Improved intrinsic motion detection using time-of-flight PET.

Abstract:

:Intrinsic or data-driven respiratory and cardiac motion detection often track the center-of-mass (COM) change in PET data to derive a motion gating signal. The effectiveness of this method depends on the contrast of the moving target to the relatively stationary background. The stationary background leads to a reduced COM displacement in PET data. Further, the COM calculated using axially truncated PET data is biased. To improve intrinsic motion detection for motion compensated image reconstruction, we use the time-of-flight (TOF) PET data of the original object f(x) to calculate the non-TOF PET data of a volume-of-interest (VOI) weighted object f(x)w(x) . The VOI-weighting w(x) can be chosen to reduce contribution from the stationary background. The reduced background in f(x)w(x) leads to an observed increase in the COM displacement. We also derive rebinning equations to obtain the exact axial COM using axially truncated PET data. To assess the quality of the motion gating signal, we analyze the variance property of the COM using different methods, including with(out) VOI weighting and with(out) compensation for axial data truncation. Analytical simulations, phantom and patient data demonstrate the effectiveness of the proposed approach in identifying the motion phase and in deriving a gating signal to be used for motion-compensated image reconstruction.

journal_name

IEEE Trans Med Imaging

authors

Xu J,Tsui BM

doi

10.1109/TMI.2015.2423976

subject

Has Abstract

pub_date

2015-10-01 00:00:00

pages

2131-45

issue

10

eissn

0278-0062

issn

1558-254X

journal_volume

34

pub_type

杂志文章
  • Standing-wave and RF penetration artifacts caused by elliptic geometry: an electrodynamic analysis of MRI.

    abstract::Motivated by the observation that the diagonal pattern of intensity nonuniformity usually associated with linearly polarized radio-frequency (RF) coils is often present in neurological scans using circularly polarized coils, a theoretical analysis has been conducted of the intensity nonuniformity inherent in imaging a...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.730409

    authors: Sled JG,Pike GB

    更新日期:1998-08-01 00:00:00

  • Electrical impedance tomography using induced currents.

    abstract::The mathematical basis of a new imaging modality, induced current electrical impedance tomography (EIT), is investigated, The ultimate aim of this technique is the reconstruction of conductivity distribution of the human body, from voltage measurements made between electrodes placed on the surface, when currents are i...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.293927

    authors: Gencer NG,Kuzuoglu M,Ider YZ

    更新日期:1994-01-01 00:00:00

  • Determination of optimal angiographic viewing angles: basic principles and evaluation study.

    abstract::Foreshortening of vessel segments in angiographic (biplane) projection images may cause misinterpretation of the extent and degree of coronary artery disease. The views in which the object of interest are visualized with minimum foreshortening are called optimal views. The authors present a complete approach to obtain...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.276141

    authors: Dumay AM,Reiber JC,Gerbrands JJ

    更新日期:1994-01-01 00:00:00

  • Spatio-temporal nonrigid registration for ultrasound cardiac motion estimation.

    abstract::We propose a new spatio-temporal elastic registration algorithm for motion reconstruction from a series of images. The specific application is to estimate displacement fields from two-dimensional ultrasound sequences of the heart. The basic idea is to find a spatio-temporal deformation field that effectively compensat...

    journal_title:IEEE transactions on medical imaging

    pub_type: 临床试验,杂志文章

    doi:10.1109/TMI.2005.852050

    authors: Ledesma-Carbayo MJ,Kybic J,Desco M,Santos A,Sühling M,Hunziker P,Unser M

    更新日期:2005-09-01 00:00:00

  • Establishment of an Automated Algorithm Utilizing Optical Coherence Tomography and Micro-Computed Tomography Imaging to Reconstruct the 3-D Deformed Stent Geometry.

    abstract::Percutaneous coronary intervention (PCI) is the prevalent treatment for coronary artery disease, with hundreds of thousands of stents implanted annually. Computational studies have demonstrated the role of biomechanics in the failure of vascular stents, but clinical studies is this area are limited by a lack of unders...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2018.2870714

    authors: Elliott MR,Kim D,Molony DS,Morris L,Samady H,Joshi S,Timmins LH

    更新日期:2019-03-01 00:00:00

  • Wavelet analysis for brain-function imaging.

