Electrical impedance spectroscopy of the breast: clinical imaging results in 26 subjects.

Abstract:

:Electrical impedance spectroscopy (EIS) is a potential, noninvasive technique to image women for breast cancer. Studies have shown characteristic frequency dispersions in the electrical conductivity and permittivity of malignant versus normal tissue. Using a multifrequency EIS system, we imaged the breasts of 26 women. All patients had mammograms ranked using the American College of Radiology (ACR) BIRADS system. Of the 51 individual breasts imaged, 38 were ACR 1 negative, six had ACR 4-5 suspicious lesions, and seven had ACR 2 benign findings such as fibroadenomas or calcifications. A radially translatable circular array of 16 Ag/AgCl electrodes was placed around the breast while the patient lay prone. We applied trigonometric voltage patterns at ten frequencies between 10 and 950 kHz. Anatomically coronal images were reconstructed from this data using nonlinear partial differential equation methods. Typically, ACR 1-rated breasts were interrogated in a single central plane whereas ACR 2-5-rated breasts were imaged in multiple planes covering the region of suspicion. In general, a characteristic homogeneous image emerged for mammographically normal cases while focal inhomogeneities were observed in images from women with malignancies. Using a specific visual criterion, EIS images identified 83% of the ACR 4-5 lesions while 67% were detected using a numerical criterion. Overall, multifrequency electrical impedance imaging appears promising for detecting breast malignancies, but improvements must be made before the method reaches its full potential.

journal_name

IEEE Trans Med Imaging

authors

Kerner TE,Paulsen KD,Hartov A,Soho SK,Poplack SP

doi

10.1109/tmi.2002.800606

subject

Has Abstract

pub_date

2002-06-01 00:00:00

pages

638-45

issue

6

eissn

0278-0062

issn

1558-254X

journal_volume

21

pub_type

临床试验,杂志文章
  • Anti-aliasing weighting functions for single-slice helical CT.

    abstract::Spatially variant longitudinal aliasing plagues most volumes reconstructed from single-slice helical computed tomography data, and its presence can degrade resolution and distort image structures. We have recently developed a Fourier-based approach to longitudinal interpolation in helical computed tomography that can,...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2002.803104

    authors: La Rivière PJ,Pan X

    更新日期:2002-08-01 00:00:00

  • Estimating kinetic parameter maps from dynamic contrast-enhanced MRI using spatial prior knowledge.

    abstract::Dynamic contrast-enhanced magnetic resonance (DCE-MR) imaging can be used to study microvascular structure in vivo by monitoring the abundance of an injected diffusible contrast agent over time. The resulting spatially resolved intensity-time curves are usually interpreted in terms of kinetic parameters obtained by fi...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2009.2019957

    authors: Kelm BM,Menze BH,Nix O,Zechmann CM,Hamprecht FA

    更新日期:2009-10-01 00:00:00

  • Sparse patch-based label propagation for accurate prostate localization in CT images.

    abstract::In this paper, we propose a new prostate computed tomography (CT) segmentation method for image guided radiation therapy. The main contributions of our method lie in the following aspects. 1) Instead of using voxel intensity information alone, patch-based representation in the discriminative feature space with logisti...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2012.2230018

    authors: Liao S,Gao Y,Lian J,Shen D

    更新日期:2013-02-01 00:00:00

  • Real-Time Gain Control of PET Detectors and Evaluation With Challenging Radionuclides.

    abstract::Accurate gain control of PET detectors is a prerequisite for quantitative accuracy. A shift in the 511 keV peak position can lead to errors in scatter correction, degrading quantitation. The PET detectors in a PET/MR scanner are subject to thermal transients due to eddy currents induced during gradient-intensive MRI s...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2020.3022321

    authors: Jansen FP,Deller TW,Fries MD,Khalighi MM,White SL,Radford LL,McConathy JE,Lapi SE

    更新日期:2021-01-01 00:00:00

  • An efficient optimization framework for multi-region segmentation based on Lagrangian duality.

    abstract::We introduce a multi-region model for simultaneous segmentation of medical images. In contrast to many other models, geometric constraints such as inclusion and exclusion between the regions are enforced, which makes it possible to correctly segment different regions even if the intensity distributions are identical. ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2012.2218117

    authors: Ulén J,Strandmark P,Kahl F

    更新日期:2013-02-01 00:00:00

  • Framework for Photon Counting Quantitative Material Decomposition.

