Spatio-Temporal Tensor Decomposition of a Polyaffine Motion Model for a Better Analysis of Pathological Left Ventricular Dynamics.

Abstract:

:Given that heart disease can cause abnormal motion dynamics over the cardiac cycle, understanding and quantifying cardiac motion can provide insight for clinicians to aid with diagnosis, therapy planning, and determining prognosis. The goal of this paper is to extract population-specific motion patterns from 3D displacements in order to identify the mean motion in a population, and to describe pathology-specific motion patterns in terms of the spatial and temporal components. Since there are common motion patterns observed in patients with the same condition, extracting these can lead towards a better understanding of the disease. Quantifying cardiac motion at a population level is not a simple task since images can vary widely in terms of image quality, size, resolution, and pose. To overcome this, we analyze the parameters obtained from a cardiac-specific Polyaffine motion-tracking algorithm, which are aligned both spatially and temporally to a common reference space. Once all parameters are aligned, different subjects can be compared and analyzed in the space of Polyaffine transformations by projecting the transformations to a reduced order subspace in which dominant motion patterns in each population can be extracted. Using tensor decomposition, the spatial and temporal aspects can be decoupled in order to study the components individually. The proposed method was validated on healthy volunteers and Tetralogy of Fallot patients according to known spatial and temporal behavior for each population. A key advantage of this method is the ability to regenerate motion sequences from the models, which can be visualized in terms of the full motion.

journal_name

IEEE Trans Med Imaging

authors

McLeod K,Sermesant M,Beerbaum P,Pennec X

doi

10.1109/TMI.2015.2405579

subject

Has Abstract

pub_date

2015-07-01 00:00:00

pages

1562-1575

issue

7

eissn

0278-0062

issn

1558-254X

journal_volume

34

pub_type

杂志文章
  • Unsupervised MR-to-CT Synthesis Using Structure-Constrained CycleGAN.

    abstract::Synthesizing a CT image from an available MR image has recently emerged as a key goal in radiotherapy treatment planning for cancer patients. CycleGANs have achieved promising results on unsupervised MR-to-CT image synthesis; however, because they have no direct constraints between input and synthetic images, cycleGAN...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2020.3015379

    authors: Yang H,Sun J,Carass A,Zhao C,Lee J,Prince JL,Xu Z

    更新日期:2020-12-01 00:00:00

  • In Vivo Measurement of Brain Tissue Response After Irradiation: Comparison of T2 Relaxation, Apparent Diffusion Coefficient, and Electrical Conductivity.

    abstract::Radiation therapy (RT) has been widely used as a powerful treatment tool to address cancerous tissues because of its ability to control cell growth. Its ionizing radiation damages the DNA of cancerous tissues, leading to cell death. Medical imaging, however, still has limitations regarding the reliability of its asses...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2019.2913766

    authors: Park JA,Kang KJ,Ko IO,Lee KC,Choi BK,Katoch N,Kim JW,Kim HJ,Kwon OI,Woo EJ

    更新日期:2019-12-01 00:00:00

  • A filtered backprojection algorithm for triple-source helical cone-beam CT.

    abstract::Multisource cone-beam computed tomography (CT) is an attractive approach of choice for superior temporal resolution, which is critically important for cardiac imaging and contrast enhanced studies. In this paper, we present a filtered-backprojection (FBP) algorithm for triple-source helical cone-beam CT. The algorithm...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2008.2004817

    authors: Zhao J,Jin Y,Lu Y,Wang G

    更新日期:2009-03-01 00:00:00

  • Quantification of Wave Reflection in the Human Umbilical Artery From Asynchronous Doppler Ultrasound Measurements.

    abstract::Elevated umbilical artery pulsatility is a widely used biomarker for placental pathology leading to intra-uterine growth restriction and, in severe cases, still-birth. It has been hypothesized that placental pathology modifies umbilical artery pulsatility by altering the degree to which the pulse pressure wave, which ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2020.3004511

    authors: Stortz G,Cahill LS,Chandran AR,Baschat A,Sled JG,Macgowan CK

    更新日期:2020-11-01 00:00:00

  • Experimental evaluation of two iterative reconstruction methods for induced current electrical impedance tomography.

