Automatic Segmentation of Wrist Bones in CT Using a Statistical Wrist Shape + Pose Model.

Abstract:

:Segmentation of the wrist bones in CT images has been frequently used in different clinical applications including arthritis evaluation, bone age assessment and image-guided interventions. The major challenges include non-uniformity and spongy textures of the bone tissue as well as narrow inter-bone spaces. In this work, we propose an automatic wrist bone segmentation technique for CT images based on a statistical model that captures the shape and pose variations of the wrist joint across 60 example wrists at nine different wrist positions. To establish the correspondences across the training shapes at neutral positions, the wrist bone surfaces are jointly aligned using a group-wise registration framework based on a Gaussian Mixture Model. Principal component analysis is then used to determine the major modes of shape variations. The variations in poses not only across the population but also across different wrist positions are incorporated in two pose models. An intra-subject pose model is developed by utilizing the similarity transforms at all wrist positions across the population. Further, an inter-subject pose model is used to model the pose variations across different wrist positions. For segmentation of the wrist bones in CT images, the developed model is registered to the edge point cloud extracted from the CT volume through an expectation maximization based probabilistic approach. Residual registration errors are corrected by application of a non-rigid registration technique. We validate the proposed segmentation method by registering the wrist model to a total of 66 unseen CT volumes of average voxel size of 0.38 mm. We report a mean surface distance error of 0.33 mm and a mean Jaccard index of 0.86.

journal_name

IEEE Trans Med Imaging

authors

Anas EM,Rasoulian A,Seitel A,Darras K,Wilson D,John PS,Pichora D,Mousavi P,Rohling R,Abolmaesumi P

doi

10.1109/TMI.2016.2529500

subject

Has Abstract

pub_date

2016-08-01 00:00:00

pages

1789-801

issue

8

eissn

0278-0062

issn

1558-254X

journal_volume

35

pub_type

杂志文章
  • MRI pulse sequence design with first-order gradient moment nulling in arbitrary directions by solving a polynomial program.

    abstract::We suggest a polynomial program for the calculation of optimized gradient waveforms for magnetic resonance tomography pulse sequences. Such non-linear mathematical programs can describe gradient system capabilities, meet k-space trajectory specifications, and capture sequence timing conditions. Moreover they allow the...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2010.2042723

    authors: Majewski K,Heid O,Kluge T

    更新日期:2010-06-01 00:00:00

  • SVD compression for magnetic resonance fingerprinting in the time domain.

    abstract::Magnetic resonance (MR) fingerprinting is a technique for acquiring and processing MR data that simultaneously provides quantitative maps of different tissue parameters through a pattern recognition algorithm. A predefined dictionary models the possible signal evolutions simulated using the Bloch equations with differ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2014.2337321

    authors: McGivney DF,Pierre E,Ma D,Jiang Y,Saybasili H,Gulani V,Griswold MA

    更新日期:2014-12-01 00:00:00

  • MDM-PCCT: Multiple Dynamic Modulations for High-Performance Spectral PCCT Imaging.

    abstract::Photon counting computed tomography (PCCT) has the ability to identify individual photons, resulting in quantitative material identification. Meanwhile, several technical challenges still exist in current PCCT imaging systems, including increased noise and suboptimal bin selection. These nonideal effects can substanti...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2020.3001616

    authors: Li D,Zeng D,Li S,Ge Y,Bian Z,Huang J,Ma J

    更新日期:2020-11-01 00:00:00

  • Magnetic Particle Imaging: A Resovist Based Marking Technology for Guide Wires and Catheters for Vascular Interventions.

    abstract::Magnetic particle imaging (MPI) is able to provide high temporal and good spatial resolution, high signal to noise ratio and sensitivity. Furthermore, it is a truly quantitative method as its signal strength is proportional to the concentration of its tracer, superparamagnetic iron oxide nanoparticles (SPIOs), over a ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2016.2559538

    authors: Haegele J,Panagiotopoulos N,Cremers S,Rahmer J,Franke J,Duschka RL,Vaalma S,Heidenreich M,Borgert J,Borm P,Barkhausen J,Vogt FM

    更新日期:2016-10-01 00:00:00

  • A nonparametric method for automatic correction of intensity nonuniformity in MRI data.

