Dynamic contrast-enhanced MRI-based early detection of acute renal transplant rejection.

Abstract:

:A novel framework for the classification of acute rejection versus nonrejection status of renal transplants from 2-D dynamic contrast-enhanced magnetic resonance imaging is proposed. The framework consists of four steps. First, kidney objects are segmented from adjacent structures with a level set deformable boundary guided by a stochastic speed function that accounts for a fourth-order Markov-Gibbs random field model of the kidney/background shape and appearance. Second, a Laplace-based nonrigid registration approach is used to account for local deformations caused by physiological effects. Namely, the target kidney object is deformed over closed, equispaced contours (iso-contours) to closely match the reference object. Next, the cortex is segmented as it is the functional kidney unit that is most affected by rejection. To characterize rejection, perfusion is estimated from contrast agent kinetics using empirical indexes, namely, the transient phase indexes (peak signal intensity, time-to-peak, and initial up-slope), and a steady-phase index defined as the average signal change during the slowly varying tissue phase of agent transit. We used a kn-nearest neighbor classifier to distinguish between acute rejection and nonrejection. Performance of our method was evaluated using the receiver operating characteristics (ROC). Experimental results in 50 subjects, using a combinatoric kn-classifier, correctly classified 92% of training subjects, 100% of the test subjects, and yielded an area under the ROC curve that approached the ideal value. Our proposed framework thus holds promise as a reliable noninvasive diagnostic tool.

journal_name

IEEE Trans Med Imaging

authors

Khalifa F,Beache GM,El-Ghar MA,El-Diasty T,Gimel'farb G,Kong M,El-Baz A

doi

10.1109/TMI.2013.2269139

subject

Has Abstract

pub_date

2013-10-01 00:00:00

pages

1910-27

issue

10

eissn

0278-0062

issn

1558-254X

journal_volume

32

pub_type

杂志文章
  • Solving the Bloch equation with periodic excitation using harmonic balancing: application to Rabi modulated excitation.

    abstract::In waveform design for magnetic resonance applications, periodic continuous-wave excitation offers potential advantages that remain largely unexplored because of a lack of understanding of the Bloch equation with periodic continuous-wave excitations. Using harmonic balancing techniques the steady state solutions of th...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2015.2423313

    authors: Tahayori B,Johnston LA,Layton KJ,Farrell PM,Mareels IM

    更新日期:2015-10-01 00:00:00

  • Exact frequency-domain reconstruction for thermoacoustic tomography--II: Cylindrical geometry.

    abstract::Microwave-induced thermoacoustic tomography (TAT) in a cylindrical configuration is developed to image biological tissue. Thermoacoustic signals are acquired by scanning a flat ultrasonic transducer. Using a new expansion of a spherical wave in cylindrical coordinates, we apply the Fourier and Hankel transforms to TAT...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2002.801171

    authors: Xu Y,Xu M,Wang LV

    更新日期:2002-07-01 00:00:00

  • Learning-based deformable registration of MR brain images.

    abstract::This paper presents a learning-based method for deformable registration of magnetic resonance (MR) brain images. There are two novelties in the proposed registration method. First, a set of best-scale geometric features are selected for each point in the brain, in order to facilitate correspondence detection during th...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/tmi.2006.879320

    authors: Wu G,Qi F,Shen D

    更新日期:2006-09-01 00:00:00

  • Framing U-Net via Deep Convolutional Framelets: Application to Sparse-View CT.

    abstract::X-ray computed tomography (CT) using sparse projection views is a recent approach to reduce the radiation dose. However, due to the insufficient projection views, an analytic reconstruction approach using the filtered back projection (FBP) produces severe streaking artifacts. Recently, deep learning approaches using l...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2018.2823768

    authors: Han Y,Ye JC

    更新日期:2018-06-01 00:00:00

  • Neuron Segmentation With High-Level Biological Priors.

    abstract::We present a novel approach to the problem of neuron segmentation in image volumes acquired by an electron microscopy. Existing methods, such as agglomerative or correlation clustering, rely solely on boundary evidence and have problems where such an evidence is lacking (e.g., incomplete staining) or ambiguous (e.g., ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2017.2712360

    authors: Krasowski NE,Beier T,Knott GW,Kothe U,Hamprecht FA,Kreshuk A

    更新日期:2018-04-01 00:00:00

  • Lung 4D CT Image Registration Based on High-Order Markov Random Field.

