Abstract:
:We describe a new approach to the problem of collimator optimization in nuclear medicine; our methodology is illustrated for the challenging case of gallium-67 imaging. Collimator-design methods based on empirical rules, such as specification of an allowable level of single-septal penetration (SSP) at a fixed energy, are especially inappropriate for radionuclides characterized by an abundance of high-energy contaminant photons that scatter in the patient, collimator, and/or detector before detection within one of a few photopeak energy windows. Lead X-rays produced in the collimator are an additional source of contamination. We designed optimal collimation for 67Ga based on relevant clinical imaging tasks and a realistic simulation of photon transport in a phantom, collimator, and detector. Collimator designs were compared on the basis of performance in lesion detection, as predicted by a three-channel Hotelling observer (CHO), as well as in tumor and background activity estimation (EST), quantified by task-specific signal-to-noise ratios (SNRs). The optimal values of collimator lead content were 22.0 and 23.8 g/cm2, respectively, for CHO and EST, while the optimal geometric resolution values were 1.8 and 1.6 cm full-width at half-maximum (FWHM), respectively, at a distance of 23.5 cm. The resolution of a commercially available medium-energy low-penetration collimator (MELP) is 1.9 cm FWHM at this distance. The optimal values for SSP at 300 keV were 7.3% and 5.8% based on CHO and EST, respectively, compared to 5.2% for the MELP collimator. Compared with the commercial MELP collimator, the 67Ga collimator optimized for tumor detection or activity estimation tasks provided improved geometric spatial resolution with reduced geometric efficiency and, surprisingly, allowed an increased level of single-septal penetration.
journal_name
IEEE Trans Med Imagingjournal_title
IEEE transactions on medical imagingauthors
Moore SC,Foley Kijewski M,El Fakhri Gdoi
10.1109/TMI.2005.857211subject
Has Abstractpub_date
2005-10-01 00:00:00pages
1347-56issue
10eissn
0278-0062issn
1558-254Xjournal_volume
24pub_type
杂志文章abstract::Respiratory motion remains a significant source of errors in treatment planning for the thorax and upper abdomen. Recently, we proposed a method to estimate two-dimensional (2-D) object motion from a sequence of slowly rotating X-ray projection views, which we called deformation from orbiting views (DOVs). In this met...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2006.889719
更新日期:2007-02-01 00:00:00
abstract::In this paper, we present a wavelet-based multigrid approach to solve the perturbation equation encountered in optical tomography. With this scheme, the unknown image, the data, as well as the weight matrix are all represented by wavelet expansions, thus yielding a multiresolution representation of the original pertur...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.563666
更新日期:1997-04-01 00:00:00
abstract::The high-frequency transceiver array based on the microstrip transmission line design is a promising technique for ultrahigh field magnetic resonance imaging (MRI) signal excitation and reception. However, with the increase of radio-frequency (RF) channels, the size of the ground plane in each microstrip coil element ...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2009.2033597
更新日期:2010-01-01 00:00:00
abstract::Segmentation of the wrist bones in CT images has been frequently used in different clinical applications including arthritis evaluation, bone age assessment and image-guided interventions. The major challenges include non-uniformity and spongy textures of the bone tissue as well as narrow inter-bone spaces. In this wo...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2016.2529500
更新日期:2016-08-01 00:00:00
abstract::An iterative algorithm is introduced which can compute and subtract the scatter bias. It is assumed that the scatter-free image is spatially bounded and anything outside the boundary is the result of recorded scattered photons. This information and the fact that the scatter distribution does not have appreciable high-...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.20362
更新日期:1989-01-01 00:00:00
abstract::The hybrid magnetic resonance (MR)/X-ray suite (XMR) is a recently introduced imaging solution that provides new possibilities for guidance of cardiovascular catheterization procedures. We have previously described and validated a technique based on optical tracking to register MR and X-ray images obtained from the sl...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2005.856731
更新日期:2005-11-01 00:00:00
abstract::We describe a matched subspace detection algorithm to assist in the detection of small tumors in dynamic positron emission tomography (PET) images. The algorithm is designed to differentiate tumors from background using the time activity curves (TACs) that characterize the uptake of PET tracers. TACs are modeled using...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2008.929105
