Image-Based Investigation of Human in Vivo Myofibre Strain.

Abstract:

:Cardiac myofibre deformation is an important determinant of the mechanical function of the heart. Quantification of myofibre strain relies on 3D measurements of ventricular wall motion interpreted with respect to the tissue microstructure. In this study, we estimated in vivo myofibre strain using 3D structural and functional atlases of the human heart. A finite element modelling framework was developed to incorporate myofibre orientations of the left ventricle (LV) extracted from 7 explanted normal human hearts imaged ex vivo with diffusion tensor magnetic resonance imaging (DTMRI) and kinematic measurements from 7 normal volunteers imaged in vivo with tagged MRI. Myofibre strain was extracted from the DTMRI and 3D strain from the tagged MRI. We investigated: i) the spatio-temporal variation of myofibre strain throughout the cardiac cycle; ii) the sensitivity of myofibre strain estimates to the variation in myofibre angle between individuals; and iii) the sensitivity of myofibre strain estimates to variations in wall motion between individuals. Our analysis results indicate that end systolic (ES) myofibre strain is approximately homogeneous throughout the entire LV, irrespective of the inter-individual variation in myofibre orientation. Additionally, inter-subject variability in myofibre orientations has greater effect on the variabilities in myofibre strain estimates than the ventricular wall motions. This study provided the first quantitative evidence of homogeneity of ES myofibre strain using minimally-invasive medical images of the human heart and demonstrated that image-based modelling framework can provide detailed insight to the mechanical behaviour of the myofibres, which may be used as a biomarker for cardiac diseases that affect cardiac mechanics.

journal_name

IEEE Trans Med Imaging

authors

Wang VY,Casta C,Zhu YM,Cowan BR,Croisille P,Young AA,Clarysse P,Nash MP

doi

10.1109/TMI.2016.2580573

subject

Has Abstract

pub_date

2016-11-01 00:00:00

pages

2486-2496

issue

11

eissn

0278-0062

issn

1558-254X

journal_volume

35

pub_type

杂志文章
  • Low-field 3-DFT MRI: conceptual, analytical, and experimental aspects.

    abstract::Three-dimensional Fourier transform (3-DFT) magnetic resonance imaging (MRI) offers advantages in terms of signal-to-noise (S/N) per unit of time for the case where a large number of slices is desired. This advantage is enhanced when the relaxation time, T(1 ), is short. Because time limitations in 3-DFT imaging force...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.97588

    authors: Kramer DM,Kaufman L,Rothschild P,Hale J,Wummer J,Hake KK

    更新日期:1991-01-01 00:00:00

  • Noise characterization of block-iterative reconstruction algorithms: II. Monte Carlo simulations.

    abstract::In Soares et al. (2000), the ensemble statistical properties of the rescaled block-iterative expectation-maximization (RBI-EM) reconstruction algorithm and rescaled block-iterative simultaneous multiplicative algebraic reconstruction technique (RBI-SMART) were derived. Included in this analysis were the special cases ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/tmi.2004.836876

    authors: Soares EJ,Glick SJ,Hoppin JW

    更新日期:2005-01-01 00:00:00

  • Simultaneous Analysis of 2D Echo Views for Left Atrial Segmentation and Disease Detection.

    abstract::We propose a joint information approach for automatic analysis of 2D echocardiography (echo) data. The approach combines a priori images, their segmentations and patient diagnostic information within a unified framework to determine various clinical parameters, such as cardiac chamber volumes, and cardiac disease labe...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2016.2593900

    authors: Allan G,Nouranian S,Tsang T,Seitel A,Mirian M,Jue J,Hawley D,Fleming S,Gin K,Swift J,Rohling R,Abolmaesumi P

    更新日期:2017-01-01 00:00:00

  • Total variation regularization for fMRI-based prediction of behavior.

    abstract::While medical imaging typically provides massive amounts of data, the extraction of relevant information for predictive diagnosis remains a difficult challenge. Functional magnetic resonance imaging (fMRI) data, that provide an indirect measure of task-related or spontaneous neuronal activity, are classically analyzed...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2011.2113378

    authors: Michel V,Gramfort A,Varoquaux G,Eger E,Thirion B

    更新日期:2011-07-01 00:00:00

  • Probabilistic sparse matching for robust 3D/3D fusion in minimally invasive surgery.

