Exact frequency-domain reconstruction for thermoacoustic tomography--II: Cylindrical geometry.

Abstract:

:Microwave-induced thermoacoustic tomography (TAT) in a cylindrical configuration is developed to image biological tissue. Thermoacoustic signals are acquired by scanning a flat ultrasonic transducer. Using a new expansion of a spherical wave in cylindrical coordinates, we apply the Fourier and Hankel transforms to TAT and obtain an exact frequency-domain reconstruction method. The effect of discrete spatial sampling on image quality is analyzed. An aliasing-proof reconstruction method is proposed. Numerical and experimental results are included.

journal_name

IEEE Trans Med Imaging

authors

Xu Y,Xu M,Wang LV

doi

10.1109/TMI.2002.801171

subject

Has Abstract

pub_date

2002-07-01 00:00:00

pages

829-33

issue

7

eissn

0278-0062

issn

1558-254X

journal_volume

21

pub_type

杂志文章
  • Imaging the distribution of magnetic nanoparticles with ultrasound.

    abstract::Magnetic nanoparticles can be caused to oscillate under the influence of an incident ultrasonic wave. If the particles are momentarily aligned with a magnetizing pulse creating a macroscopic magnetization, this oscillation will result in a time-varying magnetic moment which should be detectable as an induced voltage i...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2007.895476

    authors: Norton SJ,Vo-Dinh T

    更新日期:2007-05-01 00:00:00

  • Three-dimensional microwave breast imaging: dispersive dielectric properties estimation using patient-specific basis functions.

    abstract::Breast imaging via microwave tomography involves estimating the distribution of dielectric properties within the patient's breast on a discrete mesh. The number of unknowns in the discrete mesh can be very large for 3-D imaging, and this results in computational challenges. We propose a new approach where the discrete...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2008.2008959

    authors: Winters DW,Shea JD,Kosmas P,Van Veen BD,Hagness SC

    更新日期:2009-07-01 00:00:00

  • Model-based MR parameter mapping with sparsity constraints: parameter estimation and performance bounds.

    abstract::Magnetic resonance parameter mapping (e.g., T1 mapping, T2 mapping, T*2 mapping) is a valuable tool for tissue characterization. However, its practical utility has been limited due to long data acquisition time. This paper addresses this problem with a new model-based parameter mapping method. The proposed method util...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2014.2322815

    authors: Zhao B,Lam F,Liang ZP

    更新日期:2014-09-01 00:00:00

  • A rapid look-up table method for reconstructing MR images from arbitrary K-space trajectories.

    abstract::Look-up tables (LUTs) are a common method for increasing the speed of many algorithms. Their use can be extended to the reconstruction of nonuniformly sampled k-space data using either a discrete Fourier transform (DFT) algorithm or a convolution-based gridding algorithm. A table for the DFT would be precalculated arr...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.918471

    authors: Dale B,Wendt M,Duerk JL

    更新日期:2001-03-01 00:00:00

  • Fast catheter segmentation from echocardiographic sequences based on segmentation from corresponding X-ray fluoroscopy for cardiac catheterization interventions.

    abstract::Echocardiography is a potential alternative to X-ray fluoroscopy in cardiac catheterization given its richness in soft tissue information and its lack of ionizing radiation. However, its small field of view and acoustic artifacts make direct automatic segmentation of the catheters very challenging. In this study, a fa...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2014.2360988

    authors: Wu X,Housden J,Ma Y,Razavi B,Rhode K,Rueckert D

    更新日期:2015-04-01 00:00:00

  • A versatile wavelet domain noise filtration technique for medical imaging.

    abstract::In this paper, we propose a robust wavelet domain method for noise filtering in medical images. The proposed method adapts itself to various types of image noise as well as to the preference of the medical expert; a single parameter can be used to balance the preservation of (expert-dependent) relevant details against...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2003.809588

    authors: Pizurica A,Philips W,Lemahieu I,Acheroy M

    更新日期:2003-03-01 00:00:00

  • Multi-channel microstrip transceiver arrays using harmonics for high field MR imaging in humans.

