Segmentation of cardiac cine MR images for extraction of right and left ventricular chambers.

Abstract:

:A two-stage algorithm for extraction of the ventricular chambers (endocardial surfaces) in flow-enhanced magnetic resonance images is described. In the first stage, the approximate locations and sizes of the endocardial surfaces are determined by intensity thresholding. In the second stage, points on each approximated surface are repositioned to nearest locally maximum gradient magnitude points and a generalized cylinder is fitted to them. Examples of ventricular chambers in cine MR images determined by this algorithm are presented.

journal_name

IEEE Trans Med Imaging

authors

Goshtasby A,Turner DA

doi

10.1109/42.370402

subject

Has Abstract

pub_date

1995-01-01 00:00:00

pages

56-64

issue

1

eissn

0278-0062

issn

1558-254X

journal_volume

14

pub_type

杂志文章
  • Co-registration of white matter tractographies by adaptive-mean-shift and Gaussian mixture modeling.

    abstract::In this paper, we present a robust approach to the registration of white matter tractographies extracted from diffusion tensor-magnetic resonance imaging scans. The fibers are projected into a high dimensional feature space based on the sequence of their 3-D coordinates. Adaptive mean-shift clustering is applied to ex...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2009.2029097

    authors: Zvitia O,Mayer A,Shadmi R,Miron S,Greenspan HK

    更新日期:2010-01-01 00:00:00

  • Optimization of MRI Gradient Coils With Explicit Peripheral Nerve Stimulation Constraints.

    abstract::Peripheral Nerve Stimulation (PNS) limits the acquisition rate of Magnetic Resonance Imaging data for fast sequences employing powerful gradient systems. The PNS characteristics are currently assessed after the coil design phase in experimental stimulation studies using constructed coil prototypes. This makes it diffi...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2020.3023329

    authors: Davids M,Guerin B,Klein V,Wald LL

    更新日期:2021-01-01 00:00:00

  • Compensation for nonuniform resolution using penalized-likelihood reconstruction in space-variant imaging systems.

    abstract::Imaging systems that form estimates using a statistical approach generally yield images with nonuniform resolution properties. That is, the reconstructed images possess resolution properties marked by space-variant and/or anisotropic responses. We have previously developed a space-variant penalty for penalized-likelih...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2003.823063

    authors: Stayman JW,Fessler JA

    更新日期:2004-03-01 00:00:00

  • Efficient fully 3-D iterative SPECT reconstruction with Monte Carlo-based scatter compensation.

    abstract::Quantitative accuracy of single photon emission computed tomography (SPECT) images is highly dependent on the photon scatter model used for image reconstruction. Monte Carlo simulation (MCS) is the most general method for detailed modeling of scatter, but to date, fully three-dimensional (3-D) MCS-based statistical SP...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2002.803130

    authors: Beekman FJ,de Jong HW,van Geloven S

    更新日期:2002-08-01 00:00:00

  • Segmentation of rodent whole-body dynamic PET images: an unsupervised method based on voxel dynamics.

    abstract::Positron emission tomography (PET) is a useful tool for pharmacokinetics studies in rodents during the preclinical phase of drug and tracer development. However, rodent organs are small as compared to the scanner's intrinsic resolution and are affected by physiological movements. We present a new method for the segmen...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2007.905106

    authors: Maroy R,Boisgard R,Comtat C,Frouin V,Cathier P,Duchesnay E,Dollé F,Nielsen PE,Trébossen R,Tavitian B

    更新日期:2008-03-01 00:00:00

  • A geometry-driven optical flow warping for spatial normalization of cortical surfaces.

    abstract::Spatial normalization is frequently used to map data to a standard coordinate system by removing intersubject morphological differences, thereby allowing for group analysis to be carried out. The work presented in this paper is motivated by the need for an automated cortical surface normalization technique that will a...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2008.925080

    authors: Tosun D,Prince JL

    更新日期:2008-12-01 00:00:00

  • Bidirectional Mapping-Based Domain Adaptation for Nucleus Detection in Cross-Modality Microscopy Images.

