Practical considerations for 3-D image reconstruction using spherically symmetric volume elements.

Abstract:

:Spherically symmetric volume elements with smooth tapering of the values near their boundaries are alternatives to the more conventional voxels for the construction of volume images in the computer. Their use, instead of voxels, introduces additional parameters which enable the user to control the shape of the volume element (blob) and consequently to control the characteristics of the images produced by iterative methods for reconstruction from projection data. For images composed of blobs, efficient algorithms have been designed for the projection and discrete back-projection operations, which are the crucial parts of iterative reconstruction methods. The authors have investigated the relationship between the values of the blob parameters and the properties of images represented by the blobs. Experiments show that using blobs in iterative reconstruction methods leads to substantial improvement in the reconstruction performance, based on visual quality and on quantitative measures, in comparison with the voxel case. The images reconstructed using appropriately chosen blobs are characterized by less image noise for both noiseless data and noisy data, without loss of image resolution.

journal_name

IEEE Trans Med Imaging

authors

Matej S,Lewitt RM

doi

10.1109/42.481442

subject

Has Abstract

pub_date

1996-01-01 00:00:00

pages

68-78

issue

1

eissn

0278-0062

issn

1558-254X

journal_volume

15

pub_type

杂志文章
  • Video-Rate Ring-Array Ultrasound and Photoacoustic Tomography.

    abstract::Ultrasonography and photoacoustic tomography provide complementary contrasts in preclinical studies, disease diagnoses, and imaging-guided interventional procedures. Here, we present a video-rate (20 Hz) dual-modality ultrasound and photoacoustic tomographic platform that has a high resolution, rich contrasts, deep pe...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2020.3017815

    authors: Zhang Y,Wang L

    更新日期:2020-12-01 00:00:00

  • MRI Meets MPI: a bimodal MPI-MRI tomograph.

    abstract::While magnetic particle imaging (MPI) constitutes a novel biomedical imaging technique for tracking superparamagnetic nanoparticles in vivo, unlike magnetic resonance imaging (MRI), it cannot provide anatomical background information. Until now these two modalities have been performed in separate scanners and image co...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2014.2327515

    authors: Vogel P,Lother S,Rückert MA,Kullmann WH,Jakob PM,Fidler F,Behr VC

    更新日期:2014-10-01 00:00:00

  • Magnetic resonance angiography.

    abstract::This paper describes several methods for magnetic resonance angiography that create projection images based solely on flowing blood. To both remove static tissue from the image and generate signals from blood, two classes of methods considered are temporal subtraction and cancelling excitation. Temporal subtraction, a...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.1986.4307763

    authors: Nishimura DG,Macovski A,Pauly JM

    更新日期:1986-01-01 00:00:00

  • Two iterative image restoration algorithms with applications to nuclear medicine.

    abstract::Two methods for recovering an image that has been degraded while being processed are presented. The restoration problem is formulated as a constrained optimization problem in which a measure of smoothness based on the second derivatives of the restored image is maximized subject to the constraint that noise energy is ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.126904

    authors: Charalambous C,Ghaddar FK,Kouris K

    更新日期:1992-01-01 00:00:00

  • A filtered backprojection algorithm for triple-source helical cone-beam CT.

    abstract::Multisource cone-beam computed tomography (CT) is an attractive approach of choice for superior temporal resolution, which is critically important for cardiac imaging and contrast enhanced studies. In this paper, we present a filtered-backprojection (FBP) algorithm for triple-source helical cone-beam CT. The algorithm...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2008.2004817

    authors: Zhao J,Jin Y,Lu Y,Wang G

    更新日期:2009-03-01 00:00:00

  • Microwave image reconstruction utilizing log-magnitude and unwrapped phase to improve high-contrast object recovery.

    abstract::Reconstructing images of large high-contrast objects with microwave methods has proved difficult. Successful images have generally been obtained by using a priori information to constrain the image reconstruction to recover the correct electromagnetic property distribution. In these situations, the measured electric f...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.913177

    authors: Meaney PM,Paulsen KD,Pogue BW,Miga MI

    更新日期:2001-02-01 00:00:00

  • Mixture model analysis of DNA microarray images.

