Improving Registration Robustness for Image-Guided Liver Surgery in a Novel Human-to-Phantom Data Framework.

Abstract:

:In open image-guided liver surgery (IGLS), a sparse representation of the intraoperative organ surface can be acquired to drive image-to-physical registration. We hypothesize that uncharacterized error induced by variation in the collection patterns of organ surface data limits the accuracy and robustness of an IGLS registration. Clinical validation of such registration methods is challenged due to the difficulty in obtaining data representative of the true state of organ deformation. We propose a novel human-to-phantom validation framework that transforms surface collection patterns from in vivo IGLS procedures (n = 13) onto a well-characterized hepatic deformation phantom for the purpose of validating surface-driven, volumetric nonrigid registration methods. An important feature of the approach is that it centers on combining workflow-realistic data acquisition and surgical deformations that are appropriate in behavior and magnitude. Using the approach, we investigate volumetric target registration error (TRE) with both current rigid IGLS and our improved nonrigid registration methods. Additionally, we introduce a spatial data resampling approach to mitigate the workflow-sensitive sampling problem. Using our human-to-phantom approach, TRE after routine rigid registration was 10.9 ± 0.6 mm with a signed closest point distance associated with residual surface fit in the range of ±10 mm, highly representative of open liver resections. After applying our novel resampling strategy and improved deformation correction method, TRE was reduced by 51%, i.e., a TRE of 5.3 ± 0.5 mm. This paper reported herein realizes a novel tractable approach for the validation of image-to-physical registration methods and demonstrates promising results for our correction method.

journal_name

IEEE Trans Med Imaging

authors

Collins JA,Weis JA,Heiselman JS,Clements LW,Simpson AL,Jarnagin WR,Miga MI

doi

10.1109/TMI.2017.2668842

subject

Has Abstract

pub_date

2017-07-01 00:00:00

pages

1502-1510

issue

7

eissn

0278-0062

issn

1558-254X

journal_volume

36

pub_type

杂志文章
  • Wavelet analysis for brain-function imaging.

    abstract::The authors present a new algorithmic procedure for the analysis of brain images. This procedure is specifically designed to image the activity and functional organization of the brain. The authors' results are tested on data collected and previously analyzed with the technique known as in vivo optical imaging of intr...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.414621

    authors: Carmona RA,Hwang WL,Frostig RD

    更新日期:1995-01-01 00:00:00

  • PVR: Patch-to-Volume Reconstruction for Large Area Motion Correction of Fetal MRI.

    abstract::In this paper, we present a novel method for the correction of motion artifacts that are present in fetal magnetic resonance imaging (MRI) scans of the whole uterus. Contrary to current slice-to-volume registration (SVR) methods, requiring an inflexible anatomical enclosure of a single investigated organ, the proposed...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2017.2737081

    authors: Alansary A,Rajchl M,McDonagh SG,Murgasova M,Damodaram M,Lloyd DFA,Davidson A,Rutherford M,Hajnal JV,Rueckert D,Kainz B

    更新日期:2017-10-01 00:00:00

  • Sparse-view spectral CT reconstruction using spectral patch-based low-rank penalty.

    abstract::Spectral computed tomography (CT) is a promising technique with the potential for improving lesion detection, tissue characterization, and material decomposition. In this paper, we are interested in kVp switching-based spectral CT that alternates distinct kVp X-ray transmissions during gantry rotation. This system can...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2014.2380993

    authors: Kim K,Ye JC,Worstell W,Ouyang J,Rakvongthai Y,El Fakhri G,Li Q

    更新日期:2015-03-01 00:00:00

  • Difference-Frequency Ultrasound Imaging With Non-Linear Contrast.

    abstract::Conventional ultrasound imaging is based on the scattering of sound from inhomogeneities in the density and the speed of sound and is often used in medicine to resolve pathologic compared to normal tissue. Here we demonstrate a difference-frequency ultrasound (dfUS) imaging method that is based on the interaction of t...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2019.2957280

    authors: Li Y,Polyak D,Johnson E,Yecies D,Shevidi S,de la Zerda A,Gephart MH,Chu S

    更新日期:2020-05-01 00:00:00

  • Improved Sensitivity in Ultrasound Molecular Imaging With Coherence-Based Beamforming.

