A Krasnoselskii-Mann Algorithm With an Improved EM Preconditioner for PET Image Reconstruction.

Abstract:

:This paper presents a preconditioned Krasnoselskii-Mann (KM) algorithm with an improved EM preconditioner (IEM-PKMA) for higher-order total variation (HOTV) regularized positron emission tomography (PET) image reconstruction. The PET reconstruction problem can be formulated as a three-term convex optimization model consisting of the Kullback-Leibler (KL) fidelity term, a nonsmooth penalty term, and a nonnegative constraint term which is also nonsmooth. We develop an efficient KM algorithm for solving this optimization problem based on a fixed-point characterization of its solution, with a preconditioner and a momentum technique for accelerating convergence. By combining the EM precondtioner, a thresholding, and a good inexpensive estimate of the solution, we propose an improved EM preconditioner that can not only accelerate convergence but also avoid the reconstructed image being "stuck at zero." Numerical results in this paper show that the proposed IEM-PKMA outperforms existing state-of-the-art algorithms including, the optimization transfer descent algorithm and the preconditioned L-BFGS-B algorithm for the differentiable smoothed anisotropic total variation regularized model, the preconditioned alternating projection algorithm, and the alternating direction method of multipliers for the nondifferentiable HOTV regularized model. Encouraging initial experiments using clinical data are presented.

journal_name

IEEE Trans Med Imaging

authors

Lin Y,Schmidtlein CR,Li Q,Li S,Xu Y

doi

10.1109/TMI.2019.2898271

subject

Has Abstract

pub_date

2019-09-01 00:00:00

pages

2114-2126

issue

9

eissn

0278-0062

issn

1558-254X

journal_volume

38

pub_type

杂志文章
  • Image-Based Investigation of Human in Vivo Myofibre Strain.

    abstract::Cardiac myofibre deformation is an important determinant of the mechanical function of the heart. Quantification of myofibre strain relies on 3D measurements of ventricular wall motion interpreted with respect to the tissue microstructure. In this study, we estimated in vivo myofibre strain using 3D structural and fun...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2016.2580573

    authors: Wang VY,Casta C,Zhu YM,Cowan BR,Croisille P,Young AA,Clarysse P,Nash MP

    更新日期:2016-11-01 00:00:00

  • Authors' reply.

    abstract::The comment of Stig Steenstrup on the use of gray level entropy function in our paper' has been addressed. The entropy measure has not been used in the procedure of enhancement, but it has only been used to show statistically that the enhanced images have larger gray level entropy, and therefore better utilize the gra...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.1987.4307802

    authors: Dhawan AP,Gordon R

    更新日期:1987-01-01 00:00:00

  • Patlak image estimation from dual time-point list-mode PET data.

    abstract::We investigate using dual time-point PET data to perform Patlak modeling. This approach can be used for whole body dynamic PET studies in which we compute voxel-wise estimates of Patlak parameters using two frames of data for each bed position. Our approach directly uses list-mode arrival times for each event to estim...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2014.2298868

    authors: Zhu W,Li Q,Bai B,Conti PS,Leahy RM

    更新日期:2014-04-01 00:00:00

  • Compensation for nonuniform resolution using penalized-likelihood reconstruction in space-variant imaging systems.

    abstract::Imaging systems that form estimates using a statistical approach generally yield images with nonuniform resolution properties. That is, the reconstructed images possess resolution properties marked by space-variant and/or anisotropic responses. We have previously developed a space-variant penalty for penalized-likelih...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2003.823063

    authors: Stayman JW,Fessler JA

    更新日期:2004-03-01 00:00:00

  • Determination of optimal angiographic viewing angles: basic principles and evaluation study.

    abstract::Foreshortening of vessel segments in angiographic (biplane) projection images may cause misinterpretation of the extent and degree of coronary artery disease. The views in which the object of interest are visualized with minimum foreshortening are called optimal views. The authors present a complete approach to obtain...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.276141

    authors: Dumay AM,Reiber JC,Gerbrands JJ

    更新日期:1994-01-01 00:00:00

  • A backprojection filtering algorithm for a spatially varying focal length collimator.