更新日期:2009-02-01 00:00:00
abstract::Building a data-driven model to localize the origin of ventricular activation from 12-lead electrocardiograms (ECG) requires addressing the challenge of large anatomical and physiological variations across individuals. The alternative of a patient-specific model is, however, difficult to implement in clinical practice...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2018.2880092
更新日期:2019-05-01 00:00:00
abstract::Imaging intramyocardial vascular flows in real-time could strongly help to achieve better diagnostic of cardiovascular diseases. To date, no standard imaging modality allows describing accurately myocardial blood flow dynamics with good spatial and temporal resolution. We recently introduced a novel ultrasonic Doppler...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2012.2203316
更新日期:2012-08-01 00:00:00
abstract::Two-dimensional ultrasound sector scans of the left ventricle (LV) are commonly used to diagnose cardiac mechanical function. Present quantification procedures of wall motion by this technique entail inaccuracies, mainly due to relatively poor image quality and the absence of a definition of the relative position of t...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.1987.4307836
更新日期:1987-01-01 00:00:00
abstract::Ultrashort echo time imaging on clinical systems is still limited by the rather long radio frequency switching times achievable with standard front end concepts. In this contribution, an independent parallel receive-only system is interfaced to an unmodified clinical MRI system, enabling imaging of species with ultras...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2019.2924057
更新日期:2020-01-01 00:00:00
abstract::A new type of classifier combining an unsupervised and a supervised model was designed and applied to classification of malignant and benign masses on mammograms. The unsupervised model was based on an adaptive resonance theory (ART2) network which clustered the masses into a number of separate classes. The classes we...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.819327
更新日期:1999-12-01 00:00:00
abstract::We propose a joint information approach for automatic analysis of 2D echocardiography (echo) data. The approach combines a priori images, their segmentations and patient diagnostic information within a unified framework to determine various clinical parameters, such as cardiac chamber volumes, and cardiac disease labe...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2016.2593900
更新日期:2017-01-01 00:00:00
abstract::This paper presents a method to reconstruct moving objects from cone beam X-ray projections acquired during a single rotational run using a given motion vector field. The method is applicable to voxel driven cone-beam filtered back-projection reconstruction approaches. Here, a formulation based on the algorithm of Fel...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/tmi.2006.876147
更新日期:2006-07-01 00:00:00
abstract::The watershed transform has interesting properties that make it useful for many different image segmentation applications: it is simple and intuitive, can be parallelized, and always produces a complete division of the image. However, when applied to medical image analysis, it has important drawbacks (oversegmentation...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2004.824224
更新日期:2004-04-01 00:00:00
abstract::Cone beam X-ray luminescence computed tomography (CB-XLCT) is a promising imaging technique in studying the physiological and pathological processes in small animals. However, the dynamic bio-distributions of probes in small animal, especially in adjacent targets are still hard to be captured directly from dynamic CB-...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2019.2917026
更新日期:2019-12-01 00:00:00
abstract::3D Statistical Shape Models (3D-SSM) are widely used for medical image segmentation. However, during segmentation, they typically perform a very limited unidirectional search for suitable landmark positions in the image, relying on weak learners or use-case specific appearance models that solely take local image infor...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2016.2600502
更新日期:2017-01-01 00:00:00
abstract::Magnetic particle imaging allows to determine the spatial distribution of magnetic nanoparticles in vivo. The system matrix in magnetic particle imaging is commonly acquired in a tedious calibration scan and requires to measure the system response at numerous positions in the field-of-view. In this paper, we propose a...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2013.2258029
更新日期:2013-08-01 00:00:00