    abstract::In this paper, we propose a new methodology for analysis of microarray images. First, a new gridding algorithm is proposed for determining the individual spots and their borders. Then, a Gaussian mixture model (GMM) approach is presented for the analysis of the individual spot images. The main advantages of the propos...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/tmi.2005.848358

    authors: Blekas K,Galatsanos NP,Likas A,Lagaris IE

    更新日期:2005-07-01 00:00:00

  • Morphometric analysis of white matter lesions in MR images: method and validation.

    abstract::The analysis of MR images is evolving from qualitative to quantitative. More and more, the question asked by clinicians is how much and where, rather than a simple statement on the presence or absence of abnormalities. The authors present a study in which the results obtained with a semiautomatic, multispectral segmen...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.363096

    authors: Zijdenbos AP,Dawant BM,Margolin RA,Palmer AC

    更新日期:1994-01-01 00:00:00

  • Retinal vessel centerline extraction using multiscale matched filters, confidence and edge measures.

    abstract::Motivated by the goals of improving detection of low-contrast and narrow vessels and eliminating false detections at nonvascular structures, a new technique is presented for extracting vessels in retinal images. The core of the technique is a new likelihood ratio test that combines matched-filter responses, confidence...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/tmi.2006.884190

    authors: Sofka M,Stewart CV

    更新日期:2006-12-01 00:00:00

  • An improved algorithm for 2-D translational motion artifact correction.

    abstract::The quality of magnetic resonance imaging systems has improved to the point that motion is a major limitation in many examinations. Translational motion in the imaging plane causes the phase of the data to be corrupted. An algorithm using computer post-processing is proposed to correct the phase of the data, and hence...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.108589

    authors: Medley M,Yan H,Rosenfeld D

    更新日期:1991-01-01 00:00:00

  • Accurate event-driven motion compensation in high-resolution PET incorporating scattered and random events.

    abstract::With continuing improvements in spatial resolution of positron emission tomography (PET) scanners, small patient movements during PET imaging become a significant source of resolution degradation. This work develops and investigates a comprehensive formalism for accurate motion-compensated reconstruction which at the ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2008.917248

    authors: Rahmim A,Dinelle K,Cheng JC,Shilov MA,Segars WP,Lidstone SC,Blinder S,Rousset OG,Vajihollahi H,Tsui BM,Wong DF,Sossi V

    更新日期:2008-08-01 00:00:00

  • Interactions Between Large-Scale Functional Brain Networks are Captured by Sparse Coupled HMMs.

    abstract::Functional magnetic resonance imaging (fMRI) provides a window on the human brain at work. Spontaneous brain activity measured during resting-state has already provided many insights into brain function. In particular, recent interest in dynamic interactions between brain regions has increased the need for more advanc...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2017.2755369

    authors: Bolton TAW,Tarun A,Sterpenich V,Schwartz S,Van De Ville D

    更新日期:2018-01-01 00:00:00

  • General reconstruction theory for multislice X-ray computed tomography with a gantry tilt.

    abstract::This paper discusses image reconstruction with a tilted gantry in multislice computed tomography (CT) with helical (spiral) data acquisition. The reconstruction problem with gantry tilt is shown to be transformable into the problem of reconstructing a virtual object from multislice CT data with no gantry tilt, for whi...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2004.829337

    authors: Noo F,Defrise M,Kudo H

    更新日期:2004-09-01 00:00:00

  • Electrical impedance tomography using induced currents.

    abstract::The mathematical basis of a new imaging modality, induced current electrical impedance tomography (EIT), is investigated, The ultimate aim of this technique is the reconstruction of conductivity distribution of the human body, from voltage measurements made between electrodes placed on the surface, when currents are i...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.293927

    authors: Gencer NG,Kuzuoglu M,Ider YZ

    更新日期:1994-01-01 00:00:00

  • Compressive Deconvolution in Medical Ultrasound Imaging.