    abstract::A novel approach to correcting for intensity nonuniformity in magnetic resonance (MR) data is described that achieves high performance without requiring a model of the tissue classes present. The method has the advantage that it can be applied at an early stage in an automated data analysis, before a tissue model is a...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.668698

    authors: Sled JG,Zijdenbos AP,Evans AC

    更新日期:1998-02-01 00:00:00

  • In Vivo Measurement of Brain Tissue Response After Irradiation: Comparison of T2 Relaxation, Apparent Diffusion Coefficient, and Electrical Conductivity.

    abstract::Radiation therapy (RT) has been widely used as a powerful treatment tool to address cancerous tissues because of its ability to control cell growth. Its ionizing radiation damages the DNA of cancerous tissues, leading to cell death. Medical imaging, however, still has limitations regarding the reliability of its asses...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2019.2913766

    authors: Park JA,Kang KJ,Ko IO,Lee KC,Choi BK,Katoch N,Kim JW,Kim HJ,Kwon OI,Woo EJ

    更新日期:2019-12-01 00:00:00

  • Resampling of data between arbitrary grids using convolution interpolation.

    abstract::For certain medical applications resampling of data is required. In magnetic resonance tomography (MRT) or computer tomography (CT), e.g., data may be sampled on nonrectilinear grids in the Fourier domain. For the image reconstruction a convolution-interpolation algorithm, often called gridding, can be applied for res...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.774166

    authors: Rasche V,Proksa R,Sinkus R,Börnert P,Eggers H

    更新日期:1999-05-01 00:00:00

  • Prior-Attention Residual Learning for More Discriminative COVID-19 Screening in CT Images.

    abstract::We propose a conceptually simple framework for fast COVID-19 screening in 3D chest CT images. The framework can efficiently predict whether or not a CT scan contains pneumonia while simultaneously identifying pneumonia types between COVID-19 and Interstitial Lung Disease (ILD) caused by other viruses. In the proposed ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2020.2994908

    authors: Wang J,Bao Y,Wen Y,Lu H,Luo H,Xiang Y,Li X,Liu C,Qian D

    更新日期:2020-08-01 00:00:00

  • Head Motion Correction Based on Filtered Backprojection in Helical CT Scanning.

    abstract::Head motion may unexpectedly occur during a CT scan. It thereby results in motion artifacts in a reconstructed image and may lead to a false diagnosis or a failure of diagnosis. To alleviate this motion problem, as a hardware approach, increasing the gantry rotation speed or using an immobilization device is usually c...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2019.2953974

    authors: Jang S,Kim S,Kim M,Son K,Lee KY,Ra JB

    更新日期:2020-05-01 00:00:00

  • Curvelet based contrast enhancement in fluoroscopic sequences.

    abstract::Image guided interventions have seen growing interest in recent years. The use of X-rays for the procedure impels limiting the dose over time. Image sequences obtained thereby exhibit high levels of noise and very low contrasts. Hence, the development of efficient methods to enable optimal visualization of these seque...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2014.2349034

    authors: Amiot C,Girard C,Chanussot J,Pescatore J,Desvignes M

    更新日期:2015-01-01 00:00:00

  • Intensity-based image registration using robust correlation coefficients.

    abstract::The ordinary sample correlation coefficient is a popular similarity measure for aligning images from the same or similar modalities. However, this measure can be sensitive to the presence of "outlier" objects that appear in one image but not the other, such as surgical instruments, the patient table, etc., which can l...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2004.835313

    authors: Kim J,Fessler JA

    更新日期:2004-11-01 00:00:00

  • Three-dimensional microwave breast imaging: dispersive dielectric properties estimation using patient-specific basis functions.

    abstract::Breast imaging via microwave tomography involves estimating the distribution of dielectric properties within the patient's breast on a discrete mesh. The number of unknowns in the discrete mesh can be very large for 3-D imaging, and this results in computational challenges. We propose a new approach where the discrete...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2008.2008959

    authors: Winters DW,Shea JD,Kosmas P,Van Veen BD,Hagness SC

    更新日期:2009-07-01 00:00:00

  • Simulation of the expected performance of a seamless scanner for brain PET based on highly pixelated CdTe detectors.

    abstract::The aim of this work is the evaluation of the design for a nonconventional PET scanner, the voxel imaging PET (VIP), based on pixelated room-temperature CdTe detectors yielding a true 3-D impact point with a density of 450 channels/cm(3), for a total 6 336 000 channels in a seamless ring shaped volume. The system is s...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2013.2284657

    authors: Mikhaylova E,De Lorenzo G,Chmeissani M,Kolstein M,Cañadas M,Arce P,Calderón Y,Uzun D,Ariño G,Macias-Montero JG,Martinez R,Puigdengoles C,Cabruja E

