The elliptical cone of uncertainty and its normalized measures in diffusion tensor imaging.

Abstract:

:Diffusion tensor magnetic resonance imaging (DT-MRI) is capable of providing quantitative insights into tissue microstructure in the brain. An important piece of information offered by DT-MRI is the directional preference of diffusing water molecules within a voxel. Building upon this local directional information, DT-MRI tractography attempts to construct global connectivity of white matter tracts. The interplay between local directional information and global structural information is crucial in understanding changes in tissue microstructure as well as in white matter tracts. To this end, the right circular cone of uncertainty was proposed by Basser as a local measure of tract dispersion. Recent experimental observations by Jeong et al. and Lazar et al. that the cones of uncertainty in the brain are mostly elliptical motivate the present study to investigate analytical approaches to quantify their findings. Two analytical approaches for constructing the elliptical cone of uncertainty, based on the first-order matrix perturbation and the error propagation method via diffusion tensor representations, are presented and their theoretical equivalence is established. We propose two normalized measures, circumferential and areal, to quantify the uncertainty of the major eigenvector of the diffusion tensor. We also describe a new technique of visualizing the cone of uncertainty in 3-D.

journal_name

IEEE Trans Med Imaging

authors

Koay CG,Nevo U,Chang LC,Pierpaoli C,Basser PJ

doi

10.1109/TMI.2008.915663

subject

Has Abstract

pub_date

2008-06-01 00:00:00

pages

834-46

issue

6

eissn

0278-0062

issn

1558-254X

journal_volume

27

pub_type

杂志文章
  • Digital mammography: mixed feature neural network with spectral entropy decision for detection of microcalcifications.

    abstract::A computationally efficient mixed feature based neural network (MFNN) is proposed for the detection of microcalcification clusters (MCCs) in digitized mammograms. The MFNN employs features computed in both the spatial and spectral domain and uses spectral entropy as a decision parameter. Backpropagation with Kalman fi...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.538936

    authors: Zheng B,Qian W,Clarke LP

    更新日期:1996-01-01 00:00:00

  • PET Image Reconstruction Using Deep Image Prior.

    abstract::Recently, deep neural networks have been widely and successfully applied in computer vision tasks and have attracted growing interest in medical imaging. One barrier for the application of deep neural networks to medical imaging is the need for large amounts of prior training pairs, which is not always feasible in cli...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2018.2888491

    authors: Gong K,Catana C,Qi J,Li Q

    更新日期:2019-07-01 00:00:00

  • Red Lesion Detection Using Dynamic Shape Features for Diabetic Retinopathy Screening.

    abstract::The development of an automatic telemedicine system for computer-aided screening and grading of diabetic retinopathy depends on reliable detection of retinal lesions in fundus images. In this paper, a novel method for automatic detection of both microaneurysms and hemorrhages in color fundus images is described and va...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2015.2509785

    authors: Seoud L,Hurtut T,Chelbi J,Cheriet F,Langlois JM

    更新日期:2016-04-01 00:00:00

  • Three-dimensional segmentation of fluid-associated abnormalities in retinal OCT: probability constrained graph-search-graph-cut.

    abstract::An automated method is reported for segmenting 3-D fluid-associated abnormalities in the retina, so-called symptomatic exudate-associated derangements (SEAD), from 3-D OCT retinal images of subjects suffering from exudative age-related macular degeneration. In the first stage of a two-stage approach, retinal layers ar...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2012.2191302

    authors: Chen X,Niemeijer M,Zhang L,Lee K,Abramoff MD,Sonka M

    更新日期:2012-08-01 00:00:00

  • BICAV: a block-iterative parallel algorithm for sparse systems with pixel-related weighting.

    abstract::Component averaging (CAV) was recently introduced by Censor, Gordon, and Gordon as a new iterative parallel technique suitable for large and sparse unstructured systems of linear equations. Based on earlier work of Byrne and Censor, it uses diagonal weighting matrices, with pixel-related weights determined by the spar...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.959302

    authors: Censor Y,Gordon D,Gordon R

    更新日期:2001-10-01 00:00:00

  • Two iterative image restoration algorithms with applications to nuclear medicine.

