Burn depth analysis using multidimensional scaling applied to psychophysical experiment data.

Abstract:

:In this paper a psychophysical experiment and a multidimensional scaling (MDS) analysis are undergone to determine the physical characteristics that physicians employ to diagnose a burn depth. Subsequently, these characteristics are translated into mathematical features, correlated with these physical characteristics analysis. Finally, a study to verify the ability of these mathematical features to classify burns is performed. In this study, a space with axes correlated with the MDS axes has been developed. 74 images have been represented in this space and a k-nearest neighbor classifier has been used to classify these 74 images. A success rate of 66.2% was obtained when classifying burns into three burn depths and a success rate of 83.8% was obtained when burns were classified as those which needed grafts and those which did not. Additional studies have been performed comparing our system with a principal component analysis and a support vector machine classifier. Results validate the ability of the mathematical features extracted from the psychophysical experiment to classify burns into their depths. In addition, the method has been compared with another state-of-the-art method and the same database.

journal_name

IEEE Trans Med Imaging

authors

Acha B,Serrano C,Fondón I,Gómez-Cía T

doi

10.1109/TMI.2013.2254719

subject

Has Abstract

pub_date

2013-06-01 00:00:00

pages

1111-20

issue

6

eissn

0278-0062

issn

1558-254X

journal_volume

32

pub_type

杂志文章
  • Local phase tensor features for 3-D ultrasound to statistical shape+pose spine model registration.

    abstract::Most conventional spine interventions are performed under X-ray fluoroscopy guidance. In recent years, there has been a growing interest to develop nonionizing imaging alternatives to guide these procedures. Ultrasound guidance has emerged as a leading alternative. However, a challenging problem is automatic identific...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2014.2332571

    authors: Hacihaliloglu I,Rasoulian A,Rohling RN,Abolmaesumi P

    更新日期:2014-11-01 00:00:00

  • Artifact trapping during time reversal photoacoustic imaging for acoustically heterogeneous media.

    abstract::Several different reconstruction algorithms have been proposed for photoacoustic tomography, most of which presuppose that the acoustic properties of the medium are constant and homogeneous. In practice, there are often unknown spatial variations in the acoustic properties, and these algorithms give, at best, only app...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2009.2032358

    authors: Cox BT,Treeby BE

    更新日期:2010-02-01 00:00:00

  • Robust parameter estimation of intensity distributions for brain magnetic resonance images.

    abstract::This paper presents two new methods for robust parameter estimation of mixtures in the context of magnetic resonance (MR) data segmentation. The head is constituted of different types of tissue that can be modeled by a finite mixture of multivariate Gaussian distributions. Our goal is to estimate accurately the statis...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.700730

    authors: Schroeter P,Vesin JM,Langenberger T,Meuli R

    更新日期:1998-04-01 00:00:00

  • 2.5-D simultaneous multislice reconstruction by series expansion methods from Fourier-rebinned PET data.

    abstract::True three-dimensional (3-D) volume reconstruction from fully 3-D data in positron emission tomography (PET) has only a limited clinical use because of its large computational burden. Fourier rebinning (FORE) of the fully 3-D data into a set of 2-D sinogram data decomposes the 3-D reconstruction process into multiple ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.870257

    authors: Obi T,Matej S,Lewitt RM,Herman GT

    更新日期:2000-05-01 00:00:00

  • Fast and Accurate Rat Head Motion Tracking With Point Sources for Awake Brain PET.

    abstract::To avoid the confounding effects of anesthesia and immobilization stress in rat brain positron emission tomography (PET), motion tracking-based unrestrained awake rat brain imaging is being developed. In this paper, we propose a fast and accurate rat headmotion tracking method based on small PET point sources. PET poi...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2017.2667889

    authors: Miranda A,Staelens S,Stroobants S,Verhaeghe J

    更新日期:2017-07-01 00:00:00

  • Compressed Sensing Doppler Ultrasound Reconstruction Using Block Sparse Bayesian Learning.

    abstract::In this paper we propose a framework for using duplex Doppler ultrasound systems. These type of systems need to interleave the acquisition and display of a B-mode image and of the pulsed Doppler spectrogram. In a recent study (Richy , 2013), we have shown that compressed sensing-based reconstruction of Doppler signal ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2015.2504240

    authors: Lorintiu O,Liebgott H,Friboulet D

    更新日期:2016-04-01 00:00:00

  • Tracking pylorus in ultrasonic image sequences with edge-based optical flow.