    abstract::Ultrasound molecular imaging (USMI) is accomplished by detecting microbubble (MB) contrast agents that have bound to specific biomarkers, and can be used for a variety of imaging applications, such as the early detection of cancer. USMI has been widely utilized in preclinical imaging in mice; however, USMI in humans c...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2017.2774814

    authors: Hyun D,Abou-Elkacem L,Perez VA,Chowdhury SM,Willmann JK,Dahl JJ

    更新日期:2018-01-01 00:00:00

  • On Bayesian image reconstruction from projections: uniform and nonuniform a priori source information.

    abstract::A method that incorporates a priori uniform or nonuniform source distribution probabilistic information and data fluctuations of a Poisson nature is presented. The source distributions are modeled in terms of a priori source probability density functions. Maximum a posteriori probability solutions, as determined by a ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.34711

    authors: Liang Z,Jaszczak R,Greer K

    更新日期:1989-01-01 00:00:00

  • Framework for Photon Counting Quantitative Material Decomposition.

    abstract::In this paper, the accuracy of material decomposition (MD) using an energy discriminating photon counting detector was studied. An MD framework was established and validated using calcium hydroxyapatite (CaHA) inserts of known densities (50 mg/cm3, 100 mg/cm3, 250 mg/cm3, 400 mg/cm3), and diameters (1.2, 3.0, and 5.0 ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2019.2914370

    authors: Juntunen MAK,Inkinen SI,Ketola JH,Kotiaho A,Kauppinen M,Winkler A,Nieminen MT

    更新日期:2020-01-01 00:00:00

  • Measures of acutance and shape for classification of breast tumors.

    abstract::Most benign breast tumors possess well-defined, sharp boundaries that delineate them from surrounding tissues, as opposed to malignant tumors. Computer techniques proposed to date for tumor analysis have concentrated on shape factors of tumor regions and texture measures. While shape measures based on contours of tumo...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.650876

    authors: Rangayyan RM,El-Faramawy NM,Desautels JE,Alim OA

    更新日期:1997-12-01 00:00:00

  • Edge displacement field-based classification for improved detection of polyps in CT colonography.

    abstract::Colorectal cancer can easily be prevented provided that the precursors to tumors, small colonic polyps, are detected and removed. Currently, the only definitive examination of the colon is fiber-optic colonoscopy, which is invasive and expensive. Computed tomographic colonography (CTC) is potentially a less costly and...

    journal_title:IEEE transactions on medical imaging

    pub_type: 临床试验,杂志文章

    doi:10.1109/TMI.2002.806405

    authors: Acar B,Beaulieu CF,Göktürk SB,Tomasi C,Paik DS,Jeffrey RB Jr,Yee J,Napel S

    更新日期:2002-12-01 00:00:00

  • Unsupervised Deep Learning Applied to Breast Density Segmentation and Mammographic Risk Scoring.

    abstract::Mammographic risk scoring has commonly been automated by extracting a set of handcrafted features from mammograms, and relating the responses directly or indirectly to breast cancer risk. We present a method that learns a feature hierarchy from unlabeled data. When the learned features are used as the input to a simpl...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2016.2532122

    authors: Kallenberg M,Petersen K,Nielsen M,Ng AY,Pengfei Diao,Igel C,Vachon CM,Holland K,Winkel RR,Karssemeijer N,Lillholm M

    更新日期:2016-05-01 00:00:00

  • Robust simultaneous detection of coronary borders in complex images.

    abstract::Visual estimation of coronary obstruction severity from angiograms suffers from poor inter- and intraobserver reproducibility and is often inaccurate. In spite of the widely recognized limitations of visual analysis, automated methods have not found widespread clinical use, in part because they too frequently fail to ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.370412

    authors: Sonka M,Winniford MD,Collins SM

    更新日期:1995-01-01 00:00:00

  • Burn depth analysis using multidimensional scaling applied to psychophysical experiment data.

    abstract::In this paper a psychophysical experiment and a multidimensional scaling (MDS) analysis are undergone to determine the physical characteristics that physicians employ to diagnose a burn depth. Subsequently, these characteristics are translated into mathematical features, correlated with these physical characteristics ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2013.2254719

    authors: Acha B,Serrano C,Fondón I,Gómez-Cía T

    更新日期:2013-06-01 00:00:00

  • Joint Multi-Modal Longitudinal Regression and Classification for Alzheimer's Disease Prediction.

