Abstract:
:Ultrasound (US) imaging is the primary imaging modality for pediatric hydronephrosis, which manifests as the dilation of the renal collecting system (CS). In this paper, we present a new framework for the segmentation of renal structures, kidney and CS, from 3DUS scans. First, the kidney is segmented using an active shape model-based approach, tailored to deal with the challenges raised by US images. A weighted statistical shape model allows to compensate the image variation with the propagation direction of the US wavefront. The model is completed with a new fuzzy appearance model and a multi-scale omnidirectional Gabor-based appearance descriptor. Next, the CS is segmented using an active contour formulation, which combines contour- and intensity-based terms. The new positive alpha detector presented here allows to control the propagation process by means of a patient-specific stopping function created from the bands of adipose tissue within the kidney. The performance of the new segmentation approach was evaluated on a dataset of 39 cases, showing an average Dice's coefficient of 0.86±0.05 for the kidney, and 0.74 ± 0.10 for the CS segmentation, respectively. These promising results demonstrate the potential utility of this framework for the US-based assessment of the severity of pediatric hydronephrosis.
journal_name
IEEE Trans Med Imagingjournal_title
IEEE transactions on medical imagingauthors
Cerrolaza JJ,Safdar N,Biggs E,Jago J,Peters CA,Linguraru MGdoi
10.1109/TMI.2016.2572641subject
Has Abstractpub_date
2016-11-01 00:00:00pages
2393-2402issue
11eissn
0278-0062issn
1558-254Xjournal_volume
35pub_type
杂志文章abstract::A two-stage adaptive vector quantization scheme for radiographic image sequence coding is introduced. Each frame in the sequence is first decomposed into a set of vectors, corresponding to nonoverlapping spatially contiguous block of pixels. A codebook is generated using a training set of vectors drawn from the sequen...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.3938
更新日期:1988-01-01 00:00:00
abstract::Respiratory signals are required for image gating and motion compensation in minimally invasive interventions. In X-ray fluoroscopy, extraction of a respiratory signal can be challenging due to characteristics of interventional imaging, in particular injection of contrast agent and automatic exposure control. We prese...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2016.2609888
更新日期:2017-04-01 00:00:00
abstract::Almost all magnetic resonance electrical impedance tomography (MREIT) reconstruction algorithms proposed to date assume isotropic conductivity in order to simplify the image reconstruction. However, it is well known that most of biological tissues have anisotropic conductivity values. In this study, four novel anisotr...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2011.2171192
更新日期:2012-03-01 00:00:00
abstract::Detecting tools in surgical videos is an important ingredient for context-aware computer-assisted surgical systems. To this end, we present a new surgical tool detection dataset and a method for joint tool detection and pose estimation in 2d images. Our two-stage pipeline is data-driven and relaxes strong assumptions ...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2015.2450831
更新日期:2015-12-01 00:00:00
abstract::Electromagnetic brain imaging is the reconstruction of brain activity from non-invasive recordings of the magnetic fields and electric potentials. An enduring challenge in this imaging modality is estimating the number, location, and time course of sources, especially for the reconstruction of distributed brain source...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2019.2932290
更新日期:2020-03-01 00:00:00
abstract::The effects of Squashing, an algorithm introduced by J.A. Reeds and L.A. Shepp (see ibid., vol.MI-6, no.2, p.89-97, June 1987), are described. It is proven that Squashing induces a weight function upon the projections. Intuitive and numerical evidence is presented showing that this weight function is not desirable at ...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.57761
更新日期:1990-01-01 00:00:00
abstract::Magnetic particle imaging (MPI) is able to provide high temporal and good spatial resolution, high signal to noise ratio and sensitivity. Furthermore, it is a truly quantitative method as its signal strength is proportional to the concentration of its tracer, superparamagnetic iron oxide nanoparticles (SPIOs), over a ...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2016.2559538
更新日期:2016-10-01 00:00:00
abstract::Magnetic resonance parameter mapping (e.g., T1 mapping, T2 mapping, T*2 mapping) is a valuable tool for tissue characterization. However, its practical utility has been limited due to long data acquisition time. This paper addresses this problem with a new model-based parameter mapping method. The proposed method util...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2014.2322815
更新日期:2014-09-01 00:00:00
abstract::This paper presents a new approach to the correction of intensity inhomogeneities in magnetic resonance imaging (MRI) that significantly improves intensity-based tissue segmentation. The distortion of the image brightness values by a low-frequency bias field impedes visual inspection and segmentation. The new correcti...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.845174
更新日期:2000-03-01 00:00:00
abstract::The watershed transform has interesting properties that make it useful for many different image segmentation applications: it is simple and intuitive, can be parallelized, and always produces a complete division of the image. However, when applied to medical image analysis, it has important drawbacks (oversegmentation...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2004.824224
更新日期:2004-04-01 00:00:00
abstract::Prostate cancer (PCa) recurrences are often predicted by assessing the status of surgical margins (SM)- positive surgical margins (PSM) increase the chances of biochemical recurrence by 2-4 times which may lead to PCa recurrence. To this end, an electrical impedance acquisition system with a microendoscopic probe was ...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2016.2578939
更新日期:2016-12-01 00:00:00
abstract::The quality and quantitative accuracy of iteratively reconstructed SPECT images improves when better point spread function (PSF) models of the gamma camera are used during reconstruction. Here, inclusion in the PSF model of photon crosstalk between different slices caused by limited gamma camera resolution and scatter...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.511752
更新日期:1996-01-01 00:00:00
abstract::In the PET system a block detector, which is a position-sensitive photomultiplier (PMT) tube coupled to four arrays of 1.7-mm-wide BGO crystals, is utilized. Fifteen block detectors are positioned to form a 35-cm-diameter ring, with four BGO arrays coupled to each PMT. This provides four detector rings, giving the sys...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.192694
更新日期:1992-01-01 00:00:00
