Abstract:
:A system for digital flashing tomosynthesis (DFTS) consists of four ECG-gated simultaneously flashed X-ray tubes, a 14-in image intensifier, a unit for digital subtraction angiography (DSA), a PC-hosted transputer network for three-dimensional (3-D) reconstruction as well as for quantitative coronary angiography and ventriculography, a display unit, and an individual digital archive. A presentation of DFTS tomoangiograms as a single slice or multiple slices of arbitrary thickness is available. DFTS also offers rotating and stereographic presentation of 3-D images. DFTS represents a system for standardized digital angiocardiography with digital archiving, and assures optimal reproducibility and safety. This system is feasible for both an ambulatory basis to allow high-volume cardiovascular angiographic screening by only one X-ray snapshot, and for quantification of natural progression or potential regression of coronary artery disease resulting from interventional or pharmacological therapy.
journal_name
IEEE Trans Med Imagingjournal_title
IEEE transactions on medical imagingauthors
Stiel GM,Stiel LG,Klotz E,Nienaber CAdoi
10.1109/42.232261subject
Has Abstractpub_date
1993-01-01 00:00:00pages
314-21issue
2eissn
0278-0062issn
1558-254Xjournal_volume
12pub_type
杂志文章abstract::We present and validate a novel registration algorithm mapping two data sets, generated from a rigid object, in the presence of Gaussian noise. The proposed method is based on the Unscented Kalman Filter (UKF) algorithm that is generally employed for analyzing nonlinear systems corrupted by additive Gaussian noise. Fi...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/tmi.2007.901984
更新日期:2007-12-01 00:00:00
abstract::Prostate cancer (PCa) recurrences are often predicted by assessing the status of surgical margins (SM)- positive surgical margins (PSM) increase the chances of biochemical recurrence by 2-4 times which may lead to PCa recurrence. To this end, an electrical impedance acquisition system with a microendoscopic probe was ...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2016.2578939
更新日期:2016-12-01 00:00:00
abstract::Arterial spin labeling (ASL) is an MRI perfusion imaging method from which quantitative cerebral blood flow (CBF) can be calculated. We present a multi-TI ASL method (multi-TI integrated ASL) in which variable post-labeling delays and variable TRs are used to improve the estimation of arterial transit time (ATT) and C...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2015.2395257
更新日期:2015-06-01 00:00:00
abstract::Several techniques based on the three-dimensional (3-D) discrete cosine transform (DCT) have been proposed for volumetric data coding. These techniques fail to provide lossless coding coupled with quality and resolution scalability, which is a significant drawback for medical applications. This paper gives an overview...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/tmi.2003.809582
更新日期:2003-03-01 00:00:00
abstract::Radiation therapy (RT) has been widely used as a powerful treatment tool to address cancerous tissues because of its ability to control cell growth. Its ionizing radiation damages the DNA of cancerous tissues, leading to cell death. Medical imaging, however, still has limitations regarding the reliability of its asses...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2019.2913766
更新日期:2019-12-01 00:00:00
abstract::We describe the efficient algebraic reconstruction (EAR) method, which applies to cone-beam tomographic reconstruction problems with a circular symmetry. Three independant steps/stages are presented, which use two symmetries and a factorization of the point spread functions (PSFs), each reducing computing times and ev...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2005.861707
更新日期:2006-02-01 00:00:00
abstract::In picture archiving and communications systems (PACS), images need to be displayed in standardized ways for radiologists' interpretations. However, for most radiographs acquired via computed radiography (CR), digital radiography (DR), or digitized films, the image orientation is undetermined because of the variations...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/tmi.2006.880677
更新日期:2006-10-01 00:00:00
abstract::Short-echo-time (TE) proton magnetic resonance spectroscopic imaging (MRSI) allows for simultaneously mapping a number of molecules in the brain, and has been recognized as an important tool for studying in vivo biochemistry in various neuroscience and disease applications. However, separation of the metabolite and ma...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2020.3048933
更新日期:2021-01-04 00:00:00
abstract::Passive monitoring of the thermal noise variances of the channels of a receive array was shown to reveal respiratory motion of the underlying anatomy, a so called "noise navigator". There is, however, an inevitable trade off between the accuracy and temporal resolution of the noise navigator due to its passive nature....
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2018.2808699
更新日期:2018-08-01 00:00:00
abstract::Radio-frequency (RF) transceiver array design using primary and higher order harmonics for in vivo parallel magnetic resonance imaging imaging (MRI) and spectroscopic imaging is proposed. The improved electromagnetic decoupling performance, unique magnetic field distributions and high-frequency operation capabilities ...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2011.2166273
更新日期:2012-02-01 00:00:00
abstract::Transmembrane voltage-sensitive fluorescent dyes are used to study electrical activity in hearts. Green and red fluorescence emissions from di-4-ANEPPS excited with 488 nm light indicate both transmembrane voltage changes and heart movement. We have previously shown that the ratio, green fluorescence divided by red fl...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2005.861019
更新日期:2006-01-01 00:00:00
abstract::The development of an automatic telemedicine system for computer-aided screening and grading of diabetic retinopathy depends on reliable detection of retinal lesions in fundus images. In this paper, a novel method for automatic detection of both microaneurysms and hemorrhages in color fundus images is described and va...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2015.2509785
更新日期:2016-04-01 00:00:00
abstract::This paper establishes for the first time that a coupled ultrasound (US) and electrical impedance tomography (EIT) system can serve as a non-invasive, spatially localized approach to extract clinically relevant muscle properties. The US/EIT system represents a potential enhancement to electrical impedance myography (E...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2018.2886152
更新日期:2019-06-01 00:00:00
abstract::It is known that when the maximum likelihood estimator (MLE) algorithm passes a certain point, it produces images that begin to deteriorate. We propose a quantitative criterion with a simple probabilistic interpretation that allows the user to stop the algorithm just before this effect begins. The MLE algorithm search...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.1987.4307849
更新日期:1987-01-01 00:00:00
abstract::High-resolution X-ray computed tomography (CT) imaging is routinely used for clinical pulmonary applications. Since lung function varies regionally and because pulmonary disease is usually not uniformly distributed in the lungs, it is useful to study the lungs on a lobe-by-lobe basis. Thus, it is important to segment ...
