Anatomy and flow in normal and ischemic microvasculature based on a novel temporal fractal dimension analysis algorithm using contrast enhanced ultrasound.

Abstract:

:Strategies for improvement of blood flow by promoting new vessel growth in ischemic tissue are being developed. Recently, contrast-enhanced ultrasound (CEU) imaging has been used to assess tissue perfusion in models of ischemia-related angiogenesis, growth-factor mediated angiogenesis, and tumor angiogenesis. In these studies, microvascular flow is measured in order to assess the total impact of adaptations at different vascular levels. High-resolution methods for imaging larger vessels have been developed in order to derive "angiograms" of arteries, veins, and medium to large microvessels. We describe a novel method of vascular bed (microvessel and arterial) characterization of vessel anatomy and flow simultaneously, using serial measurement of the fractal dimension (FD) of a temporal sequence of CEU images. This method is proposed as an experimental methodology to distinguish ischemic from nonischemic tissue. Moreover, an improved approach for extracting the FD unique to this application is introduced.

journal_name

IEEE Trans Med Imaging

authors

Charalampidis D,Pascotto M,Kerut EK,Lindner JR

doi

10.1109/tmi.2006.877442

subject

Has Abstract

pub_date

2006-08-01 00:00:00

pages

1079-86

issue

8

eissn

0278-0062

issn

1558-254X

journal_volume

25

pub_type

杂志文章
  • Reducing the effects of scattered photons in X-ray projection imaging.

    abstract::An iterative algorithm is introduced which can compute and subtract the scatter bias. It is assumed that the scatter-free image is spatially bounded and anything outside the boundary is the result of recorded scattered photons. This information and the fact that the scatter distribution does not have appreciable high-...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.20362

    authors: Fahimi H,Macovski A

    更新日期:1989-01-01 00:00:00

  • Motion-compensated and gated cone beam filtered back-projection for 3-D rotational X-ray angiography.

    abstract::This paper presents a method to reconstruct moving objects from cone beam X-ray projections acquired during a single rotational run using a given motion vector field. The method is applicable to voxel driven cone-beam filtered back-projection reconstruction approaches. Here, a formulation based on the algorithm of Fel...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/tmi.2006.876147

    authors: Schäfer D,Borgert J,Rasche V,Grass M

    更新日期:2006-07-01 00:00:00

  • 3-D reconstruction of tissue components for atherosclerotic human arteries using ex vivo high-resolution MRI.

    abstract::Automatic computer-based methods are well suited for the image analysis of the different components in atherosclerotic plaques. Although several groups work on such analysis some of the methods used are oversimplified and require improvements when used within a computational framework for predicting meaningful stress ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2006.870485

    authors: Auer M,Stollberger R,Regitnig P,Ebner F,Holzapfel GA

    更新日期:2006-03-01 00:00:00

  • Practical considerations for 3-D image reconstruction using spherically symmetric volume elements.

    abstract::Spherically symmetric volume elements with smooth tapering of the values near their boundaries are alternatives to the more conventional voxels for the construction of volume images in the computer. Their use, instead of voxels, introduces additional parameters which enable the user to control the shape of the volume ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.481442

    authors: Matej S,Lewitt RM

    更新日期:1996-01-01 00:00:00

  • Hot spot detection based on feature space representation of visual search.

    abstract::This paper presents a new framework for capturing intrinsic visual search behavior of different observers in image understanding by analysing saccadic eye movements in feature space. The method is based on the information theory for identifying salient image features based on which visual search is performed. We demon...

    journal_title:IEEE transactions on medical imaging

    pub_type: 临床试验,杂志文章

    doi:10.1109/TMI.2003.816959

    authors: Hu XP,Dempere-Marco L,Yang GZ

    更新日期:2003-09-01 00:00:00

  • Simultaneous Analysis of 2D Echo Views for Left Atrial Segmentation and Disease Detection.

    abstract::We propose a joint information approach for automatic analysis of 2D echocardiography (echo) data. The approach combines a priori images, their segmentations and patient diagnostic information within a unified framework to determine various clinical parameters, such as cardiac chamber volumes, and cardiac disease labe...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2016.2593900

    authors: Allan G,Nouranian S,Tsang T,Seitel A,Mirian M,Jue J,Hawley D,Fleming S,Gin K,Swift J,Rohling R,Abolmaesumi P