    abstract::Classical surgery is being overtaken by minimally invasive and transcatheter procedures. As there is no direct view or access to the affected anatomy, advanced imaging techniques such as 3D C-arm computed tomography (CT) and C-arm fluoroscopy are routinely used in clinical practice for intraoperative guidance. However...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2014.2343936

    authors: Neumann D,Grbic S,John M,Navab N,Hornegger J,Ionasec R

    更新日期:2015-01-01 00:00:00

  • Multiscale AM-FM methods for diabetic retinopathy lesion detection.

    abstract::In this paper, we propose the use of multiscale amplitude-modulation-frequency-modulation (AM-FM) methods for discriminating between normal and pathological retinal images. The method presented in this paper is tested using standard images from the early treatment diabetic retinopathy study. We use 120 regions of 40 x...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2009.2037146

    authors: Agurto C,Murray V,Barriga E,Murillo S,Pattichis M,Davis H,Russell S,Abramoff M,Soliz P

    更新日期:2010-02-01 00:00:00

  • Computation of the mid-sagittal plane in 3-D brain images.

    abstract::We present a new method to automatically compute, reorient, and recenter the mid-sagittal plane in anatomical and functional three-dimensional (3-D) brain images. This iterative approach is composed of two steps. At first, given an initial guess of the mid-sagittal plane (generally, the central plane of the image grid...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.993131

    authors: Prima S,Ourselin S,Ayache N

    更新日期:2002-02-01 00:00:00

  • Robust simultaneous detection of coronary borders in complex images.

    abstract::Visual estimation of coronary obstruction severity from angiograms suffers from poor inter- and intraobserver reproducibility and is often inaccurate. In spite of the widely recognized limitations of visual analysis, automated methods have not found widespread clinical use, in part because they too frequently fail to ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.370412

    authors: Sonka M,Winniford MD,Collins SM

    更新日期:1995-01-01 00:00:00

  • PORTR: Pre-operative and post-recurrence brain tumor registration.

    abstract::We propose a new method for deformable registration of pre-operative and post-recurrence brain MR scans of glioma patients. Performing this type of intra-subject registration is challenging as tumor, resection, recurrence, and edema cause large deformations, missing correspondences, and inconsistent intensity profiles...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2013.2293478

    authors: Kwon D,Niethammer M,Akbari H,Bilello M,Davatzikos C,Pohl KM

    更新日期:2014-03-01 00:00:00

  • Spatial transformation of DWI data using non-negative sparse representation.

    abstract::This paper presents an algorithm to transform and reconstruct diffusion-weighted imaging (DWI) data for alignment of micro-structures in association with spatial transformations. The key idea is to decompose the diffusion signal profile, a function defined on a unit sphere, into a series of weighted diffusion basis fu...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2012.2204766

    authors: Yap PT,Shen D

    更新日期:2012-11-01 00:00:00

  • A fast Bayesian reconstruction algorithm for emission tomography with entropy prior converging to feasible images.

    abstract::The development and tests of an iterative reconstruction algorithm for emission tomography based on Bayesian statistical concepts are described. The algorithm uses the entropy of the generated image as a prior distribution, can be accelerated by the choice of an exponent, and converges uniformly to feasible images by ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.56340

    authors: Nunez J,Llacer J

    更新日期:1990-01-01 00:00:00

  • Tomographic fluorescence imaging in tissue phantoms: a novel reconstruction algorithm and imaging geometry.

    abstract::A novel image reconstruction algorithm has been developed and demonstrated for fluorescence-enhanced frequency-domain photon migration (FDPM) tomography from measurements of area illumination with modulated excitation light and area collection of emitted fluorescence light using a gain modulated image-intensified char...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/tmi.2004.839359

    authors: Roy R,Thompson AB,Godavarty A,Sevick-Muraca EM

    更新日期:2005-02-01 00:00:00

  • Spherical harmonics microwave algorithm for shape and location reconstruction of breast cancer tumor.

    abstract::A reconstruction algorithm to simultaneously estimate the shape and location of three-dimensional breast cancer tumor is presented and its utility is analyzed. The approach is based on a spherical harmonic decomposition to capture the shape of the tumor. We combine a gradient descent optimization method with a direct ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/tmi.2006.881377

    authors: El-Shenawee M,Miller EL

    更新日期:2006-10-01 00:00:00

  • Splat feature classification with application to retinal hemorrhage detection in fundus images.

    abstract::A novel splat feature classification method is presented with application to retinal hemorrhage detection in fundus images. Reliable detection of retinal hemorrhages is important in the development of automated screening systems which can be translated into practice. Under our supervised approach, retinal color images...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2012.2227119

    authors: Tang L,Niemeijer M,Reinhardt JM,Garvin MK,Abràmoff MD

    更新日期:2013-02-01 00:00:00

  • Intrathoracic airway trees: segmentation and airway morphology analysis from low-dose CT scans.

