Abstract:
:Cardiac resynchronization therapy (CRT) has been shown to improve cardiovascular function in specific patients suffering from heart failure. This procedure still needs to be optimized to overcome the high rate of implanted patients that do not respond to this therapy. We propose in this work a better characterization of the electro-mechanical (EM) coupling of each region of the left ventricle (LV) that could be useful to precise the best implantation site. A new descriptor is proposed with the extraction of local electro-mechanical delays. Their measurement is based on the fusion of anatomical, functional and electrical data acquired using computed tomography (CT), speckle tracking echocardiography (STE), and electro-anatomical mappings (EAM). We propose a workflow to place multimodal data in the same geometrical referential system and to extract local electro-mechanical descriptors. It implies the fusion of electrical and mechanical data on a 3D+ t anatomical model of the LV. It mainly consists in four steps: 1) the modeling of the endocardium using a dynamic surface estimated from CT images; 2) the semi-interactive registration of EAM data and CT images; 3) the automatic registration of STE data on the dynamic model, using a metric based on Fourier descriptors and dynamic time warping; 4) the temporal alignment between EAM and STE and the estimation of local electro-mechanical delays. The proposed process has been applied to real data corresponding to five patients undergoing CRT. Results show that local electro-mechanical delays provide meaningful information on the local characterization of the LV and may be useful for the optimal pacing site selection in CRT.
journal_name
IEEE Trans Med Imagingjournal_title
IEEE transactions on medical imagingauthors
Tavard F,Simon A,Leclercq C,Donal E,Hernández AI,Garreau Mdoi
10.1109/TMI.2014.2311694subject
Has Abstractpub_date
2014-06-01 00:00:00pages
1363-72issue
6eissn
0278-0062issn
1558-254Xjournal_volume
33pub_type
杂志文章abstract::A reconstruction algorithm to simultaneously estimate the shape and location of three-dimensional breast cancer tumor is presented and its utility is analyzed. The approach is based on a spherical harmonic decomposition to capture the shape of the tumor. We combine a gradient descent optimization method with a direct ...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/tmi.2006.881377
更新日期:2006-10-01 00:00:00
abstract::In positron emission tomography (PET) image reconstruction, the Bayesian framework with various regularization terms has been implemented to constrain the radio tracer distribution. Varying the regularizing weight of a maximum a posteriori (MAP) algorithm specifies a lower bound of the tradeoff between variance and sp...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2018.2803681
更新日期:2018-06-01 00:00:00
abstract::We show that electrical impedance tomography (EIT) image reconstruction algorithms with regularization based on the total variation (TV) functional are suitable for in vivo imaging of physiological data. This reconstruction approach helps to preserve discontinuities in reconstructed profiles, such as step changes in e...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2009.2022540
更新日期:2010-01-01 00:00:00
abstract::With continuing improvements in spatial resolution of positron emission tomography (PET) scanners, small patient movements during PET imaging become a significant source of resolution degradation. This work develops and investigates a comprehensive formalism for accurate motion-compensated reconstruction which at the ...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2008.917248
更新日期:2008-08-01 00:00:00
abstract::Acoustic-resolution photoacoustic micro-scopy (AR-PAM) is an emerging biomedical imaging modality that combines superior optical sensitivity and fine ultrasonic resolution in an optical quasi-diffusive regime (~1-3 mm in tissues). AR-PAM has been explored for anatomical, functional, and molecular information in biolog...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2019.2938518
更新日期:2020-04-01 00:00:00
abstract::We describe a nonparametric framework for incorporating information from co-registered anatomical images into positron emission tomographic (PET) image reconstruction through priors based on information theoretic similarity measures. We compare and evaluate the use of mutual information (MI) and joint entropy (JE) bet...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2010.2076827
更新日期:2011-03-01 00:00:00
