Abstract:
:The reconstruction of MR quantitative susceptibility mapping (QSM) from local phase measurements is an ill posed inverse problem and different regularization strategies incorporating a priori information extracted from magnitude and phase images have been proposed. However, the anatomy observed in magnitude and phase images does not always coincide spatially with that in susceptibility maps, which could give erroneous estimation in the reconstructed susceptibility map. In this paper, we develop a structural feature based collaborative reconstruction (SFCR) method for QSM including both magnitude and susceptibility based information. The SFCR algorithm is composed of two consecutive steps corresponding to complementary reconstruction models, each with a structural feature based l 1 norm constraint and a voxel fidelity based l 2 norm constraint, which allows both the structure edges and tiny features to be recovered, whereas the noise and artifacts could be reduced. In the M-step, the initial susceptibility map is reconstructed by employing a k -space based compressed sensing model incorporating magnitude prior. In the S-step, the susceptibility map is fitted in spatial domain using weighted constraints derived from the initial susceptibility map from the M-step. Simulations and in vivo human experiments at 7T MRI show that the SFCR method provides high quality susceptibility maps with improved RMSE and MSSIM. Finally, the susceptibility values of deep gray matter are analyzed in multiple head positions, with the supine position most approximate to the gold standard COSMOS result.
journal_name
IEEE Trans Med Imagingjournal_title
IEEE transactions on medical imagingauthors
Bao L,Li X,Cai C,Chen Z,van Zijl PCdoi
10.1109/TMI.2016.2544958subject
Has Abstractpub_date
2016-09-01 00:00:00pages
2040-50issue
9eissn
0278-0062issn
1558-254Xjournal_volume
35pub_type
杂志文章abstract::High peak RF amplitude and excessive specific absorption rate (SAR) are two critical concerns for hardware implementation and patient safety in scientific and clinical research for high field MRI using parallel transmissions (pTX). In this paper, we introduce a squeezing strategy to reduce peak RF amplitude and integr...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2018.2828112
更新日期:2018-08-01 00:00:00
abstract::Delay-and-sum (DAS) beamforming is unable to identify individual scatterers when their density is so high that their point spread functions overlap. This paper proposes a convolutional neural network (CNN)-based method to detect and localize high-density scatterers, some of which are closer than the resolution limit o...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2020.3006445
更新日期:2020-12-01 00:00:00
abstract::The most frequent extracranial solid tumors of childhood, named peripheral neuroblastic tumors (pNTs), are very challenging to diagnose due to their diversified categories and varying forms. Auxiliary diagnosis methods of such pediatric malignant cancers are highly needed to provide pathologists assistance and reduce ...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2020.3027547
更新日期:2021-01-01 00:00:00
abstract::This paper addresses the long object problem in helical cone-beam computed tomography. We present the PHI-method, a new algorithm for the exact reconstruction of a region-of-interest (ROI) of a long object from axially truncated data extending only slightly beyond the ROI. The PHI-method is an extension of the Radon-m...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.870247
更新日期:2000-05-01 00:00:00
abstract::Two methods for recovering an image that has been degraded while being processed are presented. The restoration problem is formulated as a constrained optimization problem in which a measure of smoothness based on the second derivatives of the restored image is maximized subject to the constraint that noise energy is ...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.126904
更新日期:1992-01-01 00:00:00
abstract::Motivated by the goals of improving detection of low-contrast and narrow vessels and eliminating false detections at nonvascular structures, a new technique is presented for extracting vessels in retinal images. The core of the technique is a new likelihood ratio test that combines matched-filter responses, confidence...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/tmi.2006.884190
更新日期:2006-12-01 00:00:00
abstract::In this paper, we are interested in soft tissue differentiation by multiband images obtained from the High-Resolution Ultrasonic Transmission Tomography (HUTT) system using a spectral target detection method based on constrained energy minimization (CEM). We have developed a new tissue differentiation method (called "...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/tmi.2004.843179
更新日期:2005-03-01 00:00:00
abstract::Online acquisition of Cherenkov and portal imaging data was combined with a reconstruction scheme called EC3-D, providing a full 3-D dosimetry of megavoltage X-ray beams in a water tank. The methodology was demonstrated and quantified in a single static beam. Furthermore, the dynamics and visualization of the 3-D dose...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2017.2717800
更新日期:2017-10-01 00:00:00
abstract::Regularization is desirable for image reconstruction in emission tomography. A powerful regularization method is the penalized-likelihood (PL) reconstruction algorithm (or equivalently, maximum a posteriori reconstruction), where the sum of the likelihood and a noise suppressing penalty term (or Bayesian prior) is opt...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2003.816960
更新日期:2003-09-01 00:00:00
abstract::Microcalcifications can be one of the earliest signs of breast cancer. Unfortunately, their appearance in mammograms can be mimicked by dust and dirt entering the imaging process and this has been shown previously to lead to false positives. We use a model of the imaging process and, in particular, the blurring functi...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.811313
更新日期:1999-10-01 00:00:00
abstract::Cone beam X-ray luminescence computed tomography (CB-XLCT) is a promising imaging technique in studying the physiological and pathological processes in small animals. However, the dynamic bio-distributions of probes in small animal, especially in adjacent targets are still hard to be captured directly from dynamic CB-...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2019.2917026
更新日期:2019-12-01 00:00:00
abstract::In positron emission tomography (PET) image reconstruction, the Bayesian framework with various regularization terms has been implemented to constrain the radio tracer distribution. Varying the regularizing weight of a maximum a posteriori (MAP) algorithm specifies a lower bound of the tradeoff between variance and sp...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2018.2803681
更新日期:2018-06-01 00:00:00
abstract::A new class of acquisition schemes for helical cone-beam computed tomography (CB-CT) scanning is introduced, and their effect on the reconstruction methods is analyzed. These acquisition schemes are based on a new detector shape that is bounded by the helix. It will be shown that the data acquired with these schemes a...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.887834
更新日期:2000-09-01 00:00:00
abstract::Lung cancer is the leading cause of cancer deaths worldwide and early diagnosis of lung nodule is of great importance for therapeutic treatment and saving lives. Automated lung nodule analysis requires both accurate lung nodule benign-malignant classification and attribute score regression. However, this is quite chal...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2019.2934577
更新日期:2020-03-01 00:00:00
abstract::Magnetic resonance imaging (MRI) on patients with implanted deep brain stimulators (DBSs) can be hazardous because of the antenna-effect of leads exposed to the incident radio-frequency field. This study evaluated electromagnetic field and specific absorption rate (SAR) changes as a function of lead resistivity on an ...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2010.2040624
更新日期:2010-04-01 00:00:00
abstract::A special-purpose hardware architecture is proposed to implement the expectation-maximization algorithm to compute, in clinically useful times, the maximum-likelihood estimate of a radionuclide distribution for a positron-emission tomogram from time-of-flight measurements. Two-dimensional convolutions required for for...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.14510
更新日期:1988-01-01 00:00:00
abstract::Cerebral ischemic stroke causes injury to brain tissue characterized by a complex cascade of neuronal and vascular events. Imaging during the early stages of its development allows prediction of tissue infarction and penumbra so that optimal intervention can be determined in order to salvage brain function impairment....
