Wavelet coding of volumetric medical datasets.

Abstract:

:Several techniques based on the three-dimensional (3-D) discrete cosine transform (DCT) have been proposed for volumetric data coding. These techniques fail to provide lossless coding coupled with quality and resolution scalability, which is a significant drawback for medical applications. This paper gives an overview of several state-of-the-art 3-D wavelet coders that do meet these requirements and proposes new compression methods exploiting the quadtree and block-based coding concepts, layered zero-coding principles, and context-based arithmetic coding. Additionally, a new 3-D DCT-based coding scheme is designed and used for benchmarking. The proposed wavelet-based coding algorithms produce embedded data streams that can be decoded up to the lossless level and support the desired set of functionality constraints. Moreover, objective and subjective quality evaluation on various medical volumetric datasets shows that the proposed algorithms provide competitive lossy and lossless compression results when compared with the state-of-the-art.

journal_name

IEEE Trans Med Imaging

authors

Schelkens P,Munteanu A,Barbarien J,Galca M,Giro-Nieto X,Cornelis J

doi

10.1109/tmi.2003.809582

subject

Has Abstract

pub_date

2003-03-01 00:00:00

pages

441-58

issue

3

eissn

0278-0062

issn

1558-254X

journal_volume

22

pub_type

杂志文章
  • Mobile Biplane X-Ray Imaging System for Measuring 3D Dynamic Joint Motion During Overground Gait.

    abstract::Most X-ray fluoroscopy systems are stationary and impose restrictions on the measurement of dynamic joint motion; for example, knee-joint kinematics during gait is usually measured with the subject ambulating on a treadmill. We developed a computer-controlled, mobile, biplane, X-ray fluoroscopy system to track human b...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2015.2473168

    authors: Guan S,Gray HA,Keynejad F,Pandy MG

    更新日期:2016-01-01 00:00:00

  • An efficient optimization framework for multi-region segmentation based on Lagrangian duality.

    abstract::We introduce a multi-region model for simultaneous segmentation of medical images. In contrast to many other models, geometric constraints such as inclusion and exclusion between the regions are enforced, which makes it possible to correctly segment different regions even if the intensity distributions are identical. ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2012.2218117

    authors: Ulén J,Strandmark P,Kahl F

    更新日期:2013-02-01 00:00:00

  • Comb-push ultrasound shear elastography (CUSE): a novel method for two-dimensional shear elasticity imaging of soft tissues.

    abstract::Fast and accurate tissue elasticity imaging is essential in studying dynamic tissue mechanical properties. Various ultrasound shear elasticity imaging techniques have been developed in the last two decades. However, to reconstruct a full field-of-view 2-D shear elasticity map, multiple data acquisitions are typically ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2012.2205586

    authors: Song P,Zhao H,Manduca A,Urban MW,Greenleaf JF,Chen S

    更新日期:2012-09-01 00:00:00

  • Renal Segmentation From 3D Ultrasound via Fuzzy Appearance Models and Patient-Specific Alpha Shapes.

    abstract::Ultrasound (US) imaging is the primary imaging modality for pediatric hydronephrosis, which manifests as the dilation of the renal collecting system (CS). In this paper, we present a new framework for the segmentation of renal structures, kidney and CS, from 3DUS scans. First, the kidney is segmented using an active s...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2016.2572641

    authors: Cerrolaza JJ,Safdar N,Biggs E,Jago J,Peters CA,Linguraru MG

    更新日期:2016-11-01 00:00:00

  • Parametric estimate of intensity inhomogeneities applied to MRI.

    abstract::This paper presents a new approach to the correction of intensity inhomogeneities in magnetic resonance imaging (MRI) that significantly improves intensity-based tissue segmentation. The distortion of the image brightness values by a low-frequency bias field impedes visual inspection and segmentation. The new correcti...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.845174

    authors: Styner M,Brechbühler C,Székely G,Gerig G

    更新日期:2000-03-01 00:00:00

  • Tomographic fluorescence imaging in tissue phantoms: a novel reconstruction algorithm and imaging geometry.

    abstract::A novel image reconstruction algorithm has been developed and demonstrated for fluorescence-enhanced frequency-domain photon migration (FDPM) tomography from measurements of area illumination with modulated excitation light and area collection of emitted fluorescence light using a gain modulated image-intensified char...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/tmi.2004.839359

    authors: Roy R,Thompson AB,Godavarty A,Sevick-Muraca EM

    更新日期:2005-02-01 00:00:00

  • Segmentation of rodent whole-body dynamic PET images: an unsupervised method based on voxel dynamics.