    abstract::Cell or nucleus detection is a fundamental task in microscopy image analysis and has recently achieved state-of-the-art performance by using deep neural networks. However, training supervised deep models such as convolutional neural networks (CNNs) usually requires sufficient annotated image data, which is prohibitive...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2020.3042789

    authors: Xing F,Cornish TC,Bennett TD,Ghosh D

    更新日期:2020-12-07 00:00:00

  • Quantifying the statistical impact of GRAPPA in fcMRI data with a real-valued isomorphism.

    abstract::The interpolation of missing spatial frequencies through the generalized auto-calibrating partially parallel acquisitions (GRAPPA) parallel magnetic resonance imaging (MRI) model implies a correlation is induced between the acquired and reconstructed frequency measurements. As the parallel image reconstruction algorit...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2013.2288521

    authors: Bruce IP,Rowe DB

    更新日期:2014-02-01 00:00:00

  • Spatial-resolution enhancement in computed tomography.

    abstract::We propose an approach that combines an asymmetric fan-beam configuration and a new reconstruction algorithm to enhancing spatial resolution in computed tomography (CT). The asymmetric configuration can be achieved by changing the center of rotation (COR) from the conventional symmetric configuration. It does not, how...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/tmi.2004.840846

    authors: Pan X,Yu L,Kao CM

    更新日期:2005-02-01 00:00:00

  • Development of a Mechanical Scanning Device With High-Frequency Ultrasound Transducer for Ultrasonic Capsule Endoscopy.

    abstract::Wireless capsule endoscopy has opened a new era by enabling remote diagnostic assessment of the gastrointestinal tract in a painless procedure. Video capsule endoscopy is currently commercially available worldwide. However, it is limited to visualization of superficial tissue. Ultrasound (US) imaging is a complementar...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2017.2699973

    authors: Wang X,Seetohul V,Chen R,Zhang Z,Qian M,Shi Z,Yang G,Mu P,Wang C,Huang Z,Zhou Q,Zheng H,Cochran S,Qiu W

    更新日期:2017-09-01 00:00:00

  • Semi-automatic segmentation of vascular network images using a rotating structuring element (ROSE) with mathematical morphology and dual feature thresholding.

    abstract::A method for measuring the spatial concentration of specific categories of vessels in a vascular network consisting of vessels of several diameters, lengths, and orientations is demonstrated. It is shown that a combination of the mathematical morphology operation, opening, with a linear rotating structuring element (R...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.241865

    authors: Thackray BD,Nelson AC

    更新日期:1993-01-01 00:00:00

  • SVD compression for magnetic resonance fingerprinting in the time domain.

    abstract::Magnetic resonance (MR) fingerprinting is a technique for acquiring and processing MR data that simultaneously provides quantitative maps of different tissue parameters through a pattern recognition algorithm. A predefined dictionary models the possible signal evolutions simulated using the Bloch equations with differ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2014.2337321

    authors: McGivney DF,Pierre E,Ma D,Jiang Y,Saybasili H,Gulani V,Griswold MA

    更新日期:2014-12-01 00:00:00

  • Blind color decomposition of histological images.

    abstract::Cancer diagnosis is based on visual examination under a microscope of tissue sections from biopsies. But whereas pathologists rely on tissue stains to identify morphological features, automated tissue recognition using color is fraught with problems that stem from image intensity variations due to variations in tissue...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2013.2239655

    authors: Gavrilovic M,Azar JC,Lindblad J,Wahlby C,Bengtsson E,Busch C,Carlbom IB

    更新日期:2013-06-01 00:00:00

  • Multimodal registration and data fusion for cardiac resynchronization therapy optimization.

    abstract::Cardiac resynchronization therapy (CRT) has been shown to improve cardiovascular function in specific patients suffering from heart failure. This procedure still needs to be optimized to overcome the high rate of implanted patients that do not respond to this therapy. We propose in this work a better characterization ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2014.2311694

    authors: Tavard F,Simon A,Leclercq C,Donal E,Hernández AI,Garreau M

    更新日期:2014-06-01 00:00:00

  • Robust super-resolution volume reconstruction from slice acquisitions: application to fetal brain MRI.