    abstract::The Newton-Raphson (N-R) with two different regularization methods: the Levenberg-Marquardt (N-R-LM) and the Hachtel's Augmented Matrix (N-R-HAM), were used to reconstruct images of conductivity changes in a cylindrical medium by Induced Current Electrical Impedance Tomography (ic-EIT). Experimental data were obtained...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.491419

    authors: Ruan W,Guardo R,Adler A

    更新日期:1996-01-01 00:00:00

  • Multi-scale tubular structure detection in ultrasound imaging.

    abstract::We propose a novel, physics-based method for detecting multi-scale tubular features in ultrasound images. The detector is based on a Hessian-matrix eigenvalue method, but unlike previous work, our detector is guided by an optimal model of vessel-like structures with respect to the ultrasound-image formation process. O...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2014.2340912

    authors: Hennersperger C,Baust M,Waelkens P,Karamalis A,Ahmadi SA,Navab N

    更新日期:2015-01-01 00:00:00

  • Restoration of retinal images obtained through cataracts.

    abstract::An optical model for imaging the retina through cataracts has been developed. The images are treated as sample functions of stochastic processes. On the basis of the model a homomorphic Weiner filter can be designed that will optimally restore the cataractous image (in the mean-square-error sense). The design of the f...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.41493

    authors: Peli E,Peli T

    更新日期:1989-01-01 00:00:00

  • 3D Statistical Shape Models Incorporating Landmark-Wise Random Regression Forests for Omni-Directional Landmark Detection.

    abstract::3D Statistical Shape Models (3D-SSM) are widely used for medical image segmentation. However, during segmentation, they typically perform a very limited unidirectional search for suitable landmark positions in the image, relying on weak learners or use-case specific appearance models that solely take local image infor...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2016.2600502

    authors: Norajitra T,Maier-Hein KH

    更新日期:2017-01-01 00:00:00

  • Accelerated Parameter Mapping of Multiple-Echo Gradient-Echo Data Using Model-Based Iterative Reconstruction.

    abstract::A new reconstruction method, coined MIRAGE, is presented for accurate, fast, and robust parameter mapping of multiple-echo gradient-echo (MEGE) imaging, the basis sequence of novel quantitative magnetic resonance imaging techniques such as water content and susceptibility mapping. Assuming that the temporal signal can...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2017.2771504

    authors: Zimmermann M,Abbas Z,Dzieciol K,Shah NJ

    更新日期:2018-02-01 00:00:00

  • Artificial Neural Network Enhanced Bayesian PET Image Reconstruction.

    abstract::In positron emission tomography (PET) image reconstruction, the Bayesian framework with various regularization terms has been implemented to constrain the radio tracer distribution. Varying the regularizing weight of a maximum a posteriori (MAP) algorithm specifies a lower bound of the tradeoff between variance and sp...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2018.2803681

    authors: Yang B,Ying L,Tang J

    更新日期:2018-06-01 00:00:00

  • Strain Energy Decay Predicts Elastic Registration Accuracy from Intraoperative Data Constraints.

    abstract::Image-guided intervention for soft tissue organs depends on the accuracy of deformable registration methods to achieve effective results. While registration techniques based on elastic theory are prevalent, no methods yet exist that can prospectively estimate registration uncertainty to regulate sources and mitigate c...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2021.3052523

    authors: Heiselman JS,Miga MI

    更新日期:2021-01-18 00:00:00

  • Gaussian process models of dynamic PET for functional volume definition in radiation oncology.

    abstract::In routine oncologic positron emission tomography (PET), dynamic information is discarded by time-averaging the signal to produce static images of the "standardised uptake value" (SUV). Defining functional volumes of interest (VOIs) in terms of SUV is flawed, as values are affected by confounding factors and the chose...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2012.2193896

    authors: Shepherd T,Owenius R

    更新日期:2012-08-01 00:00:00

  • Advanced level-set-based cell tracking in time-lapse fluorescence microscopy.

    abstract::Cell segmentation and tracking in time-lapse fluorescence microscopy images is a task of fundamental importance in many biological studies on cell migration and proliferation. In recent years, level sets have been shown to provide a very appropriate framework for this purpose, as they are well suited to capture topolo...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2009.2038693

    authors: Dzyubachyk O,van Cappellen WA,Essers J,Niessen WJ,Meijering E

    更新日期:2010-03-01 00:00:00

  • MRI Meets MPI: a bimodal MPI-MRI tomograph.

