Abstract:
:High-resolution functional imaging of small animals is often obtained by single pinhole SPECT with circular orbit acquisition. Multipinhole SPECT adds information due to its improved sampling, and can improve the trade-off between resolution and sensitivity. To evaluate different pinhole collimator designs an efficient method is needed that quantifies the reconstruction image quality. In this paper, we propose a fast, approximate method that examines the quality of individual voxels of a postsmoothed maximum likelihood expectation maximization (MLEM) reconstruction by studying their linearized local impulse response (LLIR) and (co)variance for a predefined target resolution. For validation, the contrast-to-noise ratios (CNRs) in some voxels of a homogeneous sphere and of a realistic rat brain software phantom were calculated for many single and multipinhole designs. A good agreement was observed between the CNRs obtained with the approximate method and those obtained with postsmoothed MLEM reconstructions of simulated noisy projections. This good agreement was quantified by a least squares fit through these results, which yielded a line with slope 1.02 (1.00 expected) and a y-intercept close to zero (0 expected). 95.4% of the validation points lie within three standard deviations from that line. Using the approximate method, the influence on the CNR of varying a parameter in realistic single and multipinhole designs was examined. The investigated parameters were the aperture diameter, the distance between the apertures and the axis-of-rotation, the focal distance, the acceptance angle, the position of the apertures, the focusing distance, and the number of pinholes. The results can generally be explained by the change in sensitivity, the amount of postsmoothing, and the amount of overlap in the projections. The method was applied to multipinhole designs with apertures focusing at a single point, but is also applicable to other designs.
journal_name
IEEE Trans Med Imagingjournal_title
IEEE transactions on medical imagingauthors
Vunckx K,Beque D,Defrise M,Nuyts Jdoi
10.1109/TMI.2007.902802subject
Has Abstractpub_date
2008-01-01 00:00:00pages
36-46issue
1eissn
0278-0062issn
1558-254Xjournal_volume
27pub_type
杂志文章abstract::Magnetic resonance (MR) fingerprinting is a technique for acquiring and processing MR data that simultaneously provides quantitative maps of different tissue parameters through a pattern recognition algorithm. A predefined dictionary models the possible signal evolutions simulated using the Bloch equations with differ...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2014.2337321
更新日期:2014-12-01 00:00:00
abstract::We describe a fast forward and back projector pair based on inverse Fourier rebinning for use in iterative image reconstruction for fully three-dimensional (3-D) positron emission tomography (PET). The projector pair is used as part of a factored system matrix that takes into account detector-pair response by using sh...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:
更新日期:2007-03-01 00:00:00
abstract::A fully automated 2-D+time myocardial segmentation framework is proposed for cardiac magnetic resonance (CMR) blood-oxygen-level-dependent (BOLD) data sets. Ischemia detection with CINE BOLD CMR relies on spatio-temporal patterns in myocardial intensity, but these patterns also trouble supervised segmentation methods,...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2017.2726112
更新日期:2017-11-01 00:00:00
abstract::An electrical impedance tomography (EIT) system that uses the optimal current method to inject currents and the regularized Newton-Raphson algorithm to reconstruct an image of resistivity distribution is discussed. Iterative methods to derive the optimal current patterns through iterative physical measurements are dev...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.192684
更新日期:1992-01-01 00:00:00
abstract::The National Library of Medicine (NLM) is developing a digital chest X-ray (CXR) screening system for deployment in resource constrained communities and developing countries worldwide with a focus on early detection of tuberculosis. A critical component in the computer-aided diagnosis of digital CXRs is the automatic ...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2013.2290491
更新日期:2014-02-01 00:00:00
