Abstract:
:Radio-frequency current density imaging (RF-CDI) is an imaging technique that noninvasively measures current density distribution at the Larmor frequency utilizing magnetic resonance imaging (MRI). Previously implemented RF-CDI techniques were only able to image a single slice transverse to the static magnetic field B(0) . This paper describes the first realization of a multislice RF-CDI sequence on a 1.5 T clinical imager. Multislice RF current density images have been reconstructed for two phantoms. The influence of MRI random noise on the sensitivity of the multislice RF-CDI measurement has also been studied by theoretical analysis, simulation and phantom experiments.
journal_name
IEEE Trans Med Imagingjournal_title
IEEE transactions on medical imagingauthors
Wang D,DeMonte TP,Ma W,Joy ML,Nachman AIdoi
10.1109/TMI.2008.2012161subject
Has Abstractpub_date
2009-07-01 00:00:00pages
1083-92issue
7eissn
0278-0062issn
1558-254Xjournal_volume
28pub_type
杂志文章abstract::Following B.B. Mandelbrot's fractal theory (1982), it was found that the fractal dimension could be obtained in medical images by the concept of fractional Brownian motion. An estimation concept for determination of the fractal dimension based upon the concept of fractional Brownian motion is discussed. Two applicatio...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.24861
更新日期:1989-01-01 00:00:00
abstract::Inhomogeneities in the transmit radio frequency magnetic field ( ) reduce the quality of magnetic resonance (MR) images. This quality can be improved by using high-permittivity pads that tailor the fields. The design of an optimal pad is application-specific and not straightforward and would therefore benefit from a s...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2018.2791179
更新日期:2018-04-01 00:00:00
abstract::We describe a nonparametric framework for incorporating information from co-registered anatomical images into positron emission tomographic (PET) image reconstruction through priors based on information theoretic similarity measures. We compare and evaluate the use of mutual information (MI) and joint entropy (JE) bet...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2010.2076827
更新日期:2011-03-01 00:00:00
abstract::Building a data-driven model to localize the origin of ventricular activation from 12-lead electrocardiograms (ECG) requires addressing the challenge of large anatomical and physiological variations across individuals. The alternative of a patient-specific model is, however, difficult to implement in clinical practice...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2018.2880092
更新日期:2019-05-01 00:00:00
abstract::Magnetic resonance imaging (MRI) reconstruction techniques are often validated with signal-to-noise ratio (SNR), contrast-to-noise ratio, and mean-to-standard-deviation ratio measured on example images. We present human and model observers as a novel approach to evaluating reconstructions for low-SNR magnetic resonanc...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2006.881374
更新日期:2006-11-01 00:00:00
abstract::In standard B-mode ultrasound (BMUS), segmentation of the lumen of atherosclerotic carotid arteries and studying the lumen geometry over time are difficult owing to irregular lumen shapes, noise, artifacts, and echolucent plaques. Contrast enhanced ultrasound (CEUS) improves lumen visualization, but lumen segmentation...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2014.2372784
更新日期:2015-04-01 00:00:00
abstract::High peak RF amplitude and excessive specific absorption rate (SAR) are two critical concerns for hardware implementation and patient safety in scientific and clinical research for high field MRI using parallel transmissions (pTX). In this paper, we introduce a squeezing strategy to reduce peak RF amplitude and integr...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2018.2828112
更新日期:2018-08-01 00:00:00
abstract::High-resolution functional imaging of small animals is often obtained by single pinhole SPECT with circular orbit acquisition. Multipinhole SPECT adds information due to its improved sampling, and can improve the trade-off between resolution and sensitivity. To evaluate different pinhole collimator designs an efficien...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2007.902802
更新日期:2008-01-01 00:00:00
abstract::Ultra-short TE (UTE) sequences with radial sampling make it possible to visualize tissues with very short T2 decay times. The UTE sequence acquires an echo signal from the central to the outer parts of k-space and is very sensitive to small trajectory errors. Therefore, k-space errors caused by imperfections in the gr...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2012.2226050
更新日期:2013-02-01 00:00:00
abstract::In magnetic resonance imaging (MRI), spatial resolution is limited by several factors such as acquisition time, short physiological phenomena, and organ motion. The acquired image usually has higher resolution in two dimensions (the acquisition plane) in comparison with the third dimension, resulting in highly anisotr...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2014.2329271
更新日期:2014-10-01 00:00:00
abstract::With the widespread use of positron emission tomography (PET) crystals with greatly improved energy resolution (e.g., 11.5% with LYSO as compared to 20% with BGO) and of list-mode acquisitions, the use of the energy of individual events in scatter correction schemes becomes feasible. We propose a novel scatter approac...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2010.2095025
更新日期:2011-03-01 00:00:00
abstract::A preoperative planning system for oral implant surgery was developed which takes as input computed tomographies (CT's) of the jaws. Two-dimensional (2-D) reslices of these axial CT slices orthogonal to a curve following the jaw arch are computed and shown together with three-dimensional (3-D) surface rendered models ...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.736056
更新日期:1998-10-01 00:00:00
abstract::The solution of impedance distribution in electrical impedance tomography is a nonlinear inverse problem that requires the use of a regularization method. The generalized Tikhonov regularization methods have been popular in the solution of many inverse problems. The regularization matrices that are usually used with t...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.700740
更新日期:1998-04-01 00:00:00
abstract::In this paper, we are interested in soft tissue differentiation by multiband images obtained from the High-Resolution Ultrasonic Transmission Tomography (HUTT) system using a spectral target detection method based on constrained energy minimization (CEM). We have developed a new tissue differentiation method (called "...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/tmi.2004.843179
