Difference-Frequency Ultrasound Imaging With Non-Linear Contrast.

Abstract:

:Conventional ultrasound imaging is based on the scattering of sound from inhomogeneities in the density and the speed of sound and is often used in medicine to resolve pathologic compared to normal tissue. Here we demonstrate a difference-frequency ultrasound (dfUS) imaging method that is based on the interaction of two sound pulses that propagate non-collinearly and intersect in space and time. The dfUS signal arises primarily from the second-order non-linear coefficient, a contrast mechanism that differs from linear and harmonic US imaging. The distinct contrast mechanism allows dfUS to image anatomic features that are not identifiable in conventional US images of salmon and pig kidney tissue. Further, dfUS produces enhanced contrast of glioblastoma tumor implanted in the mouse brain, revealing its potential for improving medical diagnosis. Progress towards a real-time system is discussed.

journal_name

IEEE Trans Med Imaging

authors

Li Y,Polyak D,Johnson E,Yecies D,Shevidi S,de la Zerda A,Gephart MH,Chu S

doi

10.1109/TMI.2019.2957280

subject

Has Abstract

pub_date

2020-05-01 00:00:00

pages

1759-1766

issue

5

eissn

0278-0062

issn

1558-254X

journal_volume

39

pub_type

杂志文章
  • A hardware architecture using finite-field arithmetic for computing maximum-likelihood estimates in emission tomography.

    abstract::A special-purpose hardware architecture is proposed to implement the expectation-maximization algorithm to compute, in clinically useful times, the maximum-likelihood estimate of a radionuclide distribution for a positron-emission tomogram from time-of-flight measurements. Two-dimensional convolutions required for for...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.14510

    authors: Klotz HR,Snyder DL

    更新日期:1988-01-01 00:00:00

  • Investigation of Axial and Angular Sampling in Multi-Detector Pinhole-SPECT Brain Imaging.

    abstract::We designed a dedicated multi-detector multi-pinhole brain SPECT scanner to generate images of higher quality compared to general-purpose systems. The system, AdaptiSPECT-C, is intended to adapt its sensitivity-resolution trade-off by varying its aperture configurations allowing both high-sensitivity dynamic and high-...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2020.3015079

    authors: Zeraatkar N,Kalluri KS,Auer B,Konik A,Fromme TJ,Furenlid LR,Kuo PH,King MA

    更新日期:2020-12-01 00:00:00

  • Optimal rebinning of time-of-flight PET data.

    abstract::Time-of-flight (TOF) positron emission tomography (PET) scanners offer the potential for significantly improved signal-to-noise ratio (SNR) and lesion detectability in clinical PET. However, fully 3D TOF PET image reconstruction is a challenging task due to the huge data size. One solution to this problem is to rebin ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2011.2149537

    authors: Ahn S,Cho S,Li Q,Lin Y,Leahy RM

    更新日期:2011-10-01 00:00:00

  • General reconstruction theory for multislice X-ray computed tomography with a gantry tilt.

    abstract::This paper discusses image reconstruction with a tilted gantry in multislice computed tomography (CT) with helical (spiral) data acquisition. The reconstruction problem with gantry tilt is shown to be transformable into the problem of reconstructing a virtual object from multislice CT data with no gantry tilt, for whi...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2004.829337

    authors: Noo F,Defrise M,Kudo H

    更新日期:2004-09-01 00:00:00

  • Estimation of the hemodynamic response in event-related functional MRI: Bayesian networks as a framework for efficient Bayesian modeling and inference.

    abstract::A convenient way to analyze blood-oxygen-level-dependent functional magnetic resonance imaging data consists of modeling the whole brain as a stationary, linear system characterized by its transfer function: the hemodynamic response function (HRF). HRF estimation, though of the greatest interest, is still under invest...

    journal_title:IEEE transactions on medical imaging

    pub_type: 临床试验,杂志文章

    doi:10.1109/TMI.2004.831221

    authors: Marrelec G,Ciuciu P,Pélégrini-Issac M,Benali H

    更新日期:2004-08-01 00:00:00

  • Automated characterization of breast lesions imaged with an ultrafast DCE-MR protocol.