abstract::Intrinsic or data-driven respiratory and cardiac motion detection often track the center-of-mass (COM) change in PET data to derive a motion gating signal. The effectiveness of this method depends on the contrast of the moving target to the relatively stationary background. The stationary background leads to a reduced...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2015.2423976
更新日期:2015-10-01 00:00:00
abstract::Thin, dense interslice septa have long been used to reduce the scattered radiation collected in positron emission tomography (PET). These septa prevent the acquisition of coincident gamma rays that are oblique to the scanning planes. Several volume imaging systems that acquire oblique rays have been built. The reasons...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.222675
更新日期:1993-01-01 00:00:00
abstract::We present a general wavelet-based denoising scheme for functional magnetic resonance imaging (fMRI) data and compare it to Gaussian smoothing, the traditional denoising method used in fMRI analysis. One-dimensional WaveLab thresholding routines were adapted to two-dimensional (2-D) images, and applied to 2-D wavelet ...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2004.824234
更新日期:2004-03-01 00:00:00
abstract::In picture archiving and communications systems (PACS), images need to be displayed in standardized ways for radiologists' interpretations. However, for most radiographs acquired via computed radiography (CR), digital radiography (DR), or digitized films, the image orientation is undetermined because of the variations...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/tmi.2006.880677
更新日期:2006-10-01 00:00:00
abstract::Transmembrane voltage-sensitive fluorescent dyes are used to study electrical activity in hearts. Green and red fluorescence emissions from di-4-ANEPPS excited with 488 nm light indicate both transmembrane voltage changes and heart movement. We have previously shown that the ratio, green fluorescence divided by red fl...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2005.861019
更新日期:2006-01-01 00:00:00
abstract::A new class of acquisition schemes for helical cone-beam computed tomography (CB-CT) scanning is introduced, and their effect on the reconstruction methods is analyzed. These acquisition schemes are based on a new detector shape that is bounded by the helix. It will be shown that the data acquired with these schemes a...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.887834
更新日期:2000-09-01 00:00:00
abstract::This paper presents a novel image-guided robot-based system to assist orthopedic surgeons in performing distal locking of long bone intramedullary nails. The system consists of a bone-mounted miniature robot fitted with a drill guide that provides rigid mechanical guidance for hand-held drilling of the distal screws' ...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2005.844922
更新日期:2005-05-01 00:00:00
abstract::Given that heart disease can cause abnormal motion dynamics over the cardiac cycle, understanding and quantifying cardiac motion can provide insight for clinicians to aid with diagnosis, therapy planning, and determining prognosis. The goal of this paper is to extract population-specific motion patterns from 3D displa...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2015.2405579
更新日期:2015-07-01 00:00:00
abstract::Most strain imaging techniques follow a pipeline strategy: in the first step, tissue displacement is estimated from radio-frequency (RF) frames, and in the second step, a spatial derivative operation is applied. There are two main issues that arise from this framework. First, the gradient operation amplifies noise, an...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2017.2685522
更新日期:2017-06-01 00:00:00
abstract::The success of prostate brachytherapy critically depends on delivering adequate dose to the prostate gland. Intraoperative localization of the implanted seeds provides potential for dose evaluation and optimization during therapy. A reduced-dimensionality matching algorithm for prostate brachytherapy seed reconstructi...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2010.2059709
更新日期:2011-01-01 00:00:00
abstract::In this paper, we present a two-stage algorithm for mammogram registration, the geometrical alignment of mammogram sequences. The rationale behind this paper stems from the intrinsic difficulties in comparing mammogram sequences. Mammogram comparison is a valuable tool in national breast screening programs as well as ...