abstract::Advances in the area of digital chest radiography have resulted in the acquisition of high-quality images of the human chest. With these advances, there arises a genuine need for image processing algorithms specific to the chest, in order to fully exploit this digital technology. We have implemented the well-known tec...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.1987.4307791
更新日期:1987-01-01 00:00:00
abstract::Active shape models bear a great promise for model-based medical image analysis. Their practical use, though, is undermined due to the need to train such models on large image databases. Automatic building of point distribution models (PDMs) has been successfully addressed and a number of autolandmarking techniques ar...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2008.2004819
更新日期:2008-11-01 00:00:00
abstract::An electrical impedance tomography (EIT) system that uses the optimal current method to inject currents and the regularized Newton-Raphson algorithm to reconstruct an image of resistivity distribution is discussed. Iterative methods to derive the optimal current patterns through iterative physical measurements are dev...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.192684
更新日期:1992-01-01 00:00:00
abstract::Accurate gain control of PET detectors is a prerequisite for quantitative accuracy. A shift in the 511 keV peak position can lead to errors in scatter correction, degrading quantitation. The PET detectors in a PET/MR scanner are subject to thermal transients due to eddy currents induced during gradient-intensive MRI s...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2020.3022321
更新日期:2021-01-01 00:00:00
abstract::The quality of magnetic resonance imaging systems has improved to the point that motion is a major limitation in many examinations. Translational motion in the imaging plane causes the phase of the data to be corrupted. An algorithm using computer post-processing is proposed to correct the phase of the data, and hence...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.108589
更新日期:1991-01-01 00:00:00
abstract::We have developed a general-purpose registration algorithm for medical images and volumes. This method models the transformation between images as locally affine but globally smooth. The model also explicitly accounts for local and global variations in image intensities. This approach is built upon a differential mult...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2003.815069
更新日期:2003-07-01 00:00:00
abstract::During the last two decades, various Doppler methods have been successfully used to screen patients with significant cerebral and peripheral vascular disease. In general terms, the principal advantages of Doppler ultrasound techniques in the evaluation of atherosclerotic lesions are that they: 1) are noninvasive, 2) a...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.1982.4307550
更新日期:1982-01-01 00:00:00
abstract::The duration of a positron emission tomography (PET) imaging scan can be reduced if the transmission scan of one patient which is used for emission correction can be synthesized by using the reference transmission scan of another patient. In this paper, we propose a new intersubjects PET emission scan registration met...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.640744
更新日期:1997-10-01 00:00:00
abstract::Bronchoscopy is a major step in lung cancer staging. To perform bronchoscopy, the physician uses a procedure plan, derived from a patient's 3D computed-tomography (CT) chest scan, to navigate the bronchoscope through the lung airways. Unfortunately, physicians vary greatly in their ability to perform bronchoscopy. As ...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2013.2252361
更新日期:2013-08-01 00:00:00
abstract::If a flow field exists within an object that is being imaged, there could be a velocity spectrum in each voxel due to the finite voxel size. Consequently, the mean value and the variance of velocity in each voxel can be defined and used to describe the velocity spectrum. An NMR (nuclear magnetic resonance) imaging tec...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.14520
更新日期:1988-01-01 00:00:00
abstract::Computed ultrasound tomography in echo mode (CUTE) is a promising ultrasound (US) based multi-modal technique that allows to image the spatial distribution of speed of sound (SoS) inside tissue using hand-held pulse-echo US. It is based on measuring the phase shift of echoes when detected under varying steering angles...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2020.3029286
更新日期:2020-10-07 00:00:00
abstract::Glaucoma is a chronic eye disease that leads to irreversible vision loss. The cup to disc ratio (CDR) plays an important role in the screening and diagnosis of glaucoma. Thus, the accurate and automatic segmentation of optic disc (OD) and optic cup (OC) from fundus images is a fundamental task. Most existing methods s...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2018.2791488
更新日期:2018-07-01 00:00:00
abstract::Cardiac myofibre deformation is an important determinant of the mechanical function of the heart. Quantification of myofibre strain relies on 3D measurements of ventricular wall motion interpreted with respect to the tissue microstructure. In this study, we estimated in vivo myofibre strain using 3D structural and fun...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2016.2580573
更新日期:2016-11-01 00:00:00
abstract::We introduce a multi-region model for simultaneous segmentation of medical images. In contrast to many other models, geometric constraints such as inclusion and exclusion between the regions are enforced, which makes it possible to correctly segment different regions even if the intensity distributions are identical. ...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2012.2218117
更新日期:2013-02-01 00:00:00
abstract::We propose a novel, physics-based method for detecting multi-scale tubular features in ultrasound images. The detector is based on a Hessian-matrix eigenvalue method, but unlike previous work, our detector is guided by an optimal model of vessel-like structures with respect to the ultrasound-image formation process. O...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2014.2340912
更新日期:2015-01-01 00:00:00
abstract::The comment of Stig Steenstrup on the use of gray level entropy function in our paper' has been addressed. The entropy measure has not been used in the procedure of enhancement, but it has only been used to show statistically that the enhanced images have larger gray level entropy, and therefore better utilize the gra...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.1987.4307802
更新日期:1987-01-01 00:00:00
abstract::Radio-frequency current density imaging (RF-CDI) is an imaging technique that noninvasively measures current density distribution at the Larmor frequency utilizing magnetic resonance imaging (MRI). Previously implemented RF-CDI techniques were only able to image a single slice transverse to the static magnetic field B...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2008.2012161
更新日期:2009-07-01 00:00:00