    abstract::Tracking pylorus in ultrasonic image sequences is an important step in the analysis of duodenogastric reflux (DGR). We propose a joint prediction and segmentation method (JPS) which combines optical flow with active contour to track pylorus. The goal of the proposed method is to improve the pyloric tracking accuracy b...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2012.2183884

    authors: Chen C,Wang Y,Yu J,Zhou Z,Shen L,Chen Y

    更新日期:2012-03-01 00:00:00

  • In Vivo Measurement of Brain Tissue Response After Irradiation: Comparison of T2 Relaxation, Apparent Diffusion Coefficient, and Electrical Conductivity.

    abstract::Radiation therapy (RT) has been widely used as a powerful treatment tool to address cancerous tissues because of its ability to control cell growth. Its ionizing radiation damages the DNA of cancerous tissues, leading to cell death. Medical imaging, however, still has limitations regarding the reliability of its asses...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2019.2913766

    authors: Park JA,Kang KJ,Ko IO,Lee KC,Choi BK,Katoch N,Kim JW,Kim HJ,Kwon OI,Woo EJ

    更新日期:2019-12-01 00:00:00

  • REDMAPS: reduced-dimensionality matching for prostate brachytherapy seed reconstruction.

    abstract::The success of prostate brachytherapy critically depends on delivering adequate dose to the prostate gland. Intraoperative localization of the implanted seeds provides potential for dose evaluation and optimization during therapy. A reduced-dimensionality matching algorithm for prostate brachytherapy seed reconstructi...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2010.2059709

    authors: Lee J,Labat C,Jain AK,Song DY,Burdette EC,Fichtinger G,Prince JL

    更新日期:2011-01-01 00:00:00

  • Efficient Lattice Boltzmann Solver for Patient-Specific Radiofrequency Ablation of Hepatic Tumors.

    abstract::Radiofrequency ablation (RFA) is an established treatment for liver cancer when resection is not possible. Yet, its optimal delivery is challenged by the presence of large blood vessels and the time-varying thermal conductivity of biological tissue. Incomplete treatment and an increased risk of recurrence are therefor...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2015.2406575

    authors: Audigier C,Mansi T,Delingette H,Rapaka S,Mihalef V,Carnegie D,Boctor E,Choti M,Kamen A,Ayache N,Comaniciu D

    更新日期:2015-07-01 00:00:00

  • Classifying mammographic lesions using computerized image analysis.

    abstract::The classification of 3 common breast lesions, fibroadenomas, cysts, and cancers, was achieved using computerized image analysis of tumor shape in conjunction with patient age. The process involved the digitization of 69 mammographic images using a video camera and a commercial frame grabber on a PC-based computer sys...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.251116

    authors: Kilday J,Palmieri F,Fox MD

    更新日期:1993-01-01 00:00:00

  • Elevation direction deconvolution in three-dimensional ultrasound imaging.

    abstract::One-dimensional (1-D) linear transducer arrays can be used for three-dimensional (3-D) ultrasound image acquisition. However, the relatively low spatial resolution of these arrays in the elevation direction results in blurry 3-D images. Here, the authors introduce an elevation direction deconvolution (EDD) method that...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.500148

    authors: Wang X,Ritchie CJ,Kim Y

    更新日期:1996-01-01 00:00:00

  • A maximum a posteriori probability expectation maximization algorithm for image reconstruction in emission tomography.

    abstract::The expectation maximization method for maximum likelihood image reconstruction in emission tomography, based on the Poisson distribution of the statistically independent components of the image and measurement vectors, is extended to a maximum aposteriori image reconstruction using a multivariate Gaussian a priori pr...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.1987.4307826

    authors: Levitan E,Herman GT

    更新日期:1987-01-01 00:00:00

  • A nonparametric method for automatic correction of intensity nonuniformity in MRI data.

    abstract::A novel approach to correcting for intensity nonuniformity in magnetic resonance (MR) data is described that achieves high performance without requiring a model of the tissue classes present. The method has the advantage that it can be applied at an early stage in an automated data analysis, before a tissue model is a...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.668698

    authors: Sled JG,Zijdenbos AP,Evans AC

    更新日期:1998-02-01 00:00:00

  • Radiographic image sequence coding using two-stage adaptive vector quantization.

