Automatic correction of motion artifacts in magnetic resonance images using an entropy focus criterion.

Abstract:

:We present the use of an entropy focus criterion to enable automatic focusing of motion corrupted magnetic resonance images. We demonstrate the principle using illustrative examples from cooperative volunteers. Our technique can determine unknown patient motion or use knowledge of motion from other measures as a starting estimate. The motion estimate is used to compensate the acquired data and is iteratively refined using the image entropy. Entropy focuses the whole image principally by favoring the removal of motion induced ghosts and blurring from otherwise dark regions of the image. Using only the image data, and no special hardware or pulse sequences, we demonstrate correction for arbitrary rigid-body translational motion in the imaging plane and for a single rotation. Extension to three-dimensional (3-D) and more general motion should be possible. The algorithm is able to determine volunteer motion well. The mean absolute deviation between algorithm and navigator-echo-determined motion is comparable to the displacement step size used in the algorithm. Local deviations from the recorded motion or navigator-determined motion are explained and we indicate how enhanced focus criteria may be derived. In all cases we were able to compensate images for patient motion, reducing blurring and ghosting.

journal_name

IEEE Trans Med Imaging

authors

Atkinson D,Hill DL,Stoyle PN,Summers PE,Keevil SF

doi

10.1109/42.650886

subject

Has Abstract

pub_date

1997-12-01 00:00:00

pages

903-10

issue

6

eissn

0278-0062

issn

1558-254X

journal_volume

16

pub_type

杂志文章
  • Compensation for nonuniform resolution using penalized-likelihood reconstruction in space-variant imaging systems.

    abstract::Imaging systems that form estimates using a statistical approach generally yield images with nonuniform resolution properties. That is, the reconstructed images possess resolution properties marked by space-variant and/or anisotropic responses. We have previously developed a space-variant penalty for penalized-likelih...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2003.823063

    authors: Stayman JW,Fessler JA

    更新日期:2004-03-01 00:00:00

  • A direct reconstruction algorithm for electrical impedance tomography.

    abstract::A direct (noniterative) reconstruction algorithm for electrical impedance tomography in the two-dimensional (2-D), cross-sectional geometry is reviewed. New results of a reconstruction of a numerically simulated phantom chest are presented. The algorithm is based on the mathematical uniqueness proof by A. I. Nachman [...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2002.800574

    authors: Mueller JL,Siltanen S,Isaacson D

    更新日期:2002-06-01 00:00:00

  • A task-specific evaluation of three-dimensional image interpolation techniques.

    abstract::Image interpolation is an important operation that is widely used in medical imaging, image processing, and computer graphics. A variety of interpolation methods are available in the literature. However, their systematic evaluation is lacking. In a previous paper, we presented a framework for the task-independent comp...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.759116

    authors: Grevera GJ,Udupa JK,Miki Y

    更新日期:1999-02-01 00:00:00

  • Free-breathing diffusion tensor imaging and tractography of the human heart in healthy volunteers using wavelet-based image fusion.

    abstract::Free-breathing cardiac diffusion tensor imaging (DTI) is a promising but challenging technique for the study of fiber structures of the human heart in vivo. This work proposes a clinically compatible and robust technique to provide three-dimensional (3-D) fiber architecture properties of the human heart. To this end, ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2014.2356792

    authors: Wei H,Viallon M,Delattre BM,Moulin K,Yang F,Croisille P,Zhu Y

    更新日期:2015-01-01 00:00:00

  • Block-iterative Fisher scoring algorithms for maximum penalized likelihood image reconstruction in emission tomography.

    abstract::This paper introduces and evaluates a block-iterative Fisher scoring (BFS) algorithm. The algorithm provides regularized estimation in tomographic models of projection data with Poisson variability. Regularization is achieved by penalized likelihood with a general quadratic penalty. Local convergence of the block-iter...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2008.918355

    authors: Ma J,Hudson M

    更新日期:2008-08-01 00:00:00

  • Evaluation of Fisher Information Matrix-Based Methods for Fast Assessment of Image Quality in Pinhole SPECT.