更新日期:2005-03-01 00:00:00
abstract::We present an integrated approach to probabilistic independent component analysis (ICA) for functional MRI (FMRI) data that allows for nonsquare mixing in the presence of Gaussian noise. In order to avoid overfitting, we employ objective estimation of the amount of Gaussian noise through Bayesian analysis of the true ...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2003.822821
更新日期:2004-02-01 00:00:00
abstract::Alzheimer's disease (AD) is a serious neurodegenerative condition that affects millions of individuals across the world. As the average age of individuals in the United States and the world increases, the prevalence of AD will continue to grow. To address this public health problem, the research community has develope...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2019.2958943
更新日期:2020-06-01 00:00:00
abstract::Image segmentation is the partition of an image into a set of nonoverlapping regions whose union is the entire image. The image is decomposed into meaningful parts which are uniform with respect to certain characteristics, such as gray level or texture. In this paper, we propose a methodology for evaluating medical im...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.640755
更新日期:1997-10-01 00:00:00
abstract::A true three-dimensional cone-beam reconstruction (TTCR) algorithm for direct volume image reconstruction from 2-D cone-beam projections is developed for the complete sphere geometry. The algorithm is derived from the parallel-beam true three-dimensional reconstruction (TTR) algorithm and is based on the modified filt...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.41483
更新日期:1989-01-01 00:00:00
abstract::In single photon emission computed tomography (SPECT), every reconstruction algorithm must use some model for the response of the gamma camera to emitted gamma-rays. The true camera response is both spatially variant and object dependent. These two properties result from the effects of scatter, septal penetration, and...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.126914
更新日期:1992-01-01 00:00:00
abstract::The expectation maximization method for maximum likelihood image reconstruction in emission tomography, based on the Poisson distribution of the statistically independent components of the image and measurement vectors, is extended to a maximum aposteriori image reconstruction using a multivariate Gaussian a priori pr...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.1987.4307826
更新日期:1987-01-01 00:00:00
abstract::We have developed a method to study the statistical properties of the noise found in various medical images. The method is specifically designed for types of noise with uncorrelated fluctuations. Such signal fluctuations generally originate in the physical processes of imaging rather than in the tissue textures. Vario...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2004.832656
更新日期:2004-10-01 00:00:00
abstract::Identification of objective criteria to correctly diagnose ectatic diseases of the cornea or to detect early stages of corneal ectasia is of great interest in ophthalmology and optometry. Metrics for diagnosis typically employed are curvature maps (axial/sagittal, tangential); elevation map of the anterior surface of ...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2018.2836304
更新日期:2018-11-01 00:00:00
abstract::Displacement estimated interframe (DEI) coding, a coding scheme for 3-D medical image data sets such as X-ray computed tomography (CT) or magnetic resonance (MR) images, is presented. To take advantage of the correlation between contiguous slices, a displacement-compensated difference image based on the previous image...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.241875
更新日期:1993-01-01 00:00:00
abstract::Blood oxygen level dependent (BOLD) functional magnetic resonance imaging (fMRI) is conventionally done by reconstructing T(2)(*)-weighted images. However, since the images are unitless they are nonquantifiable in terms of important physiological parameters. An alternative approach is to reconstruct R(2)(*) maps which...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2008.917247
更新日期:2008-09-01 00:00:00
abstract::Electrical conductivity and permittivity of biological tissues are important diagnostic parameters and are useful for calculating subject-specific specific absorption rate distribution. On the other hand, water proton density also has clinical relevance for diagnosis purposes. These two kinds of tissue properties are ...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2016.2547988
更新日期:2016-09-01 00:00:00
abstract::A method for detection and removal of random spike noise in magnetic resonance (MR) raw data (k-space data) is described. This method would reduce or eliminate the corduroy-type and higher than usual level artifacts in MR images resulting from random spike noise in k-space data. The method described involves applying ...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.276151
更新日期:1994-01-01 00:00:00
abstract::Magnetic resonance parameter mapping (e.g., T1 mapping, T2 mapping, T*2 mapping) is a valuable tool for tissue characterization. However, its practical utility has been limited due to long data acquisition time. This paper addresses this problem with a new model-based parameter mapping method. The proposed method util...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2014.2322815
更新日期:2014-09-01 00:00:00
abstract::Brain shift during open cranial surgery presents a challenge for maintaining registration with image-guidance systems. Ultrasound (US) is a convenient intraoperative imaging modality that may be a useful tool in detecting tissue shift and updating preoperative images based on intraoperative measurements of brain defor...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2003.819293
更新日期:2003-11-01 00:00:00
abstract::An analysis of the kinetics of myocardial contrast enhancement is an important component of myocardial perfusion studies. The contrast enhancement can be modeled by a linear time-invariant system, and the myocardial impulse response, calculated by deconvolution of the measured tissue response with an arterial input, g...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2004.827969
更新日期:2004-07-01 00:00:00
abstract::This paper introduces a computer-aided atlas-based functional neurosurgery methodology and describes NeuroPlanner, a software system which supports it. NeuroPlanner provides four groups of functions: 1) data-related for data reading, interpolation, reformatting, and image processing; 2) atlas-related for multiple atla...
journal_title:IEEE transactions on medical imaging
pub_type: 信件
doi:10.1109/42.832961
更新日期:2000-01-01 00:00:00