Compressed Sensing Reconstruction of 3D Ultrasound Data Using Dictionary Learning and Line-Wise Subsampling.

Abstract:

:In this paper we present a compressed sensing (CS) method adapted to 3D ultrasound imaging (US). In contrast to previous work, we propose a new approach based on the use of learned overcomplete dictionaries that allow for much sparser representations of the signals since they are optimized for a particular class of images such as US images. In this study, the dictionary was learned using the K-SVD algorithm and CS reconstruction was performed on the non-log envelope data by removing 20% to 80% of the original data. Using numerically simulated images, we evaluate the influence of the training parameters and of the sampling strategy. The latter is done by comparing the two most common sampling patterns, i.e., point-wise and line-wise random patterns. The results show in particular that line-wise sampling yields an accuracy comparable to the conventional point-wise sampling. This indicates that CS acquisition of 3D data is feasible in a relatively simple setting, and thus offers the perspective of increasing the frame rate by skipping the acquisition of RF lines. Next, we evaluated this approach on US volumes of several ex vivo and in vivo organs. We first show that the learned dictionary approach yields better performances than conventional fixed transforms such as Fourier or discrete cosine. Finally, we investigate the generality of the learned dictionary approach and show that it is possible to build a general dictionary allowing to reliably reconstruct different volumes of different ex vivo or in vivo organs.

journal_name

IEEE Trans Med Imaging

authors

Lorintiu O,Liebgott H,Alessandrini M,Bernard O,Friboulet D

doi

10.1109/TMI.2015.2442154

subject

Has Abstract

pub_date

2015-12-01 00:00:00

pages

2467-77

issue

12

eissn

0278-0062

issn

1558-254X

journal_volume

34

pub_type

杂志文章
  • Automatic "pipeline" analysis of 3-D MRI data for clinical trials: application to multiple sclerosis.

    abstract::The quantitative analysis of magnetic resonance imaging (MRI) data has become increasingly important in both research and clinical studies aiming at human brain development, function, and pathology. Inevitably, the role of quantitative image analysis in the evaluation of drug therapy will increase, driven in part by r...

    journal_title:IEEE transactions on medical imaging

    pub_type: 临床试验,杂志文章

    doi:10.1109/TMI.2002.806283

    authors: Zijdenbos AP,Forghani R,Evans AC

    更新日期:2002-10-01 00:00:00

  • Characteristic quantities of microvascular structures in CLSM volume datasets.

    abstract::A method for fully automated morphological and topological quantification of microvascular structures in confocal laser scanning microscopy (CLSM) volume datasets is presented. Several characteristic morphological and topological quantities are calculated in a series of image-processing steps and can be used to compar...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2007.900379

    authors: Winter K,Metz LH,Kuska JP,Frerich B

    更新日期:2007-08-01 00:00:00

  • A penalized-likelihood image reconstruction method for emission tomography, compared to postsmoothed maximum-likelihood with matched spatial resolution.

    abstract::Regularization is desirable for image reconstruction in emission tomography. A powerful regularization method is the penalized-likelihood (PL) reconstruction algorithm (or equivalently, maximum a posteriori reconstruction), where the sum of the likelihood and a noise suppressing penalty term (or Bayesian prior) is opt...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2003.816960

    authors: Nuyts J,Fessler JA

    更新日期:2003-09-01 00:00:00

  • Adaptive reproducing kernel particle method for extraction of the cortical surface.

    abstract::We propose a novel adaptive approach based on the Reproducing Kernel Particle Method (RKPM) to extract the cortical surfaces of the brain from three-dimensional (3-D) magnetic resonance images (MRIs). To formulate the discrete equations of the deformable model, a flexible particle shape function is employed in the Gal...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/tmi.2006.873614

    authors: Xu M,Thompson PM,Toga AW

    更新日期:2006-06-01 00:00:00

  • Multiscale AM-FM methods for diabetic retinopathy lesion detection.

    abstract::In this paper, we propose the use of multiscale amplitude-modulation-frequency-modulation (AM-FM) methods for discriminating between normal and pathological retinal images. The method presented in this paper is tested using standard images from the early treatment diabetic retinopathy study. We use 120 regions of 40 x...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2009.2037146

    authors: Agurto C,Murray V,Barriga E,Murillo S,Pattichis M,Davis H,Russell S,Abramoff M,Soliz P

    更新日期:2010-02-01 00:00:00

  • Fractal feature analysis and classification in medical imaging.

