Exact radon rebinning algorithm for the long object problem in helical cone-beam CT.

Abstract:

:This paper addresses the long object problem in helical cone-beam computed tomography. We present the PHI-method, a new algorithm for the exact reconstruction of a region-of-interest (ROI) of a long object from axially truncated data extending only slightly beyond the ROI. The PHI-method is an extension of the Radon-method, published by Kudo, Noo, and Defrise in issue 43 of journal Physics in Medicine and Biology. The key novelty of the PHI-method is the introduction of a virtual object fpsi(x) for each value of the azimuthal angle psi in the image space, with each virtual object having the property of being equal to the true object f(x) in some ROI omegam. We show that, for each psi, one can calculate exact Radon data corresponding to the two-dimensional (2-D) parallel-beam projection of fpsi(x) onto the meridian plane of angle psi. Given an angular range of length pi of such parallel-beam projections, the ROI omegam can be exactly reconstructed because f(x) is identical to fpsi(x) in Omegam. Simulation results are given for both the Radon-method and the PHI-method indicating that 1) for the case of short objects, the Radon- and PHI-methods produce comparable image quality, 2) for the case of long objects, the PHI-method delivers the same image quality as in the short object case, while the Radon-method fails, and 3) the image quality produced by the PHI-method is similar for a large range of pitch values.

journal_name

IEEE Trans Med Imaging

authors

Schaller S,Sauer F,Tam KC,Lauritsch G,Flohr T

doi

10.1109/42.870247

subject

Has Abstract

pub_date

2000-05-01 00:00:00

pages

361-75

issue

5

eissn

0278-0062

issn

1558-254X

journal_volume

19

pub_type

杂志文章
  • Clustered components analysis for functional MRI.

    abstract::A common method of increasing hemodynamic response (SNR) in functional magnetic resonance imaging (fMRI) is to average signal timecourses across voxels. This technique is potentially problematic because the hemodynamic response may vary across the brain. Such averaging may destroy significant features in the temporal ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2003.819922

    authors: Chen S,Bouman CA,Lowe MJ

    更新日期:2004-01-01 00:00:00

  • Magnetic Particle Imaging: A Resovist Based Marking Technology for Guide Wires and Catheters for Vascular Interventions.

    abstract::Magnetic particle imaging (MPI) is able to provide high temporal and good spatial resolution, high signal to noise ratio and sensitivity. Furthermore, it is a truly quantitative method as its signal strength is proportional to the concentration of its tracer, superparamagnetic iron oxide nanoparticles (SPIOs), over a ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2016.2559538

    authors: Haegele J,Panagiotopoulos N,Cremers S,Rahmer J,Franke J,Duschka RL,Vaalma S,Heidenreich M,Borgert J,Borm P,Barkhausen J,Vogt FM

    更新日期:2016-10-01 00:00:00

  • Prospective Respiration Detection in Magnetic Resonance Imaging by a Non-Interfering Noise Navigator.

    abstract::Passive monitoring of the thermal noise variances of the channels of a receive array was shown to reveal respiratory motion of the underlying anatomy, a so called "noise navigator". There is, however, an inevitable trade off between the accuracy and temporal resolution of the noise navigator due to its passive nature....

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2018.2808699

    authors: Navest RJM,Andreychenko A,Lagendijk JJW,van den Berg CAT

    更新日期:2018-08-01 00:00:00

  • High-Frame-Rate Echocardiography Using Coherent Compounding With Doppler-Based Motion-Compensation.

    abstract::High-frame-rate ultrasonography based on coherent compounding of unfocused beams can potentially transform the assessment of cardiac function. As it requires successive waves to be combined coherently, this approach is sensitive to high-velocity tissue motion. We investigated coherent compounding of tilted diverging w...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2016.2523346

    authors: Poree J,Posada D,Hodzic A,Tournoux F,Cloutier G,Garcia D

    更新日期:2016-07-01 00:00:00

  • A nonparametric method for automatic correction of intensity nonuniformity in MRI data.

    abstract::A novel approach to correcting for intensity nonuniformity in magnetic resonance (MR) data is described that achieves high performance without requiring a model of the tissue classes present. The method has the advantage that it can be applied at an early stage in an automated data analysis, before a tissue model is a...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.668698

    authors: Sled JG,Zijdenbos AP,Evans AC

    更新日期:1998-02-01 00:00:00

  • Simultaneous sparsity model for histopathological image representation and classification.