    abstract::The authors present a new algorithmic procedure for the analysis of brain images. This procedure is specifically designed to image the activity and functional organization of the brain. The authors' results are tested on data collected and previously analyzed with the technique known as in vivo optical imaging of intr...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.414621

    authors: Carmona RA,Hwang WL,Frostig RD

    更新日期:1995-01-01 00:00:00

  • High-Frame-Rate Echocardiography Using Coherent Compounding With Doppler-Based Motion-Compensation.

    abstract::High-frame-rate ultrasonography based on coherent compounding of unfocused beams can potentially transform the assessment of cardiac function. As it requires successive waves to be combined coherently, this approach is sensitive to high-velocity tissue motion. We investigated coherent compounding of tilted diverging w...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2016.2523346

    authors: Poree J,Posada D,Hodzic A,Tournoux F,Cloutier G,Garcia D

    更新日期:2016-07-01 00:00:00

  • Semiautomated border tracking of cine echocardiographic ventnrcular images.

    abstract::Two-dimensional ultrasound sector scans of the left ventricle (LV) are commonly used to diagnose cardiac mechanical function. Present quantification procedures of wall motion by this technique entail inaccuracies, mainly due to relatively poor image quality and the absence of a definition of the relative position of t...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.1987.4307836

    authors: Adam D,Hareuveni O,Sideman S

    更新日期:1987-01-01 00:00:00

  • Patch-Based Output Space Adversarial Learning for Joint Optic Disc and Cup Segmentation.

    abstract::Glaucoma is a leading cause of irreversible blindness. Accurate segmentation of the optic disc (OD) and optic cup (OC) from fundus images is beneficial to glaucoma screening and diagnosis. Recently, convolutional neural networks demonstrate promising progress in the joint OD and OC segmentation. However, affected by t...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2019.2899910

    authors: Wang S,Yu L,Yang X,Fu CW,Heng PA

    更新日期:2019-11-01 00:00:00

  • Denoising functional MR images: a comparison of wavelet denoising and Gaussian smoothing.

    abstract::We present a general wavelet-based denoising scheme for functional magnetic resonance imaging (fMRI) data and compare it to Gaussian smoothing, the traditional denoising method used in fMRI analysis. One-dimensional WaveLab thresholding routines were adapted to two-dimensional (2-D) images, and applied to 2-D wavelet ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2004.824234

    authors: Wink AM,Roerdink JB

    更新日期:2004-03-01 00:00:00

  • Robust Empirical Bayesian Reconstruction of Distributed Sources for Electromagnetic Brain Imaging.

    abstract::Electromagnetic brain imaging is the reconstruction of brain activity from non-invasive recordings of the magnetic fields and electric potentials. An enduring challenge in this imaging modality is estimating the number, location, and time course of sources, especially for the reconstruction of distributed brain source...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2019.2932290

    authors: Cai C,Diwakar M,Chen D,Sekihara K,Nagarajan SS

    更新日期:2020-03-01 00:00:00

  • An optimization transfer algorithm for nonlinear parametric image reconstruction from dynamic PET data.

    abstract::Direct reconstruction of kinetic parameters from raw projection data is a challenging task in molecular imaging using dynamic positron emission tomography (PET). This paper presents a new optimization transfer algorithm for penalized likelihood direct reconstruction of nonlinear parametric images that is easy to use a...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2012.2212203

    authors: Wang G,Qi J

    更新日期:2012-10-01 00:00:00

  • Prostate Cancer Detection Using Composite Impedance Metric.

    abstract::Prostate cancer (PCa) recurrences are often predicted by assessing the status of surgical margins (SM)- positive surgical margins (PSM) increase the chances of biochemical recurrence by 2-4 times which may lead to PCa recurrence. To this end, an electrical impedance acquisition system with a microendoscopic probe was ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2016.2578939

    authors: Khan S,Mahara A,Hyams ES,Schned AR,Halter RJ

    更新日期:2016-12-01 00:00:00

  • Renal Segmentation From 3D Ultrasound via Fuzzy Appearance Models and Patient-Specific Alpha Shapes.

    abstract::Ultrasound (US) imaging is the primary imaging modality for pediatric hydronephrosis, which manifests as the dilation of the renal collecting system (CS). In this paper, we present a new framework for the segmentation of renal structures, kidney and CS, from 3DUS scans. First, the kidney is segmented using an active s...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2016.2572641

    authors: Cerrolaza JJ,Safdar N,Biggs E,Jago J,Peters CA,Linguraru MG

    更新日期:2016-11-01 00:00:00

  • Spatial-resolution enhancement in computed tomography.

