Abstract:
:Visual estimation of coronary obstruction severity from angiograms suffers from poor inter- and intraobserver reproducibility and is often inaccurate. In spite of the widely recognized limitations of visual analysis, automated methods have not found widespread clinical use, in part because they too frequently fail to accurately identify vessel borders. The authors have developed a robust method for simultaneous detection of left and right coronary borders that is suitable for analysis of complex images with poor contrast, nearby or overlapping structures, or branching vessels. The reliability of the simultaneous border detection method and that of the authors' previously reported conventional border detection method were tested in 130 complex images, selected because conventional automated border detection might be expected to fail. Conventional analysis failed to yield acceptable borders in 65/130 or 50% of images. Simultaneous border detection was much more robust (p<.001) and failed in only 15/130 or 12% of complex images. Simultaneous border detection identified stenosis diameters that correlated significantly better with observer-derived stenosis diameters than did diameters obtained with conventional border detection (p<0.001), Simultaneous detection of left and right coronary borders is highly robust and has substantial promise for enhancing the utility of quantitative coronary angiography in the clinical setting.
journal_name
IEEE Trans Med Imagingjournal_title
IEEE transactions on medical imagingauthors
Sonka M,Winniford MD,Collins SMdoi
10.1109/42.370412subject
Has Abstractpub_date
1995-01-01 00:00:00pages
151-61issue
1eissn
0278-0062issn
1558-254Xjournal_volume
14pub_type
杂志文章abstract::In open image-guided liver surgery (IGLS), a sparse representation of the intraoperative organ surface can be acquired to drive image-to-physical registration. We hypothesize that uncharacterized error induced by variation in the collection patterns of organ surface data limits the accuracy and robustness of an IGLS r...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2017.2668842
更新日期:2017-07-01 00:00:00
abstract::Fluorescence molecular tomography (FMT), which can visualize the distribution of fluorescence biomarkers, has become a novel three-dimensional noninvasive imaging technique for in vivo studies such as tumor detection and lymph node location. However, it remains a challenging problem to achieve satisfactory reconstruct...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2020.2964853
更新日期:2020-06-01 00:00:00
abstract::We propose a method for restoring the underlying true signal in noisy functional images. The Nadaraya-Watson (NW) estimator described in, e.g., [1] is a classical nonparametric estimator for this problem. Since the true scene in many applications contains abrupt changes between pixels of different types, a modificatio...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.906423
更新日期:2001-01-01 00:00:00
abstract::Biomedical applications such as cell tracking and angiography require the detection of low concentrations of superparamagnetic iron oxide nanoparticles (SPIOs) for imaging purposes. Magnetic particle imaging (MPI) is a new technology which enables the quantitative and time-resolved localization of SPIO distributions. ...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2015.2501462
更新日期:2016-03-01 00:00:00
abstract::Spatially variant longitudinal aliasing plagues most volumes reconstructed from single-slice helical computed tomography data, and its presence can degrade resolution and distort image structures. We have recently developed a Fourier-based approach to longitudinal interpolation in helical computed tomography that can,...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2002.803104
更新日期:2002-08-01 00:00:00
abstract::We propose a new spatio-temporal elastic registration algorithm for motion reconstruction from a series of images. The specific application is to estimate displacement fields from two-dimensional ultrasound sequences of the heart. The basic idea is to find a spatio-temporal deformation field that effectively compensat...
journal_title:IEEE transactions on medical imaging
pub_type: 临床试验,杂志文章
doi:10.1109/TMI.2005.852050
更新日期:2005-09-01 00:00:00
abstract::A new, sample independent optimization criterion for minimizing the effect of the imaging gradients, including the directional awareness they create, is defined for diffusion tensor imaging (DTI) experiments. The DTI linear algebraic framework is expanded to a normed space to design optimal diffusion gradient schemes ...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2010.2090539
更新日期:2011-03-01 00:00:00
abstract::Respiratory motion remains a significant source of errors in treatment planning for the thorax and upper abdomen. Recently, we proposed a method to estimate two-dimensional (2-D) object motion from a sequence of slowly rotating X-ray projection views, which we called deformation from orbiting views (DOVs). In this met...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2006.889719
更新日期:2007-02-01 00:00:00
abstract::Cone beam X-ray luminescence computed tomography (CB-XLCT) is a promising imaging technique in studying the physiological and pathological processes in small animals. However, the dynamic bio-distributions of probes in small animal, especially in adjacent targets are still hard to be captured directly from dynamic CB-...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2019.2917026
更新日期:2019-12-01 00:00:00
abstract::An algorithm is presented for the analysis and quantification of the vascular structures of the human retina. Information about retinal blood vessel morphology is used in grading the severity and progression of a number of diseases. These disease processes are typically followed over relatively long time courses, and ...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.363106
更新日期:1994-01-01 00:00:00
abstract::Ultrasonic imaging is the noninvasive clinical imaging modality of choice for diagnosing heart disease. At present, two-dimensional ultrasonic grayscale images provide a relatively cheap, fast, bedside method to study the morphology of the heart. Several methods have been proposed to assess myocardial function. These ...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2002.804440
更新日期:2002-09-01 00:00:00
abstract::Compression elastography allows the precise measurement of large deformations of soft tissue in vivo. From an image sequence showing tissue undergoing large deformation, an inverse problem for both the linear and nonlinear elastic moduli distributions can be solved. As part of a larger clinical study to evaluate nonli...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2020.3036032
更新日期:2020-11-05 00:00:00
abstract::It is well known that the inverse radon transform exists in two forms for odd and even dimension functions, respectively. This note shows that these formulas become zero when the dimension requirement is violated, which results in a simple unified formula for the inverse radon transform of arbitrary dimensions. ...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.476117
