Atlas-driven lung lobe segmentation in volumetric X-ray CT images.

Abstract:

:High-resolution X-ray computed tomography (CT) imaging is routinely used for clinical pulmonary applications. Since lung function varies regionally and because pulmonary disease is usually not uniformly distributed in the lungs, it is useful to study the lungs on a lobe-by-lobe basis. Thus, it is important to segment not only the lungs, but the lobar fissures as well. In this paper, we demonstrate the use of an anatomic pulmonary atlas, encoded with a priori information on the pulmonary anatomy, to automatically segment the oblique lobar fissures. Sixteen volumetric CT scans from 16 subjects are used to construct the pulmonary atlas. A ridgeness measure is applied to the original CT images to enhance the fissure contrast. Fissure detection is accomplished in two stages: an initial fissure search and a final fissure search. A fuzzy reasoning system is used in the fissure search to analyze information from three sources: the image intensity, an anatomic smoothness constraint, and the atlas-based search initialization. Our method has been tested on 22 volumetric thin-slice CT scans from 12 subjects, and the results are compared to manual tracings. Averaged across all 22 data sets, the RMS error between the automatically segmented and manually segmented fissures is 1.96 +/- 0.71 mm and the mean of the similarity indices between the manually defined and computer-defined lobe regions is 0.988. The results indicate a strong agreement between the automatic and manual lobe segmentations.

journal_name

IEEE Trans Med Imaging

authors

Zhang L,Hoffman EA,Reinhardt JM

doi

10.1109/TMI.2005.859209

subject

Has Abstract

pub_date

2006-01-01 00:00:00

pages

1-16

issue

1

eissn

0278-0062

issn

1558-254X

journal_volume

25

pub_type

临床试验,杂志文章
  • Low-field 3-DFT MRI: conceptual, analytical, and experimental aspects.

    abstract::Three-dimensional Fourier transform (3-DFT) magnetic resonance imaging (MRI) offers advantages in terms of signal-to-noise (S/N) per unit of time for the case where a large number of slices is desired. This advantage is enhanced when the relaxation time, T(1 ), is short. Because time limitations in 3-DFT imaging force...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.97588

    authors: Kramer DM,Kaufman L,Rothschild P,Hale J,Wummer J,Hake KK

    更新日期:1991-01-01 00:00:00

  • Robust super-resolution volume reconstruction from slice acquisitions: application to fetal brain MRI.

    abstract::Fast magnetic resonance imaging slice acquisition techniques such as single shot fast spin echo are routinely used in the presence of uncontrollable motion. These techniques are widely used for fetal magnetic resonance imaging (MRI) and MRI of moving subjects and organs. Although high-quality slices are frequently acq...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2010.2051680

    authors: Gholipour A,Estroff JA,Warfield SK

    更新日期:2010-10-01 00:00:00

  • A direct reconstruction algorithm for electrical impedance tomography.

    abstract::A direct (noniterative) reconstruction algorithm for electrical impedance tomography in the two-dimensional (2-D), cross-sectional geometry is reviewed. New results of a reconstruction of a numerically simulated phantom chest are presented. The algorithm is based on the mathematical uniqueness proof by A. I. Nachman [...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2002.800574

    authors: Mueller JL,Siltanen S,Isaacson D

    更新日期:2002-06-01 00:00:00

  • Out-of-plane motion compensation in multislice spin-echo MRI.

    abstract::In magnetic resonance imaging (MRI), it is well-known that patient motion plays a significant role in the degradation of image quality. Although the case of translational in-plane motion (x-y-motion) has been studied by several researchers, the effect of rigid, translational out-of-plane motion (z-motion) has not yet ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.414611

    authors: Riek JK,Tekalp AM,Smith WE,Kwok E

    更新日期:1995-01-01 00:00:00

  • Retinal vessel centerline extraction using multiscale matched filters, confidence and edge measures.

    abstract::Motivated by the goals of improving detection of low-contrast and narrow vessels and eliminating false detections at nonvascular structures, a new technique is presented for extracting vessels in retinal images. The core of the technique is a new likelihood ratio test that combines matched-filter responses, confidence...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/tmi.2006.884190

    authors: Sofka M,Stewart CV

    更新日期:2006-12-01 00:00:00

  • Clustered components analysis for functional MRI.