    abstract::Alzheimer's disease (AD) is a serious neurodegenerative condition that affects millions of individuals across the world. As the average age of individuals in the United States and the world increases, the prevalence of AD will continue to grow. To address this public health problem, the research community has develope...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2019.2958943

    authors: Brand L,Nichols K,Wang H,Shen L,Huang H

    更新日期:2020-06-01 00:00:00

  • An Improved Method of Total Variation Superiorization Applied to Reconstruction in Proton Computed Tomography.

    abstract::Previous work has shown that total variation superiorization (TVS) improves reconstructed image quality in proton computed tomography (pCT). The structure of the TVS algorithm has evolved since then and this paper investigated if this new algorithmic structure provides additional benefits to pCT image quality. Structu...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2019.2911482

    authors: Schultze B,Censor Y,Karbasi P,Schubert KE,Schulte RW

    更新日期:2020-02-01 00:00:00

  • Virtual tagging: numerical considerations and phantom validation.

    abstract::This paper presents a virtual tagging framework for measuring, as well as visualising, myocardial deformation using magnetic resonance (MR) velocity imaging. Tagging grids are allocated artificially according to the deformation gradient with varying shapes and densities. The control points are then deformed such that ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2002.804429

    authors: Masood S,Gao J,Yang GZ

    更新日期:2002-09-01 00:00:00

  • A Tensor B-Spline Approach for Solving the Diffusion PDE With Application to Optical Diffusion Tomography.

    abstract::Optical Diffusion Tomography (ODT) is a modern non-invasive medical imaging modality which requires mathematical modelling of near-infrared light propagation in tissue. Solving the ODT forward problem equation accurately and efficiently is crucial. Typically, the forward problem is represented by a Diffusion PDE and i...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2016.2641500

    authors: Shulga D,Morozov O,Hunziker P

    更新日期:2017-04-01 00:00:00

  • Accuracy of in vivo neuroreceptor quantification by PET and review of steady-state, transient, double injection, and equilibrium models.

    abstract::The accuracy of in vivo dopamine D2 receptor quantification by positron emission tomography (PET) was determined for several models by means of singular-value decomposition, and some of the model assumptions were reviewed. These include steady-state, transient, double injection, and equilibrium approaches. All four mo...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.7783

    authors: Zeeberg BR,Gibson RE,Reba RC

    更新日期:1988-01-01 00:00:00

  • The n-PI-method for helical cone-beam CT.

    abstract::A new class of acquisition schemes for helical cone-beam computed tomography (CB-CT) scanning is introduced, and their effect on the reconstruction methods is analyzed. These acquisition schemes are based on a new detector shape that is bounded by the helix. It will be shown that the data acquired with these schemes a...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.887834

    authors: Proksa R,Köhler T,Grass M,Timmer J

    更新日期:2000-09-01 00:00:00

  • Fractal feature analysis and classification in medical imaging.

    abstract::Following B.B. Mandelbrot's fractal theory (1982), it was found that the fractal dimension could be obtained in medical images by the concept of fractional Brownian motion. An estimation concept for determination of the fractal dimension based upon the concept of fractional Brownian motion is discussed. Two applicatio...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.24861

    authors: Chen CC,Daponte JS,Fox MD

    更新日期:1989-01-01 00:00:00

  • A methodology for evaluation of boundary detection algorithms on medical images.

    abstract::Image segmentation is the partition of an image into a set of nonoverlapping regions whose union is the entire image. The image is decomposed into meaningful parts which are uniform with respect to certain characteristics, such as gray level or texture. In this paper, we propose a methodology for evaluating medical im...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.640755

    authors: Chalana V,Kim Y

    更新日期:1997-10-01 00:00:00

  • Statistical distributions of DCT coefficients and their application to an interframe compression algorithm for 3-D medical images.

    abstract::Displacement estimated interframe (DEI) coding, a coding scheme for 3-D medical image data sets such as X-ray computed tomography (CT) or magnetic resonance (MR) images, is presented. To take advantage of the correlation between contiguous slices, a displacement-compensated difference image based on the previous image...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.241875

    authors: Lee H,Kim Y,Rowberg AH,Riskin EA

    更新日期:1993-01-01 00:00:00

  • Prostate Cancer Detection Using Composite Impedance Metric.