    abstract::Two methods for recovering an image that has been degraded while being processed are presented. The restoration problem is formulated as a constrained optimization problem in which a measure of smoothness based on the second derivatives of the restored image is maximized subject to the constraint that noise energy is ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.126904

    authors: Charalambous C,Ghaddar FK,Kouris K

    更新日期:1992-01-01 00:00:00

  • Characterization of visually similar diffuse diseases from B-scan liver images using nonseparable wavelet transform.

    abstract::This paper describes a new approach for texture characterization, based on nonseparable wavelet decomposition, and its application for the discrimination of visually similar diffuse diseases of liver. The proposed feature-extraction algorithm applies nonseparable quincunx wavelet transform and uses energies of the tra...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.730399

    authors: Mojsilović A,Popović M,Marković S,Krstić M

    更新日期:1998-08-01 00:00:00

  • Segmentation of rodent whole-body dynamic PET images: an unsupervised method based on voxel dynamics.

    abstract::Positron emission tomography (PET) is a useful tool for pharmacokinetics studies in rodents during the preclinical phase of drug and tracer development. However, rodent organs are small as compared to the scanner's intrinsic resolution and are affected by physiological movements. We present a new method for the segmen...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2007.905106

    authors: Maroy R,Boisgard R,Comtat C,Frouin V,Cathier P,Duchesnay E,Dollé F,Nielsen PE,Trébossen R,Tavitian B

    更新日期:2008-03-01 00:00:00

  • Endoscopic video manifolds for targeted optical biopsy.

    abstract::Gastro-intestinal (GI) endoscopy is a widely used clinical procedure for screening and surveillance of digestive tract diseases ranging from Barrett's Oesophagus to oesophageal cancer. Current surveillance protocol consists of periodic endoscopic examinations performed in 3-4 month intervals including expert's visual ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2011.2174252

    authors: Atasoy S,Mateus D,Meining A,Yang GZ,Navab N

    更新日期:2012-03-01 00:00:00

  • Analysis of the role of lead resistivity in specific absorption rate for deep brain stimulator leads at 3T MRI.

    abstract::Magnetic resonance imaging (MRI) on patients with implanted deep brain stimulators (DBSs) can be hazardous because of the antenna-effect of leads exposed to the incident radio-frequency field. This study evaluated electromagnetic field and specific absorption rate (SAR) changes as a function of lead resistivity on an ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2010.2040624

    authors: Angelone LM,Ahveninen J,Belliveau JW,Bonmassar G

    更新日期:2010-04-01 00:00:00

  • Twenty new digital brain phantoms for creation of validation image data bases.

    abstract::Simulations provide a way of generating data where ground truth is known, enabling quantitative testing of image processing methods. In this paper, we present the construction of 20 realistic digital brain phantoms that can be used to simulate medical imaging data. The phantoms are made from 20 normal adults to take i...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2006.883453

    authors: Aubert-Broche B,Griffin M,Pike GB,Evans AC,Collins DL

    更新日期:2006-11-01 00:00:00

  • Deep Learning for Fast and Spatially Constrained Tissue Quantification From Highly Accelerated Data in Magnetic Resonance Fingerprinting.

    abstract::Magnetic resonance fingerprinting (MRF) is a quantitative imaging technique that can simultaneously measure multiple important tissue properties of human body. Although MRF has demonstrated improved scan efficiency as compared to conventional techniques, further acceleration is still desired for translation into routi...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2019.2899328

    authors: Fang Z,Chen Y,Liu M,Xiang L,Zhang Q,Wang Q,Lin W,Shen D

    更新日期:2019-10-01 00:00:00

  • A novel estimation method for physiological parameters in dynamic contrast-enhanced MRI: application of a distributed parameter model using Fourier-domain calculations.

    abstract::Dynamic contrast-enhanced magnetic resonance imaging (MRI) is a promising tool in the evaluation of tumor physiology. From rapidly acquired images and a model for contrast agent pharmacokinetics, physiological parameters are derived. One pharmacokinetic model, the tissue homogeneity model, enables estimation of both b...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2009.2016212

    authors: Garpebring A,Ostlund N,Karlsson M

    更新日期:2009-09-01 00:00:00

  • Computer-assisted scan protocol and reconstruction (CASPAR)-reduction of image noise and patient dose.

