Reconstruction of dielectric permittivity distributions in arbitrary 2-D inhomogeneous biological bodies by a multiview microwave numerical method.

Abstract:

:A numerical method for microwave imaging of two-dimensional inhomogeneous biological bodies illuminated by TM waves is presented. It is a spatial-domain multiview approach which makes use of the moment method to discretize the integral-equation formulation of inverse scattering. A pseudoinversion technique is applied to obtain a minimum-norm solution for the equivalent current density inside the cross-section of a scatterer. A multi-illumination-angle multiview process is used. The invariance of the Green matrix makes it possible to perform only one pseudoinverse (off line and once for all), independently of the number of views, thus reducing the need for computer resources. A pixel representation is adopted, and a look-up table is utilized to fast synthesize images. No plane-wave illumination is required and no first-order approximations are applied. Distortions in the dielectric reconstruction and noise effects are evaluated via some numerical simulations.

journal_name

IEEE Trans Med Imaging

authors

Caorsi S,Gragnani GL,Pastorino M

doi

10.1109/42.232251

subject

Has Abstract

pub_date

1993-01-01 00:00:00

pages

232-9

issue

2

eissn

0278-0062

issn

1558-254X

journal_volume

12

pub_type

杂志文章
  • Robust super-resolution volume reconstruction from slice acquisitions: application to fetal brain MRI.

    abstract::Fast magnetic resonance imaging slice acquisition techniques such as single shot fast spin echo are routinely used in the presence of uncontrollable motion. These techniques are widely used for fetal magnetic resonance imaging (MRI) and MRI of moving subjects and organs. Although high-quality slices are frequently acq...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2010.2051680

    authors: Gholipour A,Estroff JA,Warfield SK

    更新日期:2010-10-01 00:00:00

  • Accurate event-driven motion compensation in high-resolution PET incorporating scattered and random events.

    abstract::With continuing improvements in spatial resolution of positron emission tomography (PET) scanners, small patient movements during PET imaging become a significant source of resolution degradation. This work develops and investigates a comprehensive formalism for accurate motion-compensated reconstruction which at the ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2008.917248

    authors: Rahmim A,Dinelle K,Cheng JC,Shilov MA,Segars WP,Lidstone SC,Blinder S,Rousset OG,Vajihollahi H,Tsui BM,Wong DF,Sossi V

    更新日期:2008-08-01 00:00:00

  • Self-stabilizing colonic capsule endoscopy: pilot study of acute canine models.

    abstract::Video capsule endoscopy (VCE) is a noninvasive method for examining the gastrointestinal tract which has been successful in small intestine studies. Recently, VCE has been attempted in the colon. However, the capsule often tumbles in the wider colonic lumen, resulting in missed regions. Self-stabilizing VCE is a novel...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2011.2163165

    authors: Filip D,Yadid-Pecht O,Andrews CN,Mintchev MP

    更新日期:2011-12-01 00:00:00

  • Surface Reconstruction for free-space 360 degrees fluorescence molecular tomography and the effects of animal motion.

    abstract::Complete projection (360 degrees ) free-space fluorescence tomography of opaque media is poised to enable 3-D imaging through entire small animals in vivo with improved depth resolution compared to 360 degrees -projection fiber-based systems or limited-view angle systems. This approach can lead to a new generation of ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2007.904662

    authors: Lasser T,Soubret A,Ripoll J,Ntziachristos V

    更新日期:2008-02-01 00:00:00

  • Red Lesion Detection Using Dynamic Shape Features for Diabetic Retinopathy Screening.

    abstract::The development of an automatic telemedicine system for computer-aided screening and grading of diabetic retinopathy depends on reliable detection of retinal lesions in fundus images. In this paper, a novel method for automatic detection of both microaneurysms and hemorrhages in color fundus images is described and va...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2015.2509785

    authors: Seoud L,Hurtut T,Chelbi J,Cheriet F,Langlois JM

    更新日期:2016-04-01 00:00:00

  • Prospective Respiration Detection in Magnetic Resonance Imaging by a Non-Interfering Noise Navigator.

    abstract::Passive monitoring of the thermal noise variances of the channels of a receive array was shown to reveal respiratory motion of the underlying anatomy, a so called "noise navigator". There is, however, an inevitable trade off between the accuracy and temporal resolution of the noise navigator due to its passive nature....