    abstract::Fan-beam collimators are used in single photon emission computed tomography to improve the sensitivity for imaging of small organs. The disadvantage of fan-beam collimation is the truncation of projection data surrounding the organ of interest or, in those cases of imaging large patients, of the organ itself producing...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.310886

    authors: Zeng GL,Gullberg GT

    更新日期:1994-01-01 00:00:00

  • Estimating 3-D respiratory motion from orbiting views by tomographic image registration.

    abstract::Respiratory motion remains a significant source of errors in treatment planning for the thorax and upper abdomen. Recently, we proposed a method to estimate two-dimensional (2-D) object motion from a sequence of slowly rotating X-ray projection views, which we called deformation from orbiting views (DOVs). In this met...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2006.889719

    authors: Zeng R,Fessler JA,Balter JM

    更新日期:2007-02-01 00:00:00

  • Characterization of visually similar diffuse diseases from B-scan liver images using nonseparable wavelet transform.

    abstract::This paper describes a new approach for texture characterization, based on nonseparable wavelet decomposition, and its application for the discrimination of visually similar diffuse diseases of liver. The proposed feature-extraction algorithm applies nonseparable quincunx wavelet transform and uses energies of the tra...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.730399

    authors: Mojsilović A,Popović M,Marković S,Krstić M

    更新日期:1998-08-01 00:00:00

  • Multi-TI Arterial Spin Labeling MRI with Variable TR and Bolus Duration for Cerebral Blood Flow and Arterial Transit Time Mapping.

    abstract::Arterial spin labeling (ASL) is an MRI perfusion imaging method from which quantitative cerebral blood flow (CBF) can be calculated. We present a multi-TI ASL method (multi-TI integrated ASL) in which variable post-labeling delays and variable TRs are used to improve the estimation of arterial transit time (ATT) and C...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2015.2395257

    authors: Johnston ME,Lu K,Maldjian JA,Jung Y

    更新日期:2015-06-01 00:00:00

  • In vivo impedance imaging with total variation regularization.

    abstract::We show that electrical impedance tomography (EIT) image reconstruction algorithms with regularization based on the total variation (TV) functional are suitable for in vivo imaging of physiological data. This reconstruction approach helps to preserve discontinuities in reconstructed profiles, such as step changes in e...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2009.2022540

    authors: Borsic A,Graham BM,Adler A,Lionheart WR

    更新日期:2010-01-01 00:00:00

  • Lung segmentation in chest radiographs using anatomical atlases with nonrigid registration.

    abstract::The National Library of Medicine (NLM) is developing a digital chest X-ray (CXR) screening system for deployment in resource constrained communities and developing countries worldwide with a focus on early detection of tuberculosis. A critical component in the computer-aided diagnosis of digital CXRs is the automatic ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2013.2290491

    authors: Candemir S,Jaeger S,Palaniappan K,Musco JP,Singh RK,Zhiyun Xue,Karargyris A,Antani S,Thoma G,McDonald CJ

    更新日期:2014-02-01 00:00:00

  • Globally convergent image reconstruction for emission tomography using relaxed ordered subsets algorithms.

    abstract::We present two types of globally convergent relaxed ordered subsets (OS) algorithms for penalized-likelihood image reconstruction in emission tomography: modified block sequential regularized expectation-maximization (BSREM) and relaxed OS separable paraboloidal surrogates (OS-SPS). The global convergence proof of the...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2003.812251

    authors: Ahn S,Fessler JA

    更新日期:2003-05-01 00:00:00

  • SNORE: spike noise removal and detection.

    abstract::A method for detection and removal of random spike noise in magnetic resonance (MR) raw data (k-space data) is described. This method would reduce or eliminate the corduroy-type and higher than usual level artifacts in MR images resulting from random spike noise in k-space data. The method described involves applying ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.276151

    authors: Foo TF,Grigsby NS,Mitchell JD,Slayman BE

    更新日期:1994-01-01 00:00:00

  • Compressed Sensing Reconstruction of 3D Ultrasound Data Using Dictionary Learning and Line-Wise Subsampling.

    abstract::In this paper we present a compressed sensing (CS) method adapted to 3D ultrasound imaging (US). In contrast to previous work, we propose a new approach based on the use of learned overcomplete dictionaries that allow for much sparser representations of the signals since they are optimized for a particular class of im...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2015.2442154

    authors: Lorintiu O,Liebgott H,Alessandrini M,Bernard O,Friboulet D

    更新日期:2015-12-01 00:00:00

  • Automatic Segmentation of Wrist Bones in CT Using a Statistical Wrist Shape + Pose Model.