更新日期:1995-01-01 00:00:00
abstract::We designed a dedicated multi-detector multi-pinhole brain SPECT scanner to generate images of higher quality compared to general-purpose systems. The system, AdaptiSPECT-C, is intended to adapt its sensitivity-resolution trade-off by varying its aperture configurations allowing both high-sensitivity dynamic and high-...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2020.3015079
更新日期:2020-12-01 00:00:00
abstract::In the PET system a block detector, which is a position-sensitive photomultiplier (PMT) tube coupled to four arrays of 1.7-mm-wide BGO crystals, is utilized. Fifteen block detectors are positioned to form a 35-cm-diameter ring, with four BGO arrays coupled to each PMT. This provides four detector rings, giving the sys...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.192694
更新日期:1992-01-01 00:00:00
abstract::Dynamic systems have proven to be well suited to describe a broad spectrum of human coordination behavior such synchronization with auditory stimuli. Simultaneous measurements of the spatiotemporal dynamics of electroencephalographic (EEG) and magnetoencephalographic (MEG) data reveals that the dynamics of the brain s...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2002.1009385
更新日期:2002-05-01 00:00:00
abstract::Several techniques based on the three-dimensional (3-D) discrete cosine transform (DCT) have been proposed for volumetric data coding. These techniques fail to provide lossless coding coupled with quality and resolution scalability, which is a significant drawback for medical applications. This paper gives an overview...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/tmi.2003.809582
更新日期:2003-03-01 00:00:00
abstract::We consider 3-D brain structures as continuous parameterized surfaces and present a metric for their comparisons that is invariant to the way they are parameterized. Past comparisons of such surfaces involve either volume deformations or nonrigid matching under fixed parameterizations of surfaces. We propose a new mat...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2010.2099130
更新日期:2011-03-01 00:00:00
abstract::Passive monitoring of the thermal noise variances of the channels of a receive array was shown to reveal respiratory motion of the underlying anatomy, a so called "noise navigator". There is, however, an inevitable trade off between the accuracy and temporal resolution of the noise navigator due to its passive nature....
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2018.2808699
更新日期:2018-08-01 00:00:00
abstract::In this paper, we propose a new prostate computed tomography (CT) segmentation method for image guided radiation therapy. The main contributions of our method lie in the following aspects. 1) Instead of using voxel intensity information alone, patch-based representation in the discriminative feature space with logisti...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2012.2230018
更新日期:2013-02-01 00:00:00
abstract::Look-up tables (LUTs) are a common method for increasing the speed of many algorithms. Their use can be extended to the reconstruction of nonuniformly sampled k-space data using either a discrete Fourier transform (DFT) algorithm or a convolution-based gridding algorithm. A table for the DFT would be precalculated arr...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.918471
更新日期:2001-03-01 00:00:00
abstract::The quality and quantitative accuracy of iteratively reconstructed SPECT images improves when better point spread function (PSF) models of the gamma camera are used during reconstruction. Here, inclusion in the PSF model of photon crosstalk between different slices caused by limited gamma camera resolution and scatter...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.511752
更新日期:1996-01-01 00:00:00
abstract::We propose an optimization algorithm to solve the brachytherapy seed localization problem in prostate brachytherapy. Our algorithm is based on novel geometric approaches to exploit the special structure of the problem and relies on a number of key observations which help us formulate the optimization problem as a mini...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2007.900740
更新日期:2007-09-01 00:00:00
abstract::We present a new method to automatically compute, reorient, and recenter the mid-sagittal plane in anatomical and functional three-dimensional (3-D) brain images. This iterative approach is composed of two steps. At first, given an initial guess of the mid-sagittal plane (generally, the central plane of the image grid...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.993131
更新日期:2002-02-01 00:00:00
abstract::Image reconstruction in low-count PET is particularly challenging because gammas from natural radioactivity in Lu-based crystals cause high random fractions that lower the measurement signal-to-noise-ratio (SNR). In model-based image reconstruction (MBIR), using more iterations of an unregularized method may increase ...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2020.2998480
更新日期:2020-11-01 00:00:00
abstract::Cardiac resynchronization therapy (CRT) has been shown to improve cardiovascular function in specific patients suffering from heart failure. This procedure still needs to be optimized to overcome the high rate of implanted patients that do not respond to this therapy. We propose in this work a better characterization ...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2014.2311694
更新日期:2014-06-01 00:00:00
abstract::Ultrafast ultrasound imaging using plane or diverging waves, instead of focused beams, has advanced greatly the development of novel ultrasound imaging methods for evaluating tissue functions beyond anatomical information. However, the sonographic signal-to-noise ratio (SNR) of ultrafast imaging remains limited due to...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2017.2781261
更新日期:2018-04-01 00:00:00
abstract::A new graph-based approach for segmentation of luminal and external elastic lamina (EEL) surface of coronary vessels in gated 20 MHz intravascular ultrasound (IVUS) image sequences (volumes) is presented. The approach consists of a fully automated segmentation stage ("new automated" or NA) and a user-guided computer-a...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2013.2260763
更新日期:2013-08-01 00:00:00
abstract::Almost all magnetic resonance electrical impedance tomography (MREIT) reconstruction algorithms proposed to date assume isotropic conductivity in order to simplify the image reconstruction. However, it is well known that most of biological tissues have anisotropic conductivity values. In this study, four novel anisotr...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2011.2171192
更新日期:2012-03-01 00:00:00
abstract::A common challenge when performing surface-based registration of images is ensuring that the surfaces accurately represent consistent anatomical boundaries. Image segmentation may be difficult in some regions due to either poor contrast, low slice resolution, or tissue ambiguities. To address this, we present a novel ...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2015.2443978
更新日期:2015-12-01 00:00:00