Toward Electrical Impedance Tomography Coupled Ultrasound Imaging for Assessing Muscle Health.

Abstract:

:This paper establishes for the first time that a coupled ultrasound (US) and electrical impedance tomography (EIT) system can serve as a non-invasive, spatially localized approach to extract clinically relevant muscle properties. The US/EIT system represents a potential enhancement to electrical impedance myography (EIM), which has shown promise as a non-invasive technology that may have important clinical use in indicating neuromuscular disease status and as a diagnostic tool. A 2.5D EIT algorithm evaluated on simulation, measured phantoms, and measured patient data was studied to evaluate US/EIT's ability to distinguish different aspects of muscle tissue. Simulated and phantom experiments revealed the depths of distinguishability of 3.2 and 4.2 mm in simulation for 10% and 20% changes in muscle properties, respectively, and 3.6 mm in measured phantom experiments assuming a 12% muscle conductivity change. Reconstructions from the patient data established that there were consistent differences 1) between longitudinal (along) and transverse (across) muscle conductivity reconstructions at frequencies of 40 and 80 kHz and 2) side-by-side comparison between healthy and diseased tissue in terms of conductivity, permittivity, and phase at 40 and 80 kHz. Comparisons were made between the EIT reconstructed values and electrical impedance spectroscopy (EIS) measurements (an available surrogate in place of standard EIM measurements) made with the US/EIT system, wherein 1) EIS and EIT show similar sensitivity to longitudinal and transverse differences and 2) EIT showed a more consistent ability to differentiate healthy and diseased tissue. These results suggest that US/EIT appears very promising for non-invasive and spatially localized diagnosis of muscle health.

journal_name

IEEE Trans Med Imaging

authors

Murphy EK,Skinner J,Martucci M,Rutkove SB,Halter RJ

doi

10.1109/TMI.2018.2886152

subject

Has Abstract

pub_date

2019-06-01 00:00:00

pages

1409-1419

issue

6

eissn

0278-0062

issn

1558-254X

journal_volume

38

pub_type

杂志文章
  • Estimating average growth trajectories in shape-space using kernel smoothing.

    abstract::In this paper, we show how a dense surface point distribution model of the human face can be computed and demonstrate the usefulness of the high-dimensional shape-space for expressing the shape changes associated with growth and aging. We show how average growth trajectories for the human face can be computed in the a...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2003.814784

    authors: Hutton TJ,Buxton BF,Hammond P,Potts HW

    更新日期:2003-06-01 00:00:00

  • Low-Rank Atlas Image Analyses in the Presence of Pathologies.

    abstract::We present a common framework, for registering images to an atlas and for forming an unbiased atlas, that tolerates the presence of pathologies such as tumors and traumatic brain injury lesions. This common framework is particularly useful when a sufficient number of protocol-matched scans from healthy subjects cannot...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2015.2448556

    authors: Liu X,Niethammer M,Kwitt R,Singh N,McCormick M,Aylward S

    更新日期:2015-12-01 00:00:00

  • Simulation and Synthesis in Medical Imaging.

    abstract::This editorial introduces the Special Issue on Simulation and Synthesis in Medical Imaging. In this editorial, we define so-far ambiguous terms of simulation and synthesis in medical imaging. We also briefly discuss the synergistic importance of mechanistic (hypothesis-driven) and phenomenological (data-driven) models...

    journal_title:IEEE transactions on medical imaging

    pub_type: 社论

    doi:10.1109/TMI.2018.2800298

    authors: Frangi AF,Tsaftaris SA,Prince JL

    更新日期:2018-03-01 00:00:00

  • Analysis of noise properties of a class of exact methods of inverting the 2-D exponential radon transform [SPECT application].

    abstract::A general approach that the authors proposed elsewhere reveals the intrinsic relationship among methods for inversion of the 2-D exponential Radon transform described by Bellini et al. (1979), by Tretiak and Metz (1980), by Hawkins et al. (1988), and by Inouye et al. (1989). Moreover, the authors' approach provides an...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.476107

    authors: Pan X,Metz CE

    更新日期:1995-01-01 00:00:00

  • 4-D Reconstruction With Respiratory Correction for Gated Myocardial Perfusion SPECT.