    abstract::Radio-frequency (RF) transceiver array design using primary and higher order harmonics for in vivo parallel magnetic resonance imaging imaging (MRI) and spectroscopic imaging is proposed. The improved electromagnetic decoupling performance, unique magnetic field distributions and high-frequency operation capabilities ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2011.2166273

    authors: Wu B,Wang C,Lu J,Pang Y,Nelson SJ,Vigneron DB,Zhang X

    更新日期:2012-02-01 00:00:00

  • Diffuse optical tomography enhanced by clustered sparsity for functional brain imaging.

    abstract::Diffuse optical tomography (DOT) is a noninvasive technique which measures hemodynamic changes in the tissue with near infrared light, which has been increasingly used to study brain functions. Due to the nature of light propagation in the tissue, the reconstruction problem is severely ill-posed. For linearized DOT pr...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2014.2338214

    authors: Chen C,Tian F,Liu H,Huang J

    更新日期:2014-12-01 00:00:00

  • Axial resolution and the value of interpolating scan in multislice positron computed tomography.

    abstract::We have calculated the aperture function of a positron computed tomograph (PCT) with computer simulation, and evaluated the axial resolution of a multislice PCT, Positologica III, both theoretically and experimentally. The axial point spread function (PSF) was approximately a triangle at or near the center of the fiel...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.1985.4307692

    authors: Senda M,Yonekura Y,Tamaki N,Tanaka Y,Komori M,Minato K,Konishi J,Torizuka K

    更新日期:1985-01-01 00:00:00

  • Comments on "A new algorithm for border description of polarized light surface microscopic images of pigmented skin lesions".

    abstract::In this paper, discrepancies and reference inaccuracies in the paper (Grana et al., 2003) are pointed out. Specifically, it is demonstrated that the definitions of "lesion gradient" and "skin lesion gradient," widely used in a number of medical papers on computer analysis of pigmented skin lesions, are unambiguous, an...

    journal_title:IEEE transactions on medical imaging

    pub_type: 评论,信件

    doi:10.1109/tmi.2006.884205

    authors: Burroni M,Alparone L,Argenti F

    更新日期:2006-12-01 00:00:00

  • Shielded microstrip array for 7T human MR imaging.

    abstract::The high-frequency transceiver array based on the microstrip transmission line design is a promising technique for ultrahigh field magnetic resonance imaging (MRI) signal excitation and reception. However, with the increase of radio-frequency (RF) channels, the size of the ground plane in each microstrip coil element ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2009.2033597

    authors: Wu B,Wang C,Kelley DA,Xu D,Vigneron DB,Nelson SJ,Zhang X

    更新日期:2010-01-01 00:00:00

  • Automatic recovery of the optic nervehead geometry in optical coherence tomography.

    abstract::Optical coherence tomography (OCT) uses retroreflected light to provide micrometer-resolution, cross-sectional scans of biological tissues. OCT's first application was in ophthalmic imaging where it has proven particularly useful in diagnosing, monitoring, and studying glaucoma. Diagnosing glaucoma is difficult and it...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2006.871417

    authors: Boyer KL,Herzog A,Roberts C

    更新日期:2006-05-01 00:00:00

  • A filtered backprojection algorithm for triple-source helical cone-beam CT.

    abstract::Multisource cone-beam computed tomography (CT) is an attractive approach of choice for superior temporal resolution, which is critically important for cardiac imaging and contrast enhanced studies. In this paper, we present a filtered-backprojection (FBP) algorithm for triple-source helical cone-beam CT. The algorithm...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2008.2004817

    authors: Zhao J,Jin Y,Lu Y,Wang G

    更新日期:2009-03-01 00:00:00

  • In situ characterization of the degradation of PLGA microspheres in hyaluronic acid hydrogels by optical coherence tomography.

    abstract::The polymeric implant material poly(lactide-co-glycolide) (PLGA) degrades by a process of bulk degradation, which allows it to be used for the controlled release of therapeutic molecules from implants and microspheres. The temporal characterization of PLGA microsphere degradation has been limited by the need to destru...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2008.927356

    authors: Patterson J,Stayton PS,Li X

    更新日期:2009-01-01 00:00:00

  • Spatio-temporal fMRI analysis using Markov random fields.