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2018.2808699

    authors: Navest RJM,Andreychenko A,Lagendijk JJW,van den Berg CAT

    更新日期:2018-08-01 00:00:00

  • A wavelet-based multiresolution regularized least squares reconstruction approach for optical tomography.

    abstract::In this paper, we present a wavelet-based multigrid approach to solve the perturbation equation encountered in optical tomography. With this scheme, the unknown image, the data, as well as the weight matrix are all represented by wavelet expansions, thus yielding a multiresolution representation of the original pertur...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.563666

    authors: Zhu W,Wang Y,Deng Y,Yao Y,Barbour RL

    更新日期:1997-04-01 00:00:00

  • Estimation of Strain Elastography from Ultrasound Radio-Frequency Data by Utilizing Analytic Gradient of the Similarity Metric.

    abstract::Most strain imaging techniques follow a pipeline strategy: in the first step, tissue displacement is estimated from radio-frequency (RF) frames, and in the second step, a spatial derivative operation is applied. There are two main issues that arise from this framework. First, the gradient operation amplifies noise, an...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2017.2685522

    authors: Omidyeganeh M,Xiao Y,Ahmad MO,Rivaz H

    更新日期:2017-06-01 00:00:00

  • Edge displacement field-based classification for improved detection of polyps in CT colonography.

    abstract::Colorectal cancer can easily be prevented provided that the precursors to tumors, small colonic polyps, are detected and removed. Currently, the only definitive examination of the colon is fiber-optic colonoscopy, which is invasive and expensive. Computed tomographic colonography (CTC) is potentially a less costly and...

    journal_title:IEEE transactions on medical imaging

    pub_type: 临床试验,杂志文章

    doi:10.1109/TMI.2002.806405

    authors: Acar B,Beaulieu CF,Göktürk SB,Tomasi C,Paik DS,Jeffrey RB Jr,Yee J,Napel S

    更新日期:2002-12-01 00:00:00

  • Online Combination of EPID & Cherenkov Imaging for 3-D Dosimetry in a Liquid Phantom.

    abstract::Online acquisition of Cherenkov and portal imaging data was combined with a reconstruction scheme called EC3-D, providing a full 3-D dosimetry of megavoltage X-ray beams in a water tank. The methodology was demonstrated and quantified in a single static beam. Furthermore, the dynamics and visualization of the 3-D dose...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2017.2717800

    authors: Bruza P,Andreozzi JM,Gladstone DJ,Jarvis LA,Rottmann J,Pogue BW

    更新日期:2017-10-01 00:00:00

  • Ovarian ultrasound image analysis: follicle segmentation.

    abstract::Ovarian ultrasound is an effective tool in infertility treatment. Repeated measurements of the size and shape of follicles over several days are the primary means of evaluation by physicians. Currently, follicle wall segmentation is achieved by manual tracing which is time consuming and susceptible to inter-operator v...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.746626

    authors: Krivanek A,Sonka M

    更新日期:1998-12-01 00:00:00

  • A comprehensive cardiac motion estimation framework using both untagged and 3-D tagged MR images based on nonrigid registration.

    abstract::In this paper, we present a novel technique based on nonrigid image registration for myocardial motion estimation using both untagged and 3-D tagged MR images. The novel aspect of our technique is its simultaneous usage of complementary information from both untagged and 3-D tagged MR images. To estimate the motion wi...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2012.2188104

    authors: Shi W,Zhuang X,Wang H,Duckett S,Luong DV,Tobon-Gomez C,Tung K,Edwards PJ,Rhode KS,Razavi RS,Ourselin S,Rueckert D

    更新日期:2012-06-01 00:00:00

  • Simultaneous Estimation of Corneal Topography, Pachymetry, and Curvature.

    abstract::Identification of objective criteria to correctly diagnose ectatic diseases of the cornea or to detect early stages of corneal ectasia is of great interest in ophthalmology and optometry. Metrics for diagnosis typically employed are curvature maps (axial/sagittal, tangential); elevation map of the anterior surface of ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2018.2836304

    authors: Nasrin F,Iyer RV,Mathews SM

    更新日期:2018-11-01 00:00:00

  • Model-based MR parameter mapping with sparsity constraints: parameter estimation and performance bounds.

