Abstract:
:In this paper, we propose the use of multiscale amplitude-modulation-frequency-modulation (AM-FM) methods for discriminating between normal and pathological retinal images. The method presented in this paper is tested using standard images from the early treatment diabetic retinopathy study. We use 120 regions of 40 x 40 pixels containing four types of lesions commonly associated with diabetic retinopathy (DR) and two types of normal retinal regions that were manually selected by a trained analyst. The region types included microaneurysms, exudates, neovascularization on the retina, hemorrhages, normal retinal background, and normal vessels patterns. The cumulative distribution functions of the instantaneous amplitude, the instantaneous frequency magnitude, and the relative instantaneous frequency angle from multiple scales are used as texture feature vectors. We use distance metrics between the extracted feature vectors to measure interstructure similarity. Our results demonstrate a statistical differentiation of normal retinal structures and pathological lesions based on AM-FM features. We further demonstrate our AM-FM methodology by applying it to classification of retinal images from the MESSIDOR database. Overall, the proposed methodology shows significant capability for use in automatic DR screening.
journal_name
IEEE Trans Med Imagingjournal_title
IEEE transactions on medical imagingauthors
Agurto C,Murray V,Barriga E,Murillo S,Pattichis M,Davis H,Russell S,Abramoff M,Soliz Pdoi
10.1109/TMI.2009.2037146subject
Has Abstractpub_date
2010-02-01 00:00:00pages
502-12issue
2eissn
0278-0062issn
1558-254Xjournal_volume
29pub_type
杂志文章abstract::The magnetic particle imaging (MPI) method directly images the magnetization of super-paramagnetic iron oxide (SPIO) nanoparticles, which are contrast agents commonly used in magnetic resonance imaging (MRI). MPI, as originally envisioned, requires a high-bandwidth receiver coil and preamplifier, which are difficult t...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2009.2013849
更新日期:2009-08-01 00:00:00
abstract::We suggest a polynomial program for the calculation of optimized gradient waveforms for magnetic resonance tomography pulse sequences. Such non-linear mathematical programs can describe gradient system capabilities, meet k-space trajectory specifications, and capture sequence timing conditions. Moreover they allow the...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2010.2042723
更新日期:2010-06-01 00:00:00
abstract::Bronchoscopy is a major step in lung cancer staging. To perform bronchoscopy, the physician uses a procedure plan, derived from a patient's 3D computed-tomography (CT) chest scan, to navigate the bronchoscope through the lung airways. Unfortunately, physicians vary greatly in their ability to perform bronchoscopy. As ...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2013.2252361
更新日期:2013-08-01 00:00:00
abstract::We propose a conceptually simple framework for fast COVID-19 screening in 3D chest CT images. The framework can efficiently predict whether or not a CT scan contains pneumonia while simultaneously identifying pneumonia types between COVID-19 and Interstitial Lung Disease (ILD) caused by other viruses. In the proposed ...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2020.2994908
更新日期:2020-08-01 00:00:00
abstract::Microwave radar imaging is promising as a complementary medical imaging modality. However, the unique nature of the images means interpretation can be difficult. As a result, it is important to understand the sources of image differences, and how much variability is inherent in the imaging system itself. To address th...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2018.2806878
更新日期:2018-08-01 00:00:00
abstract::Peripheral Nerve Stimulation (PNS) limits the acquisition rate of Magnetic Resonance Imaging data for fast sequences employing powerful gradient systems. The PNS characteristics are currently assessed after the coil design phase in experimental stimulation studies using constructed coil prototypes. This makes it diffi...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2020.3023329
更新日期:2021-01-01 00:00:00
abstract::We are presenting data from the largest clinical trial on optical tomographic imaging of finger joints to date. Overall we evaluated 99 fingers of patients affected by rheumatoid arthritis (RA) and 120 fingers from healthy volunteers. Using frequency-domain imaging techniques we show that sensitivities and specificiti...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2011.2135374
更新日期:2011-10-01 00:00:00
abstract::In magnetic resonance imaging (MRI), it is well-known that patient motion plays a significant role in the degradation of image quality. Although the case of translational in-plane motion (x-y-motion) has been studied by several researchers, the effect of rigid, translational out-of-plane motion (z-motion) has not yet ...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.414611
更新日期:1995-01-01 00:00:00
abstract::This paper presents a preconditioned Krasnoselskii-Mann (KM) algorithm with an improved EM preconditioner (IEM-PKMA) for higher-order total variation (HOTV) regularized positron emission tomography (PET) image reconstruction. The PET reconstruction problem can be formulated as a three-term convex optimization model co...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2019.2898271
更新日期:2019-09-01 00:00:00
abstract::High-resolution X-ray computed tomography (CT) imaging is routinely used for clinical pulmonary applications. Since lung function varies regionally and because pulmonary disease is usually not uniformly distributed in the lungs, it is useful to study the lungs on a lobe-by-lobe basis. Thus, it is important to segment ...