    abstract::The multi-channel nature of digital histopathological images presents an opportunity to exploit the correlated color channel information for better image modeling. Inspired by recent work in sparsity for single channel image classification, we propose a new simultaneous sparsity model for multi-channel histopathologic...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2014.2306173

    authors: Srinivas U,Mousavi HS,Monga V,Hattel A,Jayarao B

    更新日期:2014-05-01 00:00:00

  • Comments on "A new algorithm for border description of polarized light surface microscopic images of pigmented skin lesions".

    abstract::In this paper, discrepancies and reference inaccuracies in the paper (Grana et al., 2003) are pointed out. Specifically, it is demonstrated that the definitions of "lesion gradient" and "skin lesion gradient," widely used in a number of medical papers on computer analysis of pigmented skin lesions, are unambiguous, an...

    journal_title:IEEE transactions on medical imaging

    pub_type: 评论,信件

    doi:10.1109/tmi.2006.884205

    authors: Burroni M,Alparone L,Argenti F

    更新日期:2006-12-01 00:00:00

  • MDM-PCCT: Multiple Dynamic Modulations for High-Performance Spectral PCCT Imaging.

    abstract::Photon counting computed tomography (PCCT) has the ability to identify individual photons, resulting in quantitative material identification. Meanwhile, several technical challenges still exist in current PCCT imaging systems, including increased noise and suboptimal bin selection. These nonideal effects can substanti...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2020.3001616

    authors: Li D,Zeng D,Li S,Ge Y,Bian Z,Huang J,Ma J

    更新日期:2020-11-01 00:00:00

  • Automated detection of prostatic adenocarcinoma from high-resolution ex vivo MRI.

    abstract::Prostatic adenocarcinoma is the most commonly occurring cancer among men in the United States, second only to skin cancer. Currently, the only definitive method to ascertain the presence of prostatic cancer is by trans-rectal ultrasound (TRUS) directed biopsy. Owing to the poor image quality of ultrasound, the accurac...

    journal_title:IEEE transactions on medical imaging

    pub_type: 临床试验,杂志文章

    doi:10.1109/TMI.2005.859208

    authors: Madabhushi A,Feldman MD,Metaxas DN,Tomaszeweski J,Chute D

    更新日期:2005-12-01 00:00:00

  • Estimating 3-D respiratory motion from orbiting views by tomographic image registration.

    abstract::Respiratory motion remains a significant source of errors in treatment planning for the thorax and upper abdomen. Recently, we proposed a method to estimate two-dimensional (2-D) object motion from a sequence of slowly rotating X-ray projection views, which we called deformation from orbiting views (DOVs). In this met...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2006.889719

    authors: Zeng R,Fessler JA,Balter JM

    更新日期:2007-02-01 00:00:00

  • Flux-based anisotropic diffusion applied to enhancement of 3-D angiogram.

    abstract::We present a new approach to anisotropic diffusion based on a multidirectional diffusion flux. The diffusion flux is decomposed in an orthogonal basis, effectively enabling enhancement of contours as well as diffusion along the contours. To this end, we have selected a three-dimensional basis that depicts the directio...

    journal_title:IEEE transactions on medical imaging

    pub_type: 信件

    doi:10.1109/TMI.2002.806403

    authors: Krissian K

    更新日期:2002-11-01 00:00:00

  • Patch-Based Output Space Adversarial Learning for Joint Optic Disc and Cup Segmentation.

    abstract::Glaucoma is a leading cause of irreversible blindness. Accurate segmentation of the optic disc (OD) and optic cup (OC) from fundus images is beneficial to glaucoma screening and diagnosis. Recently, convolutional neural networks demonstrate promising progress in the joint OD and OC segmentation. However, affected by t...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2019.2899910

    authors: Wang S,Yu L,Yang X,Fu CW,Heng PA

    更新日期:2019-11-01 00:00:00

  • A Kernel-Based Low-Rank (KLR) Model for Low-Dimensional Manifold Recovery in Highly Accelerated Dynamic MRI.

    abstract::While many low rank and sparsity-based approaches have been developed for accelerated dynamic magnetic resonance imaging (dMRI), they all use low rankness or sparsity in input space, overlooking the intrinsic nonlinear correlation in most dMRI data. In this paper, we propose a kernel-based framework to allow nonlinear...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2017.2723871

    authors: Nakarmi U,Wang Y,Lyu J,Liang D,Ying L

    更新日期:2017-11-01 00:00:00

  • EnPiT: filtered back-projection algorithm for helical CT using an n-Pi acquisition.