    abstract::The segmentation of the human airway tree from volumetric computed tomography (CT) images builds an important step for many clinical applications and for physiological studies. Previously proposed algorithms suffer from one or several problems: leaking into the surrounding lung parenchyma, the need for the user to man...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2005.857654

    authors: Tschirren J,Hoffman EA,McLennan G,Sonka M

    更新日期:2005-12-01 00:00:00

  • An Enhanced SMART-RECON Algorithm for Time-Resolved C-Arm Cone-Beam CT Imaging.

    abstract::Temporal resolution in time-resolved cone-beam CT (TR-CBCT) imaging is often limited by the time needed to acquire a complete data set for image reconstruction. With the recent developments of performing nearly limited-view artifact-free reconstruction from data in a limited-view angle range and a prior image, tempora...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2019.2960720

    authors: Li Y,Garrett JW,Li K,Strother C,Chen GH

    更新日期:2020-06-01 00:00:00

  • Principal Component Analysis Based Dynamic Cone Beam X-Ray Luminescence Computed Tomography: A Feasibility Study.

    abstract::Cone beam X-ray luminescence computed tomography (CB-XLCT) is a promising imaging technique in studying the physiological and pathological processes in small animals. However, the dynamic bio-distributions of probes in small animal, especially in adjacent targets are still hard to be captured directly from dynamic CB-...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2019.2917026

    authors: Pu H,Gao P,Liu Y,Rong J,Shi F,Lu H

    更新日期:2019-12-01 00:00:00

  • Detecting Cardiovascular Disease from Mammograms With Deep Learning.

    abstract::Coronary artery disease is a major cause of death in women. Breast arterial calcifications (BACs), detected inmammograms, can be useful riskmarkers associated with the disease. We investigate the feasibility of automated and accurate detection ofBACsinmammograms for risk assessment of coronary artery disease. We devel...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2017.2655486

    authors: Wang J,Ding H,Bidgoli FA,Zhou B,Iribarren C,Molloi S,Baldi P

    更新日期:2017-05-01 00:00:00

  • Self-stabilizing colonic capsule endoscopy: pilot study of acute canine models.

    abstract::Video capsule endoscopy (VCE) is a noninvasive method for examining the gastrointestinal tract which has been successful in small intestine studies. Recently, VCE has been attempted in the colon. However, the capsule often tumbles in the wider colonic lumen, resulting in missed regions. Self-stabilizing VCE is a novel...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2011.2163165

    authors: Filip D,Yadid-Pecht O,Andrews CN,Mintchev MP

    更新日期:2011-12-01 00:00:00

  • Accurate event-driven motion compensation in high-resolution PET incorporating scattered and random events.

    abstract::With continuing improvements in spatial resolution of positron emission tomography (PET) scanners, small patient movements during PET imaging become a significant source of resolution degradation. This work develops and investigates a comprehensive formalism for accurate motion-compensated reconstruction which at the ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2008.917248

    authors: Rahmim A,Dinelle K,Cheng JC,Shilov MA,Segars WP,Lidstone SC,Blinder S,Rousset OG,Vajihollahi H,Tsui BM,Wong DF,Sossi V

    更新日期:2008-08-01 00:00:00

  • Free-breathing diffusion tensor imaging and tractography of the human heart in healthy volunteers using wavelet-based image fusion.

    abstract::Free-breathing cardiac diffusion tensor imaging (DTI) is a promising but challenging technique for the study of fiber structures of the human heart in vivo. This work proposes a clinically compatible and robust technique to provide three-dimensional (3-D) fiber architecture properties of the human heart. To this end, ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2014.2356792

    authors: Wei H,Viallon M,Delattre BM,Moulin K,Yang F,Croisille P,Zhu Y

    更新日期:2015-01-01 00:00:00

  • Use of needle track detection to quantify the displacement of stranded seeds following prostate brachytherapy.

    abstract::We aim to compute the movement of permanent stranded implant brachytherapy radioactive sources (seeds) in the prostate from the planned seed distribution to the intraoperative fluoroscopic distribution, and then to the postimplant computed tomography (CT) distribution. We present a novel approach to matching the seeds...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2011.2178254

    authors: Lobo JR,Moradi M,Chng N,Dehghan E,Morris WJ,Fichtinger G,Salcudean SE

    更新日期:2012-03-01 00:00:00

  • Including anatomical and functional information in MC simulation of PET and SPECT brain studies. Brain-VISET: a voxel-based iterative method.

