Ultrafast Doppler imaging of blood flow dynamics in the myocardium.

Abstract:

:Imaging intramyocardial vascular flows in real-time could strongly help to achieve better diagnostic of cardiovascular diseases. To date, no standard imaging modality allows describing accurately myocardial blood flow dynamics with good spatial and temporal resolution. We recently introduced a novel ultrasonic Doppler imaging technique based on compounded plane waves transmissions at ultrafast frame rate. The high sensitivity of this ultrafast Doppler technique permits to image the intramyocardial blood flow and its dynamics. A dedicated demodulation-filtering process is implemented to compensate for the large tissue velocity of the myocardium during the cardiac cycle. A signed power Doppler processing provides the discrimination between arterial and venous flows. Experiments were performed in vivo in a large animal open chest model ( N = 5 sheep) using a conventional ultrasonic probe placed at the surface of the heart. Results show the capability of the technique to image intramyocardial vascular flows in normal physiological conditions with good spatial (200 μm) and temporal resolution (10 ms). Flow dynamics over the cardiac cycle were investigated and the imaging method demonstrated a phase opposition of flow waveforms between arterial and venous flows. Finally, ultrafast Doppler combined with tissue motion compensation was found able to reveal vascular flow disruption in ischemic regions during occlusion of the main diagonal coronary artery.

journal_name

IEEE Trans Med Imaging

authors

Osmanski BF,Pernot M,Montaldo G,Bel A,Messas E,Tanter M

doi

10.1109/TMI.2012.2203316

subject

Has Abstract

pub_date

2012-08-01 00:00:00

pages

1661-8

issue

8

eissn

0278-0062

issn

1558-254X

journal_volume

31

pub_type

杂志文章
  • Three-dimensional microwave breast imaging: dispersive dielectric properties estimation using patient-specific basis functions.

    abstract::Breast imaging via microwave tomography involves estimating the distribution of dielectric properties within the patient's breast on a discrete mesh. The number of unknowns in the discrete mesh can be very large for 3-D imaging, and this results in computational challenges. We propose a new approach where the discrete...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2008.2008959

    authors: Winters DW,Shea JD,Kosmas P,Van Veen BD,Hagness SC

    更新日期:2009-07-01 00:00:00

  • Prospective Respiration Detection in Magnetic Resonance Imaging by a Non-Interfering Noise Navigator.

    abstract::Passive monitoring of the thermal noise variances of the channels of a receive array was shown to reveal respiratory motion of the underlying anatomy, a so called "noise navigator". There is, however, an inevitable trade off between the accuracy and temporal resolution of the noise navigator due to its passive nature....

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2018.2808699

    authors: Navest RJM,Andreychenko A,Lagendijk JJW,van den Berg CAT

    更新日期:2018-08-01 00:00:00

  • Lumen segmentation and motion estimation in B-mode and contrast-enhanced ultrasound images of the carotid artery in patients with atherosclerotic plaque.

    abstract::In standard B-mode ultrasound (BMUS), segmentation of the lumen of atherosclerotic carotid arteries and studying the lumen geometry over time are difficult owing to irregular lumen shapes, noise, artifacts, and echolucent plaques. Contrast enhanced ultrasound (CEUS) improves lumen visualization, but lumen segmentation...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2014.2372784

    authors: Carvalho DD,Akkus Z,van den Oord SC,Schinkel AF,van der Steen AF,Niessen WJ,Bosch JG,Klein S

    更新日期:2015-04-01 00:00:00

  • Axial resolution and the value of interpolating scan in multislice positron computed tomography.

    abstract::We have calculated the aperture function of a positron computed tomograph (PCT) with computer simulation, and evaluated the axial resolution of a multislice PCT, Positologica III, both theoretically and experimentally. The axial point spread function (PSF) was approximately a triangle at or near the center of the fiel...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.1985.4307692

    authors: Senda M,Yonekura Y,Tamaki N,Tanaka Y,Komori M,Minato K,Konishi J,Torizuka K

    更新日期:1985-01-01 00:00:00

  • Breast tissue density quantification via digitized mammograms.

    abstract::Studies reported in the literature indicate that breast cancer risk is associated with mammographic densities. An objective, repeatable, and a quantitative measure of risk derived from mammographic densities will be of considerable use in recommending alternative screening paradigms and/or preventive measures. However...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.938247

    authors: Saha PK,Udupa JK,Conant EF,Chakraborty DP,Sullivan D

    更新日期:2001-08-01 00:00:00

  • Intrathoracic airway trees: segmentation and airway morphology analysis from low-dose CT scans.

