MRI of moving subjects using multislice snapshot images with volume reconstruction (SVR): application to fetal, neonatal, and adult brain studies.

Abstract:

:Motion degrades magnetic resonance (MR) images and prevents acquisition of self-consistent and high-quality volume images. A novel methodology, Snapshot magnetic resonance imaging (MRI) with Volume Reconstruction (SVR) has been developed for imaging moving subjects at high resolution and high signal-to-noise ratio (SNR). The method combines registered 2-D slices from sequential dynamic single-shot scans. The SVR approach requires that the anatomy in question is not changing shape or size and is moving at a rate that allows snapshot images to be acquired. After imaging the target volume repeatedly to guarantee sufficient sampling every where, a robust slice-to-volume registration method has been implemented that achieves alignment of each slice within 0.3 mm in the examples tested. Multilevel scattered interpolation has been used to obtain high-fidelity reconstruction with root-mean-square (rms) error that is less than the noise level in the images. The SVR method has been performed successfully for brain studies on subjects that cannot stay still, and in some cases were moving substantially during scanning. For example, awake neonates, deliberately moved adults and, especially, on fetuses, for which no conventional high-resolution 3-D method is currently available. Fine structure of the in-utero fetal brain is clearly revealed for the first time and substantial SNR improvement is realized by having many individually acquired slices contribute to each voxel in the reconstructed image.

journal_name

IEEE Trans Med Imaging

authors

Jiang S,Xue H,Glover A,Rutherford M,Rueckert D,Hajnal JV

doi

10.1109/TMI.2007.895456

subject

Has Abstract

pub_date

2007-07-01 00:00:00

pages

967-80

issue

7

eissn

0278-0062

issn

1558-254X

journal_volume

26

pub_type

杂志文章
  • Increased spatial resolution in transillumination using collimated light.

    abstract::In traditional transillumination of the breast (diaphanography), the abundance of diffuse light resulting from the use of extended noncollimated sources reduces the visibility of deep seated lesions. A prototype scanning imaging system has been developed to investigate the effectiveness of thin collimated light beams ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.251126

    authors: Wist AO,Fatouros PP,Herr SL

    更新日期:1993-01-01 00:00:00

  • Fractal feature analysis and classification in medical imaging.

    abstract::Following B.B. Mandelbrot's fractal theory (1982), it was found that the fractal dimension could be obtained in medical images by the concept of fractional Brownian motion. An estimation concept for determination of the fractal dimension based upon the concept of fractional Brownian motion is discussed. Two applicatio...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.24861

    authors: Chen CC,Daponte JS,Fox MD

    更新日期:1989-01-01 00:00:00

  • Quantifying the statistical impact of GRAPPA in fcMRI data with a real-valued isomorphism.

    abstract::The interpolation of missing spatial frequencies through the generalized auto-calibrating partially parallel acquisitions (GRAPPA) parallel magnetic resonance imaging (MRI) model implies a correlation is induced between the acquired and reconstructed frequency measurements. As the parallel image reconstruction algorit...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2013.2288521

    authors: Bruce IP,Rowe DB

    更新日期:2014-02-01 00:00:00

  • Novel EIS postprocessing algorithm for breast cancer diagnosis.

    abstract::A new postprocessing algorithm was developed for the diagnosis of breast cancer using electrical impedance scanning. This algorithm automatically recognizes bright focal spots in the conductivity map of the breast. Moreover, this algorithm discriminates between malignant and benign/normal tissues using two main predic...

    journal_title:IEEE transactions on medical imaging

    pub_type: 信件

    doi:10.1109/TMI.2002.800605

    authors: Glickman YA,Filo O,Nachaliel U,Lenington S,Amin-Spector S,Ginor R

    更新日期:2002-06-01 00:00:00

  • An image-guided planning system for endosseous oral implants.

    abstract::A preoperative planning system for oral implant surgery was developed which takes as input computed tomographies (CT's) of the jaws. Two-dimensional (2-D) reslices of these axial CT slices orthogonal to a curve following the jaw arch are computed and shown together with three-dimensional (3-D) surface rendered models ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.736056

    authors: Verstreken K,Van Cleynenbreugel J,Martens K,Marchal G,van Steenberghe D,Suetens P