journal_title:IEEE transactions on medical imaging
pub_type: 临床试验,杂志文章
doi:10.1109/TMI.2005.859209
更新日期:2006-01-01 00:00:00
abstract::Monte Carlo (MC) simulation provides a flexible and robust framework to efficiently evaluate and optimize image processing methods in emission tomography. In this work we present Brain-VISET (Voxel-based Iterative Simulation for Emission Tomography), a method that aims to simulate realistic [ (99m) Tc]-SPECT and [ (18...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2014.2326041
更新日期:2014-10-01 00:00:00
abstract::A numerical method for microwave imaging of two-dimensional inhomogeneous biological bodies illuminated by TM waves is presented. It is a spatial-domain multiview approach which makes use of the moment method to discretize the integral-equation formulation of inverse scattering. A pseudoinversion technique is applied ...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.232251
更新日期:1993-01-01 00:00:00
abstract::Alzheimer's disease (AD) is a serious neurodegenerative condition that affects millions of individuals across the world. As the average age of individuals in the United States and the world increases, the prevalence of AD will continue to grow. To address this public health problem, the research community has develope...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2019.2958943
更新日期:2020-06-01 00:00:00
abstract::The presence of high-density objects remains an open problem in medical CT imaging. Data of projections passing through objects of high density, such as metal implants, are dominated by noise and are highly affected by beam hardening and scatter. Reconstructed images become less diagnostically conclusive because of pr...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2015.2459764
更新日期:2016-01-01 00:00:00
abstract::The response characteristics of two tomographic systems were compared for imaging of positron emitters: a) a SPECT system with a 3/8 in crystal and 511 keV detector shielding, equipped with a specially designed 511 keV collimator, and b) a PET V system using coincidence detection. SPECT transverse plane resolution was...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.1986.4307776
更新日期:1986-01-01 00:00:00
abstract::Small pulmonary nodules are a common radiographic finding that presents an important diagnostic challenge in contemporary medicine. While pulmonary nodules are the major radiographic indicator of lung cancer, they may also be signs of a variety of benign conditions. Measurement of nodule growth rate over time has been...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2003.817785
更新日期:2003-10-01 00:00:00
abstract::3D Statistical Shape Models (3D-SSM) are widely used for medical image segmentation. However, during segmentation, they typically perform a very limited unidirectional search for suitable landmark positions in the image, relying on weak learners or use-case specific appearance models that solely take local image infor...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2016.2600502
更新日期:2017-01-01 00:00:00
abstract::Diffusion tensor imaging is widely used in brain connectivity research. As more and more studies recruit large numbers of subjects, it is important to design registration methods which are not only theoretically rigorous, but also computationally efficient. However, the requirement of reorienting diffusion tensors com...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2013.2274051
更新日期:2014-05-01 00:00:00
abstract::An automatic method has been developed for segmentation of abdominal computed tomography (CT) images for virtual colonoscopy obtained after a bowel preparation of a low-residue diet with ingested contrast solutions to enhance the image intensities of residual colonic materials. Removal of the enhanced materials was pe...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.897814
更新日期:2000-12-01 00:00:00
abstract::Imaging systems that form estimates using a statistical approach generally yield images with nonuniform resolution properties. That is, the reconstructed images possess resolution properties marked by space-variant and/or anisotropic responses. We have previously developed a space-variant penalty for penalized-likelih...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2003.823063
更新日期:2004-03-01 00:00:00
abstract::A new postprocessing algorithm was developed for the diagnosis of breast cancer using electrical impedance scanning. This algorithm automatically recognizes bright focal spots in the conductivity map of the breast. Moreover, this algorithm discriminates between malignant and benign/normal tissues using two main predic...