    abstract::Positron emission tomography (PET) is a useful tool for pharmacokinetics studies in rodents during the preclinical phase of drug and tracer development. However, rodent organs are small as compared to the scanner's intrinsic resolution and are affected by physiological movements. We present a new method for the segmen...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2007.905106

    authors: Maroy R,Boisgard R,Comtat C,Frouin V,Cathier P,Duchesnay E,Dollé F,Nielsen PE,Trébossen R,Tavitian B

    更新日期:2008-03-01 00:00:00

  • Stratified Decision Forests for Accurate Anatomical Landmark Localization in Cardiac Images.

    abstract::Accurate localization of anatomical landmarks is an important step in medical imaging, as it provides useful prior information for subsequent image analysis and acquisition methods. It is particularly useful for initialization of automatic image analysis tools (e.g. segmentation and registration) and detection of scan...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2016.2597270

    authors: Oktay O,Bai W,Guerrero R,Rajchl M,de Marvao A,O'Regan DP,Cook SA,Heinrich MP,Glocker B,Rueckert D

    更新日期:2017-01-01 00:00:00

  • Unsupervised Domain Adaptation from Axial to Short-Axis Multi-Slice Cardiac MR Images by Incorporating Pretrained Task Networks.

    abstract::Anisotropic multi-slice Cardiac Magnetic Resonance (CMR) Images are conventionally acquired in patient-specific short-axis (SAX) orientation. In specific cardiovascular diseases that affect right ventricular (RV) morphology, acquisitions in standard axial (AX) orientation are preferred by some investigators, due to po...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2021.3052972

    authors: Koehler S,Hussain T,Blair Z,Huffaker T,Ritzmann F,Tandon A,Pickardt T,Sarikouch S,Sarikouch S,Latus H,Greil G,Wolf I,Engelhardt S

    更新日期:2021-01-20 00:00:00

  • Framing U-Net via Deep Convolutional Framelets: Application to Sparse-View CT.

    abstract::X-ray computed tomography (CT) using sparse projection views is a recent approach to reduce the radiation dose. However, due to the insufficient projection views, an analytic reconstruction approach using the filtered back projection (FBP) produces severe streaking artifacts. Recently, deep learning approaches using l...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2018.2823768

    authors: Han Y,Ye JC

    更新日期:2018-06-01 00:00:00

  • A proof of the spherical homeomorphism conjecture for surfaces.

    abstract::The human cerebral cortex is topologically equivalent to a sphere when it is viewed as closed at the brain stem. Due to noise and/or resolution issues, magnetic resonance imaging may see "handles" that need to be eliminated to reflect the true spherical topology. Shattuck and Leahy present an algorithm to correct such...

    journal_title:IEEE transactions on medical imaging

    pub_type: 评论,信件

    doi:10.1109/TMI.2002.806590

    authors: Abrams L,Fishkind DE,Priebe CE

    更新日期:2002-12-01 00:00:00

  • Unsupervised Myocardial Segmentation for Cardiac BOLD.

    abstract::A fully automated 2-D+time myocardial segmentation framework is proposed for cardiac magnetic resonance (CMR) blood-oxygen-level-dependent (BOLD) data sets. Ischemia detection with CINE BOLD CMR relies on spatio-temporal patterns in myocardial intensity, but these patterns also trouble supervised segmentation methods,...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2017.2726112

    authors: Oksuz I,Mukhopadhyay A,Dharmakumar R,Tsaftaris SA

    更新日期:2017-11-01 00:00:00

  • Vulnerable atherosclerotic plaque elasticity reconstruction based on a segmentation-driven optimization procedure using strain measurements: theoretical framework.

    abstract::It is now recognized that prediction of the vulnerable coronary plaque rupture requires not only an accurate quantification of fibrous cap thickness and necrotic core morphology but also a precise knowledge of the mechanical properties of plaque components. Indeed, such knowledge would allow a precise evaluation of th...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2009.2012852

    authors: Le Floc'h S,Ohayon J,Tracqui P,Finet G,Gharib AM,Maurice RL,Cloutier G,Pettigrew RI

    更新日期:2009-07-01 00:00:00

  • Multiobjective genetic optimization of diagnostic classifiers with implications for generating receiver operating characteristic curves.

    abstract::It is well understood that binary classifiers have two implicit objective functions (sensitivity and specificity) describing their performance. Traditional methods of classifier training attempt to combine these two objective functions (or two analogous class performance measures) into one so that conventional scalar ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.796281

    authors: Kupinski MA,Anastasio MA

    更新日期:1999-08-01 00:00:00

  • Amplified Flow Imaging (aFlow): A Novel MRI-Based Tool to Unravel the Coupled Dynamics Between the Human Brain and Cerebrovasculature.