    abstract::We propose an approach that combines an asymmetric fan-beam configuration and a new reconstruction algorithm to enhancing spatial resolution in computed tomography (CT). The asymmetric configuration can be achieved by changing the center of rotation (COR) from the conventional symmetric configuration. It does not, how...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/tmi.2004.840846

    authors: Pan X,Yu L,Kao CM

    更新日期:2005-02-01 00:00:00

  • PORTR: Pre-operative and post-recurrence brain tumor registration.

    abstract::We propose a new method for deformable registration of pre-operative and post-recurrence brain MR scans of glioma patients. Performing this type of intra-subject registration is challenging as tumor, resection, recurrence, and edema cause large deformations, missing correspondences, and inconsistent intensity profiles...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2013.2293478

    authors: Kwon D,Niethammer M,Akbari H,Bilello M,Davatzikos C,Pohl KM

    更新日期:2014-03-01 00:00:00

  • Accelerated iterative transmission CT reconstruction using an ordered subsets convex algorithm.

    abstract::Iterative maximum likelihood (ML) transmission computed tomography algorithms have distinct advantages over Fourier-based reconstruction, but unfortunately require increased computation time. The convex algorithm [1] is a relatively fast iterative ML algorithm but it is nevertheless too slow for many applications. The...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.746730

    authors: Kamphuis C,Beekman FJ

    更新日期:1998-12-01 00:00:00

  • Tracking pylorus in ultrasonic image sequences with edge-based optical flow.

    abstract::Tracking pylorus in ultrasonic image sequences is an important step in the analysis of duodenogastric reflux (DGR). We propose a joint prediction and segmentation method (JPS) which combines optical flow with active contour to track pylorus. The goal of the proposed method is to improve the pyloric tracking accuracy b...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2012.2183884

    authors: Chen C,Wang Y,Yu J,Zhou Z,Shen L,Chen Y

    更新日期:2012-03-01 00:00:00

  • Investigation of Axial and Angular Sampling in Multi-Detector Pinhole-SPECT Brain Imaging.

    abstract::We designed a dedicated multi-detector multi-pinhole brain SPECT scanner to generate images of higher quality compared to general-purpose systems. The system, AdaptiSPECT-C, is intended to adapt its sensitivity-resolution trade-off by varying its aperture configurations allowing both high-sensitivity dynamic and high-...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2020.3015079

    authors: Zeraatkar N,Kalluri KS,Auer B,Konik A,Fromme TJ,Furenlid LR,Kuo PH,King MA

    更新日期:2020-12-01 00:00:00

  • Spiral-CT-based assessment of tracheal stenoses using 3-D-skeletonization.

    abstract:PURPOSE:Demonstration of a technique for three-dimensional (3-D) assessment of tracheal-stenoses, regarding site, length and degree, based on spiral computed tomography (S-CT). PATIENTS AND METHODS:S-CT scanning and automated segmentation of the laryngo-tracheal tract (LTT) was followed by the extraction of the LTT me...

    journal_title:IEEE transactions on medical imaging

    pub_type: 临床试验,杂志文章

    doi:10.1109/42.996344

    authors: Sorantin E,Halmai C,Erdöhelyi B,Palágyi K,Nyúl LG,Ollé K,Geiger B,Lindbichler F,Friedrich G,Kiesler K

    更新日期:2002-03-01 00:00:00

  • Automatic segmentation of scaling in 2-D psoriasis skin images.

    abstract::Psoriasis is a chronic inflammatory skin disease that affects over 3% of the population. Various methods are currently used to evaluate psoriasis severity and to monitor therapeutic response. The PASI system of scoring is widely used for evaluating psoriasis severity. It employs a visual analogue scale to score the th...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2012.2236349

    authors: Lu J,Kazmierczak E,Manton JH,Sinclair R

    更新日期:2013-04-01 00:00:00

  • Intrathoracic airway trees: segmentation and airway morphology analysis from low-dose CT scans.

    abstract::The segmentation of the human airway tree from volumetric computed tomography (CT) images builds an important step for many clinical applications and for physiological studies. Previously proposed algorithms suffer from one or several problems: leaking into the surrounding lung parenchyma, the need for the user to man...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2005.857654

    authors: Tschirren J,Hoffman EA,McLennan G,Sonka M

    更新日期:2005-12-01 00:00:00

  • Multi-channel microstrip transceiver arrays using harmonics for high field MR imaging in humans.

