The n-PI-method for helical cone-beam CT.

Abstract:

:A new class of acquisition schemes for helical cone-beam computed tomography (CB-CT) scanning is introduced, and their effect on the reconstruction methods is analyzed. These acquisition schemes are based on a new detector shape that is bounded by the helix. It will be shown that the data acquired with these schemes are compatible with exact reconstruction methods, and the adaptation of exact reconstruction algorithms to the new acquisition geometry is described. At the same time, the so-called PI-sufficiency condition is fulfilled. Moreover, a good fit to the acquisition requirements of the various medical applications of cone-beam CT is achieved. In contrast to other helical cone-beam acquisition and reconstruction methods, the n-PI-method introduced in this publication allows for variable pitches of the acquisition helix. This additional feature will introduce a higher flexibility into the acquisition protocols of future medical cone-beam scanners. An approximative n-PI-filtered backprojection (n-PI-FBP) reconstruction method is presented and verified. It yields convincing image quality.

journal_name

IEEE Trans Med Imaging

authors

Proksa R,Köhler T,Grass M,Timmer J

doi

10.1109/42.887834

subject

Has Abstract

pub_date

2000-09-01 00:00:00

pages

848-63

issue

9

eissn

0278-0062

issn

1558-254X

journal_volume

19

pub_type

杂志文章
  • Axial resolution and the value of interpolating scan in multislice positron computed tomography.

    abstract::We have calculated the aperture function of a positron computed tomograph (PCT) with computer simulation, and evaluated the axial resolution of a multislice PCT, Positologica III, both theoretically and experimentally. The axial point spread function (PSF) was approximately a triangle at or near the center of the fiel...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.1985.4307692

    authors: Senda M,Yonekura Y,Tamaki N,Tanaka Y,Komori M,Minato K,Konishi J,Torizuka K

    更新日期:1985-01-01 00:00:00

  • Intensity-based image registration using robust correlation coefficients.

    abstract::The ordinary sample correlation coefficient is a popular similarity measure for aligning images from the same or similar modalities. However, this measure can be sensitive to the presence of "outlier" objects that appear in one image but not the other, such as surgical instruments, the patient table, etc., which can l...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2004.835313

    authors: Kim J,Fessler JA

    更新日期:2004-11-01 00:00:00

  • Estimating average growth trajectories in shape-space using kernel smoothing.

    abstract::In this paper, we show how a dense surface point distribution model of the human face can be computed and demonstrate the usefulness of the high-dimensional shape-space for expressing the shape changes associated with growth and aging. We show how average growth trajectories for the human face can be computed in the a...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2003.814784

    authors: Hutton TJ,Buxton BF,Hammond P,Potts HW

    更新日期:2003-06-01 00:00:00

  • Solving the Bloch equation with periodic excitation using harmonic balancing: application to Rabi modulated excitation.

    abstract::In waveform design for magnetic resonance applications, periodic continuous-wave excitation offers potential advantages that remain largely unexplored because of a lack of understanding of the Bloch equation with periodic continuous-wave excitations. Using harmonic balancing techniques the steady state solutions of th...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2015.2423313

    authors: Tahayori B,Johnston LA,Layton KJ,Farrell PM,Mareels IM

    更新日期:2015-10-01 00:00:00

  • Selection of a convolution function for Fourier inversion using gridding [computerised tomography application].

    abstract::In the technique known as gridding, the data samples are weighted for sampling density and convolved with a finite kernel, then resampled on a grid preparatory to a fast Fourier transform. The authors compare the artifact introduced into the image for various convolving functions of different sizes, including the Kais...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.97598

    authors: Jackson JI,Meyer CH,Nishimura DG,Macovski A

    更新日期:1991-01-01 00:00:00

  • EMS-Net: A Deep Learning Method for Autodetecting Epileptic Magnetoencephalography Spikes.

    abstract::Epilepsy is a neurological disorder characterized by sudden and unpredictable epileptic seizures, which incurs significant negative impacts on patients' physical, psychological and social health. A practical approach to assist with the clinical assessment and treatment planning for patients is to process magnetoenceph...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2019.2958699

    authors: Zheng L,Liao P,Luo S,Sheng J,Teng P,Luan G,Gao JH

    更新日期:2020-06-01 00:00:00

  • Prostate Cancer Detection Using Composite Impedance Metric.