journal_title:IEEE transactions on medical imaging
pub_type: 信件
doi:10.1109/TMI.2002.800605
更新日期:2002-06-01 00:00:00
abstract::Micro-computed tomography (micro-CT) has been widely used to generate high-resolution 3-D tissue images from small animals nondestructively, especially for mineralized skeletal tissues. However, its application to the analysis of soft cardiovascular tissues has been limited by poor inter-tissue contrast. Recent ex viv...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2012.2209183
更新日期:2013-01-01 00:00:00
abstract::In this paper, we propose a novel deep learning framework for anatomy segmentation and automatic landmarking. Specifically, we focus on the challenging problem of mandible segmentation from cone-beam computed tomography (CBCT) scans and identification of 9 anatomical landmarks of the mandible on the geodesic space. Th...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2018.2875814
更新日期:2019-04-01 00:00:00
abstract::We describe a fast forward and back projector pair based on inverse Fourier rebinning for use in iterative image reconstruction for fully three-dimensional (3-D) positron emission tomography (PET). The projector pair is used as part of a factored system matrix that takes into account detector-pair response by using sh...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:
更新日期:2007-03-01 00:00:00
abstract::Several technologies for characterizing genes and proteins from humans and other organisms use yeast growth or color development as read outs. The yeast two-hybrid assay, for example, detects protein-protein interactions by measuring the growth of yeast on a specific solid medium, or the ability of the yeast to change...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2007.900694
更新日期:2007-10-01 00:00:00
abstract::Cerebral ischemic stroke causes injury to brain tissue characterized by a complex cascade of neuronal and vascular events. Imaging during the early stages of its development allows prediction of tissue infarction and penumbra so that optimal intervention can be determined in order to salvage brain function impairment....
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2019.2895779
更新日期:2019-06-01 00:00:00
abstract::Since the invention of diffusion magnetic resonance imaging (dMRI), currently the only established method for studying white matter connectivity in a clinical environment, there has been a great deal of interest in the effects of various pathologies on the connectivity of the brain. As methods for in vivo tractography...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2007.905826
更新日期:2007-11-01 00:00:00
abstract::Plane-wave-based ultrafast imaging has become the prevalent technique for non-conventional ultrasound imaging. The image quality, especially in terms of the suppression of artifacts, is generally compromised by reducing the number of transmissions for a higher frame rate. We hereby propose a new ultrafast imaging fram...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2017.2736423
更新日期:2018-02-01 00:00:00
abstract::A common challenge when performing surface-based registration of images is ensuring that the surfaces accurately represent consistent anatomical boundaries. Image segmentation may be difficult in some regions due to either poor contrast, low slice resolution, or tissue ambiguities. To address this, we present a novel ...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2015.2443978
更新日期:2015-12-01 00:00:00
abstract::The segmentation of the human airway tree from volumetric computed tomography (CT) images builds an important step for many clinical applications and for physiological studies. Previously proposed algorithms suffer from one or several problems: leaking into the surrounding lung parenchyma, the need for the user to man...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2005.857654
更新日期:2005-12-01 00:00:00