    abstract::The interest of compressive sampling in ultrasound imaging has been recently extensively evaluated by several research teams. Following the different application setups, it has been shown that the RF data may be reconstructed from a small number of measurements and/or using a reduced number of ultrasound pulse emissio...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2015.2493241

    authors: Chen Z,Basarab A,Kouamé D

    更新日期:2016-03-01 00:00:00

  • Compressed Sensing Doppler Ultrasound Reconstruction Using Block Sparse Bayesian Learning.

    abstract::In this paper we propose a framework for using duplex Doppler ultrasound systems. These type of systems need to interleave the acquisition and display of a B-mode image and of the pulsed Doppler spectrogram. In a recent study (Richy , 2013), we have shown that compressed sensing-based reconstruction of Doppler signal ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2015.2504240

    authors: Lorintiu O,Liebgott H,Friboulet D

    更新日期:2016-04-01 00:00:00

  • Curvelet based contrast enhancement in fluoroscopic sequences.

    abstract::Image guided interventions have seen growing interest in recent years. The use of X-rays for the procedure impels limiting the dose over time. Image sequences obtained thereby exhibit high levels of noise and very low contrasts. Hence, the development of efficient methods to enable optimal visualization of these seque...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2014.2349034

    authors: Amiot C,Girard C,Chanussot J,Pescatore J,Desvignes M

    更新日期:2015-01-01 00:00:00

  • Improved methods to determine optimal currents in electrical impedance tomography.

    abstract::An electrical impedance tomography (EIT) system that uses the optimal current method to inject currents and the regularized Newton-Raphson algorithm to reconstruct an image of resistivity distribution is discussed. Iterative methods to derive the optimal current patterns through iterative physical measurements are dev...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.192684

    authors: Hua P,Woo EJ,Webster JG,Tompkins WJ

    更新日期:1992-01-01 00:00:00

  • Local noise weighted filtering for emphysema scoring of low-dose CT images.

    abstract::Computed tomography (CT) has become the new reference standard for quantification of emphysema. The most popular measure of emphysema derived from CT is the pixel index (PI), which expresses the fraction of the lung volume with abnormally low intensity values. As PI is calculated from a single, fixed threshold on inte...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2006.871545

    authors: Schilham AM,van Ginneken B,Gietema H,Prokop M

    更新日期:2006-04-01 00:00:00

  • Automated abdominal multi-organ segmentation with subject-specific atlas generation.

    abstract::A robust automated segmentation of abdominal organs can be crucial for computer aided diagnosis and laparoscopic surgery assistance. Many existing methods are specialized to the segmentation of individual organs and struggle to deal with the variability of the shape and position of abdominal organs. We present a gener...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2013.2265805

    authors: Wolz R,Chu C,Misawa K,Fujiwara M,Mori K,Rueckert D

    更新日期:2013-09-01 00:00:00

  • Precise robot-assisted guide positioning for distal locking of intramedullary nails.

    abstract::This paper presents a novel image-guided robot-based system to assist orthopedic surgeons in performing distal locking of long bone intramedullary nails. The system consists of a bone-mounted miniature robot fitted with a drill guide that provides rigid mechanical guidance for hand-held drilling of the distal screws' ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2005.844922

    authors: Yaniv Z,Joskowicz L

    更新日期:2005-05-01 00:00:00

  • Automated detection of prostatic adenocarcinoma from high-resolution ex vivo MRI.

    abstract::Prostatic adenocarcinoma is the most commonly occurring cancer among men in the United States, second only to skin cancer. Currently, the only definitive method to ascertain the presence of prostatic cancer is by trans-rectal ultrasound (TRUS) directed biopsy. Owing to the poor image quality of ultrasound, the accurac...

    journal_title:IEEE transactions on medical imaging

    pub_type: 临床试验,杂志文章

    doi:10.1109/TMI.2005.859208

    authors: Madabhushi A,Feldman MD,Metaxas DN,Tomaszeweski J,Chute D

    更新日期:2005-12-01 00:00:00

  • Augmented Likelihood Image Reconstruction.