    abstract::In this paper, we formulate a reconstruction algorithm for an n-Pi acquisition, where n can be any positive odd integer. The algorithm is a generalization of the method presented in (Bontus et al. 2003). It is based on the results obtained by Katsevich (2004). For the algorithm, different sets of filter-lines have to ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2005.850545

    authors: Bontus C,Köhler T,Proksa R

    更新日期:2005-08-01 00:00:00

  • MRI of moving subjects using multislice snapshot images with volume reconstruction (SVR): application to fetal, neonatal, and adult brain studies.

    abstract::Motion degrades magnetic resonance (MR) images and prevents acquisition of self-consistent and high-quality volume images. A novel methodology, Snapshot magnetic resonance imaging (MRI) with Volume Reconstruction (SVR) has been developed for imaging moving subjects at high resolution and high signal-to-noise ratio (SN...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2007.895456

    authors: Jiang S,Xue H,Glover A,Rutherford M,Rueckert D,Hajnal JV

    更新日期:2007-07-01 00:00:00

  • Brachytherapy seed localization using geometric and linear programming techniques.

    abstract::We propose an optimization algorithm to solve the brachytherapy seed localization problem in prostate brachytherapy. Our algorithm is based on novel geometric approaches to exploit the special structure of the problem and relies on a number of key observations which help us formulate the optimization problem as a mini...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2007.900740

    authors: Singh V,Mukherjee L,Xu J,Hoffmann KR,Dinu PM,Podgorsak M

    更新日期:2007-09-01 00:00:00

  • Spatio-Temporal Tensor Decomposition of a Polyaffine Motion Model for a Better Analysis of Pathological Left Ventricular Dynamics.

    abstract::Given that heart disease can cause abnormal motion dynamics over the cardiac cycle, understanding and quantifying cardiac motion can provide insight for clinicians to aid with diagnosis, therapy planning, and determining prognosis. The goal of this paper is to extract population-specific motion patterns from 3D displa...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2015.2405579

    authors: McLeod K,Sermesant M,Beerbaum P,Pennec X

    更新日期:2015-07-01 00:00:00

  • Tracking pylorus in ultrasonic image sequences with edge-based optical flow.

    abstract::Tracking pylorus in ultrasonic image sequences is an important step in the analysis of duodenogastric reflux (DGR). We propose a joint prediction and segmentation method (JPS) which combines optical flow with active contour to track pylorus. The goal of the proposed method is to improve the pyloric tracking accuracy b...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2012.2183884

    authors: Chen C,Wang Y,Yu J,Zhou Z,Shen L,Chen Y

    更新日期:2012-03-01 00:00:00

  • Detecting Cardiovascular Disease from Mammograms With Deep Learning.

    abstract::Coronary artery disease is a major cause of death in women. Breast arterial calcifications (BACs), detected inmammograms, can be useful riskmarkers associated with the disease. We investigate the feasibility of automated and accurate detection ofBACsinmammograms for risk assessment of coronary artery disease. We devel...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2017.2655486

    authors: Wang J,Ding H,Bidgoli FA,Zhou B,Iribarren C,Molloi S,Baldi P

    更新日期:2017-05-01 00:00:00

  • Amplified Flow Imaging (aFlow): A Novel MRI-Based Tool to Unravel the Coupled Dynamics Between the Human Brain and Cerebrovasculature.

    abstract::With each heartbeat, periodic variations in arterial blood pressure are transmitted along the vasculature, resulting in localized deformations of the arterial wall and its surrounding tissue. Quantification of such motions may help understand various cerebrovascular conditions, yet it has proven technically challengin...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2020.3012932

    authors: Abderezaei J,Martinez J,Terem I,Fabris G,Pionteck A,Yang Y,Holdsworth SJ,Nael K,Kurt M

    更新日期:2020-12-01 00:00:00

  • Parameter relations for the Shinnar-Le Roux selective excitation pulse design algorithm [NMR imaging].

    abstract::An overview of the Shinnar-Le Roux (SLR) algorithm is presented. It is shown how the performance of SLR pulses can be very accurately specified analytically. This reveals how to design a pulse that produces a specified slice profile and allows the pulse designer to trade off analytically the parameters describing the ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.75611

    authors: Pauly J,Le Roux P,Nishimura D,Macovski A

    更新日期:1991-01-01 00:00:00

  • Sufficient statistics as a generalization of binning in spectral X-ray imaging.