    abstract::A common method of increasing hemodynamic response (SNR) in functional magnetic resonance imaging (fMRI) is to average signal timecourses across voxels. This technique is potentially problematic because the hemodynamic response may vary across the brain. Such averaging may destroy significant features in the temporal ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2003.819922

    authors: Chen S,Bouman CA,Lowe MJ

    更新日期:2004-01-01 00:00:00

  • Fast catheter segmentation from echocardiographic sequences based on segmentation from corresponding X-ray fluoroscopy for cardiac catheterization interventions.

    abstract::Echocardiography is a potential alternative to X-ray fluoroscopy in cardiac catheterization given its richness in soft tissue information and its lack of ionizing radiation. However, its small field of view and acoustic artifacts make direct automatic segmentation of the catheters very challenging. In this study, a fa...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2014.2360988

    authors: Wu X,Housden J,Ma Y,Razavi B,Rhode K,Rueckert D

    更新日期:2015-04-01 00:00:00

  • Patch-Based Output Space Adversarial Learning for Joint Optic Disc and Cup Segmentation.

    abstract::Glaucoma is a leading cause of irreversible blindness. Accurate segmentation of the optic disc (OD) and optic cup (OC) from fundus images is beneficial to glaucoma screening and diagnosis. Recently, convolutional neural networks demonstrate promising progress in the joint OD and OC segmentation. However, affected by t...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2019.2899910

    authors: Wang S,Yu L,Yang X,Fu CW,Heng PA

    更新日期:2019-11-01 00:00:00

  • A Kernel-Based Low-Rank (KLR) Model for Low-Dimensional Manifold Recovery in Highly Accelerated Dynamic MRI.

    abstract::While many low rank and sparsity-based approaches have been developed for accelerated dynamic magnetic resonance imaging (dMRI), they all use low rankness or sparsity in input space, overlooking the intrinsic nonlinear correlation in most dMRI data. In this paper, we propose a kernel-based framework to allow nonlinear...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2017.2723871

    authors: Nakarmi U,Wang Y,Lyu J,Liang D,Ying L

    更新日期:2017-11-01 00:00:00

  • Point-based rigid-body registration using an unscented Kalman filter.

    abstract::We present and validate a novel registration algorithm mapping two data sets, generated from a rigid object, in the presence of Gaussian noise. The proposed method is based on the Unscented Kalman Filter (UKF) algorithm that is generally employed for analyzing nonlinear systems corrupted by additive Gaussian noise. Fi...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/tmi.2007.901984

    authors: Moghari MH,Abolmaesumi P

    更新日期:2007-12-01 00:00:00

  • MDM-PCCT: Multiple Dynamic Modulations for High-Performance Spectral PCCT Imaging.

    abstract::Photon counting computed tomography (PCCT) has the ability to identify individual photons, resulting in quantitative material identification. Meanwhile, several technical challenges still exist in current PCCT imaging systems, including increased noise and suboptimal bin selection. These nonideal effects can substanti...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2020.3001616

    authors: Li D,Zeng D,Li S,Ge Y,Bian Z,Huang J,Ma J

    更新日期:2020-11-01 00:00:00

  • Measurement of mean and variance of velocity fields within each voxel by NMR imaging.

    abstract::If a flow field exists within an object that is being imaged, there could be a velocity spectrum in each voxel due to the finite voxel size. Consequently, the mean value and the variance of velocity in each voxel can be defined and used to describe the velocity spectrum. An NMR (nuclear magnetic resonance) imaging tec...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.14520

    authors: Xiang QS,Nalcioglu O

    更新日期:1988-01-01 00:00:00

  • Sparse reconstruction of the magnetic particle imaging system matrix.

    abstract::Magnetic particle imaging allows to determine the spatial distribution of magnetic nanoparticles in vivo. The system matrix in magnetic particle imaging is commonly acquired in a tedious calibration scan and requires to measure the system response at numerous positions in the field-of-view. In this paper, we propose a...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2013.2258029

    authors: Knopp T,Weber A

    更新日期:2013-08-01 00:00:00

  • Estimation of the hemodynamic response in event-related functional MRI: Bayesian networks as a framework for efficient Bayesian modeling and inference.

    abstract::A convenient way to analyze blood-oxygen-level-dependent functional magnetic resonance imaging data consists of modeling the whole brain as a stationary, linear system characterized by its transfer function: the hemodynamic response function (HRF). HRF estimation, though of the greatest interest, is still under invest...