    abstract::Prostate cancer (PCa) recurrences are often predicted by assessing the status of surgical margins (SM)- positive surgical margins (PSM) increase the chances of biochemical recurrence by 2-4 times which may lead to PCa recurrence. To this end, an electrical impedance acquisition system with a microendoscopic probe was ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2016.2578939

    authors: Khan S,Mahara A,Hyams ES,Schned AR,Halter RJ

    更新日期:2016-12-01 00:00:00

  • Reducing the effects of scattered photons in X-ray projection imaging.

    abstract::An iterative algorithm is introduced which can compute and subtract the scatter bias. It is assumed that the scatter-free image is spatially bounded and anything outside the boundary is the result of recorded scattered photons. This information and the fact that the scatter distribution does not have appreciable high-...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.20362

    authors: Fahimi H,Macovski A

    更新日期:1989-01-01 00:00:00

  • A fast iterated conditional modes algorithm for water-fat decomposition in MRI.

    abstract::Decomposition of water and fat in magnetic resonance imaging (MRI) is important for biomedical research and clinical applications. In this paper, we propose a two-phased approach for the three-point water-fat decomposition problem. Our contribution consists of two components: 1) a background-masked Markov random field...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2011.2125980

    authors: Huang F,Narayan S,Wilson D,Johnson D,Zhang GQ

    更新日期:2011-08-01 00:00:00

  • Unsupervised Domain Adaptation from Axial to Short-Axis Multi-Slice Cardiac MR Images by Incorporating Pretrained Task Networks.

    abstract::Anisotropic multi-slice Cardiac Magnetic Resonance (CMR) Images are conventionally acquired in patient-specific short-axis (SAX) orientation. In specific cardiovascular diseases that affect right ventricular (RV) morphology, acquisitions in standard axial (AX) orientation are preferred by some investigators, due to po...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2021.3052972

    authors: Koehler S,Hussain T,Blair Z,Huffaker T,Ritzmann F,Tandon A,Pickardt T,Sarikouch S,Sarikouch S,Latus H,Greil G,Wolf I,Engelhardt S

    更新日期:2021-01-20 00:00:00

  • Pubic arch detection in transrectal ultrasound guided prostate cancer therapy.

    abstract::New biopsy techniques, increased life expectancy, and prostate-specific antigen (PSA) screening have contributed to an increase in the reported incidence of prostate cancer. Among several treatment options available to the patients, transperineal prostate brachytherapy has emerged as a medically successful, cost-effec...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.736032

    authors: Pathak SD,Grimm PD,Chalana V,Kim Y

    更新日期:1998-10-01 00:00:00

  • A registration framework for the comparison of mammogram sequences.

    abstract::In this paper, we present a two-stage algorithm for mammogram registration, the geometrical alignment of mammogram sequences. The rationale behind this paper stems from the intrinsic difficulties in comparing mammogram sequences. Mammogram comparison is a valuable tool in national breast screening programs as well as ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 临床试验,杂志文章

    doi:10.1109/TMI.2005.848374

    authors: Marias K,Behrenbruch C,Parbhoo S,Seifalian A,Brady M

    更新日期:2005-06-01 00:00:00

  • Neuro-fuzzy systems for computer-aided myocardial viability assessment.

    abstract::This paper describes a multimodality framework for computer-aided myocardial viability assessment based on neuro-fuzzy techniques. The proposed approach distinguishes two main levels: the modality-independent inference level and the modality-dependent application level. This two-level distinction releases the hard con...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.974925

    authors: Behloul F,Lelieveldt BP,Boudraa A,Janier MF,Revel D,Reiber JH

    更新日期:2001-12-01 00:00:00

  • A methodology for evaluation of boundary detection algorithms on medical images.

    abstract::Image segmentation is the partition of an image into a set of nonoverlapping regions whose union is the entire image. The image is decomposed into meaningful parts which are uniform with respect to certain characteristics, such as gray level or texture. In this paper, we propose a methodology for evaluating medical im...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.640755

    authors: Chalana V,Kim Y

    更新日期:1997-10-01 00:00:00

  • Accuracy of the morphology enabled dipole inversion (MEDI) algorithm for quantitative susceptibility mapping in MRI.