    更新日期:1998-10-01 00:00:00

  • Automated segmentation of multiple sclerosis lesions by model outlier detection.

    abstract::This paper presents a fully automated algorithm for segmentation of multiple sclerosis (MS) lesions from multispectral magnetic resonance (MR) images. The method performs intensity-based tissue classification using a stochastic model for normal brain images and simultaneously detects MS lesions as outliers that are no...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.938237

    authors: Van Leemput K,Maes F,Vandermeulen D,Colchester A,Suetens P

    更新日期:2001-08-01 00:00:00

  • MRF-based deformable registration and ventilation estimation of lung CT.

    abstract::Deformable image registration is an important tool in medical image analysis. In the case of lung computed tomography (CT) registration there are three major challenges: large motion of small features, sliding motions between organs, and changing image contrast due to compression. Recently, Markov random field (MRF)-b...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2013.2246577

    authors: Heinrich MP,Jenkinson M,Brady M,Schnabel JA

    更新日期:2013-07-01 00:00:00

  • The detection and quantification of retinopathy using digital angiograms.

    abstract::An algorithm is presented for the analysis and quantification of the vascular structures of the human retina. Information about retinal blood vessel morphology is used in grading the severity and progression of a number of diseases. These disease processes are typically followed over relatively long time courses, and ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.363106

    authors: Zhou L,Rzeszotarski MS,Singerman LJ,Chokreff JM

    更新日期:1994-01-01 00:00:00

  • Wavelet analysis for brain-function imaging.

    abstract::The authors present a new algorithmic procedure for the analysis of brain images. This procedure is specifically designed to image the activity and functional organization of the brain. The authors' results are tested on data collected and previously analyzed with the technique known as in vivo optical imaging of intr...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.414621

    authors: Carmona RA,Hwang WL,Frostig RD

    更新日期:1995-01-01 00:00:00

  • Regionally adaptive histogram equalization of the chest.

    abstract::Advances in the area of digital chest radiography have resulted in the acquisition of high-quality images of the human chest. With these advances, there arises a genuine need for image processing algorithms specific to the chest, in order to fully exploit this digital technology. We have implemented the well-known tec...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.1987.4307791

    authors: Sherrier RH,Johnson GA

    更新日期:1987-01-01 00:00:00

  • Estimating CT Image From MRI Data Using Structured Random Forest and Auto-Context Model.

    abstract::Computed tomography (CT) imaging is an essential tool in various clinical diagnoses and radiotherapy treatment planning. Since CT image intensities are directly related to positron emission tomography (PET) attenuation coefficients, they are indispensable for attenuation correction (AC) of the PET images. However, due...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2015.2461533

    authors: Huynh T,Gao Y,Kang J,Wang L,Zhang P,Lian J,Shen D,Alzheimer's Disease Neuroimaging Initiative.

    更新日期:2016-01-01 00:00:00

  • Time-frequency MEG-MUSIC algorithm.

    abstract::We propose a method that incorporates the time-frequency characteristics of neural sources into magnetoencephalographic (MEG) source estimation. The method is based on the multiple-signal-classification (MUSIC) algorithm and it calculates a time--frequency matrix in which diagonal and off-diagonal terms are the auto a...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.750262

    authors: Sekihara K,Nagarajan S,Poeppel D,Miyashita Y

    更新日期:1999-01-01 00:00:00

  • Image Registration Based on Low Rank Matrix: Rank-Regularized SSD.

    abstract::Similarity measure is a main core of image registration algorithms. Spatially varying intensity distortion is an important challenge, which affects the performance of similarity measures. Correlation among the pixels is the main characteristic of this distortion. Similarity measures such as sum-of-squared-differences ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2017.2744663

    authors: Ghaffari A,Fatemizadeh E

    更新日期:2018-01-01 00:00:00

  • Adaptive speckle reduction filter for log-compressed B-scan images.

