Semiautomated border tracking of cine echocardiographic ventnrcular images.

Abstract:

:Two-dimensional ultrasound sector scans of the left ventricle (LV) are commonly used to diagnose cardiac mechanical function. Present quantification procedures of wall motion by this technique entail inaccuracies, mainly due to relatively poor image quality and the absence of a definition of the relative position of the probe and the heart. The poor quality dictates subjective determination of the myocardial edges, while the absence of a position vector increases the errors in the calculations of wall displacement, LV blood volume, and ejection fraction. An improved procedure is proposed here for automatic myocardial border tracking (AMBT) of the endocardial and epicardial edges in a sequence of video images. The procedure includes nonlinear filtering of whole images, debiasing of gray levels, and location-dependent contrast stretching. The AMBT algorithm is based upon tracking movement of a small number of predefined set of points, which are manually defined on the two myocardial borders. Information from one image is used, by utilizing predetermined statistical criteria to iteratively search and detect the border points on the next one. Border contours are reconstructed by Spline interpolation of the border points. The AMBT procedure is tested by comparing processed sequences of cine echocardiographic scan images to manual tracings by an objective observer and to results from previously published data.

journal_name

IEEE Trans Med Imaging

authors

Adam D,Hareuveni O,Sideman S

doi

10.1109/TMI.1987.4307836

subject

Has Abstract

pub_date

1987-01-01 00:00:00

pages

266-71

issue

3

eissn

0278-0062

issn

1558-254X

journal_volume

6

pub_type

杂志文章
  • Diffuse optical tomography enhanced by clustered sparsity for functional brain imaging.

    abstract::Diffuse optical tomography (DOT) is a noninvasive technique which measures hemodynamic changes in the tissue with near infrared light, which has been increasingly used to study brain functions. Due to the nature of light propagation in the tissue, the reconstruction problem is severely ill-posed. For linearized DOT pr...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2014.2338214

    authors: Chen C,Tian F,Liu H,Huang J

    更新日期:2014-12-01 00:00:00

  • Electrical impedance tomography of translationally uniform cylindrical objects with general cross-sectional boundaries.

    abstract::An algorithm is developed for electrical impedance tomography (EIT) of finite cylinders with general cross-sectional boundaries and translationally uniform conductivity distributions. The electrodes for data collection are assumed to be placed around a cross-sectional plane; therefore, the axial variation of the bound...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.52982

    authors: Ider YZ,Gencer NG,Atalar E,Tosun H

    更新日期:1990-01-01 00:00:00

  • Three-dimensional segmentation and growth-rate estimation of small pulmonary nodules in helical CT images.

    abstract::Small pulmonary nodules are a common radiographic finding that presents an important diagnostic challenge in contemporary medicine. While pulmonary nodules are the major radiographic indicator of lung cancer, they may also be signs of a variety of benign conditions. Measurement of nodule growth rate over time has been...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2003.817785

    authors: Kostis WJ,Reeves AP,Yankelevitz DF,Henschke CI

    更新日期:2003-10-01 00:00:00

  • A Predictive Model of Vertebral Trabecular Anisotropy From Ex Vivo Micro-CT.

    abstract::Spine-related disorders are amongst the most frequently encountered problems in clinical medicine. For several applications such as 1) to improve the assessment of the strength of the spine, as well as 2) to optimize the personalization of spinal interventions, image-based biomechanical modeling of the vertebrae is ex...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2014.2387114

    authors: Lekadir K,Hoogendoorn C,Hazrati-Marangalou J,Taylor Z,Noble C,van Rietbergen B,Frangi AF

    更新日期:2015-08-01 00:00:00

  • Automatic correction of motion artifacts in magnetic resonance images using an entropy focus criterion.

    abstract::We present the use of an entropy focus criterion to enable automatic focusing of motion corrupted magnetic resonance images. We demonstrate the principle using illustrative examples from cooperative volunteers. Our technique can determine unknown patient motion or use knowledge of motion from other measures as a start...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.650886

    authors: Atkinson D,Hill DL,Stoyle PN,Summers PE,Keevil SF

    更新日期:1997-12-01 00:00:00

  • Artificial Neural Network Enhanced Bayesian PET Image Reconstruction.

