Sparse-view spectral CT reconstruction using spectral patch-based low-rank penalty.

Abstract:

:Spectral computed tomography (CT) is a promising technique with the potential for improving lesion detection, tissue characterization, and material decomposition. In this paper, we are interested in kVp switching-based spectral CT that alternates distinct kVp X-ray transmissions during gantry rotation. This system can acquire multiple X-ray energy transmissions without additional radiation dose. However, only sparse views are generated for each spectral measurement; and the spectra themselves are limited in number. To address these limitations, we propose a penalized maximum likelihood method using spectral patch-based low-rank penalty, which exploits the self-similarity of patches that are collected at the same position in spectral images. The main advantage is that the relatively small number of materials within each patch allows us to employ the low-rank penalty that is less sensitive to intensity changes while preserving edge directions. In our optimization formulation, the cost function consists of the Poisson log-likelihood for X-ray transmission and the nonconvex patch-based low-rank penalty. Since the original cost function is difficult to minimize directly, we propose an optimization method using separable quadratic surrogate and concave convex procedure algorithms for the log-likelihood and penalty terms, which results in an alternating minimization that provides a computational advantage because each subproblem can be solved independently. We performed computer simulations and a real experiment using a kVp switching-based spectral CT with sparse-view measurements, and compared the proposed method with conventional algorithms. We confirmed that the proposed method improves spectral images both qualitatively and quantitatively. Furthermore, our GPU implementation significantly reduces the computational cost.

journal_name

IEEE Trans Med Imaging

authors

Kim K,Ye JC,Worstell W,Ouyang J,Rakvongthai Y,El Fakhri G,Li Q

doi

10.1109/TMI.2014.2380993

subject

Has Abstract

pub_date

2015-03-01 00:00:00

pages

748-60

issue

3

eissn

0278-0062

issn

1558-254X

journal_volume

34

pub_type

杂志文章
  • Improving Registration Robustness for Image-Guided Liver Surgery in a Novel Human-to-Phantom Data Framework.

    abstract::In open image-guided liver surgery (IGLS), a sparse representation of the intraoperative organ surface can be acquired to drive image-to-physical registration. We hypothesize that uncharacterized error induced by variation in the collection patterns of organ surface data limits the accuracy and robustness of an IGLS r...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2017.2668842

    authors: Collins JA,Weis JA,Heiselman JS,Clements LW,Simpson AL,Jarnagin WR,Miga MI

    更新日期:2017-07-01 00:00:00

  • Fractal feature analysis and classification in medical imaging.

    abstract::Following B.B. Mandelbrot's fractal theory (1982), it was found that the fractal dimension could be obtained in medical images by the concept of fractional Brownian motion. An estimation concept for determination of the fractal dimension based upon the concept of fractional Brownian motion is discussed. Two applicatio...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.24861

    authors: Chen CC,Daponte JS,Fox MD

    更新日期:1989-01-01 00:00:00

  • Accelerated iterative transmission CT reconstruction using an ordered subsets convex algorithm.

    abstract::Iterative maximum likelihood (ML) transmission computed tomography algorithms have distinct advantages over Fourier-based reconstruction, but unfortunately require increased computation time. The convex algorithm [1] is a relatively fast iterative ML algorithm but it is nevertheless too slow for many applications. The...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.746730

    authors: Kamphuis C,Beekman FJ

    更新日期:1998-12-01 00:00:00

  • Motion estimation of skeletonized angiographic images using elastic registration.

    abstract::An approach for estimating the motion of arteries in digital angiographic image sequences is proposed. Binary skeleton images are registered using an elastic registration algorithm in order to estimate the motion of the corresponding arteries. This algorithm operates recursively on the skeleton images by considering a...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.310876

    authors: Tom BS,Efstratiadis SN,Katsaggelos AK

    更新日期:1994-01-01 00:00:00

  • Unsupervised MR-to-CT Synthesis Using Structure-Constrained CycleGAN.

    abstract::Synthesizing a CT image from an available MR image has recently emerged as a key goal in radiotherapy treatment planning for cancer patients. CycleGANs have achieved promising results on unsupervised MR-to-CT image synthesis; however, because they have no direct constraints between input and synthetic images, cycleGAN...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2020.3015379

    authors: Yang H,Sun J,Carass A,Zhao C,Lee J,Prince JL,Xu Z

    更新日期:2020-12-01 00:00:00

  • PORTR: Pre-operative and post-recurrence brain tumor registration.