    abstract::A good statistical model of speckle formation is useful for designing a good adaptive filter for speckle reduction In ultrasound B-scan images. Previously, statistical models have been used, but they failed to account for the log compression of the echo envelope employed by clinical ultrasound systems. Log-compression...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.544498

    authors: Dutt V,Greenleaf JF

    更新日期:1996-01-01 00:00:00

  • Improved watershed transform for medical image segmentation using prior information.

    abstract::The watershed transform has interesting properties that make it useful for many different image segmentation applications: it is simple and intuitive, can be parallelized, and always produces a complete division of the image. However, when applied to medical image analysis, it has important drawbacks (oversegmentation...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2004.824224

    authors: Grau V,Mewes AU,Alcañiz M,Kikinis R,Warfield SK

    更新日期:2004-04-01 00:00:00

  • Noise characterization of block-iterative reconstruction algorithms: II. Monte Carlo simulations.

    abstract::In Soares et al. (2000), the ensemble statistical properties of the rescaled block-iterative expectation-maximization (RBI-EM) reconstruction algorithm and rescaled block-iterative simultaneous multiplicative algebraic reconstruction technique (RBI-SMART) were derived. Included in this analysis were the special cases ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/tmi.2004.836876

    authors: Soares EJ,Glick SJ,Hoppin JW

    更新日期:2005-01-01 00:00:00

  • A direct reconstruction algorithm for electrical impedance tomography.

    abstract::A direct (noniterative) reconstruction algorithm for electrical impedance tomography in the two-dimensional (2-D), cross-sectional geometry is reviewed. New results of a reconstruction of a numerically simulated phantom chest are presented. The algorithm is based on the mathematical uniqueness proof by A. I. Nachman [...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2002.800574

    authors: Mueller JL,Siltanen S,Isaacson D

    更新日期:2002-06-01 00:00:00

  • General reconstruction theory for multislice X-ray computed tomography with a gantry tilt.

    abstract::This paper discusses image reconstruction with a tilted gantry in multislice computed tomography (CT) with helical (spiral) data acquisition. The reconstruction problem with gantry tilt is shown to be transformable into the problem of reconstructing a virtual object from multislice CT data with no gantry tilt, for whi...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2004.829337

    authors: Noo F,Defrise M,Kudo H

    更新日期:2004-09-01 00:00:00

  • Deep Geodesic Learning for Segmentation and Anatomical Landmarking.

    abstract::In this paper, we propose a novel deep learning framework for anatomy segmentation and automatic landmarking. Specifically, we focus on the challenging problem of mandible segmentation from cone-beam computed tomography (CBCT) scans and identification of 9 anatomical landmarks of the mandible on the geodesic space. Th...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2018.2875814

    authors: Torosdagli N,Liberton DK,Verma P,Sincan M,Lee JS,Bagci U

    更新日期:2019-04-01 00:00:00

  • Anti-aliased three-dimensional cone-beam reconstruction of low-contrast objects with algebraic methods.

    abstract::This paper examines the use of the algebraic reconstruction technique (ART) and related techniques to reconstruct 3-D objects from a relatively sparse set of cone-beam projections. Although ART has been widely used for cone-beam reconstruction of high-contrast objects, e.g., in computed angiography, the work presented...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.781017

    authors: Mueller K,Yagel R,Wheller JJ

    更新日期:1999-06-01 00:00:00

  • Block-iterative Fisher scoring algorithms for maximum penalized likelihood image reconstruction in emission tomography.

    abstract::This paper introduces and evaluates a block-iterative Fisher scoring (BFS) algorithm. The algorithm provides regularized estimation in tomographic models of projection data with Poisson variability. Regularization is achieved by penalized likelihood with a general quadratic penalty. Local convergence of the block-iter...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2008.918355

    authors: Ma J,Hudson M

    更新日期:2008-08-01 00:00:00

  • Spatial-resolution enhancement in computed tomography.

    abstract::We propose an approach that combines an asymmetric fan-beam configuration and a new reconstruction algorithm to enhancing spatial resolution in computed tomography (CT). The asymmetric configuration can be achieved by changing the center of rotation (COR) from the conventional symmetric configuration. It does not, how...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/tmi.2004.840846

    authors: Pan X,Yu L,Kao CM

    更新日期:2005-02-01 00:00:00

  • A methodology for evaluation of boundary detection algorithms on medical images.