    abstract::Dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) of the breast has become an invaluable tool in the clinical work-up of patients suspected of having breast carcinoma. The purpose of this study is to introduce novel features extracted from the kinetics of contrast agent uptake imaged by a short (100 s) vi...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2013.2281984

    authors: Platel B,Mus R,Welte T,Karssemeijer N,Mann R

    更新日期:2014-02-01 00:00:00

  • A method for modeling noise in medical images.

    abstract::We have developed a method to study the statistical properties of the noise found in various medical images. The method is specifically designed for types of noise with uncorrelated fluctuations. Such signal fluctuations generally originate in the physical processes of imaging rather than in the tissue textures. Vario...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2004.832656

    authors: Gravel P,Beaudoin G,De Guise JA

    更新日期:2004-10-01 00:00:00

  • Time delay for arrival of MR contrast agent in collateral-dependent myocardium.

    abstract::An analysis of the kinetics of myocardial contrast enhancement is an important component of myocardial perfusion studies. The contrast enhancement can be modeled by a linear time-invariant system, and the myocardial impulse response, calculated by deconvolution of the measured tissue response with an arterial input, g...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2004.827969

    authors: Jerosch-Herold M,Hu X,Murthy NS,Seethamraju RT

    更新日期:2004-07-01 00:00:00

  • Fast joint reconstruction of dynamic R2* and field maps in functional MRI.

    abstract::Blood oxygen level dependent (BOLD) functional magnetic resonance imaging (fMRI) is conventionally done by reconstructing T(2)(*)-weighted images. However, since the images are unitless they are nonquantifiable in terms of important physiological parameters. An alternative approach is to reconstruct R(2)(*) maps which...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2008.917247

    authors: Olafsson VT,Noll DC,Fessler JA

    更新日期:2008-09-01 00:00:00

  • Lesion detection in dynamic FDG-PET using matched subspace detection.

    abstract::We describe a matched subspace detection algorithm to assist in the detection of small tumors in dynamic positron emission tomography (PET) images. The algorithm is designed to differentiate tumors from background using the time activity curves (TACs) that characterize the uptake of PET tracers. TACs are modeled using...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2008.929105

    authors: Li Z,Li Q,Yu X,Conti PS,Leahy RM

    更新日期:2009-02-01 00:00:00

  • Free-breathing diffusion tensor imaging and tractography of the human heart in healthy volunteers using wavelet-based image fusion.

    abstract::Free-breathing cardiac diffusion tensor imaging (DTI) is a promising but challenging technique for the study of fiber structures of the human heart in vivo. This work proposes a clinically compatible and robust technique to provide three-dimensional (3-D) fiber architecture properties of the human heart. To this end, ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2014.2356792

    authors: Wei H,Viallon M,Delattre BM,Moulin K,Yang F,Croisille P,Zhu Y

    更新日期:2015-01-01 00:00:00

  • Attention to Lesion: Lesion-Aware Convolutional Neural Network for Retinal Optical Coherence Tomography Image Classification.

    abstract::Automatic and accurate classification of retinal optical coherence tomography (OCT) images is essential to assist ophthalmologist in the diagnosis and grading of macular diseases. Clinically, ophthalmologists usually diagnose macular diseases according to the structures of macular lesions, whose morphologies, size, an...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2019.2898414

    authors: Fang L,Wang C,Li S,Rabbani H,Chen X,Liu Z

    更新日期:2019-08-01 00:00:00

  • Parameter relations for the Shinnar-Le Roux selective excitation pulse design algorithm [NMR imaging].

    abstract::An overview of the Shinnar-Le Roux (SLR) algorithm is presented. It is shown how the performance of SLR pulses can be very accurately specified analytically. This reveals how to design a pulse that produces a specified slice profile and allows the pulse designer to trade off analytically the parameters describing the ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.75611

    authors: Pauly J,Le Roux P,Nishimura D,Macovski A

    更新日期:1991-01-01 00:00:00

  • Joint Design of Excitation k-Space Trajectory and RF Pulse for Small-Tip 3D Tailored Excitation in MRI.

