Abstract:
:In this paper, we formulate a reconstruction algorithm for an n-Pi acquisition, where n can be any positive odd integer. The algorithm is a generalization of the method presented in (Bontus et al. 2003). It is based on the results obtained by Katsevich (2004). For the algorithm, different sets of filter-lines have to be defined. We describe the variation of these lines along the detector in some detail, before we discuss, how the method gives all Radon-plane contributions the correct weighting. The different sets of filter-lines are all contained within the n-Pi window, such that a practical realization is possible. Reconstruction results, which we present in the final section, show convincing image quality.
journal_name
IEEE Trans Med Imagingjournal_title
IEEE transactions on medical imagingauthors
Bontus C,Köhler T,Proksa Rdoi
10.1109/TMI.2005.850545subject
Has Abstractpub_date
2005-08-01 00:00:00pages
977-86issue
8eissn
0278-0062issn
1558-254Xjournal_volume
24pub_type
杂志文章abstract::Positron emission tomography (PET) is a useful tool for pharmacokinetics studies in rodents during the preclinical phase of drug and tracer development. However, rodent organs are small as compared to the scanner's intrinsic resolution and are affected by physiological movements. We present a new method for the segmen...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2007.905106
更新日期:2008-03-01 00:00:00
abstract::To avoid the confounding effects of anesthesia and immobilization stress in rat brain positron emission tomography (PET), motion tracking-based unrestrained awake rat brain imaging is being developed. In this paper, we propose a fast and accurate rat headmotion tracking method based on small PET point sources. PET poi...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2017.2667889
更新日期:2017-07-01 00:00:00
abstract::A special-purpose hardware architecture is proposed to implement the expectation-maximization algorithm to compute, in clinically useful times, the maximum-likelihood estimate of a radionuclide distribution for a positron-emission tomogram from time-of-flight measurements. Two-dimensional convolutions required for for...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.14510
更新日期:1988-01-01 00:00:00
abstract::This paper describes several methods for magnetic resonance angiography that create projection images based solely on flowing blood. To both remove static tissue from the image and generate signals from blood, two classes of methods considered are temporal subtraction and cancelling excitation. Temporal subtraction, a...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.1986.4307763
更新日期:1986-01-01 00:00:00
abstract::A novel framework for the classification of acute rejection versus nonrejection status of renal transplants from 2-D dynamic contrast-enhanced magnetic resonance imaging is proposed. The framework consists of four steps. First, kidney objects are segmented from adjacent structures with a level set deformable boundary ...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2013.2269139
更新日期:2013-10-01 00:00:00
abstract::Tracking pylorus in ultrasonic image sequences is an important step in the analysis of duodenogastric reflux (DGR). We propose a joint prediction and segmentation method (JPS) which combines optical flow with active contour to track pylorus. The goal of the proposed method is to improve the pyloric tracking accuracy b...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2012.2183884
更新日期:2012-03-01 00:00:00
abstract::An analysis of the kinetics of myocardial contrast enhancement is an important component of myocardial perfusion studies. The contrast enhancement can be modeled by a linear time-invariant system, and the myocardial impulse response, calculated by deconvolution of the measured tissue response with an arterial input, g...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2004.827969
更新日期:2004-07-01 00:00:00
abstract::Photon counting computed tomography (PCCT) has the ability to identify individual photons, resulting in quantitative material identification. Meanwhile, several technical challenges still exist in current PCCT imaging systems, including increased noise and suboptimal bin selection. These nonideal effects can substanti...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2020.3001616
更新日期:2020-11-01 00:00:00
abstract::Magnetic resonance tagging makes it possible to measure the motion of tissues such as muscles in the heart and tongue. The harmonic phase (HARP) method largely automates the process of tracking points within tagged MR images, permitting many motion properties to be computed. However, HARP tracking can yield erroneous ...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2010.2045509
更新日期:2010-08-01 00:00:00
abstract::A common challenge when performing surface-based registration of images is ensuring that the surfaces accurately represent consistent anatomical boundaries. Image segmentation may be difficult in some regions due to either poor contrast, low slice resolution, or tissue ambiguities. To address this, we present a novel ...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2015.2443978
更新日期:2015-12-01 00:00:00
abstract::A fully automated 2-D+time myocardial segmentation framework is proposed for cardiac magnetic resonance (CMR) blood-oxygen-level-dependent (BOLD) data sets. Ischemia detection with CINE BOLD CMR relies on spatio-temporal patterns in myocardial intensity, but these patterns also trouble supervised segmentation methods,...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2017.2726112
更新日期:2017-11-01 00:00:00
abstract::Glaucoma is a leading cause of irreversible blindness. Accurate segmentation of the optic disc (OD) and optic cup (OC) from fundus images is beneficial to glaucoma screening and diagnosis. Recently, convolutional neural networks demonstrate promising progress in the joint OD and OC segmentation. However, affected by t...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2019.2899910
更新日期:2019-11-01 00:00:00
abstract::Risk stratification (characterization) of tumors from radiology images can be more accurate and faster with computer-aided diagnosis (CAD) tools. Tumor characterization through such tools can also enable non-invasive cancer staging, prognosis, and foster personalized treatment planning as a part of precision medicine....