abstract::We propose a novel, physics-based method for detecting multi-scale tubular features in ultrasound images. The detector is based on a Hessian-matrix eigenvalue method, but unlike previous work, our detector is guided by an optimal model of vessel-like structures with respect to the ultrasound-image formation process. O...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2014.2340912
更新日期:2015-01-01 00:00:00
abstract::Optical Diffusion Tomography (ODT) is a modern non-invasive medical imaging modality which requires mathematical modelling of near-infrared light propagation in tissue. Solving the ODT forward problem equation accurately and efficiently is crucial. Typically, the forward problem is represented by a Diffusion PDE and i...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2016.2641500
更新日期:2017-04-01 00:00:00
abstract::Optical coherence tomography (OCT) uses retroreflected light to provide micrometer-resolution, cross-sectional scans of biological tissues. OCT's first application was in ophthalmic imaging where it has proven particularly useful in diagnosing, monitoring, and studying glaucoma. Diagnosing glaucoma is difficult and it...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2006.871417
更新日期:2006-05-01 00:00:00
abstract::The analysis of MR images is evolving from qualitative to quantitative. More and more, the question asked by clinicians is how much and where, rather than a simple statement on the presence or absence of abnormalities. The authors present a study in which the results obtained with a semiautomatic, multispectral segmen...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.363096
更新日期:1994-01-01 00:00:00
abstract::In this paper, we propose a novel method for the registration of volumetric images of the brain that optimizes the alignment of both cortical and subcortical structures. In order to achieve this, relevant geometrical information is extracted from a surface-based morph and diffused into the volume using the Navier oper...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2008.2004426
更新日期:2009-04-01 00:00:00
abstract::Magnetic particle imaging (MPI) is able to provide high temporal and good spatial resolution, high signal to noise ratio and sensitivity. Furthermore, it is a truly quantitative method as its signal strength is proportional to the concentration of its tracer, superparamagnetic iron oxide nanoparticles (SPIOs), over a ...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2016.2559538
更新日期:2016-10-01 00:00:00
abstract::Optical coherence tomography (OCT) is a well-established image modality in ophthalmology and used daily in the clinic. Automatic evaluation of such datasets requires an accurate segmentation of the retinal cell layers. However, due to the naturally low signal to noise ratio and the resulting bad image quality, this ta...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2012.2225152
更新日期:2013-03-01 00:00:00
abstract::A robust automated segmentation of abdominal organs can be crucial for computer aided diagnosis and laparoscopic surgery assistance. Many existing methods are specialized to the segmentation of individual organs and struggle to deal with the variability of the shape and position of abdominal organs. We present a gener...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2013.2265805
更新日期:2013-09-01 00:00:00
abstract::Anisotropic multi-slice Cardiac Magnetic Resonance (CMR) Images are conventionally acquired in patient-specific short-axis (SAX) orientation. In specific cardiovascular diseases that affect right ventricular (RV) morphology, acquisitions in standard axial (AX) orientation are preferred by some investigators, due to po...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2021.3052972
更新日期:2021-01-20 00:00:00
abstract::New biopsy techniques, increased life expectancy, and prostate-specific antigen (PSA) screening have contributed to an increase in the reported incidence of prostate cancer. Among several treatment options available to the patients, transperineal prostate brachytherapy has emerged as a medically successful, cost-effec...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.736032
更新日期:1998-10-01 00:00:00
abstract::This paper addresses the implementation of image processing and computer vision techniques to automate tracer flow extraction in images obtained by the photochromic dye technique. This task is important in modeled arterial blood flow studies. Currently, it is performed via manual application of B-spline curve fitting....