    abstract::In positron emission tomography (PET) image reconstruction, the Bayesian framework with various regularization terms has been implemented to constrain the radio tracer distribution. Varying the regularizing weight of a maximum a posteriori (MAP) algorithm specifies a lower bound of the tradeoff between variance and sp...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2018.2803681

    authors: Yang B,Ying L,Tang J

    更新日期:2018-06-01 00:00:00

  • Joint Optic Disc and Cup Segmentation Based on Multi-Label Deep Network and Polar Transformation.

    abstract::Glaucoma is a chronic eye disease that leads to irreversible vision loss. The cup to disc ratio (CDR) plays an important role in the screening and diagnosis of glaucoma. Thus, the accurate and automatic segmentation of optic disc (OD) and optic cup (OC) from fundus images is a fundamental task. Most existing methods s...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2018.2791488

    authors: Fu H,Cheng J,Xu Y,Wong DWK,Liu J,Cao X

    更新日期:2018-07-01 00:00:00

  • Head Motion Correction Based on Filtered Backprojection in Helical CT Scanning.

    abstract::Head motion may unexpectedly occur during a CT scan. It thereby results in motion artifacts in a reconstructed image and may lead to a false diagnosis or a failure of diagnosis. To alleviate this motion problem, as a hardware approach, increasing the gantry rotation speed or using an immobilization device is usually c...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2019.2953974

    authors: Jang S,Kim S,Kim M,Son K,Lee KY,Ra JB

    更新日期:2020-05-01 00:00:00

  • Gray-scale skeletonization of small vessels in magnetic resonance angiography.

    abstract::Interpretation of magnetic resonance angiography (MRA) is problematic due to complexities of vascular shape and to artifacts such as the partial volume effect. We present new methods to assist in the interpretation of MRA. These include methods for detection of vessel paths and for determination of branching patterns ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章,评审

    doi:10.1109/42.870662

    authors: Yim PJ,Choyke PL,Summers RM

    更新日期:2000-06-01 00:00:00

  • Singular vectors of a linear imaging system as efficient channels for the bayesian ideal observer.

    abstract::The Bayesian ideal observer provides an absolute upper bound for diagnostic performance of an imaging system and hence should be used for the assessment of image quality whenever possible. However, computation of ideal-observer performance in clinical tasks is difficult since the probability density functions of the d...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2008.2008967

    authors: Park S,Witten JM,Myers KJ

    更新日期:2009-05-01 00:00:00

  • Computer-assisted scan protocol and reconstruction (CASPAR)-reduction of image noise and patient dose.

    abstract::X-ray computed tomography is a powerful medical imaging device. It allows high-resolution 3-D visualization of the human body. However, one drawback is the health risk associated with ionizing radiation. Simply downscaling the radiation intensities over the entire scan results in increased quantum noise. This paper pr...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2009.2034515

    authors: Sperl J,Beque D,Claus B,De Man B,Senzig B,Brokate M

    更新日期:2010-03-01 00:00:00

  • Accelerating parallel transmit array B1 mapping in high field MRI with slice undersampling and interpolation by kriging.

    abstract::Transmit arrays have been developed to mitigate the RF field inhomogeneity commonly observed in high field magnetic resonance imaging (MRI), typically above 3T. To this end, the knowledge of the RF complex-valued B1 transmit-sensitivities of each independent radiating element has become essential. This paper details a...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2014.2322440

    authors: Ferrand G,Luong M,Cloos MA,Amadon A,Wackernagel H

    更新日期:2014-08-01 00:00:00

  • Technique for reduction of truncation artifact in chemical shift images.

    abstract::The authors describe a technique to reduce truncation artifacts in chemical shift images taken for in vivo magnetic resonance spectroscopy by using boundary information available from anatomic images. In this approach, high spatial frequency components are extrapolated from the observed data by making use of the bound...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.97578

    authors: Hu X,Stillman AE

    更新日期:1991-01-01 00:00:00

  • Elastic registration in the presence of intensity variations.

    abstract::We have developed a general-purpose registration algorithm for medical images and volumes. This method models the transformation between images as locally affine but globally smooth. The model also explicitly accounts for local and global variations in image intensities. This approach is built upon a differential mult...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2003.815069

    authors: Periaswamy S,Farid H

    更新日期:2003-07-01 00:00:00

  • Adaptive speckle reduction filter for log-compressed B-scan images.