abstract::Glaucoma is a leading cause of irreversible blindness. Accurate segmentation of the optic disc (OD) and optic cup (OC) from fundus images is beneficial to glaucoma screening and diagnosis. Recently, convolutional neural networks demonstrate promising progress in the joint OD and OC segmentation. However, affected by t...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2019.2899910
更新日期:2019-11-01 00:00:00
abstract::A fully automated, unsupervised lobe segmentation algorithm is presented based on a probabilistic segmentation of the fissures and the simultaneous construction of a populationmodel of the fissures. A two-class probabilistic segmentation segments the lung into candidate fissure voxels and the surrounding parenchyma. T...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2017.2688377
更新日期:2017-08-01 00:00:00
abstract::We propose a novel, physics-based method for detecting multi-scale tubular features in ultrasound images. The detector is based on a Hessian-matrix eigenvalue method, but unlike previous work, our detector is guided by an optimal model of vessel-like structures with respect to the ultrasound-image formation process. O...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2014.2340912
更新日期:2015-01-01 00:00:00
abstract::Risk stratification (characterization) of tumors from radiology images can be more accurate and faster with computer-aided diagnosis (CAD) tools. Tumor characterization through such tools can also enable non-invasive cancer staging, prognosis, and foster personalized treatment planning as a part of precision medicine....
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2019.2894349
更新日期:2019-08-01 00:00:00
abstract::A common method of increasing hemodynamic response (SNR) in functional magnetic resonance imaging (fMRI) is to average signal timecourses across voxels. This technique is potentially problematic because the hemodynamic response may vary across the brain. Such averaging may destroy significant features in the temporal ...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2003.819922
更新日期:2004-01-01 00:00:00
abstract::In magnetic resonance imaging (MRI), spatial resolution is limited by several factors such as acquisition time, short physiological phenomena, and organ motion. The acquired image usually has higher resolution in two dimensions (the acquisition plane) in comparison with the third dimension, resulting in highly anisotr...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2014.2329271
更新日期:2014-10-01 00:00:00
abstract::This paper presents a fully automated algorithm for segmentation of multiple sclerosis (MS) lesions from multispectral magnetic resonance (MR) images. The method performs intensity-based tissue classification using a stochastic model for normal brain images and simultaneously detects MS lesions as outliers that are no...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.938237
更新日期:2001-08-01 00:00:00
abstract::We propose a method for restoring the underlying true signal in noisy functional images. The Nadaraya-Watson (NW) estimator described in, e.g., [1] is a classical nonparametric estimator for this problem. Since the true scene in many applications contains abrupt changes between pixels of different types, a modificatio...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.906423
更新日期:2001-01-01 00:00:00
abstract::Functional magnetic resonance imaging (fMRI) provides a window on the human brain at work. Spontaneous brain activity measured during resting-state has already provided many insights into brain function. In particular, recent interest in dynamic interactions between brain regions has increased the need for more advanc...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2017.2755369
更新日期:2018-01-01 00:00:00
abstract::We demonstrate three-dimensional intravascular flow imaging compatible with routine clinical image acquisition workflow by means of megahertz (MHz) intravascular Doppler Optical Coherence Tomography (OCT). The OCT system relies on a 1.1 mm diameter motorized imaging catheter and a 1.5 MHz Fourier Domain Mode Locked (F...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2019.2948258
更新日期:2020-05-01 00:00:00
abstract::In single photon emission computed tomography (SPECT), every reconstruction algorithm must use some model for the response of the gamma camera to emitted gamma-rays. The true camera response is both spatially variant and object dependent. These two properties result from the effects of scatter, septal penetration, and...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.126914
更新日期:1992-01-01 00:00:00
abstract::Psoriasis is a chronic inflammatory skin disease that affects over 3% of the population. Various methods are currently used to evaluate psoriasis severity and to monitor therapeutic response. The PASI system of scoring is widely used for evaluating psoriasis severity. It employs a visual analogue scale to score the th...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2012.2236349
更新日期:2013-04-01 00:00:00