    abstract::To solve the problem that traditional image registration methods based on continuous optimization for large motion lung 4D CT image sequences are easy to fall into local optimal solutions and lead to serious misregistration, a novel image registration method based on high-order Markov Random Field (MRF) is proposed. B...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2019.2937458

    authors: Xue P,Dong E,Ji H

    更新日期:2020-04-01 00:00:00

  • Anatomy and flow in normal and ischemic microvasculature based on a novel temporal fractal dimension analysis algorithm using contrast enhanced ultrasound.

    abstract::Strategies for improvement of blood flow by promoting new vessel growth in ischemic tissue are being developed. Recently, contrast-enhanced ultrasound (CEU) imaging has been used to assess tissue perfusion in models of ischemia-related angiogenesis, growth-factor mediated angiogenesis, and tumor angiogenesis. In these...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/tmi.2006.877442

    authors: Charalampidis D,Pascotto M,Kerut EK,Lindner JR

    更新日期:2006-08-01 00:00:00

  • Spherical harmonics microwave algorithm for shape and location reconstruction of breast cancer tumor.

    abstract::A reconstruction algorithm to simultaneously estimate the shape and location of three-dimensional breast cancer tumor is presented and its utility is analyzed. The approach is based on a spherical harmonic decomposition to capture the shape of the tumor. We combine a gradient descent optimization method with a direct ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/tmi.2006.881377

    authors: El-Shenawee M,Miller EL

    更新日期:2006-10-01 00:00:00

  • Simultaneous Morphological and Flow Imaging Enabled by Megahertz Intravascular Doppler Optical Coherence Tomography.

    abstract::We demonstrate three-dimensional intravascular flow imaging compatible with routine clinical image acquisition workflow by means of megahertz (MHz) intravascular Doppler Optical Coherence Tomography (OCT). The OCT system relies on a 1.1 mm diameter motorized imaging catheter and a 1.5 MHz Fourier Domain Mode Locked (F...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2019.2948258

    authors: Wang T,Pfeiffer T,Daemen J,Mastik F,Wieser W,van der Steen AFW,Huber R,van Soest G

    更新日期:2020-05-01 00:00:00

  • Progressive coding and transmission of digital diagnostic pictures.

    abstract::In radiology, as a result of the increased utilization of digital imaging modalities, such as computed tomography (CT) and magnetic resonance imaging (MRI), over a third of the images produced in a typical radiology department are currently in digital form, and this percentage is steadily increasing. Image compression...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.1986.4307750

    authors: Elnahas SE,Tzou KH,Cox JR,Hill RL,Jost R

    更新日期:1986-01-01 00:00:00

  • Image reconstruction in magnetic resonance conductivity tensor imaging (MRCTI).

    abstract::Almost all magnetic resonance electrical impedance tomography (MREIT) reconstruction algorithms proposed to date assume isotropic conductivity in order to simplify the image reconstruction. However, it is well known that most of biological tissues have anisotropic conductivity values. In this study, four novel anisotr...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2011.2171192

    authors: Değirmenci E,Eyüboğlu BM

    更新日期:2012-03-01 00:00:00

  • BICAV: a block-iterative parallel algorithm for sparse systems with pixel-related weighting.

    abstract::Component averaging (CAV) was recently introduced by Censor, Gordon, and Gordon as a new iterative parallel technique suitable for large and sparse unstructured systems of linear equations. Based on earlier work of Byrne and Censor, it uses diagonal weighting matrices, with pixel-related weights determined by the spar...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.959302

    authors: Censor Y,Gordon D,Gordon R

    更新日期:2001-10-01 00:00:00

  • Mixture model analysis of DNA microarray images.

    abstract::In this paper, we propose a new methodology for analysis of microarray images. First, a new gridding algorithm is proposed for determining the individual spots and their borders. Then, a Gaussian mixture model (GMM) approach is presented for the analysis of the individual spot images. The main advantages of the propos...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/tmi.2005.848358

    authors: Blekas K,Galatsanos NP,Likas A,Lagaris IE

    更新日期:2005-07-01 00:00:00

  • Elevation direction deconvolution in three-dimensional ultrasound imaging.