    abstract::In this paper, the accuracy of material decomposition (MD) using an energy discriminating photon counting detector was studied. An MD framework was established and validated using calcium hydroxyapatite (CaHA) inserts of known densities (50 mg/cm3, 100 mg/cm3, 250 mg/cm3, 400 mg/cm3), and diameters (1.2, 3.0, and 5.0 ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2019.2914370

    authors: Juntunen MAK,Inkinen SI,Ketola JH,Kotiaho A,Kauppinen M,Winkler A,Nieminen MT

    更新日期:2020-01-01 00:00:00

  • Simultaneous Analysis of 2D Echo Views for Left Atrial Segmentation and Disease Detection.

    abstract::We propose a joint information approach for automatic analysis of 2D echocardiography (echo) data. The approach combines a priori images, their segmentations and patient diagnostic information within a unified framework to determine various clinical parameters, such as cardiac chamber volumes, and cardiac disease labe...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2016.2593900

    authors: Allan G,Nouranian S,Tsang T,Seitel A,Mirian M,Jue J,Hawley D,Fleming S,Gin K,Swift J,Rohling R,Abolmaesumi P

    更新日期:2017-01-01 00:00:00

  • Noise characterization of block-iterative reconstruction algorithms: II. Monte Carlo simulations.

    abstract::In Soares et al. (2000), the ensemble statistical properties of the rescaled block-iterative expectation-maximization (RBI-EM) reconstruction algorithm and rescaled block-iterative simultaneous multiplicative algebraic reconstruction technique (RBI-SMART) were derived. Included in this analysis were the special cases ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/tmi.2004.836876

    authors: Soares EJ,Glick SJ,Hoppin JW

    更新日期:2005-01-01 00:00:00

  • Bayesian approach for a robust speed-of-sound reconstruction using pulse-echo ultrasound.

    abstract::Computed ultrasound tomography in echo mode (CUTE) is a promising ultrasound (US) based multi-modal technique that allows to image the spatial distribution of speed of sound (SoS) inside tissue using hand-held pulse-echo US. It is based on measuring the phase shift of echoes when detected under varying steering angles...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2020.3029286

    authors: Stahli PS,Frenz M,Jaeger M

    更新日期:2020-10-07 00:00:00

  • Robust simultaneous detection of coronary borders in complex images.

    abstract::Visual estimation of coronary obstruction severity from angiograms suffers from poor inter- and intraobserver reproducibility and is often inaccurate. In spite of the widely recognized limitations of visual analysis, automated methods have not found widespread clinical use, in part because they too frequently fail to ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.370412

    authors: Sonka M,Winniford MD,Collins SM

    更新日期:1995-01-01 00:00:00

  • 2.5-D simultaneous multislice reconstruction by series expansion methods from Fourier-rebinned PET data.

    abstract::True three-dimensional (3-D) volume reconstruction from fully 3-D data in positron emission tomography (PET) has only a limited clinical use because of its large computational burden. Fourier rebinning (FORE) of the fully 3-D data into a set of 2-D sinogram data decomposes the 3-D reconstruction process into multiple ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.870257

    authors: Obi T,Matej S,Lewitt RM,Herman GT

    更新日期:2000-05-01 00:00:00

  • Online Combination of EPID & Cherenkov Imaging for 3-D Dosimetry in a Liquid Phantom.

    abstract::Online acquisition of Cherenkov and portal imaging data was combined with a reconstruction scheme called EC3-D, providing a full 3-D dosimetry of megavoltage X-ray beams in a water tank. The methodology was demonstrated and quantified in a single static beam. Furthermore, the dynamics and visualization of the 3-D dose...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2017.2717800

    authors: Bruza P,Andreozzi JM,Gladstone DJ,Jarvis LA,Rottmann J,Pogue BW

    更新日期:2017-10-01 00:00:00

  • Scale-based diffusive image filtering preserving boundary sharpness and fine structures.

    abstract::Image acquisition techniques often suffer from low signal-to-noise ratio (SNR) and/or contrast-to-noise ratio (CNR). Although many acquisition techniques are available to minimize these, post acquisition filtering is a major off-line image processing technique commonly used to improve the SNR and CNR. A major drawback...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.963817

    authors: Saha PK,Udupa JK

    更新日期:2001-11-01 00:00:00

  • Noninvasive Reconstruction of Transmural Transmembrane Potential With Simultaneous Estimation of Prior Model Error.