journal_title:IEEE transactions on medical imaging
pub_type: 临床试验,杂志文章
doi:10.1109/TMI.2005.859209
更新日期:2006-01-01 00:00:00
abstract::Dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) of the breast has become an invaluable tool in the clinical work-up of patients suspected of having breast carcinoma. The purpose of this study is to introduce novel features extracted from the kinetics of contrast agent uptake imaged by a short (100 s) vi...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2013.2281984
更新日期:2014-02-01 00:00:00
abstract::In open image-guided liver surgery (IGLS), a sparse representation of the intraoperative organ surface can be acquired to drive image-to-physical registration. We hypothesize that uncharacterized error induced by variation in the collection patterns of organ surface data limits the accuracy and robustness of an IGLS r...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2017.2668842
更新日期:2017-07-01 00:00:00
abstract::The study presented in this paper tests the hypothesis that the combination of a global similarity transformation and local free-form deformations can be used for the accurate segmentation of internal structures in MR images of the brain. To quantitatively evaluate our approach, the entire brain, the cerebellum, and t...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.811271
更新日期:1999-10-01 00:00:00
abstract::This paper examines the use of the algebraic reconstruction technique (ART) and related techniques to reconstruct 3-D objects from a relatively sparse set of cone-beam projections. Although ART has been widely used for cone-beam reconstruction of high-contrast objects, e.g., in computed angiography, the work presented...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.781017
更新日期:1999-06-01 00:00:00
abstract::The effects of Squashing, an algorithm introduced by J.A. Reeds and L.A. Shepp (see ibid., vol.MI-6, no.2, p.89-97, June 1987), are described. It is proven that Squashing induces a weight function upon the projections. Intuitive and numerical evidence is presented showing that this weight function is not desirable at ...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.57761
更新日期:1990-01-01 00:00:00
abstract::The identification of bronchi on Computed Tomography (CT) images of the lungs provides valuable clinical information in patients with suspected airways diseases including bronchiectasis, emphysema, or constrictive obliterative bronchiolitis. The automated recognition of the airways is, therefore, an important part of ...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.952731
更新日期:2001-09-01 00:00:00
abstract::Deep learning is becoming an indispensable tool for various tasks in science and engineering. A critical step in constructing a reliable deep learning model is the selection of a loss function, which measures the discrepancy between the network prediction and the ground truth. While a variety of loss functions have be...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2020.3031913
更新日期:2020-10-19 00:00:00
abstract::The segmentation of the human airway tree from volumetric computed tomography (CT) images builds an important step for many clinical applications and for physiological studies. Previously proposed algorithms suffer from one or several problems: leaking into the surrounding lung parenchyma, the need for the user to man...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2005.857654
更新日期:2005-12-01 00:00:00
abstract::Generalized matrix inverses are used to estimate source activity distributions from single photon emission computed tomography (SPECT) projection measurements. Image reconstructions for a numerical simulation and a clinical brain study are examined. The photon flux from the source region and photon detection by the ga...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.141640
更新日期:1992-01-01 00:00:00
abstract::We propose a novel dynamic image reconstruction method from PET listmode data that could be particularly suited to tracking single or small numbers of cells. In contrast to conventional PET reconstruction our method combines the information from all detected events not only to reconstruct the dynamic evolution of the ...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2019.2953773
更新日期:2020-05-01 00:00:00
abstract::We show that electrical impedance tomography (EIT) image reconstruction algorithms with regularization based on the total variation (TV) functional are suitable for in vivo imaging of physiological data. This reconstruction approach helps to preserve discontinuities in reconstructed profiles, such as step changes in e...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2009.2022540
更新日期:2010-01-01 00:00:00
abstract::Video capsule endoscopy (VCE) is a noninvasive method for examining the gastrointestinal tract which has been successful in small intestine studies. Recently, VCE has been attempted in the colon. However, the capsule often tumbles in the wider colonic lumen, resulting in missed regions. Self-stabilizing VCE is a novel...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2011.2163165
更新日期:2011-12-01 00:00:00
abstract::Instrument detection, pose estimation, and tracking in surgical videos are an important vision component for computer-assisted interventions. While significant advances have been made in recent years, articulation detection is still a major challenge. In this paper, we propose a deep neural network for articulated mul...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2017.2787672
更新日期:2018-05-01 00:00:00
abstract::Colorectal cancer can easily be prevented provided that the precursors to tumors, small colonic polyps, are detected and removed. Currently, the only definitive examination of the colon is fiber-optic colonoscopy, which is invasive and expensive. Computed tomographic colonography (CTC) is potentially a less costly and...
journal_title:IEEE transactions on medical imaging
pub_type: 临床试验,杂志文章
doi:10.1109/TMI.2002.806405
更新日期:2002-12-01 00:00:00
abstract::Magnetic particle imaging allows to determine the spatial distribution of magnetic nanoparticles in vivo. The system matrix in magnetic particle imaging is commonly acquired in a tedious calibration scan and requires to measure the system response at numerous positions in the field-of-view. In this paper, we propose a...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2013.2258029
更新日期:2013-08-01 00:00:00