    abstract::Segmentation of the wrist bones in CT images has been frequently used in different clinical applications including arthritis evaluation, bone age assessment and image-guided interventions. The major challenges include non-uniformity and spongy textures of the bone tissue as well as narrow inter-bone spaces. In this wo...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2016.2529500

    authors: Anas EM,Rasoulian A,Seitel A,Darras K,Wilson D,John PS,Pichora D,Mousavi P,Rohling R,Abolmaesumi P

    更新日期:2016-08-01 00:00:00

  • Segmentation of rodent whole-body dynamic PET images: an unsupervised method based on voxel dynamics.

    abstract::Positron emission tomography (PET) is a useful tool for pharmacokinetics studies in rodents during the preclinical phase of drug and tracer development. However, rodent organs are small as compared to the scanner's intrinsic resolution and are affected by physiological movements. We present a new method for the segmen...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2007.905106

    authors: Maroy R,Boisgard R,Comtat C,Frouin V,Cathier P,Duchesnay E,Dollé F,Nielsen PE,Trébossen R,Tavitian B

    更新日期:2008-03-01 00:00:00

  • Time-frequency MEG-MUSIC algorithm.

    abstract::We propose a method that incorporates the time-frequency characteristics of neural sources into magnetoencephalographic (MEG) source estimation. The method is based on the multiple-signal-classification (MUSIC) algorithm and it calculates a time--frequency matrix in which diagonal and off-diagonal terms are the auto a...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.750262

    authors: Sekihara K,Nagarajan S,Poeppel D,Miyashita Y

    更新日期:1999-01-01 00:00:00

  • Neuro-fuzzy systems for computer-aided myocardial viability assessment.

    abstract::This paper describes a multimodality framework for computer-aided myocardial viability assessment based on neuro-fuzzy techniques. The proposed approach distinguishes two main levels: the modality-independent inference level and the modality-dependent application level. This two-level distinction releases the hard con...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.974925

    authors: Behloul F,Lelieveldt BP,Boudraa A,Janier MF,Revel D,Reiber JH

    更新日期:2001-12-01 00:00:00

  • Segmentation of the optic disc, macula and vascular arch in fundus photographs.

    abstract::An automatic system is presented to find the location of the major anatomical structures in color fundus photographs; the optic disc, the macula, and the vascular arch. These structures are found by fitting a single point-distribution-model to the image, that contains points on each structure. The method can handle op...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2006.885336

    authors: Niemeijer M,Abràmoff MD,van Ginneken B

    更新日期:2007-01-01 00:00:00

  • Compressed Sensing Doppler Ultrasound Reconstruction Using Block Sparse Bayesian Learning.

    abstract::In this paper we propose a framework for using duplex Doppler ultrasound systems. These type of systems need to interleave the acquisition and display of a B-mode image and of the pulsed Doppler spectrogram. In a recent study (Richy , 2013), we have shown that compressed sensing-based reconstruction of Doppler signal ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2015.2504240

    authors: Lorintiu O,Liebgott H,Friboulet D

    更新日期:2016-04-01 00:00:00

  • Deformable registration of glioma images using EM algorithm and diffusion reaction modeling.

    abstract::This paper investigates the problem of atlas registration of brain images with gliomas. Multiparametric imaging modalities (T1, T1-CE, T2, and FLAIR) are first utilized for segmentations of different tissues, and to compute the posterior probability map (PBM) of membership to each tissue class, using supervised learni...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2010.2078833

    authors: Gooya A,Biros G,Davatzikos C

    更新日期:2011-02-01 00:00:00

  • Deep Geodesic Learning for Segmentation and Anatomical Landmarking.

    abstract::In this paper, we propose a novel deep learning framework for anatomy segmentation and automatic landmarking. Specifically, we focus on the challenging problem of mandible segmentation from cone-beam computed tomography (CBCT) scans and identification of 9 anatomical landmarks of the mandible on the geodesic space. Th...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2018.2875814

    authors: Torosdagli N,Liberton DK,Verma P,Sincan M,Lee JS,Bagci U

    更新日期:2019-04-01 00:00:00

  • Toward Electrical Impedance Tomography Coupled Ultrasound Imaging for Assessing Muscle Health.