    abstract::It is well known that the energy dependence of X-ray attenuation can be used to characterize materials. Yet, even with energy discriminating photon counting X-ray detectors, it is still unclear how to best form energy dependent measurements for spectral imaging. Common ideas include binning photon counts based on thei...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2010.2061862

    authors: Wang AS,Pelc NJ

    更新日期:2011-01-01 00:00:00

  • Multi-channel microstrip transceiver arrays using harmonics for high field MR imaging in humans.

    abstract::Radio-frequency (RF) transceiver array design using primary and higher order harmonics for in vivo parallel magnetic resonance imaging imaging (MRI) and spectroscopic imaging is proposed. The improved electromagnetic decoupling performance, unique magnetic field distributions and high-frequency operation capabilities ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2011.2166273

    authors: Wu B,Wang C,Lu J,Pang Y,Nelson SJ,Vigneron DB,Zhang X

    更新日期:2012-02-01 00:00:00

  • Sensitivity of photon-counting based K-edge imaging in X-ray computed tomography.

    abstract::The feasibility of K-edge imaging using energy-resolved, photon-counting transmission measurements in X-ray computed tomography (CT) has been demonstrated by simulations and experiments. The method is based on probing the discontinuities of the attenuation coefficient of heavy elements above and below the K-edge energ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2011.2142188

    authors: Roessl E,Brendel B,Engel KJ,Schlomka JP,Thran A,Proksa R

    更新日期:2011-09-01 00:00:00

  • Restoration of retinal images obtained through cataracts.

    abstract::An optical model for imaging the retina through cataracts has been developed. The images are treated as sample functions of stochastic processes. On the basis of the model a homomorphic Weiner filter can be designed that will optimally restore the cataractous image (in the mean-square-error sense). The design of the f...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.41493

    authors: Peli E,Peli T

    更新日期:1989-01-01 00:00:00

  • Wound status evaluation using color image processing.

    abstract::An accurate diagnosis of burns and pressure ulcers in the early stages can be made by computerized image processing. This study describes a critical assessment of potential methodologies for noninvasive wound evaluation using a color imaging system. We also developed a method for quantifying histological readings and ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.552057

    authors: Hansen GL,Sparrow EM,Kokate JY,Leland KJ,Iaizzo PA

    更新日期:1997-02-01 00:00:00

  • Estimation of the hemodynamic response in event-related functional MRI: Bayesian networks as a framework for efficient Bayesian modeling and inference.

    abstract::A convenient way to analyze blood-oxygen-level-dependent functional magnetic resonance imaging data consists of modeling the whole brain as a stationary, linear system characterized by its transfer function: the hemodynamic response function (HRF). HRF estimation, though of the greatest interest, is still under invest...

    journal_title:IEEE transactions on medical imaging

    pub_type: 临床试验,杂志文章

    doi:10.1109/TMI.2004.831221

    authors: Marrelec G,Ciuciu P,Pélégrini-Issac M,Benali H

    更新日期:2004-08-01 00:00:00

  • Quantification of MR brain images by mixture density and partial volume modeling.

    abstract::The problem of automatic quantification of brain tissue by utilizing single-valued (single echo) magnetic resonance imaging (MRI) brain scans is addressed. It is shown that this problem can be solved without classification or segmentation, a method that may be particularly useful in quantifying white matter lesions wh...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.241885

    authors: Santago P,Gage HD

    更新日期:1993-01-01 00:00:00

  • Unsupervised Deep Learning Applied to Breast Density Segmentation and Mammographic Risk Scoring.

    abstract::Mammographic risk scoring has commonly been automated by extracting a set of handcrafted features from mammograms, and relating the responses directly or indirectly to breast cancer risk. We present a method that learns a feature hierarchy from unlabeled data. When the learned features are used as the input to a simpl...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2016.2532122

    authors: Kallenberg M,Petersen K,Nielsen M,Ng AY,Pengfei Diao,Igel C,Vachon CM,Holland K,Winkel RR,Karssemeijer N,Lillholm M

    更新日期:2016-05-01 00:00:00

  • Segmentation of the optic disc, macula and vascular arch in fundus photographs.

    abstract::An automatic system is presented to find the location of the major anatomical structures in color fundus photographs; the optic disc, the macula, and the vascular arch. These structures are found by fitting a single point-distribution-model to the image, that contains points on each structure. The method can handle op...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2006.885336

    authors: Niemeijer M,Abràmoff MD,van Ginneken B

    更新日期:2007-01-01 00:00:00