    abstract::Prostate cancer (PCa) recurrences are often predicted by assessing the status of surgical margins (SM)- positive surgical margins (PSM) increase the chances of biochemical recurrence by 2-4 times which may lead to PCa recurrence. To this end, an electrical impedance acquisition system with a microendoscopic probe was ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2016.2578939

    authors: Khan S,Mahara A,Hyams ES,Schned AR,Halter RJ

    更新日期:2016-12-01 00:00:00

  • Bidirectional Mapping-Based Domain Adaptation for Nucleus Detection in Cross-Modality Microscopy Images.

    abstract::Cell or nucleus detection is a fundamental task in microscopy image analysis and has recently achieved state-of-the-art performance by using deep neural networks. However, training supervised deep models such as convolutional neural networks (CNNs) usually requires sufficient annotated image data, which is prohibitive...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2020.3042789

    authors: Xing F,Cornish TC,Bennett TD,Ghosh D

    更新日期:2020-12-07 00:00:00

  • Practical considerations for 3-D image reconstruction using spherically symmetric volume elements.

    abstract::Spherically symmetric volume elements with smooth tapering of the values near their boundaries are alternatives to the more conventional voxels for the construction of volume images in the computer. Their use, instead of voxels, introduces additional parameters which enable the user to control the shape of the volume ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.481442

    authors: Matej S,Lewitt RM

    更新日期:1996-01-01 00:00:00

  • Hot spot detection based on feature space representation of visual search.

    abstract::This paper presents a new framework for capturing intrinsic visual search behavior of different observers in image understanding by analysing saccadic eye movements in feature space. The method is based on the information theory for identifying salient image features based on which visual search is performed. We demon...

    journal_title:IEEE transactions on medical imaging

    pub_type: 临床试验,杂志文章

    doi:10.1109/TMI.2003.816959

    authors: Hu XP,Dempere-Marco L,Yang GZ

    更新日期:2003-09-01 00:00:00

  • Cap-Based Transcranial Optical Tomography in an Awake Infant.

    abstract::Although Blood Oxygenation Level Dependent (BOLD) functional MRI (fMRI) is widely used to examine brain function in adults, the need for general anesthesia limits its practical utility in infants and small children. Functional Near-Infrared Spectroscopy - Diffuse Optical Tomography (fNIRS-DOT) imaging promises to be a...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2020.2990823

    authors: Zhu B,Sevick-Muraca EM,Nguyen RD,Shah MN

    更新日期:2020-11-01 00:00:00

  • Intensity-based image registration using robust correlation coefficients.

    abstract::The ordinary sample correlation coefficient is a popular similarity measure for aligning images from the same or similar modalities. However, this measure can be sensitive to the presence of "outlier" objects that appear in one image but not the other, such as surgical instruments, the patient table, etc., which can l...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2004.835313

    authors: Kim J,Fessler JA

    更新日期:2004-11-01 00:00:00

  • Shortest path refinement for motion estimation from tagged MR images.

    abstract::Magnetic resonance tagging makes it possible to measure the motion of tissues such as muscles in the heart and tongue. The harmonic phase (HARP) method largely automates the process of tracking points within tagged MR images, permitting many motion properties to be computed. However, HARP tracking can yield erroneous ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2010.2045509

    authors: Liu X,Prince JL

    更新日期:2010-08-01 00:00:00

  • Single and multipinhole collimator design evaluation method for small animal SPECT.

    abstract::High-resolution functional imaging of small animals is often obtained by single pinhole SPECT with circular orbit acquisition. Multipinhole SPECT adds information due to its improved sampling, and can improve the trade-off between resolution and sensitivity. To evaluate different pinhole collimator designs an efficien...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2007.902802

    authors: Vunckx K,Beque D,Defrise M,Nuyts J

    更新日期:2008-01-01 00:00:00

  • Multi-scale tubular structure detection in ultrasound imaging.

    abstract::We propose a novel, physics-based method for detecting multi-scale tubular features in ultrasound images. The detector is based on a Hessian-matrix eigenvalue method, but unlike previous work, our detector is guided by an optimal model of vessel-like structures with respect to the ultrasound-image formation process. O...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2014.2340912

    authors: Hennersperger C,Baust M,Waelkens P,Karamalis A,Ahmadi SA,Navab N

    更新日期:2015-01-01 00:00:00