    abstract::Cardiac single photon emission computed tomography (SPECT) images are known to suffer from both cardiac and respiratory motion blur. In this paper, we investigate a 4-D reconstruction approach to suppress the effect of respiratory motion in gated cardiac SPECT imaging. In this approach, the sequence of cardiac gated i...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2017.2690819

    authors: Qi W,Yang Y,Song C,Wernick MN,Pretorius PH,King MA

    更新日期:2017-08-01 00:00:00

  • Parametric estimate of intensity inhomogeneities applied to MRI.

    abstract::This paper presents a new approach to the correction of intensity inhomogeneities in magnetic resonance imaging (MRI) that significantly improves intensity-based tissue segmentation. The distortion of the image brightness values by a low-frequency bias field impedes visual inspection and segmentation. The new correcti...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.845174

    authors: Styner M,Brechbühler C,Székely G,Gerig G

    更新日期:2000-03-01 00:00:00

  • Intensity-based image registration using robust correlation coefficients.

    abstract::The ordinary sample correlation coefficient is a popular similarity measure for aligning images from the same or similar modalities. However, this measure can be sensitive to the presence of "outlier" objects that appear in one image but not the other, such as surgical instruments, the patient table, etc., which can l...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2004.835313

    authors: Kim J,Fessler JA

    更新日期:2004-11-01 00:00:00

  • Vessel surface reconstruction with a tubular deformable model.

    abstract::Three-dimensional (3-D) angiographic methods are gaining acceptance for evaluation of atherosclerotic disease. However, measurement of vessel stenosis from 3-D angiographic methods can be problematic due to limited image resolution and contrast. We present a method for reconstructing vessel surfaces from 3-D angiograp...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.974935

    authors: Yim PJ,Cebral JJ,Mullick R,Marcos HB,Choyke PL

    更新日期:2001-12-01 00:00:00

  • Ultrafast Doppler imaging of blood flow dynamics in the myocardium.

    abstract::Imaging intramyocardial vascular flows in real-time could strongly help to achieve better diagnostic of cardiovascular diseases. To date, no standard imaging modality allows describing accurately myocardial blood flow dynamics with good spatial and temporal resolution. We recently introduced a novel ultrasonic Doppler...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2012.2203316

    authors: Osmanski BF,Pernot M,Montaldo G,Bel A,Messas E,Tanter M

    更新日期:2012-08-01 00:00:00

  • A filtered backprojection algorithm for triple-source helical cone-beam CT.

    abstract::Multisource cone-beam computed tomography (CT) is an attractive approach of choice for superior temporal resolution, which is critically important for cardiac imaging and contrast enhanced studies. In this paper, we present a filtered-backprojection (FBP) algorithm for triple-source helical cone-beam CT. The algorithm...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2008.2004817

    authors: Zhao J,Jin Y,Lu Y,Wang G

    更新日期:2009-03-01 00:00:00

  • An optimization transfer algorithm for nonlinear parametric image reconstruction from dynamic PET data.

    abstract::Direct reconstruction of kinetic parameters from raw projection data is a challenging task in molecular imaging using dynamic positron emission tomography (PET). This paper presents a new optimization transfer algorithm for penalized likelihood direct reconstruction of nonlinear parametric images that is easy to use a...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2012.2212203

    authors: Wang G,Qi J

    更新日期:2012-10-01 00:00:00

  • Learning Domain Shift in Simulated and Clinical Data: Localizing the Origin of Ventricular Activation From 12-Lead Electrocardiograms.

    abstract::Building a data-driven model to localize the origin of ventricular activation from 12-lead electrocardiograms (ECG) requires addressing the challenge of large anatomical and physiological variations across individuals. The alternative of a patient-specific model is, however, difficult to implement in clinical practice...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2018.2880092

    authors: Alawad M,Wang L

    更新日期:2019-05-01 00:00:00

  • Cap-Based Transcranial Optical Tomography in an Awake Infant.

    abstract::Although Blood Oxygenation Level Dependent (BOLD) functional MRI (fMRI) is widely used to examine brain function in adults, the need for general anesthesia limits its practical utility in infants and small children. Functional Near-Infrared Spectroscopy - Diffuse Optical Tomography (fNIRS-DOT) imaging promises to be a...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2020.2990823

    authors: Zhu B,Sevick-Muraca EM,Nguyen RD,Shah MN

    更新日期:2020-11-01 00:00:00

  • A Kernel-Based Low-Rank (KLR) Model for Low-Dimensional Manifold Recovery in Highly Accelerated Dynamic MRI.