    abstract::Fast magnetic resonance imaging slice acquisition techniques such as single shot fast spin echo are routinely used in the presence of uncontrollable motion. These techniques are widely used for fetal magnetic resonance imaging (MRI) and MRI of moving subjects and organs. Although high-quality slices are frequently acq...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2010.2051680

    authors: Gholipour A,Estroff JA,Warfield SK

    更新日期:2010-10-01 00:00:00

  • A Kernel-Based Low-Rank (KLR) Model for Low-Dimensional Manifold Recovery in Highly Accelerated Dynamic MRI.

    abstract::While many low rank and sparsity-based approaches have been developed for accelerated dynamic magnetic resonance imaging (dMRI), they all use low rankness or sparsity in input space, overlooking the intrinsic nonlinear correlation in most dMRI data. In this paper, we propose a kernel-based framework to allow nonlinear...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2017.2723871

    authors: Nakarmi U,Wang Y,Lyu J,Liang D,Ying L

    更新日期:2017-11-01 00:00:00

  • The adaptive bases algorithm for intensity-based nonrigid image registration.

    abstract::Nonrigid registration of medical images is important for a number of applications such as the creation of population averages, atlas-based segmentation, or geometric correction of functional magnetic resonance imaging (fMRI) images to name a few. In recent years, a number of methods have been proposed to solve this pr...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2003.819299

    authors: Rohde GK,Aldroubi A,Dawant BM

    更新日期:2003-11-01 00:00:00

  • Free-breathing diffusion tensor imaging and tractography of the human heart in healthy volunteers using wavelet-based image fusion.

    abstract::Free-breathing cardiac diffusion tensor imaging (DTI) is a promising but challenging technique for the study of fiber structures of the human heart in vivo. This work proposes a clinically compatible and robust technique to provide three-dimensional (3-D) fiber architecture properties of the human heart. To this end, ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2014.2356792

    authors: Wei H,Viallon M,Delattre BM,Moulin K,Yang F,Croisille P,Zhu Y

    更新日期:2015-01-01 00:00:00

  • Combined volumetric and surface registration.

    abstract::In this paper, we propose a novel method for the registration of volumetric images of the brain that optimizes the alignment of both cortical and subcortical structures. In order to achieve this, relevant geometrical information is extracted from a surface-based morph and diffused into the volume using the Navier oper...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2008.2004426

    authors: Postelnicu G,Zollei L,Fischl B

    更新日期:2009-04-01 00:00:00

  • Detecting Surgical Tools by Modelling Local Appearance and Global Shape.

    abstract::Detecting tools in surgical videos is an important ingredient for context-aware computer-assisted surgical systems. To this end, we present a new surgical tool detection dataset and a method for joint tool detection and pose estimation in 2d images. Our two-stage pipeline is data-driven and relaxes strong assumptions ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2015.2450831

    authors: Bouget D,Benenson R,Omran M,Riffaud L,Schiele B,Jannin P

    更新日期:2015-12-01 00:00:00

  • Spatio-temporal fMRI analysis using Markov random fields.

    abstract::Functional magnetic resonance images (fMRI's) provide high-resolution datasets which allow researchers to obtain accurate delineation and sensitive detection of activation areas involved in cognitive processes. To preserve the resolution of this noninvasive technique, refined methods are required in the analysis of th...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.746636

    authors: Descombes X,Kruggel F,von Cramon DY

    更新日期:1998-12-01 00:00:00

  • Lung and Pancreatic Tumor Characterization in the Deep Learning Era: Novel Supervised and Unsupervised Learning Approaches.

    abstract::Risk stratification (characterization) of tumors from radiology images can be more accurate and faster with computer-aided diagnosis (CAD) tools. Tumor characterization through such tools can also enable non-invasive cancer staging, prognosis, and foster personalized treatment planning as a part of precision medicine....