    abstract::Following B.B. Mandelbrot's fractal theory (1982), it was found that the fractal dimension could be obtained in medical images by the concept of fractional Brownian motion. An estimation concept for determination of the fractal dimension based upon the concept of fractional Brownian motion is discussed. Two applicatio...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.24861

    authors: Chen CC,Daponte JS,Fox MD

    更新日期:1989-01-01 00:00:00

  • Algebraic reconstruction for magnetic resonance imaging under B0 inhomogeneity.

    abstract::In magnetic resonance imaging, spatial localization is usually achieved using Fourier encoding which is realized by applying a magnetic field gradient along the dimension of interest to create a linear correspondence between the resonance frequency and spatial location following the Larmor equation. In the presence of...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.712126

    authors: Kadah YM,Hu X

    更新日期:1998-06-01 00:00:00

  • Deep Learning for Fast and Spatially Constrained Tissue Quantification From Highly Accelerated Data in Magnetic Resonance Fingerprinting.

    abstract::Magnetic resonance fingerprinting (MRF) is a quantitative imaging technique that can simultaneously measure multiple important tissue properties of human body. Although MRF has demonstrated improved scan efficiency as compared to conventional techniques, further acceleration is still desired for translation into routi...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2019.2899328

    authors: Fang Z,Chen Y,Liu M,Xiang L,Zhang Q,Wang Q,Lin W,Shen D

    更新日期:2019-10-01 00:00:00

  • Measures of acutance and shape for classification of breast tumors.

    abstract::Most benign breast tumors possess well-defined, sharp boundaries that delineate them from surrounding tissues, as opposed to malignant tumors. Computer techniques proposed to date for tumor analysis have concentrated on shape factors of tumor regions and texture measures. While shape measures based on contours of tumo...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.650876

    authors: Rangayyan RM,El-Faramawy NM,Desautels JE,Alim OA

    更新日期:1997-12-01 00:00:00

  • The adaptive bases algorithm for intensity-based nonrigid image registration.

    abstract::Nonrigid registration of medical images is important for a number of applications such as the creation of population averages, atlas-based segmentation, or geometric correction of functional magnetic resonance imaging (fMRI) images to name a few. In recent years, a number of methods have been proposed to solve this pr...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2003.819299

    authors: Rohde GK,Aldroubi A,Dawant BM

    更新日期:2003-11-01 00:00:00

  • Edge displacement field-based classification for improved detection of polyps in CT colonography.

    abstract::Colorectal cancer can easily be prevented provided that the precursors to tumors, small colonic polyps, are detected and removed. Currently, the only definitive examination of the colon is fiber-optic colonoscopy, which is invasive and expensive. Computed tomographic colonography (CTC) is potentially a less costly and...

    journal_title:IEEE transactions on medical imaging

    pub_type: 临床试验,杂志文章

    doi:10.1109/TMI.2002.806405

    authors: Acar B,Beaulieu CF,Göktürk SB,Tomasi C,Paik DS,Jeffrey RB Jr,Yee J,Napel S

    更新日期:2002-12-01 00:00:00

  • Motion-compensated and gated cone beam filtered back-projection for 3-D rotational X-ray angiography.

    abstract::This paper presents a method to reconstruct moving objects from cone beam X-ray projections acquired during a single rotational run using a given motion vector field. The method is applicable to voxel driven cone-beam filtered back-projection reconstruction approaches. Here, a formulation based on the algorithm of Fel...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/tmi.2006.876147

    authors: Schäfer D,Borgert J,Rasche V,Grass M

    更新日期:2006-07-01 00:00:00

  • A fast Bayesian reconstruction algorithm for emission tomography with entropy prior converging to feasible images.

    abstract::The development and tests of an iterative reconstruction algorithm for emission tomography based on Bayesian statistical concepts are described. The algorithm uses the entropy of the generated image as a prior distribution, can be accelerated by the choice of an exponent, and converges uniformly to feasible images by ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.56340

    authors: Nunez J,Llacer J

    更新日期:1990-01-01 00:00:00

  • Accelerating the nonequispaced fast Fourier transform on commodity graphics hardware.

    abstract::We present a fast parallel algorithm to compute the nonequispaced fast Fourier transform on commodity graphics hardware (the GPU). We focus particularly on a novel implementation of the convolution step in the transform as it was previously its most time consuming part. We describe the performance for two common sampl...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2007.909834

    authors: Sorensen TS,Schaeffter T,Noe KO,Hansen MS

    更新日期:2008-04-01 00:00:00

  • Classification of malignant and benign masses based on hybrid ART2LDA approach.