    abstract::The segmentation of the human airway tree from volumetric computed tomography (CT) images builds an important step for many clinical applications and for physiological studies. Previously proposed algorithms suffer from one or several problems: leaking into the surrounding lung parenchyma, the need for the user to man...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2005.857654

    authors: Tschirren J,Hoffman EA,McLennan G,Sonka M

    更新日期:2005-12-01 00:00:00

  • An Inverse Problems Approach to MR-EPT Image Reconstruction.

    abstract::Magnetic Resonance-Electrical Properties Tomography (MR-EPT) is an imaging modality that maps the spatial distribution of the electrical conductivity and permittivity using standard MRI systems. The presence of a body within the scanner alters the RF field, and by mapping these alterations it is possible to recover th...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2015.2466082

    authors: Borsic A,Perreard I,Mahara A,Halter RJ

    更新日期:2016-01-01 00:00:00

  • Twenty new digital brain phantoms for creation of validation image data bases.

    abstract::Simulations provide a way of generating data where ground truth is known, enabling quantitative testing of image processing methods. In this paper, we present the construction of 20 realistic digital brain phantoms that can be used to simulate medical imaging data. The phantoms are made from 20 normal adults to take i...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2006.883453

    authors: Aubert-Broche B,Griffin M,Pike GB,Evans AC,Collins DL

    更新日期:2006-11-01 00:00:00

  • Collimator optimization for detection and quantitation tasks: application to gallium-67 imaging.

    abstract::We describe a new approach to the problem of collimator optimization in nuclear medicine; our methodology is illustrated for the challenging case of gallium-67 imaging. Collimator-design methods based on empirical rules, such as specification of an allowable level of single-septal penetration (SSP) at a fixed energy, ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2005.857211

    authors: Moore SC,Foley Kijewski M,El Fakhri G

    更新日期:2005-10-01 00:00:00

  • SNORE: spike noise removal and detection.

    abstract::A method for detection and removal of random spike noise in magnetic resonance (MR) raw data (k-space data) is described. This method would reduce or eliminate the corduroy-type and higher than usual level artifacts in MR images resulting from random spike noise in k-space data. The method described involves applying ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.276151

    authors: Foo TF,Grigsby NS,Mitchell JD,Slayman BE

    更新日期:1994-01-01 00:00:00

  • Fast local trust region technique for diffusion tensor registration using exact reorientation and regularization.

    abstract::Diffusion tensor imaging is widely used in brain connectivity research. As more and more studies recruit large numbers of subjects, it is important to design registration methods which are not only theoretically rigorous, but also computationally efficient. However, the requirement of reorienting diffusion tensors com...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2013.2274051

    authors: Li J,Shi Y,Tran G,Dinov I,Wang DJ,Toga A

    更新日期:2014-05-01 00:00:00

  • Characterization of visually similar diffuse diseases from B-scan liver images using nonseparable wavelet transform.

    abstract::This paper describes a new approach for texture characterization, based on nonseparable wavelet decomposition, and its application for the discrimination of visually similar diffuse diseases of liver. The proposed feature-extraction algorithm applies nonseparable quincunx wavelet transform and uses energies of the tra...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.730399

    authors: Mojsilović A,Popović M,Marković S,Krstić M

    更新日期:1998-08-01 00:00:00

  • Semiautomated border tracking of cine echocardiographic ventnrcular images.

    abstract::Two-dimensional ultrasound sector scans of the left ventricle (LV) are commonly used to diagnose cardiac mechanical function. Present quantification procedures of wall motion by this technique entail inaccuracies, mainly due to relatively poor image quality and the absence of a definition of the relative position of t...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.1987.4307836

    authors: Adam D,Hareuveni O,Sideman S

    更新日期:1987-01-01 00:00:00

  • Ultrafast Ultrasound Imaging With Cascaded Dual-Polarity Waves.

    abstract::Ultrafast ultrasound imaging using plane or diverging waves, instead of focused beams, has advanced greatly the development of novel ultrasound imaging methods for evaluating tissue functions beyond anatomical information. However, the sonographic signal-to-noise ratio (SNR) of ultrafast imaging remains limited due to...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2017.2781261

    authors: Zhang Y,Guo Y,Lee WN

    更新日期:2018-04-01 00:00:00

  • Difference-Frequency Ultrasound Imaging With Non-Linear Contrast.