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2019.2894349

    authors: Hussein S,Kandel P,Bolan CW,Wallace MB,Bagci U

    更新日期:2019-08-01 00:00:00

  • Technique for reduction of truncation artifact in chemical shift images.

    abstract::The authors describe a technique to reduce truncation artifacts in chemical shift images taken for in vivo magnetic resonance spectroscopy by using boundary information available from anatomic images. In this approach, high spatial frequency components are extrapolated from the observed data by making use of the bound...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.97578

    authors: Hu X,Stillman AE

    更新日期:1991-01-01 00:00:00

  • True three-dimensional cone-beam reconstruction (TTCR) algorithm.

    abstract::A true three-dimensional cone-beam reconstruction (TTCR) algorithm for direct volume image reconstruction from 2-D cone-beam projections is developed for the complete sphere geometry. The algorithm is derived from the parallel-beam true three-dimensional reconstruction (TTR) algorithm and is based on the modified filt...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.41483

    authors: Lee SZ,Ra JB,Hilal SK,Cho ZH

    更新日期:1989-01-01 00:00:00

  • Framing U-Net via Deep Convolutional Framelets: Application to Sparse-View CT.

    abstract::X-ray computed tomography (CT) using sparse projection views is a recent approach to reduce the radiation dose. However, due to the insufficient projection views, an analytic reconstruction approach using the filtered back projection (FBP) produces severe streaking artifacts. Recently, deep learning approaches using l...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2018.2823768

    authors: Han Y,Ye JC

    更新日期:2018-06-01 00:00:00

  • Anti-aliasing weighting functions for single-slice helical CT.

    abstract::Spatially variant longitudinal aliasing plagues most volumes reconstructed from single-slice helical computed tomography data, and its presence can degrade resolution and distort image structures. We have recently developed a Fourier-based approach to longitudinal interpolation in helical computed tomography that can,...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2002.803104

    authors: La Rivière PJ,Pan X

    更新日期:2002-08-01 00:00:00

  • Shape-based normalization of the corpus callosum for DTI connectivity analysis.

    abstract::The continuous medial representation (cm-rep) is an approach that makes it possible to model, normalize, and analyze anatomical structures on the basis of medial geometry. Having recently presented a partial differential equation (PDE)-based approach for 3-D cm-rep modeling [1], here we present an equivalent 2-D appro...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2007.900322

    authors: Sun H,Yushkevich PA,Zhang H,Cook PA,Duda JT,Simon TJ,Gee JC

    更新日期:2007-09-01 00:00:00

  • Dynamic contrast-enhanced MRI-based early detection of acute renal transplant rejection.

    abstract::A novel framework for the classification of acute rejection versus nonrejection status of renal transplants from 2-D dynamic contrast-enhanced magnetic resonance imaging is proposed. The framework consists of four steps. First, kidney objects are segmented from adjacent structures with a level set deformable boundary ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2013.2269139

    authors: Khalifa F,Beache GM,El-Ghar MA,El-Diasty T,Gimel'farb G,Kong M,El-Baz A

    更新日期:2013-10-01 00:00:00

  • Mobile Biplane X-Ray Imaging System for Measuring 3D Dynamic Joint Motion During Overground Gait.

    abstract::Most X-ray fluoroscopy systems are stationary and impose restrictions on the measurement of dynamic joint motion; for example, knee-joint kinematics during gait is usually measured with the subject ambulating on a treadmill. We developed a computer-controlled, mobile, biplane, X-ray fluoroscopy system to track human b...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2015.2473168

    authors: Guan S,Gray HA,Keynejad F,Pandy MG

    更新日期:2016-01-01 00:00:00

  • Sparse reconstruction of the magnetic particle imaging system matrix.

    abstract::Magnetic particle imaging allows to determine the spatial distribution of magnetic nanoparticles in vivo. The system matrix in magnetic particle imaging is commonly acquired in a tedious calibration scan and requires to measure the system response at numerous positions in the field-of-view. In this paper, we propose a...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2013.2258029

    authors: Knopp T,Weber A

    更新日期:2013-08-01 00:00:00