    abstract::Monte Carlo (MC) simulation provides a flexible and robust framework to efficiently evaluate and optimize image processing methods in emission tomography. In this work we present Brain-VISET (Voxel-based Iterative Simulation for Emission Tomography), a method that aims to simulate realistic [ (99m) Tc]-SPECT and [ (18...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2014.2326041

    authors: Marti-Fuster B,Esteban O,Thielemans K,Setoain X,Santos A,Ros D,Pavia J

    更新日期:2014-10-01 00:00:00

  • A characterization of the geometric architecture of the peritalar joint complex via MRI: an aid to the classification of foot type.

    abstract::The purpose of this work is to study the architecture of the rearfoot using in vivo MR image data. Each data set used in this study is made of sixty sagittal slices of the foot acquired in a 1.5-T commercial GE MR system. We use the live-wire method to delineate boundaries and form the surfaces of the bones. In the fi...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.802753

    authors: Stindel E,Udupa JK,Hirsch BE,Odhner D

    更新日期:1999-09-01 00:00:00

  • Lumen segmentation and motion estimation in B-mode and contrast-enhanced ultrasound images of the carotid artery in patients with atherosclerotic plaque.

    abstract::In standard B-mode ultrasound (BMUS), segmentation of the lumen of atherosclerotic carotid arteries and studying the lumen geometry over time are difficult owing to irregular lumen shapes, noise, artifacts, and echolucent plaques. Contrast enhanced ultrasound (CEUS) improves lumen visualization, but lumen segmentation...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2014.2372784

    authors: Carvalho DD,Akkus Z,van den Oord SC,Schinkel AF,van der Steen AF,Niessen WJ,Bosch JG,Klein S

    更新日期:2015-04-01 00:00:00

  • Three-dimensional segmentation and growth-rate estimation of small pulmonary nodules in helical CT images.

    abstract::Small pulmonary nodules are a common radiographic finding that presents an important diagnostic challenge in contemporary medicine. While pulmonary nodules are the major radiographic indicator of lung cancer, they may also be signs of a variety of benign conditions. Measurement of nodule growth rate over time has been...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2003.817785

    authors: Kostis WJ,Reeves AP,Yankelevitz DF,Henschke CI

    更新日期:2003-10-01 00:00:00

  • Improved SPECT quantitation using fully three-dimensional iterative spatially variant scatter response compensation.

    abstract::The quality and quantitative accuracy of iteratively reconstructed SPECT images improves when better point spread function (PSF) models of the gamma camera are used during reconstruction. Here, inclusion in the PSF model of photon crosstalk between different slices caused by limited gamma camera resolution and scatter...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.511752

    authors: Beekman FJ,Kamphuis C,Viergever MA

    更新日期:1996-01-01 00:00:00

  • 3-D Contrast Source Inversion-Electrical Properties Tomography.

    abstract::Contrast source inversion-electrical properties tomography (CSI-EPT) is an iterative reconstruction method to retrieve the electrical properties (EPs) of tissues from magnetic resonance data. The method is based on integral representations of the electromagnetic field and has been shown to allow EP reconstructions of ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2018.2816125

    authors: Leijsen RL,Brink WM,van den Berg CAT,Webb AG,Remis RF

    更新日期:2018-09-01 00:00:00

  • Spatiotemporal forward solution of the EEG and MEG using network modeling.

    abstract::Dynamic systems have proven to be well suited to describe a broad spectrum of human coordination behavior such synchronization with auditory stimuli. Simultaneous measurements of the spatiotemporal dynamics of electroencephalographic (EEG) and magnetoencephalographic (MEG) data reveals that the dynamics of the brain s...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2002.1009385

    authors: Jirsa VK,Jantzen KJ,Fuchs A,Kelso JA

    更新日期:2002-05-01 00:00:00

  • Ultrafast Doppler imaging of blood flow dynamics in the myocardium.

    abstract::Imaging intramyocardial vascular flows in real-time could strongly help to achieve better diagnostic of cardiovascular diseases. To date, no standard imaging modality allows describing accurately myocardial blood flow dynamics with good spatial and temporal resolution. We recently introduced a novel ultrasonic Doppler...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2012.2203316

    authors: Osmanski BF,Pernot M,Montaldo G,Bel A,Messas E,Tanter M

    更新日期:2012-08-01 00:00:00