    abstract::While magnetic particle imaging (MPI) constitutes a novel biomedical imaging technique for tracking superparamagnetic nanoparticles in vivo, unlike magnetic resonance imaging (MRI), it cannot provide anatomical background information. Until now these two modalities have been performed in separate scanners and image co...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2014.2327515

    authors: Vogel P,Lother S,Rückert MA,Kullmann WH,Jakob PM,Fidler F,Behr VC

    更新日期:2014-10-01 00:00:00

  • Local phase tensor features for 3-D ultrasound to statistical shape+pose spine model registration.

    abstract::Most conventional spine interventions are performed under X-ray fluoroscopy guidance. In recent years, there has been a growing interest to develop nonionizing imaging alternatives to guide these procedures. Ultrasound guidance has emerged as a leading alternative. However, a challenging problem is automatic identific...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2014.2332571

    authors: Hacihaliloglu I,Rasoulian A,Rohling RN,Abolmaesumi P

    更新日期:2014-11-01 00:00:00

  • Three-dimensional microwave breast imaging: dispersive dielectric properties estimation using patient-specific basis functions.

    abstract::Breast imaging via microwave tomography involves estimating the distribution of dielectric properties within the patient's breast on a discrete mesh. The number of unknowns in the discrete mesh can be very large for 3-D imaging, and this results in computational challenges. We propose a new approach where the discrete...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2008.2008959

    authors: Winters DW,Shea JD,Kosmas P,Van Veen BD,Hagness SC

    更新日期:2009-07-01 00:00:00

  • Standing-wave and RF penetration artifacts caused by elliptic geometry: an electrodynamic analysis of MRI.

    abstract::Motivated by the observation that the diagonal pattern of intensity nonuniformity usually associated with linearly polarized radio-frequency (RF) coils is often present in neurological scans using circularly polarized coils, a theoretical analysis has been conducted of the intensity nonuniformity inherent in imaging a...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.730409

    authors: Sled JG,Pike GB

    更新日期:1998-08-01 00:00:00

  • Sufficient statistics as a generalization of binning in spectral X-ray imaging.

    abstract::It is well known that the energy dependence of X-ray attenuation can be used to characterize materials. Yet, even with energy discriminating photon counting X-ray detectors, it is still unclear how to best form energy dependent measurements for spectral imaging. Common ideas include binning photon counts based on thei...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2010.2061862

    authors: Wang AS,Pelc NJ

    更新日期:2011-01-01 00:00:00

  • Digital flashing tomosynthesis: a promising technique for angiocardiographic screening.

    abstract::A system for digital flashing tomosynthesis (DFTS) consists of four ECG-gated simultaneously flashed X-ray tubes, a 14-in image intensifier, a unit for digital subtraction angiography (DSA), a PC-hosted transputer network for three-dimensional (3-D) reconstruction as well as for quantitative coronary angiography and v...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.232261

    authors: Stiel GM,Stiel LG,Klotz E,Nienaber CA

    更新日期:1993-01-01 00:00:00

  • Dual Energy Differential Phase Contrast CT (DE-DPC-CT) Imaging.

    abstract::When more than two elemental materials are present in a given object, material quantification may not be robust and accurate when the routine two-material decomposition scheme in current dual energy CT imaging is employed. In this work, we present an innovative scheme to accomplish accurate three-material decompositio...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2020.2990347

    authors: Ji X,Zhang R,Li K,Chen GH

    更新日期:2020-11-01 00:00:00

  • Magnetic resonance angiography.

    abstract::This paper describes several methods for magnetic resonance angiography that create projection images based solely on flowing blood. To both remove static tissue from the image and generate signals from blood, two classes of methods considered are temporal subtraction and cancelling excitation. Temporal subtraction, a...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.1986.4307763

    authors: Nishimura DG,Macovski A,Pauly JM

    更新日期:1986-01-01 00:00:00

  • Retinal vessel centerline extraction using multiscale matched filters, confidence and edge measures.

    abstract::Motivated by the goals of improving detection of low-contrast and narrow vessels and eliminating false detections at nonvascular structures, a new technique is presented for extracting vessels in retinal images. The core of the technique is a new likelihood ratio test that combines matched-filter responses, confidence...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/tmi.2006.884190

    authors: Sofka M,Stewart CV

    更新日期:2006-12-01 00:00:00

  • A "twisting and bending" model-based nonrigid image registration technique for 3-D ultrasound carotid images.