    更新日期:2017-01-01 00:00:00

  • A fast Bayesian reconstruction algorithm for emission tomography with entropy prior converging to feasible images.

    abstract::The development and tests of an iterative reconstruction algorithm for emission tomography based on Bayesian statistical concepts are described. The algorithm uses the entropy of the generated image as a prior distribution, can be accelerated by the choice of an exponent, and converges uniformly to feasible images by ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.56340

    authors: Nunez J,Llacer J

    更新日期:1990-01-01 00:00:00

  • Dynamic PET reconstruction using wavelet regularization with adapted basis functions.

    abstract::Tomographic reconstruction from positron emission tomography (PET) data is an ill-posed problem that requires regularization. An attractive approach is to impose an l(1) -regularization constraint, which favors sparse solutions in the wavelet domain. This can be achieved quite efficiently thanks to the iterative algor...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2008.923698

    authors: Verhaeghe J,Van de Ville D,Khalidov I,D'Asseler Y,Lemahieu I,Unser M

    更新日期:2008-01-01 00:00:00

  • Automatic Cataract Classification Using Deep Neural Network With Discrete State Transition.

    abstract::Cataract is the clouding of lens, which affects vision and it is the leading cause of blindness in the world's population. Accurate and convenient cataract detection and cataract severity evaluation will improve the situation. Automatic cataract detection and grading methods are proposed in this paper. With prior know...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2019.2928229

    authors: Zhou Y,Li G,Li H

    更新日期:2020-02-01 00:00:00

  • Improving Registration Robustness for Image-Guided Liver Surgery in a Novel Human-to-Phantom Data Framework.

    abstract::In open image-guided liver surgery (IGLS), a sparse representation of the intraoperative organ surface can be acquired to drive image-to-physical registration. We hypothesize that uncharacterized error induced by variation in the collection patterns of organ surface data limits the accuracy and robustness of an IGLS r...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2017.2668842

    authors: Collins JA,Weis JA,Heiselman JS,Clements LW,Simpson AL,Jarnagin WR,Miga MI

    更新日期:2017-07-01 00:00:00

  • Joint Design of Excitation k-Space Trajectory and RF Pulse for Small-Tip 3D Tailored Excitation in MRI.

    abstract::We propose a new method for the joint design of k-space trajectory and RF pulse in 3D small-tip tailored excitation. Designing time-varying RF and gradient waveforms for a desired 3D target excitation pattern in MRI poses a non-linear, non-convex, constrained optimization problem with relatively large problem size tha...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2015.2478880

    authors: Hao S,Fessler JA,Noll DC,Nielsen JF

    更新日期:2016-02-01 00:00:00

  • A wavelet-based multiresolution regularized least squares reconstruction approach for optical tomography.

    abstract::In this paper, we present a wavelet-based multigrid approach to solve the perturbation equation encountered in optical tomography. With this scheme, the unknown image, the data, as well as the weight matrix are all represented by wavelet expansions, thus yielding a multiresolution representation of the original pertur...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.563666

    authors: Zhu W,Wang Y,Deng Y,Yao Y,Barbour RL

    更新日期:1997-04-01 00:00:00

  • Topology-based kernels with application to inference problems in Alzheimer's disease.

    abstract::Alzheimer's disease (AD) research has recently witnessed a great deal of activity focused on developing new statistical learning tools for automated inference using imaging data. The workhorse for many of these techniques is the support vector machine (SVM) framework (or more generally kernel-based methods). Most of t...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2011.2147327

    authors: Pachauri D,Hinrichs C,Chung MK,Johnson SC,Singh V

    更新日期:2011-10-01 00:00:00

  • Compressive Deconvolution in Medical Ultrasound Imaging.

    abstract::The interest of compressive sampling in ultrasound imaging has been recently extensively evaluated by several research teams. Following the different application setups, it has been shown that the RF data may be reconstructed from a small number of measurements and/or using a reduced number of ultrasound pulse emissio...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2015.2493241

    authors: Chen Z,Basarab A,Kouamé D

    更新日期:2016-03-01 00:00:00

  • Local phase tensor features for 3-D ultrasound to statistical shape+pose spine model registration.