    abstract::We propose a new method for the joint design of k-space trajectory and RF pulse in 3D small-tip tailored excitation. Designing time-varying RF and gradient waveforms for a desired 3D target excitation pattern in MRI poses a non-linear, non-convex, constrained optimization problem with relatively large problem size tha...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2015.2478880

    authors: Hao S,Fessler JA,Noll DC,Nielsen JF

    更新日期:2016-02-01 00:00:00

  • Learning-based deformable registration of MR brain images.

    abstract::This paper presents a learning-based method for deformable registration of magnetic resonance (MR) brain images. There are two novelties in the proposed registration method. First, a set of best-scale geometric features are selected for each point in the brain, in order to facilitate correspondence detection during th...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/tmi.2006.879320

    authors: Wu G,Qi F,Shen D

    更新日期:2006-09-01 00:00:00

  • The elliptical cone of uncertainty and its normalized measures in diffusion tensor imaging.

    abstract::Diffusion tensor magnetic resonance imaging (DT-MRI) is capable of providing quantitative insights into tissue microstructure in the brain. An important piece of information offered by DT-MRI is the directional preference of diffusing water molecules within a voxel. Building upon this local directional information, DT...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2008.915663

    authors: Koay CG,Nevo U,Chang LC,Pierpaoli C,Basser PJ

    更新日期:2008-06-01 00:00:00

  • Unwarping of unidirectionally distorted EPI images.

    abstract::Echo-planar imaging (EPI) is a fast nuclear magnetic resonance imaging (MRI) method. Unfortunately, local magnetic field inhomogeneities induced mainly by the subject's presence cause significant geometrical distortion, predominantly along the phase-encoding direction, which must be undone to allow for meaningful furt...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.836368

    authors: Kybic J,Thévenaz P,Nirkko A,Unser M

    更新日期:2000-02-01 00:00:00

  • Intensity-based image registration using robust correlation coefficients.

    abstract::The ordinary sample correlation coefficient is a popular similarity measure for aligning images from the same or similar modalities. However, this measure can be sensitive to the presence of "outlier" objects that appear in one image but not the other, such as surgical instruments, the patient table, etc., which can l...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2004.835313

    authors: Kim J,Fessler JA

    更新日期:2004-11-01 00:00:00

  • Multifrequency electrical impedance tomography using spectral constraints.

    abstract::Multifrequency electrical impedance tomography (MFEIT) exploits the dependence of tissue impedance on frequency to recover an image of conductivity. MFEIT could provide emergency diagnosis of pathologies such as acute stroke, brain injury and breast cancer. We present a method for performing MFEIT using spectral const...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2013.2284966

    authors: Malone E,Sato Dos Santos G,Holder D,Arridge S

    更新日期:2014-02-01 00:00:00

  • Optoacoustic Dermoscopy of the Human Skin: Tuning Excitation Energy for Optimal Detection Bandwidth With Fast and Deep Imaging in vivo.

    abstract::Optoacoustic (photoacoustic) dermoscopy offers two principal advantages over conventional optical imaging applied in dermatology. First, it yields high-resolution cross-sectional images of the skin at depths not accessible to other non-invasive optical imaging methods. Second, by resolving absorption spectra at multip...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2017.2664142

    authors: Schwarz M,Soliman D,Omar M,Buehler A,Ovsepian SV,Aguirre J,Ntziachristos V

    更新日期:2017-06-01 00:00:00

  • Improved SPECT quantitation using fully three-dimensional iterative spatially variant scatter response compensation.

    abstract::The quality and quantitative accuracy of iteratively reconstructed SPECT images improves when better point spread function (PSF) models of the gamma camera are used during reconstruction. Here, inclusion in the PSF model of photon crosstalk between different slices caused by limited gamma camera resolution and scatter...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.511752

    authors: Beekman FJ,Kamphuis C,Viergever MA

    更新日期:1996-01-01 00:00:00

  • Local phase tensor features for 3-D ultrasound to statistical shape+pose spine model registration.