    abstract::To reconstruct electrical activity in the heart from body-surface electrocardiograms (ECGs) is an ill-posed inverse problem. Electrophysiological models have been found effective in regularizing these inverse problems by incorporating a priori knowledge about how the electrical potential in the heart propagates over t...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2019.2906600

    authors: Ghimire S,Sapp JL,Horacek BM,Wang L

    更新日期:2019-11-01 00:00:00

  • Multiscale AM-FM methods for diabetic retinopathy lesion detection.

    abstract::In this paper, we propose the use of multiscale amplitude-modulation-frequency-modulation (AM-FM) methods for discriminating between normal and pathological retinal images. The method presented in this paper is tested using standard images from the early treatment diabetic retinopathy study. We use 120 regions of 40 x...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2009.2037146

    authors: Agurto C,Murray V,Barriga E,Murillo S,Pattichis M,Davis H,Russell S,Abramoff M,Soliz P

    更新日期:2010-02-01 00:00:00

  • Narrowband magnetic particle imaging.

    abstract::The magnetic particle imaging (MPI) method directly images the magnetization of super-paramagnetic iron oxide (SPIO) nanoparticles, which are contrast agents commonly used in magnetic resonance imaging (MRI). MPI, as originally envisioned, requires a high-bandwidth receiver coil and preamplifier, which are difficult t...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2009.2013849

    authors: Goodwill PW,Scott GC,Stang PP,Conolly SM

    更新日期:2009-08-01 00:00:00

  • Image Registration Based on Low Rank Matrix: Rank-Regularized SSD.

    abstract::Similarity measure is a main core of image registration algorithms. Spatially varying intensity distortion is an important challenge, which affects the performance of similarity measures. Correlation among the pixels is the main characteristic of this distortion. Similarity measures such as sum-of-squared-differences ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2017.2744663

    authors: Ghaffari A,Fatemizadeh E

    更新日期:2018-01-01 00:00:00

  • Vessel surface reconstruction with a tubular deformable model.

    abstract::Three-dimensional (3-D) angiographic methods are gaining acceptance for evaluation of atherosclerotic disease. However, measurement of vessel stenosis from 3-D angiographic methods can be problematic due to limited image resolution and contrast. We present a method for reconstructing vessel surfaces from 3-D angiograp...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.974935

    authors: Yim PJ,Cebral JJ,Mullick R,Marcos HB,Choyke PL

    更新日期:2001-12-01 00:00:00

  • Robust parameter estimation of intensity distributions for brain magnetic resonance images.

    abstract::This paper presents two new methods for robust parameter estimation of mixtures in the context of magnetic resonance (MR) data segmentation. The head is constituted of different types of tissue that can be modeled by a finite mixture of multivariate Gaussian distributions. Our goal is to estimate accurately the statis...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.700730

    authors: Schroeter P,Vesin JM,Langenberger T,Meuli R

    更新日期:1998-04-01 00:00:00

  • Quantifying the statistical impact of GRAPPA in fcMRI data with a real-valued isomorphism.

    abstract::The interpolation of missing spatial frequencies through the generalized auto-calibrating partially parallel acquisitions (GRAPPA) parallel magnetic resonance imaging (MRI) model implies a correlation is induced between the acquired and reconstructed frequency measurements. As the parallel image reconstruction algorit...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2013.2288521

    authors: Bruce IP,Rowe DB

    更新日期:2014-02-01 00:00:00

  • REDMAPS: reduced-dimensionality matching for prostate brachytherapy seed reconstruction.

    abstract::The success of prostate brachytherapy critically depends on delivering adequate dose to the prostate gland. Intraoperative localization of the implanted seeds provides potential for dose evaluation and optimization during therapy. A reduced-dimensionality matching algorithm for prostate brachytherapy seed reconstructi...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2010.2059709

    authors: Lee J,Labat C,Jain AK,Song DY,Burdette EC,Fichtinger G,Prince JL

    更新日期:2011-01-01 00:00:00

  • Automated characterization of breast lesions imaged with an ultrafast DCE-MR protocol.