    abstract::Magnetic resonance parameter mapping (e.g., T1 mapping, T2 mapping, T*2 mapping) is a valuable tool for tissue characterization. However, its practical utility has been limited due to long data acquisition time. This paper addresses this problem with a new model-based parameter mapping method. The proposed method util...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2014.2322815

    authors: Zhao B,Lam F,Liang ZP

    更新日期:2014-09-01 00:00:00

  • BICAV: a block-iterative parallel algorithm for sparse systems with pixel-related weighting.

    abstract::Component averaging (CAV) was recently introduced by Censor, Gordon, and Gordon as a new iterative parallel technique suitable for large and sparse unstructured systems of linear equations. Based on earlier work of Byrne and Censor, it uses diagonal weighting matrices, with pixel-related weights determined by the spar...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.959302

    authors: Censor Y,Gordon D,Gordon R

    更新日期:2001-10-01 00:00:00

  • Head Motion Correction Based on Filtered Backprojection in Helical CT Scanning.

    abstract::Head motion may unexpectedly occur during a CT scan. It thereby results in motion artifacts in a reconstructed image and may lead to a false diagnosis or a failure of diagnosis. To alleviate this motion problem, as a hardware approach, increasing the gantry rotation speed or using an immobilization device is usually c...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2019.2953974

    authors: Jang S,Kim S,Kim M,Son K,Lee KY,Ra JB

    更新日期:2020-05-01 00:00:00

  • An Inverse Problems Approach to MR-EPT Image Reconstruction.

    abstract::Magnetic Resonance-Electrical Properties Tomography (MR-EPT) is an imaging modality that maps the spatial distribution of the electrical conductivity and permittivity using standard MRI systems. The presence of a body within the scanner alters the RF field, and by mapping these alterations it is possible to recover th...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2015.2466082

    authors: Borsic A,Perreard I,Mahara A,Halter RJ

    更新日期:2016-01-01 00:00:00

  • Robust online orientation correction for radiographs in PACS environments.

    abstract::In picture archiving and communications systems (PACS), images need to be displayed in standardized ways for radiologists' interpretations. However, for most radiographs acquired via computed radiography (CR), digital radiography (DR), or digitized films, the image orientation is undetermined because of the variations...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/tmi.2006.880677

    authors: Luo H,Luo J

    更新日期:2006-10-01 00:00:00

  • Quantitative analysis of cardiac tissue including fibroblasts using three-dimensional confocal microscopy and image reconstruction: towards a basis for electrophysiological modeling.

    abstract::Electrophysiological modeling of cardiac tissue is commonly based on functional and structural properties measured in experiments. Our knowledge of these properties is incomplete, in particular their remodeling in disease. Here, we introduce a methodology for quantitative tissue characterization based on fluorescent l...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2013.2240693

    authors: Schwab BC,Seemann G,Lasher RA,Torres NS,Wulfers EM,Arp M,Carruth ED,Bridge JH,Sachse FB

    更新日期:2013-05-01 00:00:00

  • Exact frequency-domain reconstruction for thermoacoustic tomography--II: Cylindrical geometry.

    abstract::Microwave-induced thermoacoustic tomography (TAT) in a cylindrical configuration is developed to image biological tissue. Thermoacoustic signals are acquired by scanning a flat ultrasonic transducer. Using a new expansion of a spherical wave in cylindrical coordinates, we apply the Fourier and Hankel transforms to TAT...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2002.801171

    authors: Xu Y,Xu M,Wang LV

    更新日期:2002-07-01 00:00:00

  • Compressed Sensing Reconstruction of 3D Ultrasound Data Using Dictionary Learning and Line-Wise Subsampling.

    abstract::In this paper we present a compressed sensing (CS) method adapted to 3D ultrasound imaging (US). In contrast to previous work, we propose a new approach based on the use of learned overcomplete dictionaries that allow for much sparser representations of the signals since they are optimized for a particular class of im...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2015.2442154

    authors: Lorintiu O,Liebgott H,Alessandrini M,Bernard O,Friboulet D

    更新日期:2015-12-01 00:00:00

  • Accurate localization of optic radiation during neurosurgery in an interventional MRI suite.

    abstract::Accurate localization of the optic radiation is key to improving the surgical outcome for patients undergoing anterior temporal lobe resection for the treatment of refractory focal epilepsy. Current commercial interventional magnetic resonance imaging (MRI) scanners are capable of performing anatomical and diffusion w...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2011.2179668

    authors: Daga P,Winston G,Modat M,White M,Mancini L,Cardoso MJ,Symms M,Stretton J,McEvoy AW,Thornton J,Micallef C,Yousry T,Hawkes DJ,Duncan JS,Ourselin S