journal_title:IEEE transactions on medical imaging
pub_type: 临床试验,杂志文章
doi:10.1109/TMI.2005.848374
更新日期:2005-06-01 00:00:00
abstract::This paper presents a statistical shape model for the automatic prostate segmentation in transrectal ultrasound images. A Gabor filter bank is first used to characterize the prostate boundaries in ultrasound images in both multiple scales and multiple orientations. The Gabor features are further reconstructed to be in...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2003.809057
更新日期:2003-04-01 00:00:00
abstract::The solution of impedance distribution in electrical impedance tomography is a nonlinear inverse problem that requires the use of a regularization method. The generalized Tikhonov regularization methods have been popular in the solution of many inverse problems. The regularization matrices that are usually used with t...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.700740
更新日期:1998-04-01 00:00:00
abstract::Magnetic resonance imaging (MRI) on patients with implanted deep brain stimulators (DBSs) can be hazardous because of the antenna-effect of leads exposed to the incident radio-frequency field. This study evaluated electromagnetic field and specific absorption rate (SAR) changes as a function of lead resistivity on an ...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2010.2040624
更新日期:2010-04-01 00:00:00
abstract::The Bayesian ideal observer provides an absolute upper bound for diagnostic performance of an imaging system and hence should be used for the assessment of image quality whenever possible. However, computation of ideal-observer performance in clinical tasks is difficult since the probability density functions of the d...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2008.2008967
更新日期:2009-05-01 00:00:00
abstract::The watershed transform has interesting properties that make it useful for many different image segmentation applications: it is simple and intuitive, can be parallelized, and always produces a complete division of the image. However, when applied to medical image analysis, it has important drawbacks (oversegmentation...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2004.824224
更新日期:2004-04-01 00:00:00
abstract::A system for digital flashing tomosynthesis (DFTS) consists of four ECG-gated simultaneously flashed X-ray tubes, a 14-in image intensifier, a unit for digital subtraction angiography (DSA), a PC-hosted transputer network for three-dimensional (3-D) reconstruction as well as for quantitative coronary angiography and v...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.232261
更新日期:1993-01-01 00:00:00
abstract::Free-breathing cardiac diffusion tensor imaging (DTI) is a promising but challenging technique for the study of fiber structures of the human heart in vivo. This work proposes a clinically compatible and robust technique to provide three-dimensional (3-D) fiber architecture properties of the human heart. To this end, ...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2014.2356792
更新日期:2015-01-01 00:00:00
abstract::This paper presents a virtual tagging framework for measuring, as well as visualising, myocardial deformation using magnetic resonance (MR) velocity imaging. Tagging grids are allocated artificially according to the deformation gradient with varying shapes and densities. The control points are then deformed such that ...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2002.804429
更新日期:2002-09-01 00:00:00
abstract::The interpolation of missing spatial frequencies through the generalized auto-calibrating partially parallel acquisitions (GRAPPA) parallel magnetic resonance imaging (MRI) model implies a correlation is induced between the acquired and reconstructed frequency measurements. As the parallel image reconstruction algorit...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2013.2288521
更新日期:2014-02-01 00:00:00
abstract::Electrical conductivity and permittivity of biological tissues are important diagnostic parameters and are useful for calculating subject-specific specific absorption rate distribution. On the other hand, water proton density also has clinical relevance for diagnosis purposes. These two kinds of tissue properties are ...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2016.2547988
更新日期:2016-09-01 00:00:00
abstract::Ultrashort echo time imaging on clinical systems is still limited by the rather long radio frequency switching times achievable with standard front end concepts. In this contribution, an independent parallel receive-only system is interfaced to an unmodified clinical MRI system, enabling imaging of species with ultras...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2019.2924057
更新日期:2020-01-01 00:00:00
abstract::Three-dimensional (3-D) angiographic methods are gaining acceptance for evaluation of atherosclerotic disease. However, measurement of vessel stenosis from 3-D angiographic methods can be problematic due to limited image resolution and contrast. We present a method for reconstructing vessel surfaces from 3-D angiograp...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.974935
更新日期:2001-12-01 00:00:00
abstract::Visual estimation of coronary obstruction severity from angiograms suffers from poor inter- and intraobserver reproducibility and is often inaccurate. In spite of the widely recognized limitations of visual analysis, automated methods have not found widespread clinical use, in part because they too frequently fail to ...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.370412
更新日期:1995-01-01 00:00:00
abstract::Risk stratification (characterization) of tumors from radiology images can be more accurate and faster with computer-aided diagnosis (CAD) tools. Tumor characterization through such tools can also enable non-invasive cancer staging, prognosis, and foster personalized treatment planning as a part of precision medicine....
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2019.2894349
更新日期:2019-08-01 00:00:00