    abstract::Most conventional spine interventions are performed under X-ray fluoroscopy guidance. In recent years, there has been a growing interest to develop nonionizing imaging alternatives to guide these procedures. Ultrasound guidance has emerged as a leading alternative. However, a challenging problem is automatic identific...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2014.2332571

    authors: Hacihaliloglu I,Rasoulian A,Rohling RN,Abolmaesumi P

    更新日期:2014-11-01 00:00:00

  • Practical considerations for 3-D image reconstruction using spherically symmetric volume elements.

    abstract::Spherically symmetric volume elements with smooth tapering of the values near their boundaries are alternatives to the more conventional voxels for the construction of volume images in the computer. Their use, instead of voxels, introduces additional parameters which enable the user to control the shape of the volume ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.481442

    authors: Matej S,Lewitt RM

    更新日期:1996-01-01 00:00:00

  • Automatic Cataract Classification Using Deep Neural Network With Discrete State Transition.

    abstract::Cataract is the clouding of lens, which affects vision and it is the leading cause of blindness in the world's population. Accurate and convenient cataract detection and cataract severity evaluation will improve the situation. Automatic cataract detection and grading methods are proposed in this paper. With prior know...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2019.2928229

    authors: Zhou Y,Li G,Li H

    更新日期:2020-02-01 00:00:00

  • Co-registration of white matter tractographies by adaptive-mean-shift and Gaussian mixture modeling.

    abstract::In this paper, we present a robust approach to the registration of white matter tractographies extracted from diffusion tensor-magnetic resonance imaging scans. The fibers are projected into a high dimensional feature space based on the sequence of their 3-D coordinates. Adaptive mean-shift clustering is applied to ex...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2009.2029097

    authors: Zvitia O,Mayer A,Shadmi R,Miron S,Greenspan HK

    更新日期:2010-01-01 00:00:00

  • NMR velocity-selective excitation composites for flow and motion imaging and suppression of static tissue signal.

    abstract::We propose a technique aimed at increasing the sensitivity of magnetic resonance imaging (MRI) measurements to the signal from moving material. The technique is formulated within the framework of a velocity phase-encoding strategy. The salient new feature of the protocol is the application of an excitation pulse, foll...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.1987.4307814

    authors: Moran PR,Saloner D,Tsui BW

    更新日期:1987-01-01 00:00:00

  • Combined volumetric and surface registration.

    abstract::In this paper, we propose a novel method for the registration of volumetric images of the brain that optimizes the alignment of both cortical and subcortical structures. In order to achieve this, relevant geometrical information is extracted from a surface-based morph and diffused into the volume using the Navier oper...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2008.2004426

    authors: Postelnicu G,Zollei L,Fischl B

    更新日期:2009-04-01 00:00:00

  • Estimating CT Image From MRI Data Using Structured Random Forest and Auto-Context Model.

    abstract::Computed tomography (CT) imaging is an essential tool in various clinical diagnoses and radiotherapy treatment planning. Since CT image intensities are directly related to positron emission tomography (PET) attenuation coefficients, they are indispensable for attenuation correction (AC) of the PET images. However, due...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2015.2461533

    authors: Huynh T,Gao Y,Kang J,Wang L,Zhang P,Lian J,Shen D,Alzheimer's Disease Neuroimaging Initiative.

    更新日期:2016-01-01 00:00:00

  • An Inverse Problems Approach to MR-EPT Image Reconstruction.

    abstract::Magnetic Resonance-Electrical Properties Tomography (MR-EPT) is an imaging modality that maps the spatial distribution of the electrical conductivity and permittivity using standard MRI systems. The presence of a body within the scanner alters the RF field, and by mapping these alterations it is possible to recover th...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2015.2466082

    authors: Borsic A,Perreard I,Mahara A,Halter RJ

    更新日期:2016-01-01 00:00:00

  • PET image reconstruction using information theoretic anatomical priors.

    abstract::We describe a nonparametric framework for incorporating information from co-registered anatomical images into positron emission tomographic (PET) image reconstruction through priors based on information theoretic similarity measures. We compare and evaluate the use of mutual information (MI) and joint entropy (JE) bet...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2010.2076827

    authors: Somayajula S,Panagiotou C,Rangarajan A,Li Q,Arridge SR,Leahy RM

    更新日期:2011-03-01 00:00:00