    abstract::One-dimensional (1-D) linear transducer arrays can be used for three-dimensional (3-D) ultrasound image acquisition. However, the relatively low spatial resolution of these arrays in the elevation direction results in blurry 3-D images. Here, the authors introduce an elevation direction deconvolution (EDD) method that...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.500148

    authors: Wang X,Ritchie CJ,Kim Y

    更新日期:1996-01-01 00:00:00

  • Imaging of cardiac movement using ratiometric and nonratiometric optical mapping: effects of ischemia and 2, 3-butaneodione monoxime.

    abstract::Transmembrane voltage-sensitive fluorescent dyes are used to study electrical activity in hearts. Green and red fluorescence emissions from di-4-ANEPPS excited with 488 nm light indicate both transmembrane voltage changes and heart movement. We have previously shown that the ratio, green fluorescence divided by red fl...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2005.861019

    authors: Himel HD 4th,Knisley SB

    更新日期:2006-01-01 00:00:00

  • Time-frequency MEG-MUSIC algorithm.

    abstract::We propose a method that incorporates the time-frequency characteristics of neural sources into magnetoencephalographic (MEG) source estimation. The method is based on the multiple-signal-classification (MUSIC) algorithm and it calculates a time--frequency matrix in which diagonal and off-diagonal terms are the auto a...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.750262

    authors: Sekihara K,Nagarajan S,Poeppel D,Miyashita Y

    更新日期:1999-01-01 00:00:00

  • Curvelet based contrast enhancement in fluoroscopic sequences.

    abstract::Image guided interventions have seen growing interest in recent years. The use of X-rays for the procedure impels limiting the dose over time. Image sequences obtained thereby exhibit high levels of noise and very low contrasts. Hence, the development of efficient methods to enable optimal visualization of these seque...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2014.2349034

    authors: Amiot C,Girard C,Chanussot J,Pescatore J,Desvignes M

    更新日期:2015-01-01 00:00:00

  • Bayesian approach for a robust speed-of-sound reconstruction using pulse-echo ultrasound.

    abstract::Computed ultrasound tomography in echo mode (CUTE) is a promising ultrasound (US) based multi-modal technique that allows to image the spatial distribution of speed of sound (SoS) inside tissue using hand-held pulse-echo US. It is based on measuring the phase shift of echoes when detected under varying steering angles...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2020.3029286

    authors: Stahli PS,Frenz M,Jaeger M

    更新日期:2020-10-07 00:00:00

  • Virtual tagging: numerical considerations and phantom validation.

    abstract::This paper presents a virtual tagging framework for measuring, as well as visualising, myocardial deformation using magnetic resonance (MR) velocity imaging. Tagging grids are allocated artificially according to the deformation gradient with varying shapes and densities. The control points are then deformed such that ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2002.804429

    authors: Masood S,Gao J,Yang GZ

    更新日期:2002-09-01 00:00:00

  • Improved watershed transform for medical image segmentation using prior information.

    abstract::The watershed transform has interesting properties that make it useful for many different image segmentation applications: it is simple and intuitive, can be parallelized, and always produces a complete division of the image. However, when applied to medical image analysis, it has important drawbacks (oversegmentation...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2004.824224

    authors: Grau V,Mewes AU,Alcañiz M,Kikinis R,Warfield SK

    更新日期:2004-04-01 00:00:00

  • A direct reconstruction algorithm for electrical impedance tomography.

    abstract::A direct (noniterative) reconstruction algorithm for electrical impedance tomography in the two-dimensional (2-D), cross-sectional geometry is reviewed. New results of a reconstruction of a numerically simulated phantom chest are presented. The algorithm is based on the mathematical uniqueness proof by A. I. Nachman [...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2002.800574

    authors: Mueller JL,Siltanen S,Isaacson D

    更新日期:2002-06-01 00:00:00

  • A filtered backprojection algorithm for triple-source helical cone-beam CT.