    abstract::Most conventional spine interventions are performed under X-ray fluoroscopy guidance. In recent years, there has been a growing interest to develop nonionizing imaging alternatives to guide these procedures. Ultrasound guidance has emerged as a leading alternative. However, a challenging problem is automatic identific...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2014.2332571

    authors: Hacihaliloglu I,Rasoulian A,Rohling RN,Abolmaesumi P

    更新日期:2014-11-01 00:00:00

  • Automatic Plaque Detection in IVOCT Pullbacks Using Convolutional Neural Networks.

    abstract::Coronary heart disease is a common cause of death despite being preventable. To treat the underlying plaque deposits in the arterial walls, intravascular optical coherence tomography can be used by experts to detect and characterize the lesions. In clinical routine, hundreds of images are acquired for each patient, wh...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2018.2865659

    authors: Gessert N,Lutz M,Heyder M,Latus S,Leistner DM,Abdelwahed YS,Schlaefer A

    更新日期:2019-02-01 00:00:00

  • Neuron Segmentation With High-Level Biological Priors.

    abstract::We present a novel approach to the problem of neuron segmentation in image volumes acquired by an electron microscopy. Existing methods, such as agglomerative or correlation clustering, rely solely on boundary evidence and have problems where such an evidence is lacking (e.g., incomplete staining) or ambiguous (e.g., ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2017.2712360

    authors: Krasowski NE,Beier T,Knott GW,Kothe U,Hamprecht FA,Kreshuk A

    更新日期:2018-04-01 00:00:00

  • Edge displacement field-based classification for improved detection of polyps in CT colonography.

    abstract::Colorectal cancer can easily be prevented provided that the precursors to tumors, small colonic polyps, are detected and removed. Currently, the only definitive examination of the colon is fiber-optic colonoscopy, which is invasive and expensive. Computed tomographic colonography (CTC) is potentially a less costly and...

    journal_title:IEEE transactions on medical imaging

    pub_type: 临床试验,杂志文章

    doi:10.1109/TMI.2002.806405

    authors: Acar B,Beaulieu CF,Göktürk SB,Tomasi C,Paik DS,Jeffrey RB Jr,Yee J,Napel S

    更新日期:2002-12-01 00:00:00

  • Accurate event-driven motion compensation in high-resolution PET incorporating scattered and random events.

    abstract::With continuing improvements in spatial resolution of positron emission tomography (PET) scanners, small patient movements during PET imaging become a significant source of resolution degradation. This work develops and investigates a comprehensive formalism for accurate motion-compensated reconstruction which at the ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2008.917248

    authors: Rahmim A,Dinelle K,Cheng JC,Shilov MA,Segars WP,Lidstone SC,Blinder S,Rousset OG,Vajihollahi H,Tsui BM,Wong DF,Sossi V

    更新日期:2008-08-01 00:00:00

  • Shielded microstrip array for 7T human MR imaging.

    abstract::The high-frequency transceiver array based on the microstrip transmission line design is a promising technique for ultrahigh field magnetic resonance imaging (MRI) signal excitation and reception. However, with the increase of radio-frequency (RF) channels, the size of the ground plane in each microstrip coil element ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2009.2033597

    authors: Wu B,Wang C,Kelley DA,Xu D,Vigneron DB,Nelson SJ,Zhang X

    更新日期:2010-01-01 00:00:00

  • Unwarping of unidirectionally distorted EPI images.

    abstract::Echo-planar imaging (EPI) is a fast nuclear magnetic resonance imaging (MRI) method. Unfortunately, local magnetic field inhomogeneities induced mainly by the subject's presence cause significant geometrical distortion, predominantly along the phase-encoding direction, which must be undone to allow for meaningful furt...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.836368

    authors: Kybic J,Thévenaz P,Nirkko A,Unser M

    更新日期:2000-02-01 00:00:00

  • In vivo impedance imaging with total variation regularization.

    abstract::We show that electrical impedance tomography (EIT) image reconstruction algorithms with regularization based on the total variation (TV) functional are suitable for in vivo imaging of physiological data. This reconstruction approach helps to preserve discontinuities in reconstructed profiles, such as step changes in e...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2009.2022540

    authors: Borsic A,Graham BM,Adler A,Lionheart WR

    更新日期:2010-01-01 00:00:00

  • Spatio-temporal nonrigid registration for ultrasound cardiac motion estimation.

