A probabilistic model-based approach to consistent white matter tract segmentation.

Abstract:

:Since the invention of diffusion magnetic resonance imaging (dMRI), currently the only established method for studying white matter connectivity in a clinical environment, there has been a great deal of interest in the effects of various pathologies on the connectivity of the brain. As methods for in vivo tractography have been developed, it has become possible to track and segment specific white matter structures of interest for particular study. However, the consistency and reproducibility of tractography-based segmentation remain limited, and attempts to improve them have thus far typically involved the imposition of strong constraints on the tract reconstruction process itself. In this work we take a different approach, developing a formal probabilistic model for the relationships between comparable tracts in different scans, and then using it to choose a tract, a posteriori, which best matches a predefined reference tract for the structure of interest. We demonstrate that this method is able to significantly improve segmentation consistency without directly constraining the tractography algorithm.

journal_name

IEEE Trans Med Imaging

authors

Clayden JD,Storkey AJ,Bastin ME

doi

10.1109/TMI.2007.905826

subject

Has Abstract

pub_date

2007-11-01 00:00:00

pages

1555-61

issue

11

eissn

0278-0062

issn

1558-254X

journal_volume

26

pub_type

杂志文章
  • Interactions Between Large-Scale Functional Brain Networks are Captured by Sparse Coupled HMMs.

    abstract::Functional magnetic resonance imaging (fMRI) provides a window on the human brain at work. Spontaneous brain activity measured during resting-state has already provided many insights into brain function. In particular, recent interest in dynamic interactions between brain regions has increased the need for more advanc...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2017.2755369

    authors: Bolton TAW,Tarun A,Sterpenich V,Schwartz S,Van De Ville D

    更新日期:2018-01-01 00:00:00

  • Self-Supervised Ultrasound to MRI Fetal Brain Image Synthesis.

    abstract::Fetal brain magnetic resonance imaging (MRI) offers exquisite images of the developing brain but is not suitable for second-trimester anomaly screening, for which ultrasound (US) is employed. Although expert sonographers are adept at reading US images, MR images which closely resemble anatomical images are much easier...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2020.3018560

    authors: Jiao J,Namburete AIL,Papageorghiou AT,Noble JA

    更新日期:2020-12-01 00:00:00

  • Restoration of signal polarity in a set of inversion recovery NMR images.

    abstract::A method is described which enables unambiguous retrieval of sign information in a set of magnetic resonance magnitude images of the inversion recovery type. The proposed method starts from the observation that the inversion recovery curve S is a monotonically increasing function of the inversion time TI, and comes do...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.1984.4307681

    authors: Bakker CG,De Graaf CN,Van Dijk P

    更新日期:1984-01-01 00:00:00

  • Graph-based multi-surface segmentation of OCT data using trained hard and soft constraints.

    abstract::Optical coherence tomography (OCT) is a well-established image modality in ophthalmology and used daily in the clinic. Automatic evaluation of such datasets requires an accurate segmentation of the retinal cell layers. However, due to the naturally low signal to noise ratio and the resulting bad image quality, this ta...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2012.2225152

    authors: Dufour PA,Ceklic L,Abdillahi H,Schröder S,De Dzanet S,Wolf-Schnurrbusch U,Kowal J

    更新日期:2013-03-01 00:00:00

  • Repeatability of linear and nonlinear elastic modulus maps from repeat scans in the breast.

    abstract::Compression elastography allows the precise measurement of large deformations of soft tissue in vivo. From an image sequence showing tissue undergoing large deformation, an inverse problem for both the linear and nonlinear elastic moduli distributions can be solved. As part of a larger clinical study to evaluate nonli...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2020.3036032

    authors: Gendin DI,Nayak R,Wang Y,Bayat M,Fazzio RT,Oberai AA,Hall TJ,Barbone PE,Alizad A,Fatemi M

    更新日期:2020-11-05 00:00:00

  • Semiautomated border tracking of cine echocardiographic ventnrcular images.

    abstract::Two-dimensional ultrasound sector scans of the left ventricle (LV) are commonly used to diagnose cardiac mechanical function. Present quantification procedures of wall motion by this technique entail inaccuracies, mainly due to relatively poor image quality and the absence of a definition of the relative position of t...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.1987.4307836

    authors: Adam D,Hareuveni O,Sideman S

    更新日期:1987-01-01 00:00:00

  • Globally convergent image reconstruction for emission tomography using relaxed ordered subsets algorithms.