    abstract::A new type of classifier combining an unsupervised and a supervised model was designed and applied to classification of malignant and benign masses on mammograms. The unsupervised model was based on an adaptive resonance theory (ART2) network which clustered the masses into a number of separate classes. The classes we...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.819327

    authors: Hadjiiski L,Sahiner B,Chan HP,Petrick N,Helvie M

    更新日期:1999-12-01 00:00:00

  • A registration framework for the comparison of mammogram sequences.

    abstract::In this paper, we present a two-stage algorithm for mammogram registration, the geometrical alignment of mammogram sequences. The rationale behind this paper stems from the intrinsic difficulties in comparing mammogram sequences. Mammogram comparison is a valuable tool in national breast screening programs as well as ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 临床试验,杂志文章

    doi:10.1109/TMI.2005.848374

    authors: Marias K,Behrenbruch C,Parbhoo S,Seifalian A,Brady M

    更新日期:2005-06-01 00:00:00

  • Free-breathing diffusion tensor imaging and tractography of the human heart in healthy volunteers using wavelet-based image fusion.

    abstract::Free-breathing cardiac diffusion tensor imaging (DTI) is a promising but challenging technique for the study of fiber structures of the human heart in vivo. This work proposes a clinically compatible and robust technique to provide three-dimensional (3-D) fiber architecture properties of the human heart. To this end, ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2014.2356792

    authors: Wei H,Viallon M,Delattre BM,Moulin K,Yang F,Croisille P,Zhu Y

    更新日期:2015-01-01 00:00:00

  • Accelerated Parameter Mapping of Multiple-Echo Gradient-Echo Data Using Model-Based Iterative Reconstruction.

    abstract::A new reconstruction method, coined MIRAGE, is presented for accurate, fast, and robust parameter mapping of multiple-echo gradient-echo (MEGE) imaging, the basis sequence of novel quantitative magnetic resonance imaging techniques such as water content and susceptibility mapping. Assuming that the temporal signal can...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2017.2771504

    authors: Zimmermann M,Abbas Z,Dzieciol K,Shah NJ

    更新日期:2018-02-01 00:00:00

  • A Signal Acquisition Setup for Ultrashort Echo Time Imaging Operating in Parallel on Unmodified Clinical MRI Scanners Achieving an Acquisition Delay of [Formula: see text].

    abstract::Ultrashort echo time imaging on clinical systems is still limited by the rather long radio frequency switching times achievable with standard front end concepts. In this contribution, an independent parallel receive-only system is interfaced to an unmodified clinical MRI system, enabling imaging of species with ultras...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2019.2924057

    authors: Eder M,Horneff A,Paul J,Storm A,Wunderlich A,Hell E,Ulrici J,Anders J,Rasche V

    更新日期:2020-01-01 00:00:00

  • A row-action alternative to the EM algorithm for maximizing likelihood in emission tomography.

    abstract::The maximum likelihood (ML) approach to estimating the radioactive distribution in the body cross section has become very popular among researchers in emission computed tomography (ECT) since it has been shown to provide very good images compared to those produced with the conventional filtered backprojection (FBP) al...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.538946

    authors: Browne J,de Pierro AB

    更新日期:1996-01-01 00:00:00

  • An Enhanced SMART-RECON Algorithm for Time-Resolved C-Arm Cone-Beam CT Imaging.

    abstract::Temporal resolution in time-resolved cone-beam CT (TR-CBCT) imaging is often limited by the time needed to acquire a complete data set for image reconstruction. With the recent developments of performing nearly limited-view artifact-free reconstruction from data in a limited-view angle range and a prior image, tempora...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2019.2960720

    authors: Li Y,Garrett JW,Li K,Strother C,Chen GH

    更新日期:2020-06-01 00:00:00

  • Exact radon rebinning algorithm for the long object problem in helical cone-beam CT.

    abstract::This paper addresses the long object problem in helical cone-beam computed tomography. We present the PHI-method, a new algorithm for the exact reconstruction of a region-of-interest (ROI) of a long object from axially truncated data extending only slightly beyond the ROI. The PHI-method is an extension of the Radon-m...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.870247

    authors: Schaller S,Sauer F,Tam KC,Lauritsch G,Flohr T

    更新日期:2000-05-01 00:00:00

  • Ultrafast Ultrasound Imaging With Cascaded Dual-Polarity Waves.