    abstract::We propose a new method for deformable registration of pre-operative and post-recurrence brain MR scans of glioma patients. Performing this type of intra-subject registration is challenging as tumor, resection, recurrence, and edema cause large deformations, missing correspondences, and inconsistent intensity profiles...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2013.2293478

    authors: Kwon D,Niethammer M,Akbari H,Bilello M,Davatzikos C,Pohl KM

    更新日期:2014-03-01 00:00:00

  • Shielded microstrip array for 7T human MR imaging.

    abstract::The high-frequency transceiver array based on the microstrip transmission line design is a promising technique for ultrahigh field magnetic resonance imaging (MRI) signal excitation and reception. However, with the increase of radio-frequency (RF) channels, the size of the ground plane in each microstrip coil element ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2009.2033597

    authors: Wu B,Wang C,Kelley DA,Xu D,Vigneron DB,Nelson SJ,Zhang X

    更新日期:2010-01-01 00:00:00

  • Comments on "A new algorithm for border description of polarized light surface microscopic images of pigmented skin lesions".

    abstract::In this paper, discrepancies and reference inaccuracies in the paper (Grana et al., 2003) are pointed out. Specifically, it is demonstrated that the definitions of "lesion gradient" and "skin lesion gradient," widely used in a number of medical papers on computer analysis of pigmented skin lesions, are unambiguous, an...

    journal_title:IEEE transactions on medical imaging

    pub_type: 评论,信件

    doi:10.1109/tmi.2006.884205

    authors: Burroni M,Alparone L,Argenti F

    更新日期:2006-12-01 00:00:00

  • A new algorithm for border description of polarized light surface microscopic images of pigmented skin lesions.

    abstract::The aim of this study was to provide mathematical descriptors for the border of pigmented skin lesion images and to assess their efficacy for distinction among different lesion groups. New descriptors such as lesion slope and lesion slope regularity are introduced and mathematically defined. A new algorithm based on t...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2003.815901

    authors: Grana C,Pellacani G,Cucchiara R,Seidenari S

    更新日期:2003-08-01 00:00:00

  • Precise robot-assisted guide positioning for distal locking of intramedullary nails.

    abstract::This paper presents a novel image-guided robot-based system to assist orthopedic surgeons in performing distal locking of long bone intramedullary nails. The system consists of a bone-mounted miniature robot fitted with a drill guide that provides rigid mechanical guidance for hand-held drilling of the distal screws' ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2005.844922

    authors: Yaniv Z,Joskowicz L

    更新日期:2005-05-01 00:00:00

  • Point-based rigid-body registration using an unscented Kalman filter.

    abstract::We present and validate a novel registration algorithm mapping two data sets, generated from a rigid object, in the presence of Gaussian noise. The proposed method is based on the Unscented Kalman Filter (UKF) algorithm that is generally employed for analyzing nonlinear systems corrupted by additive Gaussian noise. Fi...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/tmi.2007.901984

    authors: Moghari MH,Abolmaesumi P

    更新日期:2007-12-01 00:00:00

  • Parametric estimate of intensity inhomogeneities applied to MRI.

    abstract::This paper presents a new approach to the correction of intensity inhomogeneities in magnetic resonance imaging (MRI) that significantly improves intensity-based tissue segmentation. The distortion of the image brightness values by a low-frequency bias field impedes visual inspection and segmentation. The new correcti...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.845174

    authors: Styner M,Brechbühler C,Székely G,Gerig G

    更新日期:2000-03-01 00:00:00

  • Electrical impedance tomography using induced currents.

    abstract::The mathematical basis of a new imaging modality, induced current electrical impedance tomography (EIT), is investigated, The ultimate aim of this technique is the reconstruction of conductivity distribution of the human body, from voltage measurements made between electrodes placed on the surface, when currents are i...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.293927

    authors: Gencer NG,Kuzuoglu M,Ider YZ

    更新日期:1994-01-01 00:00:00

  • Electrical impedance spectroscopy of the breast: clinical imaging results in 26 subjects.

    abstract::Electrical impedance spectroscopy (EIS) is a potential, noninvasive technique to image women for breast cancer. Studies have shown characteristic frequency dispersions in the electrical conductivity and permittivity of malignant versus normal tissue. Using a multifrequency EIS system, we imaged the breasts of 26 women...