    abstract::Functional magnetic resonance images (fMRI's) provide high-resolution datasets which allow researchers to obtain accurate delineation and sensitive detection of activation areas involved in cognitive processes. To preserve the resolution of this noninvasive technique, refined methods are required in the analysis of th...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.746636

    authors: Descombes X,Kruggel F,von Cramon DY

    更新日期:1998-12-01 00:00:00

  • Graph-based multi-surface segmentation of OCT data using trained hard and soft constraints.

    abstract::Optical coherence tomography (OCT) is a well-established image modality in ophthalmology and used daily in the clinic. Automatic evaluation of such datasets requires an accurate segmentation of the retinal cell layers. However, due to the naturally low signal to noise ratio and the resulting bad image quality, this ta...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2012.2225152

    authors: Dufour PA,Ceklic L,Abdillahi H,Schröder S,De Dzanet S,Wolf-Schnurrbusch U,Kowal J

    更新日期:2013-03-01 00:00:00

  • Parameterization-invariant shape comparisons of anatomical surfaces.

    abstract::We consider 3-D brain structures as continuous parameterized surfaces and present a metric for their comparisons that is invariant to the way they are parameterized. Past comparisons of such surfaces involve either volume deformations or nonrigid matching under fixed parameterizations of surfaces. We propose a new mat...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2010.2099130

    authors: Kurtek S,Klassen E,Ding Z,Jacobson SW,Jacobson JL,Avison MJ,Srivastava A

    更新日期:2011-03-01 00:00:00

  • Lung and Pancreatic Tumor Characterization in the Deep Learning Era: Novel Supervised and Unsupervised Learning Approaches.

    abstract::Risk stratification (characterization) of tumors from radiology images can be more accurate and faster with computer-aided diagnosis (CAD) tools. Tumor characterization through such tools can also enable non-invasive cancer staging, prognosis, and foster personalized treatment planning as a part of precision medicine....

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2019.2894349

    authors: Hussein S,Kandel P,Bolan CW,Wallace MB,Bagci U

    更新日期:2019-08-01 00:00:00

  • Difference-Frequency Ultrasound Imaging With Non-Linear Contrast.

    abstract::Conventional ultrasound imaging is based on the scattering of sound from inhomogeneities in the density and the speed of sound and is often used in medicine to resolve pathologic compared to normal tissue. Here we demonstrate a difference-frequency ultrasound (dfUS) imaging method that is based on the interaction of t...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2019.2957280

    authors: Li Y,Polyak D,Johnson E,Yecies D,Shevidi S,de la Zerda A,Gephart MH,Chu S

    更新日期:2020-05-01 00:00:00

  • A direct reconstruction algorithm for electrical impedance tomography.

    abstract::A direct (noniterative) reconstruction algorithm for electrical impedance tomography in the two-dimensional (2-D), cross-sectional geometry is reviewed. New results of a reconstruction of a numerically simulated phantom chest are presented. The algorithm is based on the mathematical uniqueness proof by A. I. Nachman [...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2002.800574

    authors: Mueller JL,Siltanen S,Isaacson D

    更新日期:2002-06-01 00:00:00

  • Segmentation of prostate boundaries from ultrasound images using statistical shape model.

    abstract::This paper presents a statistical shape model for the automatic prostate segmentation in transrectal ultrasound images. A Gabor filter bank is first used to characterize the prostate boundaries in ultrasound images in both multiple scales and multiple orientations. The Gabor features are further reconstructed to be in...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2003.809057

    authors: Shen D,Zhan Y,Davatzikos C

    更新日期:2003-04-01 00:00:00

  • Border detection on digitized skin tumor images.

    abstract::A radial search technique is presented for detecting skin tumor borders in clinical dermatology images. First, it includes two rounds of radial search based on the same tumor center. The first-round search is independent, and the second-round search is knowledge-based tracking. Then a rescan with a new center is used ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.896789

    authors: Zhang Z,Stoecker WV,Moss RH

    更新日期:2000-11-01 00:00:00

  • Ovarian ultrasound image analysis: follicle segmentation.

