Diffuse optical tomography enhanced by clustered sparsity for functional brain imaging.

Abstract:

:Diffuse optical tomography (DOT) is a noninvasive technique which measures hemodynamic changes in the tissue with near infrared light, which has been increasingly used to study brain functions. Due to the nature of light propagation in the tissue, the reconstruction problem is severely ill-posed. For linearized DOT problems, sparsity regularization has achieved promising results over conventional Tikhonov regularization in recent experimental research. As extensions to standard sparsity, it is widely known that structured sparsity based methods are often superior in terms of reconstruction accuracy, when the data follows some structures. In this paper, we exploit the structured sparsity of diffuse optical images. Based on the functional specialization of the brain, it is observed that the in vivo absorption changes caused by a specific brain function would be clustered in certain region(s) and not randomly distributed. Thus, a new algorithm is proposed for this clustered sparsity reconstruction (CSR). Results of numerical simulations and phantom experiments have demonstrated the superiority of the proposed method over the state-of-the-art methods. An example from human in vivo measurements further confirmed the advantages of the proposed CSR method.

journal_name

IEEE Trans Med Imaging

authors

Chen C,Tian F,Liu H,Huang J

doi

10.1109/TMI.2014.2338214

subject

Has Abstract

pub_date

2014-12-01 00:00:00

pages

2323-31

issue

12

eissn

0278-0062

issn

1558-254X

journal_volume

33

pub_type

杂志文章
  • Fast catheter segmentation from echocardiographic sequences based on segmentation from corresponding X-ray fluoroscopy for cardiac catheterization interventions.

    abstract::Echocardiography is a potential alternative to X-ray fluoroscopy in cardiac catheterization given its richness in soft tissue information and its lack of ionizing radiation. However, its small field of view and acoustic artifacts make direct automatic segmentation of the catheters very challenging. In this study, a fa...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2014.2360988

    authors: Wu X,Housden J,Ma Y,Razavi B,Rhode K,Rueckert D

    更新日期:2015-04-01 00:00:00

  • Surface Reconstruction for free-space 360 degrees fluorescence molecular tomography and the effects of animal motion.

    abstract::Complete projection (360 degrees ) free-space fluorescence tomography of opaque media is poised to enable 3-D imaging through entire small animals in vivo with improved depth resolution compared to 360 degrees -projection fiber-based systems or limited-view angle systems. This approach can lead to a new generation of ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2007.904662

    authors: Lasser T,Soubret A,Ripoll J,Ntziachristos V

    更新日期:2008-02-01 00:00:00

  • Estimation of Strain Elastography from Ultrasound Radio-Frequency Data by Utilizing Analytic Gradient of the Similarity Metric.

    abstract::Most strain imaging techniques follow a pipeline strategy: in the first step, tissue displacement is estimated from radio-frequency (RF) frames, and in the second step, a spatial derivative operation is applied. There are two main issues that arise from this framework. First, the gradient operation amplifies noise, an...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2017.2685522

    authors: Omidyeganeh M,Xiao Y,Ahmad MO,Rivaz H

    更新日期:2017-06-01 00:00:00

  • In situ characterization of the degradation of PLGA microspheres in hyaluronic acid hydrogels by optical coherence tomography.

    abstract::The polymeric implant material poly(lactide-co-glycolide) (PLGA) degrades by a process of bulk degradation, which allows it to be used for the controlled release of therapeutic molecules from implants and microspheres. The temporal characterization of PLGA microsphere degradation has been limited by the need to destru...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2008.927356

    authors: Patterson J,Stayton PS,Li X

    更新日期:2009-01-01 00:00:00

  • Imaging the distribution of magnetic nanoparticles with ultrasound.

    abstract::Magnetic nanoparticles can be caused to oscillate under the influence of an incident ultrasonic wave. If the particles are momentarily aligned with a magnetizing pulse creating a macroscopic magnetization, this oscillation will result in a time-varying magnetic moment which should be detectable as an induced voltage i...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2007.895476

    authors: Norton SJ,Vo-Dinh T

    更新日期:2007-05-01 00:00:00

  • Sparse patch-based label propagation for accurate prostate localization in CT images.

    abstract::In this paper, we propose a new prostate computed tomography (CT) segmentation method for image guided radiation therapy. The main contributions of our method lie in the following aspects. 1) Instead of using voxel intensity information alone, patch-based representation in the discriminative feature space with logisti...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2012.2230018

    authors: Liao S,Gao Y,Lian J,Shen D

    更新日期:2013-02-01 00:00:00

  • A Predictive Model of Vertebral Trabecular Anisotropy From Ex Vivo Micro-CT.

    abstract::Spine-related disorders are amongst the most frequently encountered problems in clinical medicine. For several applications such as 1) to improve the assessment of the strength of the spine, as well as 2) to optimize the personalization of spinal interventions, image-based biomechanical modeling of the vertebrae is ex...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2014.2387114

    authors: Lekadir K,Hoogendoorn C,Hazrati-Marangalou J,Taylor Z,Noble C,van Rietbergen B,Frangi AF