    abstract::We present two types of globally convergent relaxed ordered subsets (OS) algorithms for penalized-likelihood image reconstruction in emission tomography: modified block sequential regularized expectation-maximization (BSREM) and relaxed OS separable paraboloidal surrogates (OS-SPS). The global convergence proof of the...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2003.812251

    authors: Ahn S,Fessler JA

    更新日期:2003-05-01 00:00:00

  • Segmentation of rodent whole-body dynamic PET images: an unsupervised method based on voxel dynamics.

    abstract::Positron emission tomography (PET) is a useful tool for pharmacokinetics studies in rodents during the preclinical phase of drug and tracer development. However, rodent organs are small as compared to the scanner's intrinsic resolution and are affected by physiological movements. We present a new method for the segmen...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2007.905106

    authors: Maroy R,Boisgard R,Comtat C,Frouin V,Cathier P,Duchesnay E,Dollé F,Nielsen PE,Trébossen R,Tavitian B

    更新日期:2008-03-01 00:00:00

  • Bidirectional Mapping-Based Domain Adaptation for Nucleus Detection in Cross-Modality Microscopy Images.

    abstract::Cell or nucleus detection is a fundamental task in microscopy image analysis and has recently achieved state-of-the-art performance by using deep neural networks. However, training supervised deep models such as convolutional neural networks (CNNs) usually requires sufficient annotated image data, which is prohibitive...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2020.3042789

    authors: Xing F,Cornish TC,Bennett TD,Ghosh D

    更新日期:2020-12-07 00:00:00

  • Computer-Aided Cervical Cancer Diagnosis Using Time-Lapsed Colposcopic Images.

    abstract::Cervical cancer causes the fourth most cancer-related deaths of women worldwide. Early detection of cervical intraepithelial neoplasia (CIN) can significantly increase the survival rate of patients. In this paper, we propose a deep learning framework for the accurate identification of LSIL+ (including CIN and cervical...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2020.2994778

    authors: Li Y,Chen J,Xue P,Tang C,Chang J,Chu C,Ma K,Li Q,Zheng Y,Qiao Y

    更新日期:2020-11-01 00:00:00

  • Application of active contours for photochromic tracer flow extraction.

    abstract::This paper addresses the implementation of image processing and computer vision techniques to automate tracer flow extraction in images obtained by the photochromic dye technique. This task is important in modeled arterial blood flow studies. Currently, it is performed via manual application of B-spline curve fitting....

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.585762

    authors: Androutsos D,Trahanias PE,Venetsanopoulos AN

    更新日期:1997-06-01 00:00:00

  • Accelerating the nonequispaced fast Fourier transform on commodity graphics hardware.

    abstract::We present a fast parallel algorithm to compute the nonequispaced fast Fourier transform on commodity graphics hardware (the GPU). We focus particularly on a novel implementation of the convolution step in the transform as it was previously its most time consuming part. We describe the performance for two common sampl...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2007.909834

    authors: Sorensen TS,Schaeffter T,Noe KO,Hansen MS

    更新日期:2008-04-01 00:00:00

  • Spatio-temporal nonrigid registration for ultrasound cardiac motion estimation.

    abstract::We propose a new spatio-temporal elastic registration algorithm for motion reconstruction from a series of images. The specific application is to estimate displacement fields from two-dimensional ultrasound sequences of the heart. The basic idea is to find a spatio-temporal deformation field that effectively compensat...

    journal_title:IEEE transactions on medical imaging

    pub_type: 临床试验,杂志文章

    doi:10.1109/TMI.2005.852050

    authors: Ledesma-Carbayo MJ,Kybic J,Desco M,Santos A,Sühling M,Hunziker P,Unser M

    更新日期:2005-09-01 00:00:00

  • The hypervolume under the ROC hypersurface of "near-guessing" and "near-perfect" observers in N-class classification tasks.