    journal_title:IEEE transactions on medical imaging

    pub_type: 临床试验,杂志文章

    doi:10.1109/TMI.2004.831221

    authors: Marrelec G,Ciuciu P,Pélégrini-Issac M,Benali H

    更新日期:2004-08-01 00:00:00

  • Soft tissue differentiation using multiband signatures of high resolution ultrasonic transmission tomography.

    abstract::In this paper, we are interested in soft tissue differentiation by multiband images obtained from the High-Resolution Ultrasonic Transmission Tomography (HUTT) system using a spectral target detection method based on constrained energy minimization (CEM). We have developed a new tissue differentiation method (called "...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/tmi.2004.843179

    authors: Jeong JW,Kim TS,Shin DC,Do S,Singh M,Marmarelis VZ

    更新日期:2005-03-01 00:00:00

  • A Magnetic Resonance Imaging Surface Coil Transceiver Employing a Metasurface for 1.5T Applications.

    abstract::A capacitive impedance metasurface combined with a transceiver coil to improve the radio frequency magnetic field for 1.5T magnetic resonance imaging applications is presented. The novel transceiver provides localized enhancement in magnetic flux density when compared to a transceiver coil alone by incorporating an el...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2019.2942194

    authors: Issa I,Ford KL,Rao M,Wild JM

    更新日期:2020-04-01 00:00:00

  • Repeatability of linear and nonlinear elastic modulus maps from repeat scans in the breast.

    abstract::Compression elastography allows the precise measurement of large deformations of soft tissue in vivo. From an image sequence showing tissue undergoing large deformation, an inverse problem for both the linear and nonlinear elastic moduli distributions can be solved. As part of a larger clinical study to evaluate nonli...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2020.3036032

    authors: Gendin DI,Nayak R,Wang Y,Bayat M,Fazzio RT,Oberai AA,Hall TJ,Barbone PE,Alizad A,Fatemi M

    更新日期:2020-11-05 00:00:00

  • Restoration of signal polarity in a set of inversion recovery NMR images.

    abstract::A method is described which enables unambiguous retrieval of sign information in a set of magnetic resonance magnitude images of the inversion recovery type. The proposed method starts from the observation that the inversion recovery curve S is a monotonically increasing function of the inversion time TI, and comes do...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.1984.4307681

    authors: Bakker CG,De Graaf CN,Van Dijk P

    更新日期:1984-01-01 00:00:00

  • Simultaneous Analysis of 2D Echo Views for Left Atrial Segmentation and Disease Detection.

    abstract::We propose a joint information approach for automatic analysis of 2D echocardiography (echo) data. The approach combines a priori images, their segmentations and patient diagnostic information within a unified framework to determine various clinical parameters, such as cardiac chamber volumes, and cardiac disease labe...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2016.2593900

    authors: Allan G,Nouranian S,Tsang T,Seitel A,Mirian M,Jue J,Hawley D,Fleming S,Gin K,Swift J,Rohling R,Abolmaesumi P

    更新日期:2017-01-01 00:00:00

  • Robust Empirical Bayesian Reconstruction of Distributed Sources for Electromagnetic Brain Imaging.

    abstract::Electromagnetic brain imaging is the reconstruction of brain activity from non-invasive recordings of the magnetic fields and electric potentials. An enduring challenge in this imaging modality is estimating the number, location, and time course of sources, especially for the reconstruction of distributed brain source...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2019.2932290

    authors: Cai C,Diwakar M,Chen D,Sekihara K,Nagarajan SS

    更新日期:2020-03-01 00:00:00

  • Automated detection of prostatic adenocarcinoma from high-resolution ex vivo MRI.

    abstract::Prostatic adenocarcinoma is the most commonly occurring cancer among men in the United States, second only to skin cancer. Currently, the only definitive method to ascertain the presence of prostatic cancer is by trans-rectal ultrasound (TRUS) directed biopsy. Owing to the poor image quality of ultrasound, the accurac...

    journal_title:IEEE transactions on medical imaging

    pub_type: 临床试验,杂志文章

    doi:10.1109/TMI.2005.859208

    authors: Madabhushi A,Feldman MD,Metaxas DN,Tomaszeweski J,Chute D

    更新日期:2005-12-01 00:00:00

  • A probabilistic model-based approach to consistent white matter tract segmentation.

