Abstract:
:High peak RF amplitude and excessive specific absorption rate (SAR) are two critical concerns for hardware implementation and patient safety in scientific and clinical research for high field MRI using parallel transmissions (pTX). In this paper, we introduce a squeezing strategy to reduce peak RF amplitude and integrated RF power via direct reshaping of the k-space trajectory. In the existing peak RF / integrated RF power optimization methods gradient amplitude or slew rate is reduced, but the k-space trajectory remains unchanged. Unlike these traditional methods, we worked directly in the excitation k-space to reshape k-space traversal by a squeezing vector in order to achieve peak RF and total RF power optimization, using a particle swarm optimization algorithm. The squeezing strategy was applied to the conventional variable density spiral (CVDS) and the variable rate selective excitation (VERSE) trajectories, dubbed SVDS (squeezed variable density spiral) and SVERSE (squeezing trajectory with VERSE), respectively, for different excitation profiles of small or large tip angles. Pulse acceleration and off-resonance effects were evaluated for an 8-ch pTX via Bloch simulation. CVDS, VERSE, SVDS, and SVERSE pulses were implemented on a 3T scanner with a 2-ch pTX. Phantom and in vivo experiments were performed for reduced FOV (rFOV) imaging. The results show that SVDS pulses simultaneously reduce integrated RF power and peak RF by about 30% on average compared to CVDS pulses for a square pattern ( $80\times80$ mm2) with flip angles of 30°, 90°, and 180°. Compared with the VERSE method under the same peak RF constraints, the SVDS method reduces integrated RF power by an average of 20% for small tip excitations for profiles of slice, rectangular, square, and circle, and has slightly reduced excitation accuracy slightly (about 0.6%, from 6.8% to 7.4%). The SVERSE method shortens the duration of the VERSE pulse by 12.8% at large ti p angle (180°). Feasibility for rFOV imaging was demonstrated with phantom and in vivo experiments with squeezed pulses.
journal_name
IEEE Trans Med Imagingjournal_title
IEEE transactions on medical imagingauthors
Li Q,Liao C,Ye H,Chen Y,Cao X,Yuan L,He H,Zhong Jdoi
10.1109/TMI.2018.2828112subject
Has Abstractpub_date
2018-08-01 00:00:00pages
1809-1821issue
8eissn
0278-0062issn
1558-254Xjournal_volume
37pub_type
杂志文章abstract::Most X-ray fluoroscopy systems are stationary and impose restrictions on the measurement of dynamic joint motion; for example, knee-joint kinematics during gait is usually measured with the subject ambulating on a treadmill. We developed a computer-controlled, mobile, biplane, X-ray fluoroscopy system to track human b...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2015.2473168
更新日期:2016-01-01 00:00:00
abstract::Micro-computed tomography (micro-CT) has been widely used to generate high-resolution 3-D tissue images from small animals nondestructively, especially for mineralized skeletal tissues. However, its application to the analysis of soft cardiovascular tissues has been limited by poor inter-tissue contrast. Recent ex viv...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2012.2209183
更新日期:2013-01-01 00:00:00
abstract::We propose a method that incorporates the time-frequency characteristics of neural sources into magnetoencephalographic (MEG) source estimation. The method is based on the multiple-signal-classification (MUSIC) algorithm and it calculates a time--frequency matrix in which diagonal and off-diagonal terms are the auto a...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.750262
更新日期:1999-01-01 00:00:00
abstract::This paper addresses the long object problem in helical cone-beam computed tomography. We present the PHI-method, a new algorithm for the exact reconstruction of a region-of-interest (ROI) of a long object from axially truncated data extending only slightly beyond the ROI. The PHI-method is an extension of the Radon-m...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.870247
更新日期:2000-05-01 00:00:00
abstract::Recently, deep neural networks have been widely and successfully applied in computer vision tasks and have attracted growing interest in medical imaging. One barrier for the application of deep neural networks to medical imaging is the need for large amounts of prior training pairs, which is not always feasible in cli...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2018.2888491
更新日期:2019-07-01 00:00:00
abstract::With each heartbeat, periodic variations in arterial blood pressure are transmitted along the vasculature, resulting in localized deformations of the arterial wall and its surrounding tissue. Quantification of such motions may help understand various cerebrovascular conditions, yet it has proven technically challengin...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2020.3012932
更新日期:2020-12-01 00:00:00
