Abstract:
:The aim of this work is the evaluation of the design for a nonconventional PET scanner, the voxel imaging PET (VIP), based on pixelated room-temperature CdTe detectors yielding a true 3-D impact point with a density of 450 channels/cm(3), for a total 6 336 000 channels in a seamless ring shaped volume. The system is simulated and evaluated following the prescriptions of the NEMA NU 2-2001 and the NEMA NU 4-2008 standards. Results show that the excellent energy resolution of the CdTe detectors (1.6% for 511 keV photons), together with the small voxel pitch (1 × 1 × 2 mm(3)), and the crack-free ring geometry, give the design the potential to overcome the current limitations of PET scanners and to approach the intrinsic image resolution limits set by physics. The VIP is expected to reach a competitive sensitivity and a superior signal purity with respect to values commonly quoted for state-of-the-art scintillating crystal PETs. The system can provide 14 cps/kBq with a scatter fraction of 3.95% and 21 cps/kBq with a scatter fraction of 0.73% according to NEMA NU 2-2001 and NEMA NU 4-2008, respectively. The calculated NEC curve has a peak value of 122 kcps at 5.3 kBq/mL for NEMA NU 2-2001 and 908 kcps at 1.6 MBq/mL for NEMA NU 4-2008. The proposed scanner can achieve an image resolution of ~ 1 mm full-width at half-maximum in all directions. The virtually noise-free data sample leads to direct positive impact on the quality of the reconstructed images. As a consequence, high-quality high-resolution images can be obtained with significantly lower number of events compared to conventional scanners. Overall, simulation results suggest the VIP scanner can be operated either at normal dose for fast scanning and high patient throughput, or at low dose to decrease the patient radioactivity exposure. The design evaluation presented in this work is driving the development and the optimization of a fully operative prototype to prove the feasibility of the VIP concept.
journal_name
IEEE Trans Med Imagingjournal_title
IEEE transactions on medical imagingauthors
Mikhaylova E,De Lorenzo G,Chmeissani M,Kolstein M,Cañadas M,Arce P,Calderón Y,Uzun D,Ariño G,Macias-Montero JG,Martinez R,Puigdengoles C,Cabruja Edoi
10.1109/TMI.2013.2284657subject
Has Abstractpub_date
2014-02-01 00:00:00pages
332-9issue
2eissn
0278-0062issn
1558-254Xjournal_volume
33pub_type
杂志文章abstract::Generalized matrix inverses are used to estimate source activity distributions from single photon emission computed tomography (SPECT) projection measurements. Image reconstructions for a numerical simulation and a clinical brain study are examined. The photon flux from the source region and photon detection by the ga...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.141640
更新日期:1992-01-01 00:00:00
abstract::In this paper, we propose a novel deep learning framework for anatomy segmentation and automatic landmarking. Specifically, we focus on the challenging problem of mandible segmentation from cone-beam computed tomography (CBCT) scans and identification of 9 anatomical landmarks of the mandible on the geodesic space. Th...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2018.2875814
更新日期:2019-04-01 00:00:00
abstract::We describe a matched subspace detection algorithm to assist in the detection of small tumors in dynamic positron emission tomography (PET) images. The algorithm is designed to differentiate tumors from background using the time activity curves (TACs) that characterize the uptake of PET tracers. TACs are modeled using...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2008.929105
更新日期:2009-02-01 00:00:00
abstract::Photon counting computed tomography (PCCT) has the ability to identify individual photons, resulting in quantitative material identification. Meanwhile, several technical challenges still exist in current PCCT imaging systems, including increased noise and suboptimal bin selection. These nonideal effects can substanti...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2020.3001616
更新日期:2020-11-01 00:00:00
abstract::This paper presents a novel image-guided robot-based system to assist orthopedic surgeons in performing distal locking of long bone intramedullary nails. The system consists of a bone-mounted miniature robot fitted with a drill guide that provides rigid mechanical guidance for hand-held drilling of the distal screws' ...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2005.844922
更新日期:2005-05-01 00:00:00
abstract::Echo-planar imaging (EPI) is a fast nuclear magnetic resonance imaging (MRI) method. Unfortunately, local magnetic field inhomogeneities induced mainly by the subject's presence cause significant geometrical distortion, predominantly along the phase-encoding direction, which must be undone to allow for meaningful furt...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.836368
更新日期:2000-02-01 00:00:00