    abstract::Ovarian ultrasound is an effective tool in infertility treatment. Repeated measurements of the size and shape of follicles over several days are the primary means of evaluation by physicians. Currently, follicle wall segmentation is achieved by manual tracing which is time consuming and susceptible to inter-operator v...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.746626

    authors: Krivanek A,Sonka M

    更新日期:1998-12-01 00:00:00

  • Automatic "pipeline" analysis of 3-D MRI data for clinical trials: application to multiple sclerosis.

    abstract::The quantitative analysis of magnetic resonance imaging (MRI) data has become increasingly important in both research and clinical studies aiming at human brain development, function, and pathology. Inevitably, the role of quantitative image analysis in the evaluation of drug therapy will increase, driven in part by r...

    journal_title:IEEE transactions on medical imaging

    pub_type: 临床试验,杂志文章

    doi:10.1109/TMI.2002.806283

    authors: Zijdenbos AP,Forghani R,Evans AC

    更新日期:2002-10-01 00:00:00

  • Ultrasound imaging and identification of microcalcification clusters by correlation of scatter from multiple angles.

    abstract::Various types of malignant and benign breast tumors are associated with clusters of calcifications with grain sizes 0.1 to a few mm spread out over volumes of a few cc. A series of phantoms containing calcium carbonate grains embedded in a gelatin mixture were made and the ultrasound scattering patterns were measured ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.1984.4307668

    authors: Perez-Mendez V,Wiedenbeck P,Davis P,Tzeng CJ

    更新日期:1984-01-01 00:00:00

  • Image reconstruction in magnetic resonance conductivity tensor imaging (MRCTI).

    abstract::Almost all magnetic resonance electrical impedance tomography (MREIT) reconstruction algorithms proposed to date assume isotropic conductivity in order to simplify the image reconstruction. However, it is well known that most of biological tissues have anisotropic conductivity values. In this study, four novel anisotr...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2011.2171192

    authors: Değirmenci E,Eyüboğlu BM

    更新日期:2012-03-01 00:00:00

  • Computation of the mid-sagittal plane in 3-D brain images.

    abstract::We present a new method to automatically compute, reorient, and recenter the mid-sagittal plane in anatomical and functional three-dimensional (3-D) brain images. This iterative approach is composed of two steps. At first, given an initial guess of the mid-sagittal plane (generally, the central plane of the image grid...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.993131

    authors: Prima S,Ourselin S,Ayache N

    更新日期:2002-02-01 00:00:00

  • Effect of detector weighting functions on the point spread function of high-resolution PET tomographs: a simulation study.

    abstract::The point spread function (PSF) of a ring PET tomograph is known to be spatially variant and difficult to obtain because it must be reconstructed from projections. A mathematical model was developed to simulate the data acquisition from a point source and to reconstruct the PSF, taking into account weighting functions...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.158942

    authors: Karuta B,Lecomte R

    更新日期:1992-01-01 00:00:00

  • Multi-material decomposition using statistical image reconstruction for spectral CT.

    abstract::Spectral computed tomography (CT) provides information on material characterization and quantification because of its ability to separate different basis materials. Dual-energy (DE) CT provides two sets of measurements at two different source energies. In principle, two materials can be accurately decomposed from DECT...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2014.2320284

    authors: Long Y,Fessler JA

    更新日期:2014-08-01 00:00:00

  • Self-Supervised Ultrasound to MRI Fetal Brain Image Synthesis.

    abstract::Fetal brain magnetic resonance imaging (MRI) offers exquisite images of the developing brain but is not suitable for second-trimester anomaly screening, for which ultrasound (US) is employed. Although expert sonographers are adept at reading US images, MR images which closely resemble anatomical images are much easier...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2020.3018560

    authors: Jiao J,Namburete AIL,Papageorghiou AT,Noble JA

    更新日期:2020-12-01 00:00:00