    abstract::We express the performance of the N-class "guessing" observer in terms of the N2-N conditional probabilities which make up an N-class receiver operating characteristic (ROC) space, in a formulation in which sensitivities are eliminated in constructing the ROC space (equivalent to using false-negative fraction and fals...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/tmi.2004.841227

    authors: Edwards DC,Metz CE,Nishikawa RM

    更新日期:2005-03-01 00:00:00

  • An investigation of methods of pileup rejection for 2-D array detectors employed in high resolution PET.

    abstract::Two methods of rejecting pileup events in 2-D array detectors used in positron emission tomography (PET) are investigated. Since the methods are based on different physical properties, they were investigated separately and in combination. Method one is based on the fact that valid events in the 2-D array detector occu...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.79481

    authors: Germano G,Hoffman EJ

    更新日期:1991-01-01 00:00:00

  • Imaging of cardiac movement using ratiometric and nonratiometric optical mapping: effects of ischemia and 2, 3-butaneodione monoxime.

    abstract::Transmembrane voltage-sensitive fluorescent dyes are used to study electrical activity in hearts. Green and red fluorescence emissions from di-4-ANEPPS excited with 488 nm light indicate both transmembrane voltage changes and heart movement. We have previously shown that the ratio, green fluorescence divided by red fl...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2005.861019

    authors: Himel HD 4th,Knisley SB

    更新日期:2006-01-01 00:00:00

  • Parameterization-invariant shape comparisons of anatomical surfaces.

    abstract::We consider 3-D brain structures as continuous parameterized surfaces and present a metric for their comparisons that is invariant to the way they are parameterized. Past comparisons of such surfaces involve either volume deformations or nonrigid matching under fixed parameterizations of surfaces. We propose a new mat...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2010.2099130

    authors: Kurtek S,Klassen E,Ding Z,Jacobson SW,Jacobson JL,Avison MJ,Srivastava A

    更新日期:2011-03-01 00:00:00

  • Classifying mammographic lesions using computerized image analysis.

    abstract::The classification of 3 common breast lesions, fibroadenomas, cysts, and cancers, was achieved using computerized image analysis of tumor shape in conjunction with patient age. The process involved the digitization of 69 mammographic images using a video camera and a commercial frame grabber on a PC-based computer sys...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.251116

    authors: Kilday J,Palmieri F,Fox MD

    更新日期:1993-01-01 00:00:00

  • Combined volumetric and surface registration.

    abstract::In this paper, we propose a novel method for the registration of volumetric images of the brain that optimizes the alignment of both cortical and subcortical structures. In order to achieve this, relevant geometrical information is extracted from a surface-based morph and diffused into the volume using the Navier oper...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2008.2004426

    authors: Postelnicu G,Zollei L,Fischl B

    更新日期:2009-04-01 00:00:00

  • Estimating CT Image From MRI Data Using Structured Random Forest and Auto-Context Model.

    abstract::Computed tomography (CT) imaging is an essential tool in various clinical diagnoses and radiotherapy treatment planning. Since CT image intensities are directly related to positron emission tomography (PET) attenuation coefficients, they are indispensable for attenuation correction (AC) of the PET images. However, due...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2015.2461533

    authors: Huynh T,Gao Y,Kang J,Wang L,Zhang P,Lian J,Shen D,Alzheimer's Disease Neuroimaging Initiative.

    更新日期:2016-01-01 00:00:00

  • Elastic registration in the presence of intensity variations.

    abstract::We have developed a general-purpose registration algorithm for medical images and volumes. This method models the transformation between images as locally affine but globally smooth. The model also explicitly accounts for local and global variations in image intensities. This approach is built upon a differential mult...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2003.815069

    authors: Periaswamy S,Farid H

    更新日期:2003-07-01 00:00:00

  • Prospective Respiration Detection in Magnetic Resonance Imaging by a Non-Interfering Noise Navigator.

    abstract::Passive monitoring of the thermal noise variances of the channels of a receive array was shown to reveal respiratory motion of the underlying anatomy, a so called "noise navigator". There is, however, an inevitable trade off between the accuracy and temporal resolution of the noise navigator due to its passive nature....