    abstract::A two-stage adaptive vector quantization scheme for radiographic image sequence coding is introduced. Each frame in the sequence is first decomposed into a set of vectors, corresponding to nonoverlapping spatially contiguous block of pixels. A codebook is generated using a training set of vectors drawn from the sequen...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.3938

    authors: Sun H,Goldberg M

    更新日期:1988-01-01 00:00:00

  • Automatic correction of motion artifacts in magnetic resonance images using an entropy focus criterion.

    abstract::We present the use of an entropy focus criterion to enable automatic focusing of motion corrupted magnetic resonance images. We demonstrate the principle using illustrative examples from cooperative volunteers. Our technique can determine unknown patient motion or use knowledge of motion from other measures as a start...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.650886

    authors: Atkinson D,Hill DL,Stoyle PN,Summers PE,Keevil SF

    更新日期:1997-12-01 00:00:00

  • Selection of a convolution function for Fourier inversion using gridding [computerised tomography application].

    abstract::In the technique known as gridding, the data samples are weighted for sampling density and convolved with a finite kernel, then resampled on a grid preparatory to a fast Fourier transform. The authors compare the artifact introduced into the image for various convolving functions of different sizes, including the Kais...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.97598

    authors: Jackson JI,Meyer CH,Nishimura DG,Macovski A

    更新日期:1991-01-01 00:00:00

  • Automated detection of prostatic adenocarcinoma from high-resolution ex vivo MRI.

    abstract::Prostatic adenocarcinoma is the most commonly occurring cancer among men in the United States, second only to skin cancer. Currently, the only definitive method to ascertain the presence of prostatic cancer is by trans-rectal ultrasound (TRUS) directed biopsy. Owing to the poor image quality of ultrasound, the accurac...

    journal_title:IEEE transactions on medical imaging

    pub_type: 临床试验,杂志文章

    doi:10.1109/TMI.2005.859208

    authors: Madabhushi A,Feldman MD,Metaxas DN,Tomaszeweski J,Chute D

    更新日期:2005-12-01 00:00:00

  • Application of active contours for photochromic tracer flow extraction.

    abstract::This paper addresses the implementation of image processing and computer vision techniques to automate tracer flow extraction in images obtained by the photochromic dye technique. This task is important in modeled arterial blood flow studies. Currently, it is performed via manual application of B-spline curve fitting....

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.585762

    authors: Androutsos D,Trahanias PE,Venetsanopoulos AN

    更新日期:1997-06-01 00:00:00

  • Nonrigid motion modeling of the liver from 3-D undersampled self-gated golden-radial phase encoded MRI.

    abstract::Magnetic resonance imaging (MRI) has been commonly used for guiding and planning image guided interventions since it provides excellent soft tissue visualization of anatomy and allows motion modeling to predict the position of target tissues during the procedure. However, MRI-based motion modeling remains challenging ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2011.2181997

    authors: Buerger C,Clough RE,King AP,Schaeffter T,Prieto C

    更新日期:2012-03-01 00:00:00

  • Compressed Sensing Reconstruction of 3D Ultrasound Data Using Dictionary Learning and Line-Wise Subsampling.

    abstract::In this paper we present a compressed sensing (CS) method adapted to 3D ultrasound imaging (US). In contrast to previous work, we propose a new approach based on the use of learned overcomplete dictionaries that allow for much sparser representations of the signals since they are optimized for a particular class of im...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2015.2442154

    authors: Lorintiu O,Liebgott H,Alessandrini M,Bernard O,Friboulet D

    更新日期:2015-12-01 00:00:00

  • Keypoint Transfer for Fast Whole-Body Segmentation.

    abstract::We introduce an approach for image segmentation based on sparse correspondences between keypoints in testing and training images. Keypoints represent automatically identified distinctive image locations, where each keypoint correspondence suggests a transformation between images. We use these correspondences to transf...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2018.2851194

    authors: Wachinger C,Toews M,Langs G,Wells W,Golland P

    更新日期:2020-02-01 00:00:00

  • Mobile Biplane X-Ray Imaging System for Measuring 3D Dynamic Joint Motion During Overground Gait.