    abstract::X-ray computed tomography is a powerful medical imaging device. It allows high-resolution 3-D visualization of the human body. However, one drawback is the health risk associated with ionizing radiation. Simply downscaling the radiation intensities over the entire scan results in increased quantum noise. This paper pr...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2009.2034515

    authors: Sperl J,Beque D,Claus B,De Man B,Senzig B,Brokate M

    更新日期:2010-03-01 00:00:00

  • Iterative image reconstruction using inverse fourier rebinning for fully 3-D PET.

    abstract::We describe a fast forward and back projector pair based on inverse Fourier rebinning for use in iterative image reconstruction for fully three-dimensional (3-D) positron emission tomography (PET). The projector pair is used as part of a factored system matrix that takes into account detector-pair response by using sh...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:

    authors: Cho S,Li Q,Ahn S,Bai B,Leahy RM

    更新日期:2007-03-01 00:00:00

  • SNORE: spike noise removal and detection.

    abstract::A method for detection and removal of random spike noise in magnetic resonance (MR) raw data (k-space data) is described. This method would reduce or eliminate the corduroy-type and higher than usual level artifacts in MR images resulting from random spike noise in k-space data. The method described involves applying ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.276151

    authors: Foo TF,Grigsby NS,Mitchell JD,Slayman BE

    更新日期:1994-01-01 00:00:00

  • Self-stabilizing colonic capsule endoscopy: pilot study of acute canine models.

    abstract::Video capsule endoscopy (VCE) is a noninvasive method for examining the gastrointestinal tract which has been successful in small intestine studies. Recently, VCE has been attempted in the colon. However, the capsule often tumbles in the wider colonic lumen, resulting in missed regions. Self-stabilizing VCE is a novel...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2011.2163165

    authors: Filip D,Yadid-Pecht O,Andrews CN,Mintchev MP

    更新日期:2011-12-01 00:00:00

  • Co-registration of white matter tractographies by adaptive-mean-shift and Gaussian mixture modeling.

    abstract::In this paper, we present a robust approach to the registration of white matter tractographies extracted from diffusion tensor-magnetic resonance imaging scans. The fibers are projected into a high dimensional feature space based on the sequence of their 3-D coordinates. Adaptive mean-shift clustering is applied to ex...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2009.2029097

    authors: Zvitia O,Mayer A,Shadmi R,Miron S,Greenspan HK

    更新日期:2010-01-01 00:00:00

  • Implementation, investigation, and improvement of a novel cone-beam reconstruction method [SPECT].

    abstract::A three-dimensional reconstruction method which uses cone-beam data was implemented. Issues concerning implementation are investigated and discussed in detail. Computer simulations were used to determine the amount of image degradation occurring in each of the three steps that comprise the reconstruction method. In ad...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.141650

    authors: Smith BD,Chen J

    更新日期:1992-01-01 00:00:00

  • Automated segmentation and classification of high throughput yeast assay spots.

    abstract::Several technologies for characterizing genes and proteins from humans and other organisms use yeast growth or color development as read outs. The yeast two-hybrid assay, for example, detects protein-protein interactions by measuring the growth of yeast on a specific solid medium, or the ability of the yeast to change...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2007.900694

    authors: Jafari-Khouzani K,Soltanian-Zadeh H,Fotouhi F,Parrish JR,Finley RL Jr

    更新日期:2007-10-01 00:00:00

  • Unsupervised Myocardial Segmentation for Cardiac BOLD.

    abstract::A fully automated 2-D+time myocardial segmentation framework is proposed for cardiac magnetic resonance (CMR) blood-oxygen-level-dependent (BOLD) data sets. Ischemia detection with CINE BOLD CMR relies on spatio-temporal patterns in myocardial intensity, but these patterns also trouble supervised segmentation methods,...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2017.2726112

    authors: Oksuz I,Mukhopadhyay A,Dharmakumar R,Tsaftaris SA

    更新日期:2017-11-01 00:00:00

  • Tracking multiple particles in fluorescence time-lapse microscopy images via probabilistic data association.

    abstract::Tracking subcellular structures as well as viral structures displayed as 'particles' in fluorescence microscopy images yields quantitative information on the underlying dynamical processes. We have developed an approach for tracking multiple fluorescent particles based on probabilistic data association. The approach c...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2014.2359541

    authors: Godinez WJ,Rohr K

    更新日期:2015-02-01 00:00:00

  • Quantitative echocardiographic image texture: normal contraction-related variability.