    abstract::Determining the susceptibility distribution from the magnetic field measured in a magnetic resonance (MR) scanner is an ill-posed inverse problem, because of the presence of zeroes in the convolution kernel in the forward problem. An algorithm called morphology enabled dipole inversion (MEDI), which incorporates spati...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2011.2182523

    authors: Liu T,Xu W,Spincemaille P,Avestimehr AS,Wang Y

    更新日期:2012-03-01 00:00:00

  • Multi-channel microstrip transceiver arrays using harmonics for high field MR imaging in humans.

    abstract::Radio-frequency (RF) transceiver array design using primary and higher order harmonics for in vivo parallel magnetic resonance imaging imaging (MRI) and spectroscopic imaging is proposed. The improved electromagnetic decoupling performance, unique magnetic field distributions and high-frequency operation capabilities ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2011.2166273

    authors: Wu B,Wang C,Lu J,Pang Y,Nelson SJ,Vigneron DB,Zhang X

    更新日期:2012-02-01 00:00:00

  • Brachytherapy seed localization using geometric and linear programming techniques.

    abstract::We propose an optimization algorithm to solve the brachytherapy seed localization problem in prostate brachytherapy. Our algorithm is based on novel geometric approaches to exploit the special structure of the problem and relies on a number of key observations which help us formulate the optimization problem as a mini...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2007.900740

    authors: Singh V,Mukherjee L,Xu J,Hoffmann KR,Dinu PM,Podgorsak M

    更新日期:2007-09-01 00:00:00

  • Breast tissue density quantification via digitized mammograms.

    abstract::Studies reported in the literature indicate that breast cancer risk is associated with mammographic densities. An objective, repeatable, and a quantitative measure of risk derived from mammographic densities will be of considerable use in recommending alternative screening paradigms and/or preventive measures. However...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.938247

    authors: Saha PK,Udupa JK,Conant EF,Chakraborty DP,Sullivan D

    更新日期:2001-08-01 00:00:00

  • Neuron Segmentation With High-Level Biological Priors.

    abstract::We present a novel approach to the problem of neuron segmentation in image volumes acquired by an electron microscopy. Existing methods, such as agglomerative or correlation clustering, rely solely on boundary evidence and have problems where such an evidence is lacking (e.g., incomplete staining) or ambiguous (e.g., ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2017.2712360

    authors: Krasowski NE,Beier T,Knott GW,Kothe U,Hamprecht FA,Kreshuk A

    更新日期:2018-04-01 00:00:00

  • Interactive CT-video registration for the continuous guidance of bronchoscopy.

    abstract::Bronchoscopy is a major step in lung cancer staging. To perform bronchoscopy, the physician uses a procedure plan, derived from a patient's 3D computed-tomography (CT) chest scan, to navigate the bronchoscope through the lung airways. Unfortunately, physicians vary greatly in their ability to perform bronchoscopy. As ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2013.2252361

    authors: Merritt SA,Khare R,Bascom R,Higgins WE

    更新日期:2013-08-01 00:00:00

  • Sufficient statistics as a generalization of binning in spectral X-ray imaging.

    abstract::It is well known that the energy dependence of X-ray attenuation can be used to characterize materials. Yet, even with energy discriminating photon counting X-ray detectors, it is still unclear how to best form energy dependent measurements for spectral imaging. Common ideas include binning photon counts based on thei...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2010.2061862

    authors: Wang AS,Pelc NJ

    更新日期:2011-01-01 00:00:00

  • A Signal Acquisition Setup for Ultrashort Echo Time Imaging Operating in Parallel on Unmodified Clinical MRI Scanners Achieving an Acquisition Delay of [Formula: see text].

    abstract::Ultrashort echo time imaging on clinical systems is still limited by the rather long radio frequency switching times achievable with standard front end concepts. In this contribution, an independent parallel receive-only system is interfaced to an unmodified clinical MRI system, enabling imaging of species with ultras...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2019.2924057

    authors: Eder M,Horneff A,Paul J,Storm A,Wunderlich A,Hell E,Ulrici J,Anders J,Rasche V