    abstract::Image segmentation is the partition of an image into a set of nonoverlapping regions whose union is the entire image. The image is decomposed into meaningful parts which are uniform with respect to certain characteristics, such as gray level or texture. In this paper, we propose a methodology for evaluating medical im...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.640755

    authors: Chalana V,Kim Y

    更新日期:1997-10-01 00:00:00

  • Structure Prediction for Gland Segmentation With Hand-Crafted and Deep Convolutional Features.

    abstract::We present a novel method to segment instances of glandular structures from colon histopathology images. We use a structure learning approach which represents local spatial configurations of class labels, capturing structural information normally ignored by sliding-window methods. This allows us to reveal different sp...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2017.2750210

    authors: Manivannan S,Li W,Zhang J,Trucco E,McKenna SJ

    更新日期:2018-01-01 00:00:00

  • Feature extraction in carpal-bone analysis.

    abstract::Hand-bone analysis with image processing techniques using a digital radiograph can be used to assess skeletal age. The analysis consists of two steps: phalangeal and carpal bone analysis. The carpal bone analysis is discussed. First, the carpal bone region of interest (CROI) is defined using a standard thresholding te...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.222665

    authors: Pietka E,Kaabi L,Kuo ML,Huang HK

    更新日期:1993-01-01 00:00:00

  • Closing the Gap between Deep Neural Network Modeling and Biomedical Decision-Making Metrics in Segmentation via Adaptive Loss Functions.

    abstract::Deep learning is becoming an indispensable tool for various tasks in science and engineering. A critical step in constructing a reliable deep learning model is the selection of a loss function, which measures the discrepancy between the network prediction and the ground truth. While a variety of loss functions have be...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2020.3031913

    authors: Seo H,Bassenne M,Xing L

    更新日期:2020-10-19 00:00:00

  • Efficient Compressed Sensing SENSE pMRI Reconstruction With Joint Sparsity Promotion.

    abstract::The theory and techniques of compressed sensing (CS) have shown their potential as a breakthrough in accelerating k-space data acquisition for parallel magnetic resonance imaging (pMRI). However, the performance of CS reconstruction models in pMRI has not been fully maximized, and CS recovery guarantees for pMRI are l...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2015.2474383

    authors: Chun IY,Adcock B,Talavage TM

    更新日期:2016-01-01 00:00:00

  • Simultaneous Morphological and Flow Imaging Enabled by Megahertz Intravascular Doppler Optical Coherence Tomography.

    abstract::We demonstrate three-dimensional intravascular flow imaging compatible with routine clinical image acquisition workflow by means of megahertz (MHz) intravascular Doppler Optical Coherence Tomography (OCT). The OCT system relies on a 1.1 mm diameter motorized imaging catheter and a 1.5 MHz Fourier Domain Mode Locked (F...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2019.2948258

    authors: Wang T,Pfeiffer T,Daemen J,Mastik F,Wieser W,van der Steen AFW,Huber R,van Soest G

    更新日期:2020-05-01 00:00:00

  • Accelerating the nonequispaced fast Fourier transform on commodity graphics hardware.

    abstract::We present a fast parallel algorithm to compute the nonequispaced fast Fourier transform on commodity graphics hardware (the GPU). We focus particularly on a novel implementation of the convolution step in the transform as it was previously its most time consuming part. We describe the performance for two common sampl...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2007.909834

    authors: Sorensen TS,Schaeffter T,Noe KO,Hansen MS

    更新日期:2008-04-01 00:00:00

  • Electrical impedance tomography of translationally uniform cylindrical objects with general cross-sectional boundaries.

    abstract::An algorithm is developed for electrical impedance tomography (EIT) of finite cylinders with general cross-sectional boundaries and translationally uniform conductivity distributions. The electrodes for data collection are assumed to be placed around a cross-sectional plane; therefore, the axial variation of the bound...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.52982

    authors: Ider YZ,Gencer NG,Atalar E,Tosun H

    更新日期:1990-01-01 00:00:00