    journal_title:IEEE transactions on medical imaging

    pub_type: 临床试验,杂志文章

    doi:10.1109/tmi.2002.800606

    authors: Kerner TE,Paulsen KD,Hartov A,Soho SK,Poplack SP

    更新日期:2002-06-01 00:00:00

  • Vulnerable atherosclerotic plaque elasticity reconstruction based on a segmentation-driven optimization procedure using strain measurements: theoretical framework.

    abstract::It is now recognized that prediction of the vulnerable coronary plaque rupture requires not only an accurate quantification of fibrous cap thickness and necrotic core morphology but also a precise knowledge of the mechanical properties of plaque components. Indeed, such knowledge would allow a precise evaluation of th...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2009.2012852

    authors: Le Floc'h S,Ohayon J,Tracqui P,Finet G,Gharib AM,Maurice RL,Cloutier G,Pettigrew RI

    更新日期:2009-07-01 00:00:00

  • On Bayesian image reconstruction from projections: uniform and nonuniform a priori source information.

    abstract::A method that incorporates a priori uniform or nonuniform source distribution probabilistic information and data fluctuations of a Poisson nature is presented. The source distributions are modeled in terms of a priori source probability density functions. Maximum a posteriori probability solutions, as determined by a ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.34711

    authors: Liang Z,Jaszczak R,Greer K

    更新日期:1989-01-01 00:00:00

  • Globally convergent image reconstruction for emission tomography using relaxed ordered subsets algorithms.

    abstract::We present two types of globally convergent relaxed ordered subsets (OS) algorithms for penalized-likelihood image reconstruction in emission tomography: modified block sequential regularized expectation-maximization (BSREM) and relaxed OS separable paraboloidal surrogates (OS-SPS). The global convergence proof of the...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2003.812251

    authors: Ahn S,Fessler JA

    更新日期:2003-05-01 00:00:00

  • An investigation of methods of pileup rejection for 2-D array detectors employed in high resolution PET.

    abstract::Two methods of rejecting pileup events in 2-D array detectors used in positron emission tomography (PET) are investigated. Since the methods are based on different physical properties, they were investigated separately and in combination. Method one is based on the fact that valid events in the 2-D array detector occu...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.79481

    authors: Germano G,Hoffman EJ

    更新日期:1991-01-01 00:00:00

  • Separation of Metabolites and Macromolecules for Short-TE 1H-MRSI Using Learned Component-Specific Representations.

    abstract::Short-echo-time (TE) proton magnetic resonance spectroscopic imaging (MRSI) allows for simultaneously mapping a number of molecules in the brain, and has been recognized as an important tool for studying in vivo biochemistry in various neuroscience and disease applications. However, separation of the metabolite and ma...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2020.3048933

    authors: Li Y,Wang Z,Sun R,Lam F

    更新日期:2021-01-04 00:00:00

  • A hardware architecture using finite-field arithmetic for computing maximum-likelihood estimates in emission tomography.

    abstract::A special-purpose hardware architecture is proposed to implement the expectation-maximization algorithm to compute, in clinically useful times, the maximum-likelihood estimate of a radionuclide distribution for a positron-emission tomogram from time-of-flight measurements. Two-dimensional convolutions required for for...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.14510

    authors: Klotz HR,Snyder DL

    更新日期:1988-01-01 00:00:00

  • Unsupervised Domain Adaptation from Axial to Short-Axis Multi-Slice Cardiac MR Images by Incorporating Pretrained Task Networks.

    abstract::Anisotropic multi-slice Cardiac Magnetic Resonance (CMR) Images are conventionally acquired in patient-specific short-axis (SAX) orientation. In specific cardiovascular diseases that affect right ventricular (RV) morphology, acquisitions in standard axial (AX) orientation are preferred by some investigators, due to po...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2021.3052972

    authors: Koehler S,Hussain T,Blair Z,Huffaker T,Ritzmann F,Tandon A,Pickardt T,Sarikouch S,Sarikouch S,Latus H,Greil G,Wolf I,Engelhardt S

    更新日期:2021-01-20 00:00:00

  • Segmentation of the optic disc, macula and vascular arch in fundus photographs.