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2019.2894349
更新日期:2019-08-01 00:00:00
abstract::Strategies for improvement of blood flow by promoting new vessel growth in ischemic tissue are being developed. Recently, contrast-enhanced ultrasound (CEU) imaging has been used to assess tissue perfusion in models of ischemia-related angiogenesis, growth-factor mediated angiogenesis, and tumor angiogenesis. In these...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/tmi.2006.877442
更新日期:2006-08-01 00:00:00
abstract::A method that incorporates a priori uniform or nonuniform source distribution probabilistic information and data fluctuations of a Poisson nature is presented. The source distributions are modeled in terms of a priori source probability density functions. Maximum a posteriori probability solutions, as determined by a ...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.34711
更新日期:1989-01-01 00:00:00
abstract::Echo-planar imaging (EPI) is a fast nuclear magnetic resonance imaging (MRI) method. Unfortunately, local magnetic field inhomogeneities induced mainly by the subject's presence cause significant geometrical distortion, predominantly along the phase-encoding direction, which must be undone to allow for meaningful furt...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.836368
更新日期:2000-02-01 00:00:00
abstract::Optical coherence tomography (OCT) uses retroreflected light to provide micrometer-resolution, cross-sectional scans of biological tissues. OCT's first application was in ophthalmic imaging where it has proven particularly useful in diagnosing, monitoring, and studying glaucoma. Diagnosing glaucoma is difficult and it...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2006.871417
更新日期:2006-05-01 00:00:00
abstract::Ultrasound molecular imaging (USMI) is accomplished by detecting microbubble (MB) contrast agents that have bound to specific biomarkers, and can be used for a variety of imaging applications, such as the early detection of cancer. USMI has been widely utilized in preclinical imaging in mice; however, USMI in humans c...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2017.2774814
更新日期:2018-01-01 00:00:00
abstract::We present a dynamic atlas composed of neuromelanin-enhanced magnetic resonance brain images of 40 healthy subjects. The performance of this atlas is evaluated on the fully automated segmentation of two paired neuromelanin-rich brainstem healthy structures: the substantia nigra pars compacta and the locus coeruleus. W...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2018.2872852
更新日期:2019-03-01 00:00:00
abstract::In this paper we propose a framework for using duplex Doppler ultrasound systems. These type of systems need to interleave the acquisition and display of a B-mode image and of the pulsed Doppler spectrogram. In a recent study (Richy , 2013), we have shown that compressed sensing-based reconstruction of Doppler signal ...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2015.2504240
更新日期:2016-04-01 00:00:00
abstract::This paper examines the use of the algebraic reconstruction technique (ART) and related techniques to reconstruct 3-D objects from a relatively sparse set of cone-beam projections. Although ART has been widely used for cone-beam reconstruction of high-contrast objects, e.g., in computed angiography, the work presented...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.781017
更新日期:1999-06-01 00:00:00
abstract::The accuracy of in vivo dopamine D2 receptor quantification by positron emission tomography (PET) was determined for several models by means of singular-value decomposition, and some of the model assumptions were reviewed. These include steady-state, transient, double injection, and equilibrium approaches. All four mo...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.7783
更新日期:1988-01-01 00:00:00
abstract::The development and tests of an iterative reconstruction algorithm for emission tomography based on Bayesian statistical concepts are described. The algorithm uses the entropy of the generated image as a prior distribution, can be accelerated by the choice of an exponent, and converges uniformly to feasible images by ...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.56340
更新日期:1990-01-01 00:00:00
abstract::Detecting tools in surgical videos is an important ingredient for context-aware computer-assisted surgical systems. To this end, we present a new surgical tool detection dataset and a method for joint tool detection and pose estimation in 2d images. Our two-stage pipeline is data-driven and relaxes strong assumptions ...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2015.2450831
更新日期:2015-12-01 00:00:00
abstract::An automatic system is presented to find the location of the major anatomical structures in color fundus photographs; the optic disc, the macula, and the vascular arch. These structures are found by fitting a single point-distribution-model to the image, that contains points on each structure. The method can handle op...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2006.885336
更新日期:2007-01-01 00:00:00
abstract::In picture archiving and communications systems (PACS), images need to be displayed in standardized ways for radiologists' interpretations. However, for most radiographs acquired via computed radiography (CR), digital radiography (DR), or digitized films, the image orientation is undetermined because of the variations...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/tmi.2006.880677
更新日期:2006-10-01 00:00:00
abstract::True three-dimensional (3-D) volume reconstruction from fully 3-D data in positron emission tomography (PET) has only a limited clinical use because of its large computational burden. Fourier rebinning (FORE) of the fully 3-D data into a set of 2-D sinogram data decomposes the 3-D reconstruction process into multiple ...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.870257
更新日期:2000-05-01 00:00:00
abstract::To improve the quantitative accuracy of linear attenuation coefficients measured by computed tomography (CT), we used a single scatter model to estimate the Compton scatter distribution and then a polychromatic image reconstruction algorithm, namely the iterative maximum-likelihood polychromatic algorithm for CT (IMPA...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2015.2395438
更新日期:2015-06-01 00:00:00
abstract::New biopsy techniques, increased life expectancy, and prostate-specific antigen (PSA) screening have contributed to an increase in the reported incidence of prostate cancer. Among several treatment options available to the patients, transperineal prostate brachytherapy has emerged as a medically successful, cost-effec...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.736032
更新日期:1998-10-01 00:00:00
abstract::Ultra-short TE (UTE) sequences with radial sampling make it possible to visualize tissues with very short T2 decay times. The UTE sequence acquires an echo signal from the central to the outer parts of k-space and is very sensitive to small trajectory errors. Therefore, k-space errors caused by imperfections in the gr...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2012.2226050
更新日期:2013-02-01 00:00:00