    abstract::Myocardial tissue characterization using ultrasound is a growing area of investigation which attempts to evaluate the structure of the myocardium by analysis of ultrasound signals. Our laboratory has been exploring the use of texture analysis for the determination of myocardial tissue properties from two-dimensional e...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.1985.4307721

    authors: Collins SM,Skorton DJ,Prasad NV,Olshansky B,Bean JA

    更新日期:1985-01-01 00:00:00

  • Including anatomical and functional information in MC simulation of PET and SPECT brain studies. Brain-VISET: a voxel-based iterative method.

    abstract::Monte Carlo (MC) simulation provides a flexible and robust framework to efficiently evaluate and optimize image processing methods in emission tomography. In this work we present Brain-VISET (Voxel-based Iterative Simulation for Emission Tomography), a method that aims to simulate realistic [ (99m) Tc]-SPECT and [ (18...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2014.2326041

    authors: Marti-Fuster B,Esteban O,Thielemans K,Setoain X,Santos A,Ros D,Pavia J

    更新日期:2014-10-01 00:00:00

  • Digital processing for improvement of ultrasonic abdominal images.

    abstract::Digital processing that increases resolution by spatial deconvolution and histogram-based amplitude mapping has been used to improve ultrasonic abdominal image quality. The processing was applied to pulse-echo ultrasound data obtained from clinical imaging instrumentation modified to permit digital recording of signal...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.1983.4307617

    authors: Liu CN,Fatemi M,Waag RC

    更新日期:1983-01-01 00:00:00

  • Spatial-resolution enhancement in computed tomography.

    abstract::We propose an approach that combines an asymmetric fan-beam configuration and a new reconstruction algorithm to enhancing spatial resolution in computed tomography (CT). The asymmetric configuration can be achieved by changing the center of rotation (COR) from the conventional symmetric configuration. It does not, how...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/tmi.2004.840846

    authors: Pan X,Yu L,Kao CM

    更新日期:2005-02-01 00:00:00

  • A method for modeling noise in medical images.

    abstract::We have developed a method to study the statistical properties of the noise found in various medical images. The method is specifically designed for types of noise with uncorrelated fluctuations. Such signal fluctuations generally originate in the physical processes of imaging rather than in the tissue textures. Vario...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2004.832656

    authors: Gravel P,Beaudoin G,De Guise JA

    更新日期:2004-10-01 00:00:00

  • Electrical impedance spectroscopy of the breast: clinical imaging results in 26 subjects.

    abstract::Electrical impedance spectroscopy (EIS) is a potential, noninvasive technique to image women for breast cancer. Studies have shown characteristic frequency dispersions in the electrical conductivity and permittivity of malignant versus normal tissue. Using a multifrequency EIS system, we imaged the breasts of 26 women...

    journal_title:IEEE transactions on medical imaging

    pub_type: 临床试验,杂志文章

    doi:10.1109/tmi.2002.800606

    authors: Kerner TE,Paulsen KD,Hartov A,Soho SK,Poplack SP

    更新日期:2002-06-01 00:00:00

  • Comb-push ultrasound shear elastography (CUSE): a novel method for two-dimensional shear elasticity imaging of soft tissues.

    abstract::Fast and accurate tissue elasticity imaging is essential in studying dynamic tissue mechanical properties. Various ultrasound shear elasticity imaging techniques have been developed in the last two decades. However, to reconstruct a full field-of-view 2-D shear elasticity map, multiple data acquisitions are typically ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2012.2205586

    authors: Song P,Zhao H,Manduca A,Urban MW,Greenleaf JF,Chen S

    更新日期:2012-09-01 00:00:00

  • Repeatability of linear and nonlinear elastic modulus maps from repeat scans in the breast.

    abstract::Compression elastography allows the precise measurement of large deformations of soft tissue in vivo. From an image sequence showing tissue undergoing large deformation, an inverse problem for both the linear and nonlinear elastic moduli distributions can be solved. As part of a larger clinical study to evaluate nonli...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2020.3036032

    authors: Gendin DI,Nayak R,Wang Y,Bayat M,Fazzio RT,Oberai AA,Hall TJ,Barbone PE,Alizad A,Fatemi M

    更新日期:2020-11-05 00:00:00