    abstract::While many low rank and sparsity-based approaches have been developed for accelerated dynamic magnetic resonance imaging (dMRI), they all use low rankness or sparsity in input space, overlooking the intrinsic nonlinear correlation in most dMRI data. In this paper, we propose a kernel-based framework to allow nonlinear...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2017.2723871

    authors: Nakarmi U,Wang Y,Lyu J,Liang D,Ying L

    更新日期:2017-11-01 00:00:00

  • Simultaneous MR-compatible emission and transmission imaging for PET using time-of-flight information.

    abstract::Quantitative positron emission tomography (PET) imaging relies on accurate attenuation correction. Predicting attenuation values from magnetic resonance (MR) images is difficult because MR signals are related to proton density and relaxation properties of tissues. Here, we propose a method to derive the attenuation ma...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2012.2198831

    authors: Mollet P,Keereman V,Clementel E,Vandenberghe S

    更新日期:2012-09-01 00:00:00

  • Multi-scale tubular structure detection in ultrasound imaging.

    abstract::We propose a novel, physics-based method for detecting multi-scale tubular features in ultrasound images. The detector is based on a Hessian-matrix eigenvalue method, but unlike previous work, our detector is guided by an optimal model of vessel-like structures with respect to the ultrasound-image formation process. O...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2014.2340912

    authors: Hennersperger C,Baust M,Waelkens P,Karamalis A,Ahmadi SA,Navab N

    更新日期:2015-01-01 00:00:00

  • Dynamic contrast-enhanced MRI-based early detection of acute renal transplant rejection.

    abstract::A novel framework for the classification of acute rejection versus nonrejection status of renal transplants from 2-D dynamic contrast-enhanced magnetic resonance imaging is proposed. The framework consists of four steps. First, kidney objects are segmented from adjacent structures with a level set deformable boundary ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2013.2269139

    authors: Khalifa F,Beache GM,El-Ghar MA,El-Diasty T,Gimel'farb G,Kong M,El-Baz A

    更新日期:2013-10-01 00:00:00

  • Prior-Attention Residual Learning for More Discriminative COVID-19 Screening in CT Images.

    abstract::We propose a conceptually simple framework for fast COVID-19 screening in 3D chest CT images. The framework can efficiently predict whether or not a CT scan contains pneumonia while simultaneously identifying pneumonia types between COVID-19 and Interstitial Lung Disease (ILD) caused by other viruses. In the proposed ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2020.2994908

    authors: Wang J,Bao Y,Wen Y,Lu H,Luo H,Xiang Y,Li X,Liu C,Qian D

    更新日期:2020-08-01 00:00:00

  • 3-D Contrast Source Inversion-Electrical Properties Tomography.

    abstract::Contrast source inversion-electrical properties tomography (CSI-EPT) is an iterative reconstruction method to retrieve the electrical properties (EPs) of tissues from magnetic resonance data. The method is based on integral representations of the electromagnetic field and has been shown to allow EP reconstructions of ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2018.2816125

    authors: Leijsen RL,Brink WM,van den Berg CAT,Webb AG,Remis RF

    更新日期:2018-09-01 00:00:00

  • In situ characterization of the degradation of PLGA microspheres in hyaluronic acid hydrogels by optical coherence tomography.

    abstract::The polymeric implant material poly(lactide-co-glycolide) (PLGA) degrades by a process of bulk degradation, which allows it to be used for the controlled release of therapeutic molecules from implants and microspheres. The temporal characterization of PLGA microsphere degradation has been limited by the need to destru...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2008.927356

    authors: Patterson J,Stayton PS,Li X

    更新日期:2009-01-01 00:00:00

  • Advanced level-set-based cell tracking in time-lapse fluorescence microscopy.

    abstract::Cell segmentation and tracking in time-lapse fluorescence microscopy images is a task of fundamental importance in many biological studies on cell migration and proliferation. In recent years, level sets have been shown to provide a very appropriate framework for this purpose, as they are well suited to capture topolo...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2009.2038693

    authors: Dzyubachyk O,van Cappellen WA,Essers J,Niessen WJ,Meijering E

    更新日期:2010-03-01 00:00:00

  • Implementation, investigation, and improvement of a novel cone-beam reconstruction method [SPECT].

    abstract::A three-dimensional reconstruction method which uses cone-beam data was implemented. Issues concerning implementation are investigated and discussed in detail. Computer simulations were used to determine the amount of image degradation occurring in each of the three steps that comprise the reconstruction method. In ad...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.141650

    authors: Smith BD,Chen J

    更新日期:1992-01-01 00:00:00

  • Unsupervised Learning for Robust Respiratory Signal Estimation From X-Ray Fluoroscopy.