    abstract::We propose a new spatio-temporal elastic registration algorithm for motion reconstruction from a series of images. The specific application is to estimate displacement fields from two-dimensional ultrasound sequences of the heart. The basic idea is to find a spatio-temporal deformation field that effectively compensat...

    journal_title:IEEE transactions on medical imaging

    pub_type: 临床试验,杂志文章

    doi:10.1109/TMI.2005.852050

    authors: Ledesma-Carbayo MJ,Kybic J,Desco M,Santos A,Sühling M,Hunziker P,Unser M

    更新日期:2005-09-01 00:00:00

  • An Improved Method of Total Variation Superiorization Applied to Reconstruction in Proton Computed Tomography.

    abstract::Previous work has shown that total variation superiorization (TVS) improves reconstructed image quality in proton computed tomography (pCT). The structure of the TVS algorithm has evolved since then and this paper investigated if this new algorithmic structure provides additional benefits to pCT image quality. Structu...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2019.2911482

    authors: Schultze B,Censor Y,Karbasi P,Schubert KE,Schulte RW

    更新日期:2020-02-01 00:00:00

  • Multi-scale tubular structure detection in ultrasound imaging.

    abstract::We propose a novel, physics-based method for detecting multi-scale tubular features in ultrasound images. The detector is based on a Hessian-matrix eigenvalue method, but unlike previous work, our detector is guided by an optimal model of vessel-like structures with respect to the ultrasound-image formation process. O...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2014.2340912

    authors: Hennersperger C,Baust M,Waelkens P,Karamalis A,Ahmadi SA,Navab N

    更新日期:2015-01-01 00:00:00

  • Solving the Bloch equation with periodic excitation using harmonic balancing: application to Rabi modulated excitation.

    abstract::In waveform design for magnetic resonance applications, periodic continuous-wave excitation offers potential advantages that remain largely unexplored because of a lack of understanding of the Bloch equation with periodic continuous-wave excitations. Using harmonic balancing techniques the steady state solutions of th...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2015.2423313

    authors: Tahayori B,Johnston LA,Layton KJ,Farrell PM,Mareels IM

    更新日期:2015-10-01 00:00:00

  • Improved intrinsic motion detection using time-of-flight PET.

    abstract::Intrinsic or data-driven respiratory and cardiac motion detection often track the center-of-mass (COM) change in PET data to derive a motion gating signal. The effectiveness of this method depends on the contrast of the moving target to the relatively stationary background. The stationary background leads to a reduced...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2015.2423976

    authors: Xu J,Tsui BM

    更新日期:2015-10-01 00:00:00

  • Computer Aided Theragnosis Using Quantitative Ultrasound Spectroscopy and Maximum Mean Discrepancy in Locally Advanced Breast Cancer.

    abstract::A noninvasive computer-aided-theragnosis (CAT) system was developed for the early therapeutic cancer response assessment in patients with locally advanced breast cancer (LABC) treated with neoadjuvant chemotherapy. The proposed CAT system was based on multi-parametric quantitative ultrasound (QUS) spectroscopic method...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2015.2495246

    authors: Gangeh MJ,Tadayyon H,Sannachi L,Sadeghi-Naini A,Tran WT,Czarnota GJ

    更新日期:2016-03-01 00:00:00

  • An estimator for functional data with application to MRI.

    abstract::We propose a method for restoring the underlying true signal in noisy functional images. The Nadaraya-Watson (NW) estimator described in, e.g., [1] is a classical nonparametric estimator for this problem. Since the true scene in many applications contains abrupt changes between pixels of different types, a modificatio...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.906423

    authors: Godtliebsen F,Chu CK,Sørbye SH,Torheim G

    更新日期:2001-01-01 00:00:00

  • Learning Geodesic Active Contours for Embedding Object Global Information in Segmentation CNNs.

    abstract::Most existing CNNs-based segmentation methods rely on local appearances learned on the regular image grid, without consideration of the object global information. This article aims to embed the object global geometric information into a learning framework via the classical geodesic active contours (GAC). We propose a ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2020.3022693

    authors: Ma J,He J,Yang X

    更新日期:2021-01-01 00:00:00