    abstract::Ultrafast ultrasound imaging using plane or diverging waves, instead of focused beams, has advanced greatly the development of novel ultrasound imaging methods for evaluating tissue functions beyond anatomical information. However, the sonographic signal-to-noise ratio (SNR) of ultrafast imaging remains limited due to...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2017.2781261

    authors: Zhang Y,Guo Y,Lee WN

    更新日期:2018-04-01 00:00:00

  • Sparse reconstruction of the magnetic particle imaging system matrix.

    abstract::Magnetic particle imaging allows to determine the spatial distribution of magnetic nanoparticles in vivo. The system matrix in magnetic particle imaging is commonly acquired in a tedious calibration scan and requires to measure the system response at numerous positions in the field-of-view. In this paper, we propose a...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2013.2258029

    authors: Knopp T,Weber A

    更新日期:2013-08-01 00:00:00

  • Stratified Decision Forests for Accurate Anatomical Landmark Localization in Cardiac Images.

    abstract::Accurate localization of anatomical landmarks is an important step in medical imaging, as it provides useful prior information for subsequent image analysis and acquisition methods. It is particularly useful for initialization of automatic image analysis tools (e.g. segmentation and registration) and detection of scan...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2016.2597270

    authors: Oktay O,Bai W,Guerrero R,Rajchl M,de Marvao A,O'Regan DP,Cook SA,Heinrich MP,Glocker B,Rueckert D

    更新日期:2017-01-01 00:00:00

  • A system for real-time XMR guided cardiovascular intervention.

    abstract::The hybrid magnetic resonance (MR)/X-ray suite (XMR) is a recently introduced imaging solution that provides new possibilities for guidance of cardiovascular catheterization procedures. We have previously described and validated a technique based on optical tracking to register MR and X-ray images obtained from the sl...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2005.856731

    authors: Rhode KS,Sermesant M,Brogan D,Hegde S,Hipwell J,Lambiase P,Rosenthal E,Bucknall C,Qureshi SA,Gill JS,Razavi R,Hill DL

    更新日期:2005-11-01 00:00:00

  • Improved Sensitivity in Ultrasound Molecular Imaging With Coherence-Based Beamforming.

    abstract::Ultrasound molecular imaging (USMI) is accomplished by detecting microbubble (MB) contrast agents that have bound to specific biomarkers, and can be used for a variety of imaging applications, such as the early detection of cancer. USMI has been widely utilized in preclinical imaging in mice; however, USMI in humans c...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2017.2774814

    authors: Hyun D,Abou-Elkacem L,Perez VA,Chowdhury SM,Willmann JK,Dahl JJ

    更新日期:2018-01-01 00:00:00

  • Tracking pylorus in ultrasonic image sequences with edge-based optical flow.

    abstract::Tracking pylorus in ultrasonic image sequences is an important step in the analysis of duodenogastric reflux (DGR). We propose a joint prediction and segmentation method (JPS) which combines optical flow with active contour to track pylorus. The goal of the proposed method is to improve the pyloric tracking accuracy b...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2012.2183884

    authors: Chen C,Wang Y,Yu J,Zhou Z,Shen L,Chen Y

    更新日期:2012-03-01 00:00:00

  • Spatial transformation of DWI data using non-negative sparse representation.

    abstract::This paper presents an algorithm to transform and reconstruct diffusion-weighted imaging (DWI) data for alignment of micro-structures in association with spatial transformations. The key idea is to decompose the diffusion signal profile, a function defined on a unit sphere, into a series of weighted diffusion basis fu...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2012.2204766

    authors: Yap PT,Shen D

    更新日期:2012-11-01 00:00:00

  • Classification of disease subgroup and correlation with disease severity using magnetic resonance imaging whole-brain histograms: application to magnetization transfer ratios and multiple sclerosis.

    abstract::This paper presents a new approach to characterize subtle diffuse changes in multiple sclerosis (MS) using histograms derived from magnetization transfer ratio (MTR) images. Two major parts dominate our histogram analysis; 1) Classification of MTR histograms into control and MS subgroups; 2) Correlation with current d...

    journal_title:IEEE transactions on medical imaging

    pub_type: 临床试验,杂志文章

    doi:10.1109/TMI.2002.1000256

    authors: Dehmeshki J,Barker GJ,Tofts PS

    更新日期:2002-04-01 00:00:00