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2019.2895779
更新日期:2019-06-01 00:00:00
abstract::This paper presents a fully automated algorithm for segmentation of multiple sclerosis (MS) lesions from multispectral magnetic resonance (MR) images. The method performs intensity-based tissue classification using a stochastic model for normal brain images and simultaneously detects MS lesions as outliers that are no...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.938237
更新日期:2001-08-01 00:00:00
abstract::Inhomogeneities in the transmit radio frequency magnetic field ( ) reduce the quality of magnetic resonance (MR) images. This quality can be improved by using high-permittivity pads that tailor the fields. The design of an optimal pad is application-specific and not straightforward and would therefore benefit from a s...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2018.2791179
更新日期:2018-04-01 00:00:00
abstract::Magnetic Resonance-Electrical Properties Tomography (MR-EPT) is an imaging modality that maps the spatial distribution of the electrical conductivity and permittivity using standard MRI systems. The presence of a body within the scanner alters the RF field, and by mapping these alterations it is possible to recover th...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2015.2466082
更新日期:2016-01-01 00:00:00
abstract::Maximization of mutual information (MMI) is a popular similarity measure for medical image registration. Although its accuracy and robustness has been demonstrated for rigid body image registration, extending MMI to nonrigid image registration is not trivial and an active field of research. We propose conditional mutu...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2009.2021843
更新日期:2010-01-01 00:00:00
abstract::In this paper we present a compressed sensing (CS) method adapted to 3D ultrasound imaging (US). In contrast to previous work, we propose a new approach based on the use of learned overcomplete dictionaries that allow for much sparser representations of the signals since they are optimized for a particular class of im...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2015.2442154
更新日期:2015-12-01 00:00:00
abstract::Most benign breast tumors possess well-defined, sharp boundaries that delineate them from surrounding tissues, as opposed to malignant tumors. Computer techniques proposed to date for tumor analysis have concentrated on shape factors of tumor regions and texture measures. While shape measures based on contours of tumo...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.650876
更新日期:1997-12-01 00:00:00
abstract::Multifrequency electrical impedance tomography (MFEIT) exploits the dependence of tissue impedance on frequency to recover an image of conductivity. MFEIT could provide emergency diagnosis of pathologies such as acute stroke, brain injury and breast cancer. We present a method for performing MFEIT using spectral const...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2013.2284966
更新日期:2014-02-01 00:00:00
abstract::While magnetic particle imaging (MPI) constitutes a novel biomedical imaging technique for tracking superparamagnetic nanoparticles in vivo, unlike magnetic resonance imaging (MRI), it cannot provide anatomical background information. Until now these two modalities have been performed in separate scanners and image co...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2014.2327515
更新日期:2014-10-01 00:00:00
abstract::In this paper, we propose the use of multiscale amplitude-modulation-frequency-modulation (AM-FM) methods for discriminating between normal and pathological retinal images. The method presented in this paper is tested using standard images from the early treatment diabetic retinopathy study. We use 120 regions of 40 x...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2009.2037146
更新日期:2010-02-01 00:00:00
abstract::In traditional transillumination of the breast (diaphanography), the abundance of diffuse light resulting from the use of extended noncollimated sources reduces the visibility of deep seated lesions. A prototype scanning imaging system has been developed to investigate the effectiveness of thin collimated light beams ...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.251126
更新日期:1993-01-01 00:00:00
abstract::A method for fully automated morphological and topological quantification of microvascular structures in confocal laser scanning microscopy (CLSM) volume datasets is presented. Several characteristic morphological and topological quantities are calculated in a series of image-processing steps and can be used to compar...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2007.900379
更新日期:2007-08-01 00:00:00
abstract::Previous work has shown that total variation superiorization (TVS) improves reconstructed image quality in proton computed tomography (pCT). The structure of the TVS algorithm has evolved since then and this paper investigated if this new algorithmic structure provides additional benefits to pCT image quality. Structu...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2019.2911482
更新日期:2020-02-01 00:00:00
abstract::Automatic computer-based methods are well suited for the image analysis of the different components in atherosclerotic plaques. Although several groups work on such analysis some of the methods used are oversimplified and require improvements when used within a computational framework for predicting meaningful stress ...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2006.870485
更新日期:2006-03-01 00:00:00