    abstract::Multisource cone-beam computed tomography (CT) is an attractive approach of choice for superior temporal resolution, which is critically important for cardiac imaging and contrast enhanced studies. In this paper, we present a filtered-backprojection (FBP) algorithm for triple-source helical cone-beam CT. The algorithm...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2008.2004817

    authors: Zhao J,Jin Y,Lu Y,Wang G

    更新日期:2009-03-01 00:00:00

  • Artifact trapping during time reversal photoacoustic imaging for acoustically heterogeneous media.

    abstract::Several different reconstruction algorithms have been proposed for photoacoustic tomography, most of which presuppose that the acoustic properties of the medium are constant and homogeneous. In practice, there are often unknown spatial variations in the acoustic properties, and these algorithms give, at best, only app...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2009.2032358

    authors: Cox BT,Treeby BE

    更新日期:2010-02-01 00:00:00

  • A multiple active contour model for cardiac boundary detection on echocardiographic sequences.

    abstract::Tracing of left-ventricular epicardial and endocardial borders on echocardiographic sequences is essential for quantification of cardiac function. The authors designed a method based on an extension of active contour models to detect both epicardial and endocardial borders on short-axis cardiac sequences spanning the ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.500138

    authors: Chalana V,Linker DT,Haynor DR,Kim Y

    更新日期:1996-01-01 00:00:00

  • Robust online orientation correction for radiographs in PACS environments.

    abstract::In picture archiving and communications systems (PACS), images need to be displayed in standardized ways for radiologists' interpretations. However, for most radiographs acquired via computed radiography (CR), digital radiography (DR), or digitized films, the image orientation is undetermined because of the variations...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/tmi.2006.880677

    authors: Luo H,Luo J

    更新日期:2006-10-01 00:00:00

  • Metrics for Assessing the Similarity of Microwave Breast Imaging Scans of Healthy Volunteers.

    abstract::Microwave radar imaging is promising as a complementary medical imaging modality. However, the unique nature of the images means interpretation can be difficult. As a result, it is important to understand the sources of image differences, and how much variability is inherent in the imaging system itself. To address th...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2018.2806878

    authors: Lavoie BR,Bourqui J,Fear EC,Okoniewski M

    更新日期:2018-08-01 00:00:00

  • Globally convergent image reconstruction for emission tomography using relaxed ordered subsets algorithms.

    abstract::We present two types of globally convergent relaxed ordered subsets (OS) algorithms for penalized-likelihood image reconstruction in emission tomography: modified block sequential regularized expectation-maximization (BSREM) and relaxed OS separable paraboloidal surrogates (OS-SPS). The global convergence proof of the...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2003.812251

    authors: Ahn S,Fessler JA

    更新日期:2003-05-01 00:00:00

  • Nonrigid image registration using conditional mutual information.

    abstract::Maximization of mutual information (MMI) is a popular similarity measure for medical image registration. Although its accuracy and robustness has been demonstrated for rigid body image registration, extending MMI to nonrigid image registration is not trivial and an active field of research. We propose conditional mutu...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2009.2021843

    authors: Loeckx D,Slagmolen P,Maes F,Vandermeulen D,Suetens P

    更新日期:2010-01-01 00:00:00

  • Super Wide-Field Photoacoustic Microscopy of Animals and Humans In Vivo.

    abstract::Acoustic-resolution photoacoustic micro-scopy (AR-PAM) is an emerging biomedical imaging modality that combines superior optical sensitivity and fine ultrasonic resolution in an optical quasi-diffusive regime (~1-3 mm in tissues). AR-PAM has been explored for anatomical, functional, and molecular information in biolog...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2019.2938518

    authors: Baik JW,Kim JY,Cho S,Choi S,Kim J,Kim C

    更新日期:2020-04-01 00:00:00

  • Adaptive speckle reduction filter for log-compressed B-scan images.

    abstract::A good statistical model of speckle formation is useful for designing a good adaptive filter for speckle reduction In ultrasound B-scan images. Previously, statistical models have been used, but they failed to account for the log compression of the echo envelope employed by clinical ultrasound systems. Log-compression...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.544498

    authors: Dutt V,Greenleaf JF

    更新日期:1996-01-01 00:00:00