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2018.2808699

    authors: Navest RJM,Andreychenko A,Lagendijk JJW,van den Berg CAT

    更新日期:2018-08-01 00:00:00

  • MRI-compatible device for examining brain activation related to stepping.

    abstract::Repetitive and alternating lower limb movements are a specific component of human gait. Due to technical challenges, the neural mechanisms underlying such movements have not been previously studied with functional magnetic resonance imaging. In this study, we present a novel treadmill device employed to investigate th...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2014.2301493

    authors: Martinez M,Villagra F,Loayza F,Vidorreta M,Arrondo G,Luis E,Diaz J,Echeverria M,Fernandez-Seara MA,Pastor MA

    更新日期:2014-05-01 00:00:00

  • A high resolution PET for animal studies.

    abstract::In the PET system a block detector, which is a position-sensitive photomultiplier (PMT) tube coupled to four arrays of 1.7-mm-wide BGO crystals, is utilized. Fifteen block detectors are positioned to form a 35-cm-diameter ring, with four BGO arrays coupled to each PMT. This provides four detector rings, giving the sys...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.192694

    authors: Watanabe M,Uchida H,Okada H,Shimizu K,Satoh N,Yoshikawa E,Ohmura T,Yamashita T,Tanaka E

    更新日期:1992-01-01 00:00:00

  • Automated detection of prostatic adenocarcinoma from high-resolution ex vivo MRI.

    abstract::Prostatic adenocarcinoma is the most commonly occurring cancer among men in the United States, second only to skin cancer. Currently, the only definitive method to ascertain the presence of prostatic cancer is by trans-rectal ultrasound (TRUS) directed biopsy. Owing to the poor image quality of ultrasound, the accurac...

    journal_title:IEEE transactions on medical imaging

    pub_type: 临床试验,杂志文章

    doi:10.1109/TMI.2005.859208

    authors: Madabhushi A,Feldman MD,Metaxas DN,Tomaszeweski J,Chute D

    更新日期:2005-12-01 00:00:00

  • Burn depth analysis using multidimensional scaling applied to psychophysical experiment data.

    abstract::In this paper a psychophysical experiment and a multidimensional scaling (MDS) analysis are undergone to determine the physical characteristics that physicians employ to diagnose a burn depth. Subsequently, these characteristics are translated into mathematical features, correlated with these physical characteristics ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2013.2254719

    authors: Acha B,Serrano C,Fondón I,Gómez-Cía T

    更新日期:2013-06-01 00:00:00

  • Separation of Metabolites and Macromolecules for Short-TE 1H-MRSI Using Learned Component-Specific Representations.

    abstract::Short-echo-time (TE) proton magnetic resonance spectroscopic imaging (MRSI) allows for simultaneously mapping a number of molecules in the brain, and has been recognized as an important tool for studying in vivo biochemistry in various neuroscience and disease applications. However, separation of the metabolite and ma...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2020.3048933

    authors: Li Y,Wang Z,Sun R,Lam F

    更新日期:2021-01-04 00:00:00

  • GPU-based real-time volumetric ultrasound image reconstruction for a ring array.

    abstract::Synthetic phased array (SPA) beamforming with Hadamard coding and aperture weighting is an optimal option for real-time volumetric imaging with a ring array, a particularly attractive geometry in intracardiac and intravascular applications. However, the imaging frame rate of this method is limited by the immense compu...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2013.2253117

    authors: Choe JW,Nikoozadeh A,Oralkan O,Khuri-Yakub BT

    更新日期:2013-07-01 00:00:00

  • Unification of the inverse radon transform in odd and even dimensions.

    abstract::It is well known that the inverse radon transform exists in two forms for odd and even dimension functions, respectively. This note shows that these formulas become zero when the dimension requirement is violated, which results in a simple unified formula for the inverse radon transform of arbitrary dimensions. ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.476117

    authors: Liang ZP

    更新日期:1995-01-01 00:00:00

  • Computer Aided Theragnosis Using Quantitative Ultrasound Spectroscopy and Maximum Mean Discrepancy in Locally Advanced Breast Cancer.

    abstract::A noninvasive computer-aided-theragnosis (CAT) system was developed for the early therapeutic cancer response assessment in patients with locally advanced breast cancer (LABC) treated with neoadjuvant chemotherapy. The proposed CAT system was based on multi-parametric quantitative ultrasound (QUS) spectroscopic method...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2015.2495246

    authors: Gangeh MJ,Tadayyon H,Sannachi L,Sadeghi-Naini A,Tran WT,Czarnota GJ

    更新日期:2016-03-01 00:00:00