    abstract::The accurate determination of the local impulse response and the covariance in voxels from penalized maximum likelihood reconstructed images requires performing reconstructions from many noise realizations of the projection data. As this is usually a very time-consuming process, efficient analytical approximations bas...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2015.2410342

    authors: Pato LR,Vandenberghe S,Vandeghinste B,Van Holen R

    更新日期:2015-09-01 00:00:00

  • Strain Energy Decay Predicts Elastic Registration Accuracy from Intraoperative Data Constraints.

    abstract::Image-guided intervention for soft tissue organs depends on the accuracy of deformable registration methods to achieve effective results. While registration techniques based on elastic theory are prevalent, no methods yet exist that can prospectively estimate registration uncertainty to regulate sources and mitigate c...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2021.3052523

    authors: Heiselman JS,Miga MI

    更新日期:2021-01-18 00:00:00

  • Online Combination of EPID & Cherenkov Imaging for 3-D Dosimetry in a Liquid Phantom.

    abstract::Online acquisition of Cherenkov and portal imaging data was combined with a reconstruction scheme called EC3-D, providing a full 3-D dosimetry of megavoltage X-ray beams in a water tank. The methodology was demonstrated and quantified in a single static beam. Furthermore, the dynamics and visualization of the 3-D dose...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2017.2717800

    authors: Bruza P,Andreozzi JM,Gladstone DJ,Jarvis LA,Rottmann J,Pogue BW

    更新日期:2017-10-01 00:00:00

  • Optimization of MRI Gradient Coils With Explicit Peripheral Nerve Stimulation Constraints.

    abstract::Peripheral Nerve Stimulation (PNS) limits the acquisition rate of Magnetic Resonance Imaging data for fast sequences employing powerful gradient systems. The PNS characteristics are currently assessed after the coil design phase in experimental stimulation studies using constructed coil prototypes. This makes it diffi...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2020.3023329

    authors: Davids M,Guerin B,Klein V,Wald LL

    更新日期:2021-01-01 00:00:00

  • Corrections to "Direct Patlak Reconstruction From Dynamic PET Data Using the Kernel Method With MRI Information Based on Structural Similarity".

    abstract::In the above paper [1], there are typos in Algorithm 1 table. The correct version of Algorithm 1 is given below. ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章,已发布勘误

    doi:10.1109/TMI.2018.2849798

    authors: Gong K,Cheng-Liao J,Wang G,Chen KT,Catana C,Qi J

    更新日期:2018-08-01 00:00:00

  • PET image reconstruction using information theoretic anatomical priors.

    abstract::We describe a nonparametric framework for incorporating information from co-registered anatomical images into positron emission tomographic (PET) image reconstruction through priors based on information theoretic similarity measures. We compare and evaluate the use of mutual information (MI) and joint entropy (JE) bet...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2010.2076827

    authors: Somayajula S,Panagiotou C,Rangarajan A,Li Q,Arridge SR,Leahy RM

    更新日期:2011-03-01 00:00:00

  • Voxel-guided morphometry ("VGM") and application to stroke.

    abstract::Monitoring of cerebral diseases associated with a change of morphology (e.g., stroke) requires unprecedented accuracy for quantification of its morphological progression for each voxel. The purpose of this paper is to provide a technique [voxel-guided morphometry (VGM)] to quantify macroscopic anatomical differences. ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2002.806571

    authors: Schormann T,Kraemer M

    更新日期:2003-01-01 00:00:00

  • Head Motion Correction Based on Filtered Backprojection in Helical CT Scanning.

    abstract::Head motion may unexpectedly occur during a CT scan. It thereby results in motion artifacts in a reconstructed image and may lead to a false diagnosis or a failure of diagnosis. To alleviate this motion problem, as a hardware approach, increasing the gantry rotation speed or using an immobilization device is usually c...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2019.2953974

    authors: Jang S,Kim S,Kim M,Son K,Lee KY,Ra JB

    更新日期:2020-05-01 00:00:00

  • Analysis of noise properties of a class of exact methods of inverting the 2-D exponential radon transform [SPECT application].