    abstract::An automatic system is presented to find the location of the major anatomical structures in color fundus photographs; the optic disc, the macula, and the vascular arch. These structures are found by fitting a single point-distribution-model to the image, that contains points on each structure. The method can handle op...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2006.885336

    authors: Niemeijer M,Abràmoff MD,van Ginneken B

    更新日期:2007-01-01 00:00:00

  • Semiautomated border tracking of cine echocardiographic ventnrcular images.

    abstract::Two-dimensional ultrasound sector scans of the left ventricle (LV) are commonly used to diagnose cardiac mechanical function. Present quantification procedures of wall motion by this technique entail inaccuracies, mainly due to relatively poor image quality and the absence of a definition of the relative position of t...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.1987.4307836

    authors: Adam D,Hareuveni O,Sideman S

    更新日期:1987-01-01 00:00:00

  • Multi-TI Arterial Spin Labeling MRI with Variable TR and Bolus Duration for Cerebral Blood Flow and Arterial Transit Time Mapping.

    abstract::Arterial spin labeling (ASL) is an MRI perfusion imaging method from which quantitative cerebral blood flow (CBF) can be calculated. We present a multi-TI ASL method (multi-TI integrated ASL) in which variable post-labeling delays and variable TRs are used to improve the estimation of arterial transit time (ATT) and C...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2015.2395257

    authors: Johnston ME,Lu K,Maldjian JA,Jung Y

    更新日期:2015-06-01 00:00:00

  • Prediction based collaborative trackers (PCT): a robust and accurate approach toward 3D medical object tracking.

    abstract::Robust and fast 3D tracking of deformable objects, such as heart, is a challenging task because of the relatively low image contrast and speed requirement. Many existing 2D algorithms might not be directly applied on the 3D tracking problem. The 3D tracking performance is limited due to dramatically increased data siz...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2011.2158440

    authors: Yang L,Georgescu B,Zheng Y,Wang Y,Meer P,Comaniciu D

    更新日期:2011-11-01 00:00:00

  • Improved SPECT quantitation using fully three-dimensional iterative spatially variant scatter response compensation.

    abstract::The quality and quantitative accuracy of iteratively reconstructed SPECT images improves when better point spread function (PSF) models of the gamma camera are used during reconstruction. Here, inclusion in the PSF model of photon crosstalk between different slices caused by limited gamma camera resolution and scatter...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.511752

    authors: Beekman FJ,Kamphuis C,Viergever MA

    更新日期:1996-01-01 00:00:00

  • Two iterative image restoration algorithms with applications to nuclear medicine.

    abstract::Two methods for recovering an image that has been degraded while being processed are presented. The restoration problem is formulated as a constrained optimization problem in which a measure of smoothness based on the second derivatives of the restored image is maximized subject to the constraint that noise energy is ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.126904

    authors: Charalambous C,Ghaddar FK,Kouris K

    更新日期:1992-01-01 00:00:00

  • Quantification of MR brain images by mixture density and partial volume modeling.

    abstract::The problem of automatic quantification of brain tissue by utilizing single-valued (single echo) magnetic resonance imaging (MRI) brain scans is addressed. It is shown that this problem can be solved without classification or segmentation, a method that may be particularly useful in quantifying white matter lesions wh...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.241885

    authors: Santago P,Gage HD

    更新日期:1993-01-01 00:00:00

  • Attention to Lesion: Lesion-Aware Convolutional Neural Network for Retinal Optical Coherence Tomography Image Classification.

    abstract::Automatic and accurate classification of retinal optical coherence tomography (OCT) images is essential to assist ophthalmologist in the diagnosis and grading of macular diseases. Clinically, ophthalmologists usually diagnose macular diseases according to the structures of macular lesions, whose morphologies, size, an...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2019.2898414

    authors: Fang L,Wang C,Li S,Rabbani H,Chen X,Liu Z

    更新日期:2019-08-01 00:00:00

  • Wavelet coding of volumetric medical datasets.

    abstract::Several techniques based on the three-dimensional (3-D) discrete cosine transform (DCT) have been proposed for volumetric data coding. These techniques fail to provide lossless coding coupled with quality and resolution scalability, which is a significant drawback for medical applications. This paper gives an overview...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/tmi.2003.809582

    authors: Schelkens P,Munteanu A,Barbarien J,Galca M,Giro-Nieto X,Cornelis J

    更新日期:2003-03-01 00:00:00