    abstract::Radio-frequency (RF) transceiver array design using primary and higher order harmonics for in vivo parallel magnetic resonance imaging imaging (MRI) and spectroscopic imaging is proposed. The improved electromagnetic decoupling performance, unique magnetic field distributions and high-frequency operation capabilities ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2011.2166273

    authors: Wu B,Wang C,Lu J,Pang Y,Nelson SJ,Vigneron DB,Zhang X

    更新日期:2012-02-01 00:00:00

  • The detection and quantification of retinopathy using digital angiograms.

    abstract::An algorithm is presented for the analysis and quantification of the vascular structures of the human retina. Information about retinal blood vessel morphology is used in grading the severity and progression of a number of diseases. These disease processes are typically followed over relatively long time courses, and ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.363106

    authors: Zhou L,Rzeszotarski MS,Singerman LJ,Chokreff JM

    更新日期:1994-01-01 00:00:00

  • Semi-automatic segmentation of vascular network images using a rotating structuring element (ROSE) with mathematical morphology and dual feature thresholding.

    abstract::A method for measuring the spatial concentration of specific categories of vessels in a vascular network consisting of vessels of several diameters, lengths, and orientations is demonstrated. It is shown that a combination of the mathematical morphology operation, opening, with a linear rotating structuring element (R...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.241865

    authors: Thackray BD,Nelson AC

    更新日期:1993-01-01 00:00:00

  • An improved algorithm for 2-D translational motion artifact correction.

    abstract::The quality of magnetic resonance imaging systems has improved to the point that motion is a major limitation in many examinations. Translational motion in the imaging plane causes the phase of the data to be corrupted. An algorithm using computer post-processing is proposed to correct the phase of the data, and hence...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.108589

    authors: Medley M,Yan H,Rosenfeld D

    更新日期:1991-01-01 00:00:00

  • Simulation of the expected performance of a seamless scanner for brain PET based on highly pixelated CdTe detectors.

    abstract::The aim of this work is the evaluation of the design for a nonconventional PET scanner, the voxel imaging PET (VIP), based on pixelated room-temperature CdTe detectors yielding a true 3-D impact point with a density of 450 channels/cm(3), for a total 6 336 000 channels in a seamless ring shaped volume. The system is s...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2013.2284657

    authors: Mikhaylova E,De Lorenzo G,Chmeissani M,Kolstein M,Cañadas M,Arce P,Calderón Y,Uzun D,Ariño G,Macias-Montero JG,Martinez R,Puigdengoles C,Cabruja E

    更新日期:2014-02-01 00:00:00

  • 3-D Contrast Source Inversion-Electrical Properties Tomography.

    abstract::Contrast source inversion-electrical properties tomography (CSI-EPT) is an iterative reconstruction method to retrieve the electrical properties (EPs) of tissues from magnetic resonance data. The method is based on integral representations of the electromagnetic field and has been shown to allow EP reconstructions of ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2018.2816125

    authors: Leijsen RL,Brink WM,van den Berg CAT,Webb AG,Remis RF

    更新日期:2018-09-01 00:00:00

  • Image-Based Investigation of Human in Vivo Myofibre Strain.

    abstract::Cardiac myofibre deformation is an important determinant of the mechanical function of the heart. Quantification of myofibre strain relies on 3D measurements of ventricular wall motion interpreted with respect to the tissue microstructure. In this study, we estimated in vivo myofibre strain using 3D structural and fun...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2016.2580573

    authors: Wang VY,Casta C,Zhu YM,Cowan BR,Croisille P,Young AA,Clarysse P,Nash MP

    更新日期:2016-11-01 00:00:00

  • EMS-Net: A Deep Learning Method for Autodetecting Epileptic Magnetoencephalography Spikes.

    abstract::Epilepsy is a neurological disorder characterized by sudden and unpredictable epileptic seizures, which incurs significant negative impacts on patients' physical, psychological and social health. A practical approach to assist with the clinical assessment and treatment planning for patients is to process magnetoenceph...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2019.2958699

    authors: Zheng L,Liao P,Luo S,Sheng J,Teng P,Luan G,Gao JH

    更新日期:2020-06-01 00:00:00