    abstract::Respiratory signals are required for image gating and motion compensation in minimally invasive interventions. In X-ray fluoroscopy, extraction of a respiratory signal can be challenging due to characteristics of interventional imaging, in particular injection of contrast agent and automatic exposure control. We prese...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2016.2609888

    authors: Fischer P,Pohl T,Faranesh A,Maier A,Hornegger J

    更新日期:2017-04-01 00:00:00

  • Monitoring Acute Stroke Progression: Multi-Parametric OCT Imaging of Cortical Perfusion, Flow, and Tissue Scattering in a Mouse Model of Permanent Focal Ischemia.

    abstract::Cerebral ischemic stroke causes injury to brain tissue characterized by a complex cascade of neuronal and vascular events. Imaging during the early stages of its development allows prediction of tissue infarction and penumbra so that optimal intervention can be determined in order to salvage brain function impairment....

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2019.2895779

    authors: Choi WJ,Li Y,Wang RK

    更新日期:2019-06-01 00:00:00

  • Twenty new digital brain phantoms for creation of validation image data bases.

    abstract::Simulations provide a way of generating data where ground truth is known, enabling quantitative testing of image processing methods. In this paper, we present the construction of 20 realistic digital brain phantoms that can be used to simulate medical imaging data. The phantoms are made from 20 normal adults to take i...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2006.883453

    authors: Aubert-Broche B,Griffin M,Pike GB,Evans AC,Collins DL

    更新日期:2006-11-01 00:00:00

  • Reconstruction and quantification of the carotid artery bifurcation from 3-D ultrasound images.

    abstract::Three-dimensional (3-D) ultrasound is a relatively new technique, which is well suited to imaging superficial blood vessels, and potentially provides a useful, noninvasive method for generating anatomically realistic 3-D models of the peripheral vasculature. Such models are essential for accurate simulation of blood f...

    journal_title:IEEE transactions on medical imaging

    pub_type: 临床试验,杂志文章

    doi:10.1109/tmi.2004.825601

    authors: Barratt DC,Ariff BB,Humphries KN,Thom SA,Hughes AD

    更新日期:2004-05-01 00:00:00

  • Bayesian approach for a robust speed-of-sound reconstruction using pulse-echo ultrasound.

    abstract::Computed ultrasound tomography in echo mode (CUTE) is a promising ultrasound (US) based multi-modal technique that allows to image the spatial distribution of speed of sound (SoS) inside tissue using hand-held pulse-echo US. It is based on measuring the phase shift of echoes when detected under varying steering angles...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2020.3029286

    authors: Stahli PS,Frenz M,Jaeger M

    更新日期:2020-10-07 00:00:00

  • The n-PI-method for helical cone-beam CT.

    abstract::A new class of acquisition schemes for helical cone-beam computed tomography (CB-CT) scanning is introduced, and their effect on the reconstruction methods is analyzed. These acquisition schemes are based on a new detector shape that is bounded by the helix. It will be shown that the data acquired with these schemes a...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.887834

    authors: Proksa R,Köhler T,Grass M,Timmer J

    更新日期:2000-09-01 00:00:00

  • Simulation of the expected performance of a seamless scanner for brain PET based on highly pixelated CdTe detectors.

    abstract::The aim of this work is the evaluation of the design for a nonconventional PET scanner, the voxel imaging PET (VIP), based on pixelated room-temperature CdTe detectors yielding a true 3-D impact point with a density of 450 channels/cm(3), for a total 6 336 000 channels in a seamless ring shaped volume. The system is s...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2013.2284657

    authors: Mikhaylova E,De Lorenzo G,Chmeissani M,Kolstein M,Cañadas M,Arce P,Calderón Y,Uzun D,Ariño G,Macias-Montero JG,Martinez R,Puigdengoles C,Cabruja E

    更新日期:2014-02-01 00:00:00

  • Discriminative segmentation-based evaluation through shape dissimilarity.

    abstract::Segmentation-based scores play an important role in the evaluation of computational tools in medical image analysis. These scores evaluate the quality of various tasks, such as image registration and segmentation, by measuring the similarity between two binary label maps. Commonly these measurements blend two aspects ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2012.2216281

    authors: Konukoglu E,Glocker B,Ye DH,Criminisi A,Pohl KM

    更新日期:2012-12-01 00:00:00