Abstract:
:Quantitative positron emission tomography (PET) imaging relies on accurate attenuation correction. Predicting attenuation values from magnetic resonance (MR) images is difficult because MR signals are related to proton density and relaxation properties of tissues. Here, we propose a method to derive the attenuation map from a transmission scan. An annulus transmission source is positioned inside the field-of-view of the PET scanner. First a blank scan is acquired. The patient is injected with FDG and placed inside the scanner. 511-keV photons coming from the patient and the transmission source are acquired simultaneously. Time-of-flight information is used to extract the coincident photons originating from the annulus. The blank and transmission data are compared in an iterative reconstruction method to derive the attenuation map. Simulations with a digital phantom were performed to validate the method. The reconstructed attenuation coefficients differ less than 5% in volumes of interest inside the lungs, bone, and soft tissue. When applying attenuation correction in the reconstruction of the emission data a standardized uptake value error smaller than 9% was obtained for all tissues. In conclusion, our method can reconstruct the attenuation map and the emission data from a simultaneous scan without prior knowledge about the anatomy or the attenuation coefficients of the tissues.
journal_name
IEEE Trans Med Imagingjournal_title
IEEE transactions on medical imagingauthors
Mollet P,Keereman V,Clementel E,Vandenberghe Sdoi
10.1109/TMI.2012.2198831subject
Has Abstractpub_date
2012-09-01 00:00:00pages
1734-42issue
9eissn
0278-0062issn
1558-254Xjournal_volume
31pub_type
杂志文章abstract::Kidney stone disease is a major health problem worldwide. Shockwave lithotripsy (SWL), which uses high-energy shockwave pulses to break up kidney stones, is extensively used in clinic. However, despite its noninvasiveness, SWL can produce cavitation in vivo. The rapid expansion and violent collapse of cavitation bubbl...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2019.2928740
更新日期:2020-02-01 00:00:00
abstract::With continuing improvements in spatial resolution of positron emission tomography (PET) scanners, small patient movements during PET imaging become a significant source of resolution degradation. This work develops and investigates a comprehensive formalism for accurate motion-compensated reconstruction which at the ...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2008.917248
更新日期:2008-08-01 00:00:00
abstract::Spectral computed tomography (CT) provides information on material characterization and quantification because of its ability to separate different basis materials. Dual-energy (DE) CT provides two sets of measurements at two different source energies. In principle, two materials can be accurately decomposed from DECT...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2014.2320284
更新日期:2014-08-01 00:00:00
abstract::With the widespread use of positron emission tomography (PET) crystals with greatly improved energy resolution (e.g., 11.5% with LYSO as compared to 20% with BGO) and of list-mode acquisitions, the use of the energy of individual events in scatter correction schemes becomes feasible. We propose a novel scatter approac...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2010.2095025
更新日期:2011-03-01 00:00:00
abstract::Measures of vascular tortuosity-how curved and twisted a vessel is-are associated with a variety of vascular diseases. Consequently, measurements of vessel tortuosity that are accurate and comparable across modality, resolution, and size are greatly needed. Yet in practice, precise and consistent measurements are prob...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2020.3025467
更新日期:2021-01-01 00:00:00
abstract::Fluorescence loss in photobleaching (FLIP) is a method to study compartment connectivity in living cells. A FLIP sequence is obtained by alternatively bleaching a spot in a cell and acquiring an image of the complete cell. Connectivity is estimated by comparing fluorescence signal attenuation in different cell parts. ...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2011.2171497
更新日期:2012-02-01 00:00:00
abstract::In this paper, we formulate a reconstruction algorithm for an n-Pi acquisition, where n can be any positive odd integer. The algorithm is a generalization of the method presented in (Bontus et al. 2003). It is based on the results obtained by Katsevich (2004). For the algorithm, different sets of filter-lines have to ...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2005.850545
更新日期:2005-08-01 00:00:00
abstract::Tracking subcellular structures as well as viral structures displayed as 'particles' in fluorescence microscopy images yields quantitative information on the underlying dynamical processes. We have developed an approach for tracking multiple fluorescent particles based on probabilistic data association. The approach c...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2014.2359541
更新日期:2015-02-01 00:00:00
abstract::Dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) of the breast has become an invaluable tool in the clinical work-up of patients suspected of having breast carcinoma. The purpose of this study is to introduce novel features extracted from the kinetics of contrast agent uptake imaged by a short (100 s) vi...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2013.2281984
更新日期:2014-02-01 00:00:00
abstract::The multi-channel nature of digital histopathological images presents an opportunity to exploit the correlated color channel information for better image modeling. Inspired by recent work in sparsity for single channel image classification, we propose a new simultaneous sparsity model for multi-channel histopathologic...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2014.2306173
更新日期:2014-05-01 00:00:00
abstract::High peak RF amplitude and excessive specific absorption rate (SAR) are two critical concerns for hardware implementation and patient safety in scientific and clinical research for high field MRI using parallel transmissions (pTX). In this paper, we introduce a squeezing strategy to reduce peak RF amplitude and integr...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2018.2828112
更新日期:2018-08-01 00:00:00
abstract::Two methods for recovering an image that has been degraded while being processed are presented. The restoration problem is formulated as a constrained optimization problem in which a measure of smoothness based on the second derivatives of the restored image is maximized subject to the constraint that noise energy is ...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.126904
更新日期:1992-01-01 00:00:00
abstract::Magnetic resonance imaging (MRI) on patients with implanted deep brain stimulators (DBSs) can be hazardous because of the antenna-effect of leads exposed to the incident radio-frequency field. This study evaluated electromagnetic field and specific absorption rate (SAR) changes as a function of lead resistivity on an ...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2010.2040624
更新日期:2010-04-01 00:00:00