    abstract::Conventional ultrasound imaging is based on the scattering of sound from inhomogeneities in the density and the speed of sound and is often used in medicine to resolve pathologic compared to normal tissue. Here we demonstrate a difference-frequency ultrasound (dfUS) imaging method that is based on the interaction of t...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2019.2957280

    authors: Li Y,Polyak D,Johnson E,Yecies D,Shevidi S,de la Zerda A,Gephart MH,Chu S

    更新日期:2020-05-01 00:00:00

  • Computer-Aided Cervical Cancer Diagnosis Using Time-Lapsed Colposcopic Images.

    abstract::Cervical cancer causes the fourth most cancer-related deaths of women worldwide. Early detection of cervical intraepithelial neoplasia (CIN) can significantly increase the survival rate of patients. In this paper, we propose a deep learning framework for the accurate identification of LSIL+ (including CIN and cervical...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2020.2994778

    authors: Li Y,Chen J,Xue P,Tang C,Chang J,Chu C,Ma K,Li Q,Zheng Y,Qiao Y

    更新日期:2020-11-01 00:00:00

  • Metrics for Assessing the Similarity of Microwave Breast Imaging Scans of Healthy Volunteers.

    abstract::Microwave radar imaging is promising as a complementary medical imaging modality. However, the unique nature of the images means interpretation can be difficult. As a result, it is important to understand the sources of image differences, and how much variability is inherent in the imaging system itself. To address th...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2018.2806878

    authors: Lavoie BR,Bourqui J,Fear EC,Okoniewski M

    更新日期:2018-08-01 00:00:00

  • Anti-aliasing weighting functions for single-slice helical CT.

    abstract::Spatially variant longitudinal aliasing plagues most volumes reconstructed from single-slice helical computed tomography data, and its presence can degrade resolution and distort image structures. We have recently developed a Fourier-based approach to longitudinal interpolation in helical computed tomography that can,...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2002.803104

    authors: La Rivière PJ,Pan X

    更新日期:2002-08-01 00:00:00

  • Computer-aided stereotactic functional neurosurgery enhanced by the use of the multiple brain atlas database.

    abstract::This paper introduces a computer-aided atlas-based functional neurosurgery methodology and describes NeuroPlanner, a software system which supports it. NeuroPlanner provides four groups of functions: 1) data-related for data reading, interpolation, reformatting, and image processing; 2) atlas-related for multiple atla...

    journal_title:IEEE transactions on medical imaging

    pub_type: 信件

    doi:10.1109/42.832961

    authors: Nowinski WL,Yang GL,Yeo TT

    更新日期:2000-01-01 00:00:00

  • Joint Design of Excitation k-Space Trajectory and RF Pulse for Small-Tip 3D Tailored Excitation in MRI.

    abstract::We propose a new method for the joint design of k-space trajectory and RF pulse in 3D small-tip tailored excitation. Designing time-varying RF and gradient waveforms for a desired 3D target excitation pattern in MRI poses a non-linear, non-convex, constrained optimization problem with relatively large problem size tha...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2015.2478880

    authors: Hao S,Fessler JA,Noll DC,Nielsen JF

    更新日期:2016-02-01 00:00:00

  • Optimal rebinning of time-of-flight PET data.

    abstract::Time-of-flight (TOF) positron emission tomography (PET) scanners offer the potential for significantly improved signal-to-noise ratio (SNR) and lesion detectability in clinical PET. However, fully 3D TOF PET image reconstruction is a challenging task due to the huge data size. One solution to this problem is to rebin ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2011.2149537

    authors: Ahn S,Cho S,Li Q,Lin Y,Leahy RM

    更新日期:2011-10-01 00:00:00

  • Estimating kinetic parameter maps from dynamic contrast-enhanced MRI using spatial prior knowledge.

    abstract::Dynamic contrast-enhanced magnetic resonance (DCE-MR) imaging can be used to study microvascular structure in vivo by monitoring the abundance of an injected diffusible contrast agent over time. The resulting spatially resolved intensity-time curves are usually interpreted in terms of kinetic parameters obtained by fi...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2009.2019957

    authors: Kelm BM,Menze BH,Nix O,Zechmann CM,Hamprecht FA

    更新日期:2009-10-01 00:00:00

  • Joint Multi-Modal Longitudinal Regression and Classification for Alzheimer's Disease Prediction.