abstract::A special-purpose hardware architecture is proposed to implement the expectation-maximization algorithm to compute, in clinically useful times, the maximum-likelihood estimate of a radionuclide distribution for a positron-emission tomogram from time-of-flight measurements. Two-dimensional convolutions required for for...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.14510
更新日期:1988-01-01 00:00:00
abstract::We aim to compute the movement of permanent stranded implant brachytherapy radioactive sources (seeds) in the prostate from the planned seed distribution to the intraoperative fluoroscopic distribution, and then to the postimplant computed tomography (CT) distribution. We present a novel approach to matching the seeds...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2011.2178254
更新日期:2012-03-01 00:00:00
abstract::Spectral computed tomography (CT) is a promising technique with the potential for improving lesion detection, tissue characterization, and material decomposition. In this paper, we are interested in kVp switching-based spectral CT that alternates distinct kVp X-ray transmissions during gantry rotation. This system can...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2014.2380993
更新日期:2015-03-01 00:00:00
abstract::Cell segmentation and tracking in time-lapse fluorescence microscopy images is a task of fundamental importance in many biological studies on cell migration and proliferation. In recent years, level sets have been shown to provide a very appropriate framework for this purpose, as they are well suited to capture topolo...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2009.2038693
更新日期:2010-03-01 00:00:00
abstract::The success of prostate brachytherapy critically depends on delivering adequate dose to the prostate gland. Intraoperative localization of the implanted seeds provides potential for dose evaluation and optimization during therapy. A reduced-dimensionality matching algorithm for prostate brachytherapy seed reconstructi...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2010.2059709
更新日期:2011-01-01 00:00:00
abstract::The interpolation of missing spatial frequencies through the generalized auto-calibrating partially parallel acquisitions (GRAPPA) parallel magnetic resonance imaging (MRI) model implies a correlation is induced between the acquired and reconstructed frequency measurements. As the parallel image reconstruction algorit...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2013.2288521
更新日期:2014-02-01 00:00:00
abstract::Cervical cancer causes the fourth most cancer-related deaths of women worldwide. Early detection of cervical intraepithelial neoplasia (CIN) can significantly increase the survival rate of patients. In this paper, we propose a deep learning framework for the accurate identification of LSIL+ (including CIN and cervical...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2020.2994778
更新日期:2020-11-01 00:00:00
abstract::An overview of the Shinnar-Le Roux (SLR) algorithm is presented. It is shown how the performance of SLR pulses can be very accurately specified analytically. This reveals how to design a pulse that produces a specified slice profile and allows the pulse designer to trade off analytically the parameters describing the ...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.75611
更新日期:1991-01-01 00:00:00
abstract::Determining the susceptibility distribution from the magnetic field measured in a magnetic resonance (MR) scanner is an ill-posed inverse problem, because of the presence of zeroes in the convolution kernel in the forward problem. An algorithm called morphology enabled dipole inversion (MEDI), which incorporates spati...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2011.2182523
更新日期:2012-03-01 00:00:00
abstract::Ultrasound molecular imaging (USMI) is accomplished by detecting microbubble (MB) contrast agents that have bound to specific biomarkers, and can be used for a variety of imaging applications, such as the early detection of cancer. USMI has been widely utilized in preclinical imaging in mice; however, USMI in humans c...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2017.2774814
更新日期:2018-01-01 00:00:00
abstract::Fluorescence loss in photobleaching (FLIP) is a method to study compartment connectivity in living cells. A FLIP sequence is obtained by alternatively bleaching a spot in a cell and acquiring an image of the complete cell. Connectivity is estimated by comparing fluorescence signal attenuation in different cell parts. ...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2011.2171497
更新日期:2012-02-01 00:00:00
abstract::The performance of a classifier is largely dependent on the size and representativeness of data used for its training. In circumstances where accumulation and/or labeling of training samples is difficult or expensive, such as medical applications, data augmentation can potentially be used to alleviate the limitations ...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2016.2640180
更新日期:2017-04-01 00:00:00