abstract::Groupwise nonrigid image registration is a powerful tool to automatically establish correspondences across sets of images. Such correspondences are widely used for constructing statistical models of shape and appearance. As existing techniques usually treat registration as an optimization problem, a good initializatio...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2011.2169077
更新日期:2012-02-01 00:00:00
abstract::Glaucoma is a chronic eye disease that leads to irreversible vision loss. The cup to disc ratio (CDR) plays an important role in the screening and diagnosis of glaucoma. Thus, the accurate and automatic segmentation of optic disc (OD) and optic cup (OC) from fundus images is a fundamental task. Most existing methods s...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2018.2791488
更新日期:2018-07-01 00:00:00
abstract::Dynamic systems have proven to be well suited to describe a broad spectrum of human coordination behavior such synchronization with auditory stimuli. Simultaneous measurements of the spatiotemporal dynamics of electroencephalographic (EEG) and magnetoencephalographic (MEG) data reveals that the dynamics of the brain s...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2002.1009385
更新日期:2002-05-01 00:00:00
abstract::A system for digital flashing tomosynthesis (DFTS) consists of four ECG-gated simultaneously flashed X-ray tubes, a 14-in image intensifier, a unit for digital subtraction angiography (DSA), a PC-hosted transputer network for three-dimensional (3-D) reconstruction as well as for quantitative coronary angiography and v...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.232261
更新日期:1993-01-01 00:00:00
abstract::A true three-dimensional cone-beam reconstruction (TTCR) algorithm for direct volume image reconstruction from 2-D cone-beam projections is developed for the complete sphere geometry. The algorithm is derived from the parallel-beam true three-dimensional reconstruction (TTR) algorithm and is based on the modified filt...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.41483
更新日期:1989-01-01 00:00:00
abstract::In this paper, we present a two-stage algorithm for mammogram registration, the geometrical alignment of mammogram sequences. The rationale behind this paper stems from the intrinsic difficulties in comparing mammogram sequences. Mammogram comparison is a valuable tool in national breast screening programs as well as ...
journal_title:IEEE transactions on medical imaging
pub_type: 临床试验,杂志文章
doi:10.1109/TMI.2005.848374
更新日期:2005-06-01 00:00:00
abstract::A software system, CTIP, written in Fortran is discussed which remaps the computerized tomography (CT) image gray level so that both the lung and heart regions are clearly visible with a "natural anatomical appearance." The system is adaptive to image statistics derived from the gray-level histogram of the entire imag...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.1986.4307736
更新日期:1986-01-01 00:00:00
abstract::Interpretation of magnetic resonance angiography (MRA) is problematic due to complexities of vascular shape and to artifacts such as the partial volume effect. We present new methods to assist in the interpretation of MRA. These include methods for detection of vessel paths and for determination of branching patterns ...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章,评审
doi:10.1109/42.870662
更新日期:2000-06-01 00:00:00
abstract::An accurate diagnosis of burns and pressure ulcers in the early stages can be made by computerized image processing. This study describes a critical assessment of potential methodologies for noninvasive wound evaluation using a color imaging system. We also developed a method for quantifying histological readings and ...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.552057
更新日期:1997-02-01 00:00:00
abstract::This paper presents a new variational method for the segmentation of a moving object against a still background, over a sequence of [two-dimensional or three-dimensional (3-D)] image frames. The method is illustrated in application to myocardial gated single photon emission computed tomography (SPECT) data, and incorp...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.932748
更新日期:2001-07-01 00:00:00
abstract::Respiratory motion remains a significant source of errors in treatment planning for the thorax and upper abdomen. Recently, we proposed a method to estimate two-dimensional (2-D) object motion from a sequence of slowly rotating X-ray projection views, which we called deformation from orbiting views (DOVs). In this met...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2006.889719
更新日期:2007-02-01 00:00:00
abstract::Cell segmentation and tracking in time-lapse fluorescence microscopy images is a task of fundamental importance in many biological studies on cell migration and proliferation. In recent years, level sets have been shown to provide a very appropriate framework for this purpose, as they are well suited to capture topolo...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2009.2038693
更新日期:2010-03-01 00:00:00
abstract::To reconstruct electrical activity in the heart from body-surface electrocardiograms (ECGs) is an ill-posed inverse problem. Electrophysiological models have been found effective in regularizing these inverse problems by incorporating a priori knowledge about how the electrical potential in the heart propagates over t...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2019.2906600
更新日期:2019-11-01 00:00:00
abstract::The geometric component of the point spread function (PSF) of a gamma camera collimator can be determined analytically, and the penetration component can be calculated readily by numerical ray-tracing. A Monte Carlo simulation of photon transport which includes collimator scatter is developed. The simulation was imple...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.61758
更新日期:1990-01-01 00:00:00
abstract::In the PET system a block detector, which is a position-sensitive photomultiplier (PMT) tube coupled to four arrays of 1.7-mm-wide BGO crystals, is utilized. Fifteen block detectors are positioned to form a 35-cm-diameter ring, with four BGO arrays coupled to each PMT. This provides four detector rings, giving the sys...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.192694
更新日期:1992-01-01 00:00:00
abstract::In this paper, we are interested in soft tissue differentiation by multiband images obtained from the High-Resolution Ultrasonic Transmission Tomography (HUTT) system using a spectral target detection method based on constrained energy minimization (CEM). We have developed a new tissue differentiation method (called "...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/tmi.2004.843179
更新日期:2005-03-01 00:00:00
abstract::Radio-frequency current density imaging (RF-CDI) is an imaging technique that noninvasively measures current density distribution at the Larmor frequency utilizing magnetic resonance imaging (MRI). Previously implemented RF-CDI techniques were only able to image a single slice transverse to the static magnetic field B...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2008.2012161
更新日期:2009-07-01 00:00:00