    abstract::This paper establishes for the first time that a coupled ultrasound (US) and electrical impedance tomography (EIT) system can serve as a non-invasive, spatially localized approach to extract clinically relevant muscle properties. The US/EIT system represents a potential enhancement to electrical impedance myography (E...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2018.2886152

    authors: Murphy EK,Skinner J,Martucci M,Rutkove SB,Halter RJ

    更新日期:2019-06-01 00:00:00

  • An image-guided planning system for endosseous oral implants.

    abstract::A preoperative planning system for oral implant surgery was developed which takes as input computed tomographies (CT's) of the jaws. Two-dimensional (2-D) reslices of these axial CT slices orthogonal to a curve following the jaw arch are computed and shown together with three-dimensional (3-D) surface rendered models ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.736056

    authors: Verstreken K,Van Cleynenbreugel J,Martens K,Marchal G,van Steenberghe D,Suetens P

    更新日期:1998-10-01 00:00:00

  • Robust simultaneous detection of coronary borders in complex images.

    abstract::Visual estimation of coronary obstruction severity from angiograms suffers from poor inter- and intraobserver reproducibility and is often inaccurate. In spite of the widely recognized limitations of visual analysis, automated methods have not found widespread clinical use, in part because they too frequently fail to ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.370412

    authors: Sonka M,Winniford MD,Collins SM

    更新日期:1995-01-01 00:00:00

  • Clustered components analysis for functional MRI.

    abstract::A common method of increasing hemodynamic response (SNR) in functional magnetic resonance imaging (fMRI) is to average signal timecourses across voxels. This technique is potentially problematic because the hemodynamic response may vary across the brain. Such averaging may destroy significant features in the temporal ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2003.819922

    authors: Chen S,Bouman CA,Lowe MJ

    更新日期:2004-01-01 00:00:00

  • A Generalized Correlation-Based Model for Out-of-Plane Motion Estimation in Freehand Ultrasound.

    abstract::A big challenge in sensorless image-based ultrasound tracking is in the out-of-plane motion estimation. The correlation value of a specific model of speckle known as fully developed speckle (FDS) can be used to estimate the out-of-plane displacement. In real tissue, this kind of pattern is rare and the deviation of sp...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2013.2283969

    authors: Afsham N,Najafi M,Abolmaesumi P,Rohling R

    更新日期:2014-01-01 00:00:00

  • Principal Component Analysis Based Dynamic Cone Beam X-Ray Luminescence Computed Tomography: A Feasibility Study.

    abstract::Cone beam X-ray luminescence computed tomography (CB-XLCT) is a promising imaging technique in studying the physiological and pathological processes in small animals. However, the dynamic bio-distributions of probes in small animal, especially in adjacent targets are still hard to be captured directly from dynamic CB-...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2019.2917026

    authors: Pu H,Gao P,Liu Y,Rong J,Shi F,Lu H

    更新日期:2019-12-01 00:00:00

  • A Kernel-Based Low-Rank (KLR) Model for Low-Dimensional Manifold Recovery in Highly Accelerated Dynamic MRI.

    abstract::While many low rank and sparsity-based approaches have been developed for accelerated dynamic magnetic resonance imaging (dMRI), they all use low rankness or sparsity in input space, overlooking the intrinsic nonlinear correlation in most dMRI data. In this paper, we propose a kernel-based framework to allow nonlinear...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2017.2723871

    authors: Nakarmi U,Wang Y,Lyu J,Liang D,Ying L

    更新日期:2017-11-01 00:00:00

  • Imaging of cardiac movement using ratiometric and nonratiometric optical mapping: effects of ischemia and 2, 3-butaneodione monoxime.

    abstract::Transmembrane voltage-sensitive fluorescent dyes are used to study electrical activity in hearts. Green and red fluorescence emissions from di-4-ANEPPS excited with 488 nm light indicate both transmembrane voltage changes and heart movement. We have previously shown that the ratio, green fluorescence divided by red fl...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2005.861019

    authors: Himel HD 4th,Knisley SB

    更新日期:2006-01-01 00:00:00