    abstract::With each heartbeat, periodic variations in arterial blood pressure are transmitted along the vasculature, resulting in localized deformations of the arterial wall and its surrounding tissue. Quantification of such motions may help understand various cerebrovascular conditions, yet it has proven technically challengin...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2020.3012932

    authors: Abderezaei J,Martinez J,Terem I,Fabris G,Pionteck A,Yang Y,Holdsworth SJ,Nael K,Kurt M

    更新日期:2020-12-01 00:00:00

  • Globally convergent image reconstruction for emission tomography using relaxed ordered subsets algorithms.

    abstract::We present two types of globally convergent relaxed ordered subsets (OS) algorithms for penalized-likelihood image reconstruction in emission tomography: modified block sequential regularized expectation-maximization (BSREM) and relaxed OS separable paraboloidal surrogates (OS-SPS). The global convergence proof of the...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2003.812251

    authors: Ahn S,Fessler JA

    更新日期:2003-05-01 00:00:00

  • Spiral-CT-based assessment of tracheal stenoses using 3-D-skeletonization.

    abstract:PURPOSE:Demonstration of a technique for three-dimensional (3-D) assessment of tracheal-stenoses, regarding site, length and degree, based on spiral computed tomography (S-CT). PATIENTS AND METHODS:S-CT scanning and automated segmentation of the laryngo-tracheal tract (LTT) was followed by the extraction of the LTT me...

    journal_title:IEEE transactions on medical imaging

    pub_type: 临床试验,杂志文章

    doi:10.1109/42.996344

    authors: Sorantin E,Halmai C,Erdöhelyi B,Palágyi K,Nyúl LG,Ollé K,Geiger B,Lindbichler F,Friedrich G,Kiesler K

    更新日期:2002-03-01 00:00:00

  • Robust Empirical Bayesian Reconstruction of Distributed Sources for Electromagnetic Brain Imaging.

    abstract::Electromagnetic brain imaging is the reconstruction of brain activity from non-invasive recordings of the magnetic fields and electric potentials. An enduring challenge in this imaging modality is estimating the number, location, and time course of sources, especially for the reconstruction of distributed brain source...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2019.2932290

    authors: Cai C,Diwakar M,Chen D,Sekihara K,Nagarajan SS

    更新日期:2020-03-01 00:00:00

  • Noise characterization of block-iterative reconstruction algorithms: II. Monte Carlo simulations.

    abstract::In Soares et al. (2000), the ensemble statistical properties of the rescaled block-iterative expectation-maximization (RBI-EM) reconstruction algorithm and rescaled block-iterative simultaneous multiplicative algebraic reconstruction technique (RBI-SMART) were derived. Included in this analysis were the special cases ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/tmi.2004.836876

    authors: Soares EJ,Glick SJ,Hoppin JW

    更新日期:2005-01-01 00:00:00

  • Frequency-domain optical tomographic imaging of arthritic finger joints.

    abstract::We are presenting data from the largest clinical trial on optical tomographic imaging of finger joints to date. Overall we evaluated 99 fingers of patients affected by rheumatoid arthritis (RA) and 120 fingers from healthy volunteers. Using frequency-domain imaging techniques we show that sensitivities and specificiti...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2011.2135374

    authors: Hielscher AH,Kim HK,Montejo LD,Blaschke S,Netz UJ,Zwaka PA,Illing G,Muller GA,Beuthan J

    更新日期:2011-10-01 00:00:00

  • Splat feature classification with application to retinal hemorrhage detection in fundus images.

    abstract::A novel splat feature classification method is presented with application to retinal hemorrhage detection in fundus images. Reliable detection of retinal hemorrhages is important in the development of automated screening systems which can be translated into practice. Under our supervised approach, retinal color images...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2012.2227119

    authors: Tang L,Niemeijer M,Reinhardt JM,Garvin MK,Abràmoff MD

    更新日期:2013-02-01 00:00:00

  • Including anatomical and functional information in MC simulation of PET and SPECT brain studies. Brain-VISET: a voxel-based iterative method.

    abstract::Monte Carlo (MC) simulation provides a flexible and robust framework to efficiently evaluate and optimize image processing methods in emission tomography. In this work we present Brain-VISET (Voxel-based Iterative Simulation for Emission Tomography), a method that aims to simulate realistic [ (99m) Tc]-SPECT and [ (18...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2014.2326041

    authors: Marti-Fuster B,Esteban O,Thielemans K,Setoain X,Santos A,Ros D,Pavia J

    更新日期:2014-10-01 00:00:00

  • Accuracy of the morphology enabled dipole inversion (MEDI) algorithm for quantitative susceptibility mapping in MRI.