    abstract::Most X-ray fluoroscopy systems are stationary and impose restrictions on the measurement of dynamic joint motion; for example, knee-joint kinematics during gait is usually measured with the subject ambulating on a treadmill. We developed a computer-controlled, mobile, biplane, X-ray fluoroscopy system to track human b...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2015.2473168

    authors: Guan S,Gray HA,Keynejad F,Pandy MG

    更新日期:2016-01-01 00:00:00

  • Differentiation and characterization of rat mammary fibroadenomas and 4T1 mouse carcinomas using quantitative ultrasound imaging.

    abstract::Scatterer properties like the average effective scatterer diameter and acoustic concentration were determined in vivo using a quantitative ultrasound (QUS) technique from two tumor phenotypes grown in animal models. These tumor models included spontaneously occurring mammary fibroadenomas in rats and transplanted 4T1 ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/tmi.2004.826953

    authors: Oelze ML,O'Brien WD Jr,Blue JP,Zachary JF

    更新日期:2004-06-01 00:00:00

  • Ultrafast Doppler imaging of blood flow dynamics in the myocardium.

    abstract::Imaging intramyocardial vascular flows in real-time could strongly help to achieve better diagnostic of cardiovascular diseases. To date, no standard imaging modality allows describing accurately myocardial blood flow dynamics with good spatial and temporal resolution. We recently introduced a novel ultrasonic Doppler...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2012.2203316

    authors: Osmanski BF,Pernot M,Montaldo G,Bel A,Messas E,Tanter M

    更新日期:2012-08-01 00:00:00

  • Computer-aided stereotactic functional neurosurgery enhanced by the use of the multiple brain atlas database.

    abstract::This paper introduces a computer-aided atlas-based functional neurosurgery methodology and describes NeuroPlanner, a software system which supports it. NeuroPlanner provides four groups of functions: 1) data-related for data reading, interpolation, reformatting, and image processing; 2) atlas-related for multiple atla...

    journal_title:IEEE transactions on medical imaging

    pub_type: 信件

    doi:10.1109/42.832961

    authors: Nowinski WL,Yang GL,Yeo TT

    更新日期:2000-01-01 00:00:00

  • Simultaneous Quantitative Imaging of Electrical Properties and Proton Density From B1 Maps Using MRI.

    abstract::Electrical conductivity and permittivity of biological tissues are important diagnostic parameters and are useful for calculating subject-specific specific absorption rate distribution. On the other hand, water proton density also has clinical relevance for diagnosis purposes. These two kinds of tissue properties are ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2016.2547988

    authors: Jiaen Liu,Van de Moortele PF,Xiaotong Zhang,Yicun Wang,Bin He

    更新日期:2016-09-01 00:00:00

  • In situ characterization of the degradation of PLGA microspheres in hyaluronic acid hydrogels by optical coherence tomography.

    abstract::The polymeric implant material poly(lactide-co-glycolide) (PLGA) degrades by a process of bulk degradation, which allows it to be used for the controlled release of therapeutic molecules from implants and microspheres. The temporal characterization of PLGA microsphere degradation has been limited by the need to destru...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2008.927356

    authors: Patterson J,Stayton PS,Li X

    更新日期:2009-01-01 00:00:00

  • A Generalized Correlation-Based Model for Out-of-Plane Motion Estimation in Freehand Ultrasound.

    abstract::A big challenge in sensorless image-based ultrasound tracking is in the out-of-plane motion estimation. The correlation value of a specific model of speckle known as fully developed speckle (FDS) can be used to estimate the out-of-plane displacement. In real tissue, this kind of pattern is rare and the deviation of sp...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2013.2283969

    authors: Afsham N,Najafi M,Abolmaesumi P,Rohling R

    更新日期:2014-01-01 00:00:00

  • Magnetic Particle Imaging: A Resovist Based Marking Technology for Guide Wires and Catheters for Vascular Interventions.

    abstract::Magnetic particle imaging (MPI) is able to provide high temporal and good spatial resolution, high signal to noise ratio and sensitivity. Furthermore, it is a truly quantitative method as its signal strength is proportional to the concentration of its tracer, superparamagnetic iron oxide nanoparticles (SPIOs), over a ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2016.2559538

    authors: Haegele J,Panagiotopoulos N,Cremers S,Rahmer J,Franke J,Duschka RL,Vaalma S,Heidenreich M,Borgert J,Borm P,Barkhausen J,Vogt FM

    更新日期:2016-10-01 00:00:00