abstract::We describe a fast forward and back projector pair based on inverse Fourier rebinning for use in iterative image reconstruction for fully three-dimensional (3-D) positron emission tomography (PET). The projector pair is used as part of a factored system matrix that takes into account detector-pair response by using sh...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:
更新日期:2007-03-01 00:00:00
abstract::Fan-beam collimators are used in single photon emission computed tomography to improve the sensitivity for imaging of small organs. The disadvantage of fan-beam collimation is the truncation of projection data surrounding the organ of interest or, in those cases of imaging large patients, of the organ itself producing...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.310886
更新日期:1994-01-01 00:00:00
abstract::It is well understood that binary classifiers have two implicit objective functions (sensitivity and specificity) describing their performance. Traditional methods of classifier training attempt to combine these two objective functions (or two analogous class performance measures) into one so that conventional scalar ...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.796281
更新日期:1999-08-01 00:00:00
abstract::Displacement estimated interframe (DEI) coding, a coding scheme for 3-D medical image data sets such as X-ray computed tomography (CT) or magnetic resonance (MR) images, is presented. To take advantage of the correlation between contiguous slices, a displacement-compensated difference image based on the previous image...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.241875
更新日期:1993-01-01 00:00:00
abstract::Several different reconstruction algorithms have been proposed for photoacoustic tomography, most of which presuppose that the acoustic properties of the medium are constant and homogeneous. In practice, there are often unknown spatial variations in the acoustic properties, and these algorithms give, at best, only app...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2009.2032358
更新日期:2010-02-01 00:00:00
abstract::Over the years, medical image tracking has gained considerable attention from both medical and research communities due to its widespread utility in a multitude of clinical applications, from functional assessment during diagnosis and therapy planning to structure tracking or image fusion during image-guided intervent...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2018.2840820
更新日期:2018-11-01 00:00:00
abstract::The effects of Squashing, an algorithm introduced by J.A. Reeds and L.A. Shepp (see ibid., vol.MI-6, no.2, p.89-97, June 1987), are described. It is proven that Squashing induces a weight function upon the projections. Intuitive and numerical evidence is presented showing that this weight function is not desirable at ...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.57761
更新日期:1990-01-01 00:00:00
abstract::We propose a new method for deformable registration of pre-operative and post-recurrence brain MR scans of glioma patients. Performing this type of intra-subject registration is challenging as tumor, resection, recurrence, and edema cause large deformations, missing correspondences, and inconsistent intensity profiles...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2013.2293478
更新日期:2014-03-01 00:00:00
abstract::Microwave radar imaging is promising as a complementary medical imaging modality. However, the unique nature of the images means interpretation can be difficult. As a result, it is important to understand the sources of image differences, and how much variability is inherent in the imaging system itself. To address th...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2018.2806878
更新日期:2018-08-01 00:00:00
abstract::Magnetic resonance fingerprinting (MRF) is a quantitative imaging technique that can simultaneously measure multiple important tissue properties of human body. Although MRF has demonstrated improved scan efficiency as compared to conventional techniques, further acceleration is still desired for translation into routi...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2019.2899328
更新日期:2019-10-01 00:00:00
abstract::It is well known that the energy dependence of X-ray attenuation can be used to characterize materials. Yet, even with energy discriminating photon counting X-ray detectors, it is still unclear how to best form energy dependent measurements for spectral imaging. Common ideas include binning photon counts based on thei...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2010.2061862
更新日期:2011-01-01 00:00:00
abstract::Regularization is desirable for image reconstruction in emission tomography. A powerful regularization method is the penalized-likelihood (PL) reconstruction algorithm (or equivalently, maximum a posteriori reconstruction), where the sum of the likelihood and a noise suppressing penalty term (or Bayesian prior) is opt...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2003.816960
更新日期:2003-09-01 00:00:00