    abstract::Atherosclerosis at the carotid bifurcation resulting in cerebral emboli is a major cause of ischemic stroke. Most strokes associated with carotid atherosclerosis can be prevented by lifestyle/dietary changes and pharmacological treatments if identified early by monitoring carotid plaque changes. Registration of 3-D ul...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2008.918326

    authors: Nanayakkara ND,Chiu B,Samani A,Spence JD,Samarabandu J,Fenster A

    更新日期:2008-10-01 00:00:00

  • Noninvasive mapping of transmural potentials during activation in swine hearts from body surface electrocardiograms.

    abstract::The three-dimensional cardiac electrical imaging (3DCEI) technique was previously developed to estimate the initiation site(s) of cardiac activation and activation sequence from the noninvasively measured body surface potential maps (BSPMs). The aim of this study was to develop and evaluate the capability of 3DCEI in ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2012.2202914

    authors: Liu C,Eggen MD,Swingen CM,Iaizzo PA,He B

    更新日期:2012-09-01 00:00:00

  • Lung and Pancreatic Tumor Characterization in the Deep Learning Era: Novel Supervised and Unsupervised Learning Approaches.

    abstract::Risk stratification (characterization) of tumors from radiology images can be more accurate and faster with computer-aided diagnosis (CAD) tools. Tumor characterization through such tools can also enable non-invasive cancer staging, prognosis, and foster personalized treatment planning as a part of precision medicine....

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2019.2894349

    authors: Hussein S,Kandel P,Bolan CW,Wallace MB,Bagci U

    更新日期:2019-08-01 00:00:00

  • Pinhole SPECT imaging: compact projection/backprojection operator for efficient algebraic reconstruction.

    abstract::We describe the efficient algebraic reconstruction (EAR) method, which applies to cone-beam tomographic reconstruction problems with a circular symmetry. Three independant steps/stages are presented, which use two symmetries and a factorization of the point spread functions (PSFs), each reducing computing times and ev...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2005.861707

    authors: Israel-Jost V,Choquet P,Salmon S,Blondet C,Sonnendrücker E,Constantinesco A

    更新日期:2006-02-01 00:00:00

  • Segmentation of cardiac cine MR images for extraction of right and left ventricular chambers.

    abstract::A two-stage algorithm for extraction of the ventricular chambers (endocardial surfaces) in flow-enhanced magnetic resonance images is described. In the first stage, the approximate locations and sizes of the endocardial surfaces are determined by intensity thresholding. In the second stage, points on each approximated...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.370402

    authors: Goshtasby A,Turner DA

    更新日期:1995-01-01 00:00:00

  • Narrowband magnetic particle imaging.

    abstract::The magnetic particle imaging (MPI) method directly images the magnetization of super-paramagnetic iron oxide (SPIO) nanoparticles, which are contrast agents commonly used in magnetic resonance imaging (MRI). MPI, as originally envisioned, requires a high-bandwidth receiver coil and preamplifier, which are difficult t...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2009.2013849

    authors: Goodwill PW,Scott GC,Stang PP,Conolly SM

    更新日期:2009-08-01 00:00:00

  • Self-Supervised Ultrasound to MRI Fetal Brain Image Synthesis.

    abstract::Fetal brain magnetic resonance imaging (MRI) offers exquisite images of the developing brain but is not suitable for second-trimester anomaly screening, for which ultrasound (US) is employed. Although expert sonographers are adept at reading US images, MR images which closely resemble anatomical images are much easier...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2020.3018560

    authors: Jiao J,Namburete AIL,Papageorghiou AT,Noble JA

    更新日期:2020-12-01 00:00:00

  • Simultaneous Estimation of Corneal Topography, Pachymetry, and Curvature.

    abstract::Identification of objective criteria to correctly diagnose ectatic diseases of the cornea or to detect early stages of corneal ectasia is of great interest in ophthalmology and optometry. Metrics for diagnosis typically employed are curvature maps (axial/sagittal, tangential); elevation map of the anterior surface of ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2018.2836304

    authors: Nasrin F,Iyer RV,Mathews SM

    更新日期:2018-11-01 00:00:00