    abstract::A good statistical model of speckle formation is useful for designing a good adaptive filter for speckle reduction In ultrasound B-scan images. Previously, statistical models have been used, but they failed to account for the log compression of the echo envelope employed by clinical ultrasound systems. Log-compression...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.544498

    authors: Dutt V,Greenleaf JF

    更新日期:1996-01-01 00:00:00

  • Computer-aided stereotactic functional neurosurgery enhanced by the use of the multiple brain atlas database.

    abstract::This paper introduces a computer-aided atlas-based functional neurosurgery methodology and describes NeuroPlanner, a software system which supports it. NeuroPlanner provides four groups of functions: 1) data-related for data reading, interpolation, reformatting, and image processing; 2) atlas-related for multiple atla...

    journal_title:IEEE transactions on medical imaging

    pub_type: 信件

    doi:10.1109/42.832961

    authors: Nowinski WL,Yang GL,Yeo TT

    更新日期:2000-01-01 00:00:00

  • MRI-compatible device for examining brain activation related to stepping.

    abstract::Repetitive and alternating lower limb movements are a specific component of human gait. Due to technical challenges, the neural mechanisms underlying such movements have not been previously studied with functional magnetic resonance imaging. In this study, we present a novel treadmill device employed to investigate th...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2014.2301493

    authors: Martinez M,Villagra F,Loayza F,Vidorreta M,Arrondo G,Luis E,Diaz J,Echeverria M,Fernandez-Seara MA,Pastor MA

    更新日期:2014-05-01 00:00:00

  • A "twisting and bending" model-based nonrigid image registration technique for 3-D ultrasound carotid images.

    abstract::Atherosclerosis at the carotid bifurcation resulting in cerebral emboli is a major cause of ischemic stroke. Most strokes associated with carotid atherosclerosis can be prevented by lifestyle/dietary changes and pharmacological treatments if identified early by monitoring carotid plaque changes. Registration of 3-D ul...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2008.918326

    authors: Nanayakkara ND,Chiu B,Samani A,Spence JD,Samarabandu J,Fenster A

    更新日期:2008-10-01 00:00:00

  • Reconstruction of dielectric permittivity distributions in arbitrary 2-D inhomogeneous biological bodies by a multiview microwave numerical method.

    abstract::A numerical method for microwave imaging of two-dimensional inhomogeneous biological bodies illuminated by TM waves is presented. It is a spatial-domain multiview approach which makes use of the moment method to discretize the integral-equation formulation of inverse scattering. A pseudoinversion technique is applied ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.232251

    authors: Caorsi S,Gragnani GL,Pastorino M

    更新日期:1993-01-01 00:00:00

  • Fast and Accurate Rat Head Motion Tracking With Point Sources for Awake Brain PET.

    abstract::To avoid the confounding effects of anesthesia and immobilization stress in rat brain positron emission tomography (PET), motion tracking-based unrestrained awake rat brain imaging is being developed. In this paper, we propose a fast and accurate rat headmotion tracking method based on small PET point sources. PET poi...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2017.2667889

    authors: Miranda A,Staelens S,Stroobants S,Verhaeghe J

    更新日期:2017-07-01 00:00:00

  • Spatial-resolution enhancement in computed tomography.

    abstract::We propose an approach that combines an asymmetric fan-beam configuration and a new reconstruction algorithm to enhancing spatial resolution in computed tomography (CT). The asymmetric configuration can be achieved by changing the center of rotation (COR) from the conventional symmetric configuration. It does not, how...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/tmi.2004.840846

    authors: Pan X,Yu L,Kao CM

    更新日期:2005-02-01 00:00:00

  • Multi-Task Deep Model With Margin Ranking Loss for Lung Nodule Analysis.

    abstract::Lung cancer is the leading cause of cancer deaths worldwide and early diagnosis of lung nodule is of great importance for therapeutic treatment and saving lives. Automated lung nodule analysis requires both accurate lung nodule benign-malignant classification and attribute score regression. However, this is quite chal...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2019.2934577

    authors: Liu L,Dou Q,Chen H,Qin J,Heng PA

    更新日期:2020-03-01 00:00:00

  • Restoration of retinal images obtained through cataracts.