abstract::We show that electrical impedance tomography (EIT) image reconstruction algorithms with regularization based on the total variation (TV) functional are suitable for in vivo imaging of physiological data. This reconstruction approach helps to preserve discontinuities in reconstructed profiles, such as step changes in e...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2009.2022540
更新日期:2010-01-01 00:00:00
abstract::Photon counting computed tomography (PCCT) has the ability to identify individual photons, resulting in quantitative material identification. Meanwhile, several technical challenges still exist in current PCCT imaging systems, including increased noise and suboptimal bin selection. These nonideal effects can substanti...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2020.3001616
更新日期:2020-11-01 00:00:00
abstract::Video capsule endoscopy (VCE) is a noninvasive method for examining the gastrointestinal tract which has been successful in small intestine studies. Recently, VCE has been attempted in the colon. However, the capsule often tumbles in the wider colonic lumen, resulting in missed regions. Self-stabilizing VCE is a novel...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2011.2163165
更新日期:2011-12-01 00:00:00
abstract::In the technique known as gridding, the data samples are weighted for sampling density and convolved with a finite kernel, then resampled on a grid preparatory to a fast Fourier transform. The authors compare the artifact introduced into the image for various convolving functions of different sizes, including the Kais...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.97598
更新日期:1991-01-01 00:00:00
abstract::Automated whole breast ultrasound (ABUS) is becoming a popular screening modality for whole breast examination. Compared to conventional handheld ultrasound, ABUS achieves operator-independent and is feasible for mass screening. However, reviewing hundreds of slices in an ABUS image volume is time-consuming. A compute...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2014.2315206
更新日期:2014-07-01 00:00:00
abstract::We suggest a polynomial program for the calculation of optimized gradient waveforms for magnetic resonance tomography pulse sequences. Such non-linear mathematical programs can describe gradient system capabilities, meet k-space trajectory specifications, and capture sequence timing conditions. Moreover they allow the...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2010.2042723
更新日期:2010-06-01 00:00:00
abstract::The aim of this work is the evaluation of the design for a nonconventional PET scanner, the voxel imaging PET (VIP), based on pixelated room-temperature CdTe detectors yielding a true 3-D impact point with a density of 450 channels/cm(3), for a total 6 336 000 channels in a seamless ring shaped volume. The system is s...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2013.2284657
更新日期:2014-02-01 00:00:00
abstract::We propose a method for restoring the underlying true signal in noisy functional images. The Nadaraya-Watson (NW) estimator described in, e.g., [1] is a classical nonparametric estimator for this problem. Since the true scene in many applications contains abrupt changes between pixels of different types, a modificatio...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.906423
更新日期:2001-01-01 00:00:00
abstract::This paper describes the implementation of a novel and robust threshold energy calibration method for photon counting detectors using polychromatic X-ray tubes. Methods often used for such energy calibration may require re-orientation of the detector or introduce calibration errors that are flux and acquisition time-d...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2018.2875932
更新日期:2019-04-01 00:00:00
abstract::The automatic diagnosis of various retinal diseases from fundus images is important to support clinical decision-making. However, developing such automatic solutions is challenging due to the requirement of a large amount of human-annotated data. Recently, unsupervised/self-supervised feature learning techniques recei...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2020.3008871
更新日期:2020-12-01 00:00:00
abstract::Colorectal cancer can easily be prevented provided that the precursors to tumors, small colonic polyps, are detected and removed. Currently, the only definitive examination of the colon is fiber-optic colonoscopy, which is invasive and expensive. Computed tomographic colonography (CTC) is potentially a less costly and...
journal_title:IEEE transactions on medical imaging
pub_type: 临床试验,杂志文章
doi:10.1109/TMI.2002.806405
更新日期:2002-12-01 00:00:00
abstract::The quality of magnetic resonance imaging systems has improved to the point that motion is a major limitation in many examinations. Translational motion in the imaging plane causes the phase of the data to be corrupted. An algorithm using computer post-processing is proposed to correct the phase of the data, and hence...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.108589