    abstract::Since the invention of diffusion magnetic resonance imaging (dMRI), currently the only established method for studying white matter connectivity in a clinical environment, there has been a great deal of interest in the effects of various pathologies on the connectivity of the brain. As methods for in vivo tractography...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2007.905826

    authors: Clayden JD,Storkey AJ,Bastin ME

    更新日期:2007-11-01 00:00:00

  • Digital mammography: mixed feature neural network with spectral entropy decision for detection of microcalcifications.

    abstract::A computationally efficient mixed feature based neural network (MFNN) is proposed for the detection of microcalcification clusters (MCCs) in digitized mammograms. The MFNN employs features computed in both the spatial and spectral domain and uses spectral entropy as a decision parameter. Backpropagation with Kalman fi...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.538936

    authors: Zheng B,Qian W,Clarke LP

    更新日期:1996-01-01 00:00:00

  • Dual Energy Differential Phase Contrast CT (DE-DPC-CT) Imaging.

    abstract::When more than two elemental materials are present in a given object, material quantification may not be robust and accurate when the routine two-material decomposition scheme in current dual energy CT imaging is employed. In this work, we present an innovative scheme to accomplish accurate three-material decompositio...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2020.2990347

    authors: Ji X,Zhang R,Li K,Chen GH

    更新日期:2020-11-01 00:00:00

  • Efficient Lattice Boltzmann Solver for Patient-Specific Radiofrequency Ablation of Hepatic Tumors.

    abstract::Radiofrequency ablation (RFA) is an established treatment for liver cancer when resection is not possible. Yet, its optimal delivery is challenged by the presence of large blood vessels and the time-varying thermal conductivity of biological tissue. Incomplete treatment and an increased risk of recurrence are therefor...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2015.2406575

    authors: Audigier C,Mansi T,Delingette H,Rapaka S,Mihalef V,Carnegie D,Boctor E,Choti M,Kamen A,Ayache N,Comaniciu D

    更新日期:2015-07-01 00:00:00

  • Toward Electrical Impedance Tomography Coupled Ultrasound Imaging for Assessing Muscle Health.

    abstract::This paper establishes for the first time that a coupled ultrasound (US) and electrical impedance tomography (EIT) system can serve as a non-invasive, spatially localized approach to extract clinically relevant muscle properties. The US/EIT system represents a potential enhancement to electrical impedance myography (E...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2018.2886152

    authors: Murphy EK,Skinner J,Martucci M,Rutkove SB,Halter RJ

    更新日期:2019-06-01 00:00:00

  • Border detection on digitized skin tumor images.

    abstract::A radial search technique is presented for detecting skin tumor borders in clinical dermatology images. First, it includes two rounds of radial search based on the same tumor center. The first-round search is independent, and the second-round search is knowledge-based tracking. Then a rescan with a new center is used ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.896789

    authors: Zhang Z,Stoecker WV,Moss RH

    更新日期:2000-11-01 00:00:00

  • Comb-push ultrasound shear elastography (CUSE): a novel method for two-dimensional shear elasticity imaging of soft tissues.

    abstract::Fast and accurate tissue elasticity imaging is essential in studying dynamic tissue mechanical properties. Various ultrasound shear elasticity imaging techniques have been developed in the last two decades. However, to reconstruct a full field-of-view 2-D shear elasticity map, multiple data acquisitions are typically ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2012.2205586

    authors: Song P,Zhao H,Manduca A,Urban MW,Greenleaf JF,Chen S

    更新日期:2012-09-01 00:00:00

  • A versatile wavelet domain noise filtration technique for medical imaging.

    abstract::In this paper, we propose a robust wavelet domain method for noise filtering in medical images. The proposed method adapts itself to various types of image noise as well as to the preference of the medical expert; a single parameter can be used to balance the preservation of (expert-dependent) relevant details against...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2003.809588

    authors: Pizurica A,Philips W,Lemahieu I,Acheroy M

    更新日期:2003-03-01 00:00:00

  • Radiographic image sequence coding using two-stage adaptive vector quantization.

    abstract::A two-stage adaptive vector quantization scheme for radiographic image sequence coding is introduced. Each frame in the sequence is first decomposed into a set of vectors, corresponding to nonoverlapping spatially contiguous block of pixels. A codebook is generated using a training set of vectors drawn from the sequen...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.3938

    authors: Sun H,Goldberg M

    更新日期:1988-01-01 00:00:00