    更新日期:2014-02-01 00:00:00

  • Tracking multiple particles in fluorescence time-lapse microscopy images via probabilistic data association.

    abstract::Tracking subcellular structures as well as viral structures displayed as 'particles' in fluorescence microscopy images yields quantitative information on the underlying dynamical processes. We have developed an approach for tracking multiple fluorescent particles based on probabilistic data association. The approach c...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2014.2359541

    authors: Godinez WJ,Rohr K

    更新日期:2015-02-01 00:00:00

  • Displacement estimation with co-registered ultrasound for image guided neurosurgery: a quantitative in vivo porcine study.

    abstract::Brain shift during open cranial surgery presents a challenge for maintaining registration with image-guidance systems. Ultrasound (US) is a convenient intraoperative imaging modality that may be a useful tool in detecting tissue shift and updating preoperative images based on intraoperative measurements of brain defor...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2003.819293

    authors: Lunn KE,Paulsen KD,Roberts DW,Kennedy FE,Hartov A,West JD

    更新日期:2003-11-01 00:00:00

  • Spatial transformation of DWI data using non-negative sparse representation.

    abstract::This paper presents an algorithm to transform and reconstruct diffusion-weighted imaging (DWI) data for alignment of micro-structures in association with spatial transformations. The key idea is to decompose the diffusion signal profile, a function defined on a unit sphere, into a series of weighted diffusion basis fu...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2012.2204766

    authors: Yap PT,Shen D

    更新日期:2012-11-01 00:00:00

  • Edge displacement field-based classification for improved detection of polyps in CT colonography.

    abstract::Colorectal cancer can easily be prevented provided that the precursors to tumors, small colonic polyps, are detected and removed. Currently, the only definitive examination of the colon is fiber-optic colonoscopy, which is invasive and expensive. Computed tomographic colonography (CTC) is potentially a less costly and...

    journal_title:IEEE transactions on medical imaging

    pub_type: 临床试验,杂志文章

    doi:10.1109/TMI.2002.806405

    authors: Acar B,Beaulieu CF,Göktürk SB,Tomasi C,Paik DS,Jeffrey RB Jr,Yee J,Napel S

    更新日期:2002-12-01 00:00:00

  • New perspectives on the sources of white matter DTI signal.

    abstract::A minimalist numerical model of white matter is presented, the objective of which is to help provide a biological basis for improved diffusion tensor imaging (DTI) analysis. Water diffuses, relaxes, and exchanges in three compartments-intracellular, extracellular, and myelin sheath. Exchange between compartments is de...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2007.906787

    authors: Peled S

    更新日期:2007-11-01 00:00:00

  • Automated segmentation of multiple sclerosis lesions by model outlier detection.

    abstract::This paper presents a fully automated algorithm for segmentation of multiple sclerosis (MS) lesions from multispectral magnetic resonance (MR) images. The method performs intensity-based tissue classification using a stochastic model for normal brain images and simultaneously detects MS lesions as outliers that are no...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.938237

    authors: Van Leemput K,Maes F,Vandermeulen D,Colchester A,Suetens P

    更新日期:2001-08-01 00:00:00

  • Computer-assisted scan protocol and reconstruction (CASPAR)-reduction of image noise and patient dose.

    abstract::X-ray computed tomography is a powerful medical imaging device. It allows high-resolution 3-D visualization of the human body. However, one drawback is the health risk associated with ionizing radiation. Simply downscaling the radiation intensities over the entire scan results in increased quantum noise. This paper pr...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2009.2034515

    authors: Sperl J,Beque D,Claus B,De Man B,Senzig B,Brokate M

    更新日期:2010-03-01 00:00:00

  • Feedback control of the nuclear magnetization state: modeling and control design.

    abstract::Magnetic resonance (MR) images are obtained by observing the fluctuations in nuclear magnetization produced by sequences of RF pulses and applied magnetic field gradients. The design of a pulse sequence is based on the expected response of the nuclear magnetization. Currently, all pulse sequence parameters are loaded ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.79471

    authors: Schiano JL,Magin RL,Wright SM

    更新日期:1991-01-01 00:00:00

  • Simultaneous Quantitative Imaging of Electrical Properties and Proton Density From B1 Maps Using MRI.