    abstract::A general approach that the authors proposed elsewhere reveals the intrinsic relationship among methods for inversion of the 2-D exponential Radon transform described by Bellini et al. (1979), by Tretiak and Metz (1980), by Hawkins et al. (1988), and by Inouye et al. (1989). Moreover, the authors' approach provides an...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.476107

    authors: Pan X,Metz CE

    更新日期:1995-01-01 00:00:00

  • Vessel surface reconstruction with a tubular deformable model.

    abstract::Three-dimensional (3-D) angiographic methods are gaining acceptance for evaluation of atherosclerotic disease. However, measurement of vessel stenosis from 3-D angiographic methods can be problematic due to limited image resolution and contrast. We present a method for reconstructing vessel surfaces from 3-D angiograp...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.974935

    authors: Yim PJ,Cebral JJ,Mullick R,Marcos HB,Choyke PL

    更新日期:2001-12-01 00:00:00

  • Pinhole SPECT imaging: compact projection/backprojection operator for efficient algebraic reconstruction.

    abstract::We describe the efficient algebraic reconstruction (EAR) method, which applies to cone-beam tomographic reconstruction problems with a circular symmetry. Three independant steps/stages are presented, which use two symmetries and a factorization of the point spread functions (PSFs), each reducing computing times and ev...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2005.861707

    authors: Israel-Jost V,Choquet P,Salmon S,Blondet C,Sonnendrücker E,Constantinesco A

    更新日期:2006-02-01 00:00:00

  • Robust Unmixing of Dynamic Sequences Using Regions of Interest.

    abstract::In dynamic planar imaging, extraction of signals specific to structures is complicated by structures superposition. Due to overlapping, signals extraction with classic regions of interest (ROIs) methods suffers from inaccuracy, as extracted signals are a mixture of targeted signals. Partial volume effect raises the sa...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2017.2759661

    authors: Filippi M,Desvignes M,Moisan E

    更新日期:2018-01-01 00:00:00

  • 3-D Contrast Source Inversion-Electrical Properties Tomography.

    abstract::Contrast source inversion-electrical properties tomography (CSI-EPT) is an iterative reconstruction method to retrieve the electrical properties (EPs) of tissues from magnetic resonance data. The method is based on integral representations of the electromagnetic field and has been shown to allow EP reconstructions of ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2018.2816125

    authors: Leijsen RL,Brink WM,van den Berg CAT,Webb AG,Remis RF

    更新日期:2018-09-01 00:00:00

  • Discriminative segmentation-based evaluation through shape dissimilarity.

    abstract::Segmentation-based scores play an important role in the evaluation of computational tools in medical image analysis. These scores evaluate the quality of various tasks, such as image registration and segmentation, by measuring the similarity between two binary label maps. Commonly these measurements blend two aspects ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2012.2216281

    authors: Konukoglu E,Glocker B,Ye DH,Criminisi A,Pohl KM

    更新日期:2012-12-01 00:00:00

  • Simultaneous MR-compatible emission and transmission imaging for PET using time-of-flight information.

    abstract::Quantitative positron emission tomography (PET) imaging relies on accurate attenuation correction. Predicting attenuation values from magnetic resonance (MR) images is difficult because MR signals are related to proton density and relaxation properties of tissues. Here, we propose a method to derive the attenuation ma...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2012.2198831

    authors: Mollet P,Keereman V,Clementel E,Vandenberghe S

    更新日期:2012-09-01 00:00:00

  • Probabilistic sparse matching for robust 3D/3D fusion in minimally invasive surgery.

    abstract::Classical surgery is being overtaken by minimally invasive and transcatheter procedures. As there is no direct view or access to the affected anatomy, advanced imaging techniques such as 3D C-arm computed tomography (CT) and C-arm fluoroscopy are routinely used in clinical practice for intraoperative guidance. However...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2014.2343936

    authors: Neumann D,Grbic S,John M,Navab N,Hornegger J,Ionasec R

    更新日期:2015-01-01 00:00:00

  • A filtered backprojection algorithm for triple-source helical cone-beam CT.

    abstract::Multisource cone-beam computed tomography (CT) is an attractive approach of choice for superior temporal resolution, which is critically important for cardiac imaging and contrast enhanced studies. In this paper, we present a filtered-backprojection (FBP) algorithm for triple-source helical cone-beam CT. The algorithm...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2008.2004817

    authors: Zhao J,Jin Y,Lu Y,Wang G

    更新日期:2009-03-01 00:00:00

  • Robust simultaneous detection of coronary borders in complex images.