    abstract::An optical model for imaging the retina through cataracts has been developed. The images are treated as sample functions of stochastic processes. On the basis of the model a homomorphic Weiner filter can be designed that will optimally restore the cataractous image (in the mean-square-error sense). The design of the f...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.41493

    authors: Peli E,Peli T

    更新日期:1989-01-01 00:00:00

  • Three-dimensional segmentation of fluid-associated abnormalities in retinal OCT: probability constrained graph-search-graph-cut.

    abstract::An automated method is reported for segmenting 3-D fluid-associated abnormalities in the retina, so-called symptomatic exudate-associated derangements (SEAD), from 3-D OCT retinal images of subjects suffering from exudative age-related macular degeneration. In the first stage of a two-stage approach, retinal layers ar...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2012.2191302

    authors: Chen X,Niemeijer M,Zhang L,Lee K,Abramoff MD,Sonka M

    更新日期:2012-08-01 00:00:00

  • Discriminative segmentation-based evaluation through shape dissimilarity.

    abstract::Segmentation-based scores play an important role in the evaluation of computational tools in medical image analysis. These scores evaluate the quality of various tasks, such as image registration and segmentation, by measuring the similarity between two binary label maps. Commonly these measurements blend two aspects ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2012.2216281

    authors: Konukoglu E,Glocker B,Ye DH,Criminisi A,Pohl KM

    更新日期:2012-12-01 00:00:00

  • Validation of nonrigid image registration using finite-element methods: application to breast MR images.

    abstract::This paper presents a novel method for validation of nonrigid medical image registration. This method is based on the simulation of physically plausible, biomechanical tissue deformations using finite-element methods. Applying a range of displacements to finite-element models of different patient anatomies generates m...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2002.808367

    authors: Schnabel JA,Tanner C,Castellano-Smith AD,Degenhard A,Leach MO,Hose DR,Hill DL,Hawkes DJ

    更新日期:2003-02-01 00:00:00

  • Spatio-Temporal Tensor Decomposition of a Polyaffine Motion Model for a Better Analysis of Pathological Left Ventricular Dynamics.

    abstract::Given that heart disease can cause abnormal motion dynamics over the cardiac cycle, understanding and quantifying cardiac motion can provide insight for clinicians to aid with diagnosis, therapy planning, and determining prognosis. The goal of this paper is to extract population-specific motion patterns from 3D displa...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2015.2405579

    authors: McLeod K,Sermesant M,Beerbaum P,Pennec X

    更新日期:2015-07-01 00:00:00

  • An explanation of the effects of Squashing in limited angle tomography.

    abstract::The effects of Squashing, an algorithm introduced by J.A. Reeds and L.A. Shepp (see ibid., vol.MI-6, no.2, p.89-97, June 1987), are described. It is proven that Squashing induces a weight function upon the projections. Intuitive and numerical evidence is presented showing that this weight function is not desirable at ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.57761

    authors: Olson T,Jaffe JS

    更新日期:1990-01-01 00:00:00

  • SVD compression for magnetic resonance fingerprinting in the time domain.

    abstract::Magnetic resonance (MR) fingerprinting is a technique for acquiring and processing MR data that simultaneously provides quantitative maps of different tissue parameters through a pattern recognition algorithm. A predefined dictionary models the possible signal evolutions simulated using the Bloch equations with differ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2014.2337321

    authors: McGivney DF,Pierre E,Ma D,Jiang Y,Saybasili H,Gulani V,Griswold MA

    更新日期:2014-12-01 00:00:00

  • A direct reconstruction algorithm for electrical impedance tomography.

    abstract::A direct (noniterative) reconstruction algorithm for electrical impedance tomography in the two-dimensional (2-D), cross-sectional geometry is reviewed. New results of a reconstruction of a numerically simulated phantom chest are presented. The algorithm is based on the mathematical uniqueness proof by A. I. Nachman [...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2002.800574

    authors: Mueller JL,Siltanen S,Isaacson D

    更新日期:2002-06-01 00:00:00