    abstract::Alzheimer's disease (AD) is a serious neurodegenerative condition that affects millions of individuals across the world. As the average age of individuals in the United States and the world increases, the prevalence of AD will continue to grow. To address this public health problem, the research community has develope...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2019.2958943

    authors: Brand L,Nichols K,Wang H,Shen L,Huang H

    更新日期:2020-06-01 00:00:00

  • Pulmonary Lobe Segmentation With Probabilistic Segmentation of the Fissures and a Groupwise Fissure Prior.

    abstract::A fully automated, unsupervised lobe segmentation algorithm is presented based on a probabilistic segmentation of the fissures and the simultaneous construction of a populationmodel of the fissures. A two-class probabilistic segmentation segments the lung into candidate fissure voxels and the surrounding parenchyma. T...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2017.2688377

    authors: Bragman FJS,McClelland JR,Jacob J,Hurst JR,Hawkes DJ

    更新日期:2017-08-01 00:00:00

  • Novel EIS postprocessing algorithm for breast cancer diagnosis.

    abstract::A new postprocessing algorithm was developed for the diagnosis of breast cancer using electrical impedance scanning. This algorithm automatically recognizes bright focal spots in the conductivity map of the breast. Moreover, this algorithm discriminates between malignant and benign/normal tissues using two main predic...

    journal_title:IEEE transactions on medical imaging

    pub_type: 信件

    doi:10.1109/TMI.2002.800605

    authors: Glickman YA,Filo O,Nachaliel U,Lenington S,Amin-Spector S,Ginor R

    更新日期:2002-06-01 00:00:00

  • Measurement of mean and variance of velocity fields within each voxel by NMR imaging.

    abstract::If a flow field exists within an object that is being imaged, there could be a velocity spectrum in each voxel due to the finite voxel size. Consequently, the mean value and the variance of velocity in each voxel can be defined and used to describe the velocity spectrum. An NMR (nuclear magnetic resonance) imaging tec...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.14520

    authors: Xiang QS,Nalcioglu O

    更新日期:1988-01-01 00:00:00

  • A Krasnoselskii-Mann Algorithm With an Improved EM Preconditioner for PET Image Reconstruction.

    abstract::This paper presents a preconditioned Krasnoselskii-Mann (KM) algorithm with an improved EM preconditioner (IEM-PKMA) for higher-order total variation (HOTV) regularized positron emission tomography (PET) image reconstruction. The PET reconstruction problem can be formulated as a three-term convex optimization model co...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2019.2898271

    authors: Lin Y,Schmidtlein CR,Li Q,Li S,Xu Y

    更新日期:2019-09-01 00:00:00

  • Spatial transformation of DWI data using non-negative sparse representation.

    abstract::This paper presents an algorithm to transform and reconstruct diffusion-weighted imaging (DWI) data for alignment of micro-structures in association with spatial transformations. The key idea is to decompose the diffusion signal profile, a function defined on a unit sphere, into a series of weighted diffusion basis fu...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2012.2204766

    authors: Yap PT,Shen D

    更新日期:2012-11-01 00:00:00

  • Automatic 3-D segmentation of internal structures of the head in MR images using a combination of similarity and free-form transformations: Part I, Methodology and validation on normal subjects.

    abstract::The study presented in this paper tests the hypothesis that the combination of a global similarity transformation and local free-form deformations can be used for the accurate segmentation of internal structures in MR images of the brain. To quantitatively evaluate our approach, the entire brain, the cerebellum, and t...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.811271

    authors: Dawant BM,Hartmann SL,Thirion JP,Maes F,Vandermeulen D,Demaerel P

    更新日期:1999-10-01 00:00:00

  • Statistical distributions of DCT coefficients and their application to an interframe compression algorithm for 3-D medical images.

    abstract::Displacement estimated interframe (DEI) coding, a coding scheme for 3-D medical image data sets such as X-ray computed tomography (CT) or magnetic resonance (MR) images, is presented. To take advantage of the correlation between contiguous slices, a displacement-compensated difference image based on the previous image...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.241875

    authors: Lee H,Kim Y,Rowberg AH,Riskin EA

    更新日期:1993-01-01 00:00:00