    abstract::Electrical conductivity and permittivity of biological tissues are important diagnostic parameters and are useful for calculating subject-specific specific absorption rate distribution. On the other hand, water proton density also has clinical relevance for diagnosis purposes. These two kinds of tissue properties are ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2016.2547988

    authors: Jiaen Liu,Van de Moortele PF,Xiaotong Zhang,Yicun Wang,Bin He

    更新日期:2016-09-01 00:00:00

  • An efficient optimization framework for multi-region segmentation based on Lagrangian duality.

    abstract::We introduce a multi-region model for simultaneous segmentation of medical images. In contrast to many other models, geometric constraints such as inclusion and exclusion between the regions are enforced, which makes it possible to correctly segment different regions even if the intensity distributions are identical. ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2012.2218117

    authors: Ulén J,Strandmark P,Kahl F

    更新日期:2013-02-01 00:00:00

  • Learning Geodesic Active Contours for Embedding Object Global Information in Segmentation CNNs.

    abstract::Most existing CNNs-based segmentation methods rely on local appearances learned on the regular image grid, without consideration of the object global information. This article aims to embed the object global geometric information into a learning framework via the classical geodesic active contours (GAC). We propose a ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2020.3022693

    authors: Ma J,He J,Yang X

    更新日期:2021-01-01 00:00:00

  • Retinal vessel centerline extraction using multiscale matched filters, confidence and edge measures.

    abstract::Motivated by the goals of improving detection of low-contrast and narrow vessels and eliminating false detections at nonvascular structures, a new technique is presented for extracting vessels in retinal images. The core of the technique is a new likelihood ratio test that combines matched-filter responses, confidence...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/tmi.2006.884190

    authors: Sofka M,Stewart CV

    更新日期:2006-12-01 00:00:00

  • Vulnerable atherosclerotic plaque elasticity reconstruction based on a segmentation-driven optimization procedure using strain measurements: theoretical framework.

    abstract::It is now recognized that prediction of the vulnerable coronary plaque rupture requires not only an accurate quantification of fibrous cap thickness and necrotic core morphology but also a precise knowledge of the mechanical properties of plaque components. Indeed, such knowledge would allow a precise evaluation of th...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2009.2012852

    authors: Le Floc'h S,Ohayon J,Tracqui P,Finet G,Gharib AM,Maurice RL,Cloutier G,Pettigrew RI

    更新日期:2009-07-01 00:00:00

  • 4-D Reconstruction With Respiratory Correction for Gated Myocardial Perfusion SPECT.

    abstract::Cardiac single photon emission computed tomography (SPECT) images are known to suffer from both cardiac and respiratory motion blur. In this paper, we investigate a 4-D reconstruction approach to suppress the effect of respiratory motion in gated cardiac SPECT imaging. In this approach, the sequence of cardiac gated i...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2017.2690819

    authors: Qi W,Yang Y,Song C,Wernick MN,Pretorius PH,King MA

    更新日期:2017-08-01 00:00:00

  • Improving Blood Vessel Tortuosity Measurements via Highly Sampled Numerical Integration of the Frenet-Serret Equations.

    abstract::Measures of vascular tortuosity-how curved and twisted a vessel is-are associated with a variety of vascular diseases. Consequently, measurements of vessel tortuosity that are accurate and comparable across modality, resolution, and size are greatly needed. Yet in practice, precise and consistent measurements are prob...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2020.3025467

    authors: Brummer AB,Hunt D,Savage V

    更新日期:2021-01-01 00:00:00

  • GPU-based real-time volumetric ultrasound image reconstruction for a ring array.

    abstract::Synthetic phased array (SPA) beamforming with Hadamard coding and aperture weighting is an optimal option for real-time volumetric imaging with a ring array, a particularly attractive geometry in intracardiac and intravascular applications. However, the imaging frame rate of this method is limited by the immense compu...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2013.2253117

    authors: Choe JW,Nikoozadeh A,Oralkan O,Khuri-Yakub BT

    更新日期:2013-07-01 00:00:00

  • Multi-TI Arterial Spin Labeling MRI with Variable TR and Bolus Duration for Cerebral Blood Flow and Arterial Transit Time Mapping.

    abstract::Arterial spin labeling (ASL) is an MRI perfusion imaging method from which quantitative cerebral blood flow (CBF) can be calculated. We present a multi-TI ASL method (multi-TI integrated ASL) in which variable post-labeling delays and variable TRs are used to improve the estimation of arterial transit time (ATT) and C...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2015.2395257

    authors: Johnston ME,Lu K,Maldjian JA,Jung Y

    更新日期:2015-06-01 00:00:00