    abstract::Visual estimation of coronary obstruction severity from angiograms suffers from poor inter- and intraobserver reproducibility and is often inaccurate. In spite of the widely recognized limitations of visual analysis, automated methods have not found widespread clinical use, in part because they too frequently fail to ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.370412

    authors: Sonka M,Winniford MD,Collins SM

    更新日期:1995-01-01 00:00:00

  • Image Registration Based on Low Rank Matrix: Rank-Regularized SSD.

    abstract::Similarity measure is a main core of image registration algorithms. Spatially varying intensity distortion is an important challenge, which affects the performance of similarity measures. Correlation among the pixels is the main characteristic of this distortion. Similarity measures such as sum-of-squared-differences ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2017.2744663

    authors: Ghaffari A,Fatemizadeh E

    更新日期:2018-01-01 00:00:00

  • An optimization transfer algorithm for nonlinear parametric image reconstruction from dynamic PET data.

    abstract::Direct reconstruction of kinetic parameters from raw projection data is a challenging task in molecular imaging using dynamic positron emission tomography (PET). This paper presents a new optimization transfer algorithm for penalized likelihood direct reconstruction of nonlinear parametric images that is easy to use a...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2012.2212203

    authors: Wang G,Qi J

    更新日期:2012-10-01 00:00:00

  • A Krasnoselskii-Mann Algorithm With an Improved EM Preconditioner for PET Image Reconstruction.

    abstract::This paper presents a preconditioned Krasnoselskii-Mann (KM) algorithm with an improved EM preconditioner (IEM-PKMA) for higher-order total variation (HOTV) regularized positron emission tomography (PET) image reconstruction. The PET reconstruction problem can be formulated as a three-term convex optimization model co...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2019.2898271

    authors: Lin Y,Schmidtlein CR,Li Q,Li S,Xu Y

    更新日期:2019-09-01 00:00:00

  • The elliptical cone of uncertainty and its normalized measures in diffusion tensor imaging.

    abstract::Diffusion tensor magnetic resonance imaging (DT-MRI) is capable of providing quantitative insights into tissue microstructure in the brain. An important piece of information offered by DT-MRI is the directional preference of diffusing water molecules within a voxel. Building upon this local directional information, DT...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2008.915663

    authors: Koay CG,Nevo U,Chang LC,Pierpaoli C,Basser PJ

    更新日期:2008-06-01 00:00:00

  • CA-Net: Comprehensive Attention Convolutional Neural Networks for Explainable Medical Image Segmentation.

    abstract::Accurate medical image segmentation is essential for diagnosis and treatment planning of diseases. Convolutional Neural Networks (CNNs) have achieved state-of-the-art performance for automatic medical image segmentation. However, they are still challenged by complicated conditions where the segmentation target has lar...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2020.3035253

    authors: Gu R,Wang G,Song T,Huang R,Aertsen M,Deprest J,Ourselin S,Vercauteren T,Zhang S

    更新日期:2020-11-02 00:00:00

  • Endoscopic video manifolds for targeted optical biopsy.

    abstract::Gastro-intestinal (GI) endoscopy is a widely used clinical procedure for screening and surveillance of digestive tract diseases ranging from Barrett's Oesophagus to oesophageal cancer. Current surveillance protocol consists of periodic endoscopic examinations performed in 3-4 month intervals including expert's visual ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2011.2174252

    authors: Atasoy S,Mateus D,Meining A,Yang GZ,Navab N

    更新日期:2012-03-01 00:00:00

  • Displacement estimation with co-registered ultrasound for image guided neurosurgery: a quantitative in vivo porcine study.

    abstract::Brain shift during open cranial surgery presents a challenge for maintaining registration with image-guidance systems. Ultrasound (US) is a convenient intraoperative imaging modality that may be a useful tool in detecting tissue shift and updating preoperative images based on intraoperative measurements of brain defor...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2003.819293

    authors: Lunn KE,Paulsen KD,Roberts DW,Kennedy FE,Hartov A,West JD

    更新日期:2003-11-01 00:00:00