    更新日期:2012-04-01 00:00:00

  • Digital mammography: mixed feature neural network with spectral entropy decision for detection of microcalcifications.

    abstract::A computationally efficient mixed feature based neural network (MFNN) is proposed for the detection of microcalcification clusters (MCCs) in digitized mammograms. The MFNN employs features computed in both the spatial and spectral domain and uses spectral entropy as a decision parameter. Backpropagation with Kalman fi...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.538936

    authors: Zheng B,Qian W,Clarke LP

    更新日期:1996-01-01 00:00:00

  • CA-Net: Comprehensive Attention Convolutional Neural Networks for Explainable Medical Image Segmentation.

    abstract::Accurate medical image segmentation is essential for diagnosis and treatment planning of diseases. Convolutional Neural Networks (CNNs) have achieved state-of-the-art performance for automatic medical image segmentation. However, they are still challenged by complicated conditions where the segmentation target has lar...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2020.3035253

    authors: Gu R,Wang G,Song T,Huang R,Aertsen M,Deprest J,Ourselin S,Vercauteren T,Zhang S

    更新日期:2020-11-02 00:00:00

  • Singular vectors of a linear imaging system as efficient channels for the bayesian ideal observer.

    abstract::The Bayesian ideal observer provides an absolute upper bound for diagnostic performance of an imaging system and hence should be used for the assessment of image quality whenever possible. However, computation of ideal-observer performance in clinical tasks is difficult since the probability density functions of the d...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2008.2008967

    authors: Park S,Witten JM,Myers KJ

    更新日期:2009-05-01 00:00:00

  • Space-time segmentation using level set active contours applied to myocardial gated SPECT.

    abstract::This paper presents a new variational method for the segmentation of a moving object against a still background, over a sequence of [two-dimensional or three-dimensional (3-D)] image frames. The method is illustrated in application to myocardial gated single photon emission computed tomography (SPECT) data, and incorp...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.932748

    authors: Debreuve E,Barlaud M,Aubert G,Laurette I,Darcourt J

    更新日期:2001-07-01 00:00:00

  • Anatomy and flow in normal and ischemic microvasculature based on a novel temporal fractal dimension analysis algorithm using contrast enhanced ultrasound.

    abstract::Strategies for improvement of blood flow by promoting new vessel growth in ischemic tissue are being developed. Recently, contrast-enhanced ultrasound (CEU) imaging has been used to assess tissue perfusion in models of ischemia-related angiogenesis, growth-factor mediated angiogenesis, and tumor angiogenesis. In these...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/tmi.2006.877442

    authors: Charalampidis D,Pascotto M,Kerut EK,Lindner JR

    更新日期:2006-08-01 00:00:00

  • A "twisting and bending" model-based nonrigid image registration technique for 3-D ultrasound carotid images.

    abstract::Atherosclerosis at the carotid bifurcation resulting in cerebral emboli is a major cause of ischemic stroke. Most strokes associated with carotid atherosclerosis can be prevented by lifestyle/dietary changes and pharmacological treatments if identified early by monitoring carotid plaque changes. Registration of 3-D ul...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2008.918326

    authors: Nanayakkara ND,Chiu B,Samani A,Spence JD,Samarabandu J,Fenster A

    更新日期:2008-10-01 00:00:00

  • Sensitivity Enhancement in Magnetic Particle Imaging by Background Subtraction.

    abstract::Biomedical applications such as cell tracking and angiography require the detection of low concentrations of superparamagnetic iron oxide nanoparticles (SPIOs) for imaging purposes. Magnetic particle imaging (MPI) is a new technology which enables the quantitative and time-resolved localization of SPIO distributions. ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2015.2501462

    authors: Them K,Kaul MG,Jung C,Hofmann M,Mummert T,Werner F,Knopp T

    更新日期:2016-03-01 00:00:00

  • Simultaneous sparsity model for histopathological image representation and classification.

    abstract::The multi-channel nature of digital histopathological images presents an opportunity to exploit the correlated color channel information for better image modeling. Inspired by recent work in sparsity for single channel image classification, we propose a new simultaneous sparsity model for multi-channel histopathologic...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2014.2306173

    authors: Srinivas U,Mousavi HS,Monga V,Hattel A,Jayarao B