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.585762
更新日期:1997-06-01 00:00:00
abstract::Classical surgery is being overtaken by minimally invasive and transcatheter procedures. As there is no direct view or access to the affected anatomy, advanced imaging techniques such as 3D C-arm computed tomography (CT) and C-arm fluoroscopy are routinely used in clinical practice for intraoperative guidance. However...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2014.2343936
更新日期:2015-01-01 00:00:00
abstract::Arterial spin labeling (ASL) is an MRI perfusion imaging method from which quantitative cerebral blood flow (CBF) can be calculated. We present a multi-TI ASL method (multi-TI integrated ASL) in which variable post-labeling delays and variable TRs are used to improve the estimation of arterial transit time (ATT) and C...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2015.2395257
更新日期:2015-06-01 00:00:00
abstract::We demonstrate three-dimensional intravascular flow imaging compatible with routine clinical image acquisition workflow by means of megahertz (MHz) intravascular Doppler Optical Coherence Tomography (OCT). The OCT system relies on a 1.1 mm diameter motorized imaging catheter and a 1.5 MHz Fourier Domain Mode Locked (F...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2019.2948258
更新日期:2020-05-01 00:00:00
abstract::Hand-bone analysis with image processing techniques using a digital radiograph can be used to assess skeletal age. The analysis consists of two steps: phalangeal and carpal bone analysis. The carpal bone analysis is discussed. First, the carpal bone region of interest (CROI) is defined using a standard thresholding te...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.222665
更新日期:1993-01-01 00:00:00
abstract::The existence of diverse image datasets accompanied by reference annotations is a crucial prerequisite for an objective benchmarking of bioimage analysis methods. Nevertheless, such a prerequisite is hard to satisfy for time lapse, multidimensional fluorescence microscopy image data, manual annotations of which are la...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2018.2845884
更新日期:2018-12-01 00:00:00
abstract::We compare different possible scanning geometries for prostate photoacoustic tomography (PAT) while considering a realistic reconstruction scenario in which the limited view of the prostate and the directivity effect of the transducer are considered. Simulations and experiments confirm that an intra-operative configur...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2018.2855166
更新日期:2019-01-01 00:00:00
abstract::The solution of impedance distribution in electrical impedance tomography is a nonlinear inverse problem that requires the use of a regularization method. The generalized Tikhonov regularization methods have been popular in the solution of many inverse problems. The regularization matrices that are usually used with t...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.700740
更新日期:1998-04-01 00:00:00
abstract::We propose a method that incorporates the time-frequency characteristics of neural sources into magnetoencephalographic (MEG) source estimation. The method is based on the multiple-signal-classification (MUSIC) algorithm and it calculates a time--frequency matrix in which diagonal and off-diagonal terms are the auto a...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.750262
更新日期:1999-01-01 00:00:00
abstract::In this paper, we propose a new prostate computed tomography (CT) segmentation method for image guided radiation therapy. The main contributions of our method lie in the following aspects. 1) Instead of using voxel intensity information alone, patch-based representation in the discriminative feature space with logisti...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2012.2230018
更新日期:2013-02-01 00:00:00
abstract::We present an integrated approach to probabilistic independent component analysis (ICA) for functional MRI (FMRI) data that allows for nonsquare mixing in the presence of Gaussian noise. In order to avoid overfitting, we employ objective estimation of the amount of Gaussian noise through Bayesian analysis of the true ...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2003.822821
更新日期:2004-02-01 00:00:00
abstract::Groupwise nonrigid image registration is a powerful tool to automatically establish correspondences across sets of images. Such correspondences are widely used for constructing statistical models of shape and appearance. As existing techniques usually treat registration as an optimization problem, a good initializatio...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2011.2169077
更新日期:2012-02-01 00:00:00
abstract::Contrast source inversion-electrical properties tomography (CSI-EPT) is an iterative reconstruction method to retrieve the electrical properties (EPs) of tissues from magnetic resonance data. The method is based on integral representations of the electromagnetic field and has been shown to allow EP reconstructions of ...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2018.2816125
更新日期:2018-09-01 00:00:00
abstract::Three-dimensional (3-D) reconstructions of coronary bypass grafts performed from X-ray angiographic images may become increasingly important for the investigation of damaging mechanical stresses imposed to these vessels by the cyclic movement of the heart. Contrary to what we had experienced with coronary arteries, ap...
journal_title:IEEE transactions on medical imaging
pub_type: 信件
doi:10.1109/42.875203
更新日期:2000-07-01 00:00:00