    更新日期:2020-01-01 00:00:00

  • MITT: Medical Image Tracking Toolbox.

    abstract::Over the years, medical image tracking has gained considerable attention from both medical and research communities due to its widespread utility in a multitude of clinical applications, from functional assessment during diagnosis and therapy planning to structure tracking or image fusion during image-guided intervent...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2018.2840820

    authors: Queiros S,Morais P,Barbosa D,Fonseca JC,Vilaca JL,D'Hooge J

    更新日期:2018-11-01 00:00:00

  • Computation of the mid-sagittal plane in 3-D brain images.

    abstract::We present a new method to automatically compute, reorient, and recenter the mid-sagittal plane in anatomical and functional three-dimensional (3-D) brain images. This iterative approach is composed of two steps. At first, given an initial guess of the mid-sagittal plane (generally, the central plane of the image grid...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.993131

    authors: Prima S,Ourselin S,Ayache N

    更新日期:2002-02-01 00:00:00

  • Automatic Stem Cell Detection in Microscopic Whole Mouse Cryo-Imaging.

    abstract::With its single cell sensitivity over volumes as large as or larger than a mouse, cryo-imaging enables imaging of stem cell biodistribution, homing, engraftment, and molecular mechanisms. We developed and evaluated a highly automated software tool to detect fluorescently labeled stem cells within very large ( ∼ 200 GB...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2015.2497285

    authors: Wuttisarnwattana P,Gargesha M,van't Hof W,Cooke KR,Wilson DL

    更新日期:2016-03-01 00:00:00

  • Tomographic fluorescence imaging in tissue phantoms: a novel reconstruction algorithm and imaging geometry.

    abstract::A novel image reconstruction algorithm has been developed and demonstrated for fluorescence-enhanced frequency-domain photon migration (FDPM) tomography from measurements of area illumination with modulated excitation light and area collection of emitted fluorescence light using a gain modulated image-intensified char...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/tmi.2004.839359

    authors: Roy R,Thompson AB,Godavarty A,Sevick-Muraca EM

    更新日期:2005-02-01 00:00:00

  • A Magnetic Resonance Imaging Surface Coil Transceiver Employing a Metasurface for 1.5T Applications.

    abstract::A capacitive impedance metasurface combined with a transceiver coil to improve the radio frequency magnetic field for 1.5T magnetic resonance imaging applications is presented. The novel transceiver provides localized enhancement in magnetic flux density when compared to a transceiver coil alone by incorporating an el...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2019.2942194

    authors: Issa I,Ford KL,Rao M,Wild JM

    更新日期:2020-04-01 00:00:00

  • Experimental evaluation of two iterative reconstruction methods for induced current electrical impedance tomography.

    abstract::The Newton-Raphson (N-R) with two different regularization methods: the Levenberg-Marquardt (N-R-LM) and the Hachtel's Augmented Matrix (N-R-HAM), were used to reconstruct images of conductivity changes in a cylindrical medium by Induced Current Electrical Impedance Tomography (ic-EIT). Experimental data were obtained...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.491419

    authors: Ruan W,Guardo R,Adler A

    更新日期:1996-01-01 00:00:00

  • The GEM MAP algorithm with 3-D SPECT system response.

    abstract::In single photon emission computed tomography (SPECT), every reconstruction algorithm must use some model for the response of the gamma camera to emitted gamma-rays. The true camera response is both spatially variant and object dependent. These two properties result from the effects of scatter, septal penetration, and...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.126914

    authors: Hebert TJ,Gopal SS

    更新日期:1992-01-01 00:00:00

  • Hot spot detection based on feature space representation of visual search.

    abstract::This paper presents a new framework for capturing intrinsic visual search behavior of different observers in image understanding by analysing saccadic eye movements in feature space. The method is based on the information theory for identifying salient image features based on which visual search is performed. We demon...

    journal_title:IEEE transactions on medical imaging

    pub_type: 临床试验,杂志文章

    doi:10.1109/TMI.2003.816959

    authors: Hu XP,Dempere-Marco L,Yang GZ

    更新日期:2003-09-01 00:00:00