    abstract::Determining the susceptibility distribution from the magnetic field measured in a magnetic resonance (MR) scanner is an ill-posed inverse problem, because of the presence of zeroes in the convolution kernel in the forward problem. An algorithm called morphology enabled dipole inversion (MEDI), which incorporates spati...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2011.2182523

    authors: Liu T,Xu W,Spincemaille P,Avestimehr AS,Wang Y

    更新日期:2012-03-01 00:00:00

  • An image-guided planning system for endosseous oral implants.

    abstract::A preoperative planning system for oral implant surgery was developed which takes as input computed tomographies (CT's) of the jaws. Two-dimensional (2-D) reslices of these axial CT slices orthogonal to a curve following the jaw arch are computed and shown together with three-dimensional (3-D) surface rendered models ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.736056

    authors: Verstreken K,Van Cleynenbreugel J,Martens K,Marchal G,van Steenberghe D,Suetens P

    更新日期:1998-10-01 00:00:00

  • Objective Detection of Eloquent Axonal Pathways to Minimize Postoperative Deficits in Pediatric Epilepsy Surgery using Diffusion Tractography and Convolutional Neural Networks.

    abstract::Convolutional neural networks (CNNs) have recently been used in biomedical imaging applications with great success. In this paper, we investigated the classi?cation performance of CNN models on diffusion weighted imaging (DWI) streamlines de?ned by functional MRI (fMRI) and electrical stimulation mapping (ESM). To lea...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2019.2902073

    authors: Xu H,Dong M,Lee MH,OrHara N,Asano E,Jeong JW

    更新日期:2019-02-27 00:00:00

  • Lumen segmentation and motion estimation in B-mode and contrast-enhanced ultrasound images of the carotid artery in patients with atherosclerotic plaque.

    abstract::In standard B-mode ultrasound (BMUS), segmentation of the lumen of atherosclerotic carotid arteries and studying the lumen geometry over time are difficult owing to irregular lumen shapes, noise, artifacts, and echolucent plaques. Contrast enhanced ultrasound (CEUS) improves lumen visualization, but lumen segmentation...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2014.2372784

    authors: Carvalho DD,Akkus Z,van den Oord SC,Schinkel AF,van der Steen AF,Niessen WJ,Bosch JG,Klein S

    更新日期:2015-04-01 00:00:00

  • Magnetic Particle Imaging: A Resovist Based Marking Technology for Guide Wires and Catheters for Vascular Interventions.

    abstract::Magnetic particle imaging (MPI) is able to provide high temporal and good spatial resolution, high signal to noise ratio and sensitivity. Furthermore, it is a truly quantitative method as its signal strength is proportional to the concentration of its tracer, superparamagnetic iron oxide nanoparticles (SPIOs), over a ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2016.2559538

    authors: Haegele J,Panagiotopoulos N,Cremers S,Rahmer J,Franke J,Duschka RL,Vaalma S,Heidenreich M,Borgert J,Borm P,Barkhausen J,Vogt FM

    更新日期:2016-10-01 00:00:00

  • A filtered backprojection algorithm for triple-source helical cone-beam CT.

    abstract::Multisource cone-beam computed tomography (CT) is an attractive approach of choice for superior temporal resolution, which is critically important for cardiac imaging and contrast enhanced studies. In this paper, we present a filtered-backprojection (FBP) algorithm for triple-source helical cone-beam CT. The algorithm...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2008.2004817

    authors: Zhao J,Jin Y,Lu Y,Wang G

    更新日期:2009-03-01 00:00:00

  • A Predictive Model of Vertebral Trabecular Anisotropy From Ex Vivo Micro-CT.

    abstract::Spine-related disorders are amongst the most frequently encountered problems in clinical medicine. For several applications such as 1) to improve the assessment of the strength of the spine, as well as 2) to optimize the personalization of spinal interventions, image-based biomechanical modeling of the vertebrae is ex...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2014.2387114

    authors: Lekadir K,Hoogendoorn C,Hazrati-Marangalou J,Taylor Z,Noble C,van Rietbergen B,Frangi AF

    更新日期:2015-08-01 00:00:00

  • A spatiotemporal model of cyclic kinematics and its application to analyzing nonrigid motion with MR velocity images.

    abstract::We present a method (DMESH) for nonrigid cyclic motion analysis using a series of velocity images covering the cycle acquired, for example, from phase-contrast magnetic resonance imaging. The method is based on fitting a dynamic finite-element mesh model to velocity samples of an extended region, at all time frames. T...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.790456

    authors: Zhu Y,Pelc NJ

    更新日期:1999-07-01 00:00:00