    abstract::The presence of high-density objects remains an open problem in medical CT imaging. Data of projections passing through objects of high density, such as metal implants, are dominated by noise and are highly affected by beam hardening and scatter. Reconstructed images become less diagnostically conclusive because of pr...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2015.2459764

    authors: Stille M,Kleine M,Hägele J,Barkhausen J,Buzug TM

    更新日期:2016-01-01 00:00:00

  • Spherical Deformable U-Net: Application to Cortical Surface Parcellation and Development Prediction.

    abstract::Convolutional Neural Networks (CNNs) have achieved overwhelming success in learning-related problems for 2D/3D images in the Euclidean space. However, unlike in the Euclidean space, the shapes of many structures in medical imaging have an inherent spherical topology in a manifold space, e.g., the convoluted brain cort...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2021.3050072

    authors: Zhao F,Wu Z,Wang L,Lin W,Gilmore JH,Xia S,Shen D,Li G

    更新日期:2021-01-08 00:00:00

  • Sparse patch-based label propagation for accurate prostate localization in CT images.

    abstract::In this paper, we propose a new prostate computed tomography (CT) segmentation method for image guided radiation therapy. The main contributions of our method lie in the following aspects. 1) Instead of using voxel intensity information alone, patch-based representation in the discriminative feature space with logisti...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2012.2230018

    authors: Liao S,Gao Y,Lian J,Shen D

    更新日期:2013-02-01 00:00:00

  • Reconstruction of dielectric permittivity distributions in arbitrary 2-D inhomogeneous biological bodies by a multiview microwave numerical method.

    abstract::A numerical method for microwave imaging of two-dimensional inhomogeneous biological bodies illuminated by TM waves is presented. It is a spatial-domain multiview approach which makes use of the moment method to discretize the integral-equation formulation of inverse scattering. A pseudoinversion technique is applied ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.232251

    authors: Caorsi S,Gragnani GL,Pastorino M

    更新日期:1993-01-01 00:00:00

  • Segmentation of the optic disc, macula and vascular arch in fundus photographs.

    abstract::An automatic system is presented to find the location of the major anatomical structures in color fundus photographs; the optic disc, the macula, and the vascular arch. These structures are found by fitting a single point-distribution-model to the image, that contains points on each structure. The method can handle op...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2006.885336

    authors: Niemeijer M,Abràmoff MD,van Ginneken B

    更新日期:2007-01-01 00:00:00

  • Image reconstruction in magnetic resonance conductivity tensor imaging (MRCTI).

    abstract::Almost all magnetic resonance electrical impedance tomography (MREIT) reconstruction algorithms proposed to date assume isotropic conductivity in order to simplify the image reconstruction. However, it is well known that most of biological tissues have anisotropic conductivity values. In this study, four novel anisotr...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2011.2171192

    authors: Değirmenci E,Eyüboğlu BM

    更新日期:2012-03-01 00:00:00

  • Improving Registration Robustness for Image-Guided Liver Surgery in a Novel Human-to-Phantom Data Framework.

    abstract::In open image-guided liver surgery (IGLS), a sparse representation of the intraoperative organ surface can be acquired to drive image-to-physical registration. We hypothesize that uncharacterized error induced by variation in the collection patterns of organ surface data limits the accuracy and robustness of an IGLS r...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2017.2668842

    authors: Collins JA,Weis JA,Heiselman JS,Clements LW,Simpson AL,Jarnagin WR,Miga MI

    更新日期:2017-07-01 00:00:00

  • NMR velocity-selective excitation composites for flow and motion imaging and suppression of static tissue signal.

    abstract::We propose a technique aimed at increasing the sensitivity of magnetic resonance imaging (MRI) measurements to the signal from moving material. The technique is formulated within the framework of a velocity phase-encoding strategy. The salient new feature of the protocol is the application of an excitation pulse, foll...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.1987.4307814

    authors: Moran PR,Saloner D,Tsui BW

    更新日期:1987-01-01 00:00:00