00:00:00

  • A rapid look-up table method for reconstructing MR images from arbitrary K-space trajectories.

    abstract::Look-up tables (LUTs) are a common method for increasing the speed of many algorithms. Their use can be extended to the reconstruction of nonuniformly sampled k-space data using either a discrete Fourier transform (DFT) algorithm or a convolution-based gridding algorithm. A table for the DFT would be precalculated arr...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.918471

    authors: Dale B,Wendt M,Duerk JL

    更新日期:2001-03-01 00:00:00

  • New perspectives on the sources of white matter DTI signal.

    abstract::A minimalist numerical model of white matter is presented, the objective of which is to help provide a biological basis for improved diffusion tensor imaging (DTI) analysis. Water diffuses, relaxes, and exchanges in three compartments-intracellular, extracellular, and myelin sheath. Exchange between compartments is de...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2007.906787

    authors: Peled S

    更新日期:2007-11-01 00:00:00

  • Objective Detection of Eloquent Axonal Pathways to Minimize Postoperative Deficits in Pediatric Epilepsy Surgery using Diffusion Tractography and Convolutional Neural Networks.

    abstract::Convolutional neural networks (CNNs) have recently been used in biomedical imaging applications with great success. In this paper, we investigated the classi?cation performance of CNN models on diffusion weighted imaging (DWI) streamlines de?ned by functional MRI (fMRI) and electrical stimulation mapping (ESM). To lea...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2019.2902073

    authors: Xu H,Dong M,Lee MH,OrHara N,Asano E,Jeong JW

    更新日期:2019-02-27 00:00:00

  • Implementation, investigation, and improvement of a novel cone-beam reconstruction method [SPECT].

    abstract::A three-dimensional reconstruction method which uses cone-beam data was implemented. Issues concerning implementation are investigated and discussed in detail. Computer simulations were used to determine the amount of image degradation occurring in each of the three steps that comprise the reconstruction method. In ad...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.141650

    authors: Smith BD,Chen J

    更新日期:1992-01-01 00:00:00

  • The GEM MAP algorithm with 3-D SPECT system response.

    abstract::In single photon emission computed tomography (SPECT), every reconstruction algorithm must use some model for the response of the gamma camera to emitted gamma-rays. The true camera response is both spatially variant and object dependent. These two properties result from the effects of scatter, septal penetration, and...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.126914

    authors: Hebert TJ,Gopal SS

    更新日期:1992-01-01 00:00:00