abstract::We propose an anatomy-based approach for an efficient construction of a three-dimensional human normal cerebral arterial model from segmented and skeletonized angiographic data. The centerline-based model is used for an accurate angiographic data representation. A vascular tree is represented by tubular segments and b...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/tmi.2005.845041
更新日期:2005-04-01 00:00:00
abstract::The purpose of this work is to study the architecture of the rearfoot using in vivo MR image data. Each data set used in this study is made of sixty sagittal slices of the foot acquired in a 1.5-T commercial GE MR system. We use the live-wire method to delineate boundaries and form the surfaces of the bones. In the fi...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.802753
更新日期:1999-09-01 00:00:00
abstract::With the widespread use of positron emission tomography (PET) crystals with greatly improved energy resolution (e.g., 11.5% with LYSO as compared to 20% with BGO) and of list-mode acquisitions, the use of the energy of individual events in scatter correction schemes becomes feasible. We propose a novel scatter approac...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2010.2095025
更新日期:2011-03-01 00:00:00
abstract::Foreshortening of vessel segments in angiographic (biplane) projection images may cause misinterpretation of the extent and degree of coronary artery disease. The views in which the object of interest are visualized with minimum foreshortening are called optimal views. The authors present a complete approach to obtain...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.276141
更新日期:1994-01-01 00:00:00
abstract::A method for detection and removal of random spike noise in magnetic resonance (MR) raw data (k-space data) is described. This method would reduce or eliminate the corduroy-type and higher than usual level artifacts in MR images resulting from random spike noise in k-space data. The method described involves applying ...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.276151
更新日期:1994-01-01 00:00:00
abstract::In this paper, we are interested in soft tissue differentiation by multiband images obtained from the High-Resolution Ultrasonic Transmission Tomography (HUTT) system using a spectral target detection method based on constrained energy minimization (CEM). We have developed a new tissue differentiation method (called "...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/tmi.2004.843179
更新日期:2005-03-01 00:00:00
abstract::The effects of Squashing, an algorithm introduced by J.A. Reeds and L.A. Shepp (see ibid., vol.MI-6, no.2, p.89-97, June 1987), are described. It is proven that Squashing induces a weight function upon the projections. Intuitive and numerical evidence is presented showing that this weight function is not desirable at ...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.57761
更新日期:1990-01-01 00:00:00
abstract::The most frequent extracranial solid tumors of childhood, named peripheral neuroblastic tumors (pNTs), are very challenging to diagnose due to their diversified categories and varying forms. Auxiliary diagnosis methods of such pediatric malignant cancers are highly needed to provide pathologists assistance and reduce ...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2020.3027547
更新日期:2021-01-01 00:00:00
abstract::It is well known that the inverse radon transform exists in two forms for odd and even dimension functions, respectively. This note shows that these formulas become zero when the dimension requirement is violated, which results in a simple unified formula for the inverse radon transform of arbitrary dimensions. ...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.476117
更新日期:1995-01-01 00:00:00
abstract::Imaging intramyocardial vascular flows in real-time could strongly help to achieve better diagnostic of cardiovascular diseases. To date, no standard imaging modality allows describing accurately myocardial blood flow dynamics with good spatial and temporal resolution. We recently introduced a novel ultrasonic Doppler...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2012.2203316
更新日期:2012-08-01 00:00:00
abstract::In traditional transillumination of the breast (diaphanography), the abundance of diffuse light resulting from the use of extended noncollimated sources reduces the visibility of deep seated lesions. A prototype scanning imaging system has been developed to investigate the effectiveness of thin collimated light beams ...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.251126
更新日期:1993-01-01 00:00:00
abstract::Cataract is the clouding of lens, which affects vision and it is the leading cause of blindness in the world's population. Accurate and convenient cataract detection and cataract severity evaluation will improve the situation. Automatic cataract detection and grading methods are proposed in this paper. With prior know...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2019.2928229
更新日期:2020-02-01 00:00:00