    abstract::Dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) of the breast has become an invaluable tool in the clinical work-up of patients suspected of having breast carcinoma. The purpose of this study is to introduce novel features extracted from the kinetics of contrast agent uptake imaged by a short (100 s) vi...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2013.2281984

    authors: Platel B,Mus R,Welte T,Karssemeijer N,Mann R

    更新日期:2014-02-01 00:00:00

  • Adaptive Clutter Demodulation for Non-Contrast Ultrasound Perfusion Imaging.

    abstract::Conventional Doppler ultrasound is useful for visualizing fast blood flow in large resolvable vessels. However, frame rate and tissue clutter caused by movement of the patient or sonographer make visualizing slow flow with ultrasound difficult. Patient and sonographer motion causes spectral broadening of the clutter s...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2017.2714901

    authors: Tierney J,Coolbaugh C,Towse T,Byram B

    更新日期:2017-09-01 00:00:00

  • Accelerating parallel transmit array B1 mapping in high field MRI with slice undersampling and interpolation by kriging.

    abstract::Transmit arrays have been developed to mitigate the RF field inhomogeneity commonly observed in high field magnetic resonance imaging (MRI), typically above 3T. To this end, the knowledge of the RF complex-valued B1 transmit-sensitivities of each independent radiating element has become essential. This paper details a...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2014.2322440

    authors: Ferrand G,Luong M,Cloos MA,Amadon A,Wackernagel H

    更新日期:2014-08-01 00:00:00

  • Precise robot-assisted guide positioning for distal locking of intramedullary nails.

    abstract::This paper presents a novel image-guided robot-based system to assist orthopedic surgeons in performing distal locking of long bone intramedullary nails. The system consists of a bone-mounted miniature robot fitted with a drill guide that provides rigid mechanical guidance for hand-held drilling of the distal screws' ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2005.844922

    authors: Yaniv Z,Joskowicz L

    更新日期:2005-05-01 00:00:00

  • Robust super-resolution volume reconstruction from slice acquisitions: application to fetal brain MRI.

    abstract::Fast magnetic resonance imaging slice acquisition techniques such as single shot fast spin echo are routinely used in the presence of uncontrollable motion. These techniques are widely used for fetal magnetic resonance imaging (MRI) and MRI of moving subjects and organs. Although high-quality slices are frequently acq...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2010.2051680

    authors: Gholipour A,Estroff JA,Warfield SK

    更新日期:2010-10-01 00:00:00

  • 3D Statistical Shape Models Incorporating Landmark-Wise Random Regression Forests for Omni-Directional Landmark Detection.

    abstract::3D Statistical Shape Models (3D-SSM) are widely used for medical image segmentation. However, during segmentation, they typically perform a very limited unidirectional search for suitable landmark positions in the image, relying on weak learners or use-case specific appearance models that solely take local image infor...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2016.2600502

    authors: Norajitra T,Maier-Hein KH

    更新日期:2017-01-01 00:00:00

  • Shielded microstrip array for 7T human MR imaging.

    abstract::The high-frequency transceiver array based on the microstrip transmission line design is a promising technique for ultrahigh field magnetic resonance imaging (MRI) signal excitation and reception. However, with the increase of radio-frequency (RF) channels, the size of the ground plane in each microstrip coil element ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2009.2033597

    authors: Wu B,Wang C,Kelley DA,Xu D,Vigneron DB,Nelson SJ,Zhang X

    更新日期:2010-01-01 00:00:00

  • Geometric modeling of the human normal cerebral arterial system.

    abstract::We propose an anatomy-based approach for an efficient construction of a three-dimensional human normal cerebral arterial model from segmented and skeletonized angiographic data. The centerline-based model is used for an accurate angiographic data representation. A vascular tree is represented by tubular segments and b...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/tmi.2005.845041

    authors: Volkau I,Zheng W,Baimouratov R,Aziz A,Nowinski WL

    更新日期:2005-04-01 00:00:00

  • Learning-based deformable registration of MR brain images.

    abstract::This paper presents a learning-based method for deformable registration of magnetic resonance (MR) brain images. There are two novelties in the proposed registration method. First, a set of best-scale geometric features are selected for each point in the brain, in order to facilitate correspondence detection during th...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/tmi.2006.879320

    authors: Wu G,Qi F,Shen D

    更新日期:2006-09-01 00:00:00