    更新日期:2015-08-01 00:00:00

  • Sparse-view spectral CT reconstruction using spectral patch-based low-rank penalty.

    abstract::Spectral computed tomography (CT) is a promising technique with the potential for improving lesion detection, tissue characterization, and material decomposition. In this paper, we are interested in kVp switching-based spectral CT that alternates distinct kVp X-ray transmissions during gantry rotation. This system can...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2014.2380993

    authors: Kim K,Ye JC,Worstell W,Ouyang J,Rakvongthai Y,El Fakhri G,Li Q

    更新日期:2015-03-01 00:00:00

  • Quantitative Susceptibility Mapping Using Structural Feature Based Collaborative Reconstruction (SFCR) in the Human Brain.

    abstract::The reconstruction of MR quantitative susceptibility mapping (QSM) from local phase measurements is an ill posed inverse problem and different regularization strategies incorporating a priori information extracted from magnitude and phase images have been proposed. However, the anatomy observed in magnitude and phase ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2016.2544958

    authors: Bao L,Li X,Cai C,Chen Z,van Zijl PC

    更新日期:2016-09-01 00:00:00

  • Quantifying the statistical impact of GRAPPA in fcMRI data with a real-valued isomorphism.

    abstract::The interpolation of missing spatial frequencies through the generalized auto-calibrating partially parallel acquisitions (GRAPPA) parallel magnetic resonance imaging (MRI) model implies a correlation is induced between the acquired and reconstructed frequency measurements. As the parallel image reconstruction algorit...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2013.2288521

    authors: Bruce IP,Rowe DB

    更新日期:2014-02-01 00:00:00

  • Digital mammography: mixed feature neural network with spectral entropy decision for detection of microcalcifications.

    abstract::A computationally efficient mixed feature based neural network (MFNN) is proposed for the detection of microcalcification clusters (MCCs) in digitized mammograms. The MFNN employs features computed in both the spatial and spectral domain and uses spectral entropy as a decision parameter. Backpropagation with Kalman fi...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.538936

    authors: Zheng B,Qian W,Clarke LP

    更新日期:1996-01-01 00:00:00

  • Computer Aided Theragnosis Using Quantitative Ultrasound Spectroscopy and Maximum Mean Discrepancy in Locally Advanced Breast Cancer.

    abstract::A noninvasive computer-aided-theragnosis (CAT) system was developed for the early therapeutic cancer response assessment in patients with locally advanced breast cancer (LABC) treated with neoadjuvant chemotherapy. The proposed CAT system was based on multi-parametric quantitative ultrasound (QUS) spectroscopic method...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2015.2495246

    authors: Gangeh MJ,Tadayyon H,Sannachi L,Sadeghi-Naini A,Tran WT,Czarnota GJ

    更新日期:2016-03-01 00:00:00

  • Evaluation of a Quantitative Method for Carpal Motion Analysis Using Clinical 3-D and 4-D CT Protocols.

    abstract::For wrist complaints related to motion, a 2-D radiograph or CT scan of the static wrist may not always be considered diagnostic. 3-D motion imaging, i.e., multiple 3DCT scans in time (4DCT), enables quantifying carpal motion and comparing motion patterns of the affected wrist with those of the healthy contralateral si...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2018.2877503

    authors: Dobbe JGG,de Roo MGA,Visschers JC,Strackee SD,Streekstra GJ

    更新日期:2019-04-01 00:00:00

  • Multi-TI Arterial Spin Labeling MRI with Variable TR and Bolus Duration for Cerebral Blood Flow and Arterial Transit Time Mapping.

    abstract::Arterial spin labeling (ASL) is an MRI perfusion imaging method from which quantitative cerebral blood flow (CBF) can be calculated. We present a multi-TI ASL method (multi-TI integrated ASL) in which variable post-labeling delays and variable TRs are used to improve the estimation of arterial transit time (ATT) and C...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2015.2395257

    authors: Johnston ME,Lu K,Maldjian JA,Jung Y

    更新日期:2015-06-01 00:00:00

  • Robust parameter estimation of intensity distributions for brain magnetic resonance images.

    abstract::This paper presents two new methods for robust parameter estimation of mixtures in the context of magnetic resonance (MR) data segmentation. The head is constituted of different types of tissue that can be modeled by a finite mixture of multivariate Gaussian distributions. Our goal is to estimate accurately the statis...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.700730

    authors: Schroeter P,Vesin JM,Langenberger T,Meuli R

    更新日期:1998-04-01 00:00:00

  • Two iterative image restoration algorithms with applications to nuclear medicine.

    abstract::Two methods for recovering an image that has been degraded while being processed are presented. The restoration problem is formulated as a constrained optimization problem in which a measure of smoothness based on the second derivatives of the restored image is maximized subject to the constraint that noise energy is ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.126904

    authors: Charalambous C,Ghaddar FK,Kouris K

    更新日期:1992-01-01 00:00:00

  • Estimation of the hemodynamic response in event-related functional MRI: Bayesian networks as a framework for efficient Bayesian modeling and inference.

    abstract::A convenient way to analyze blood-oxygen-level-dependent functional magnetic resonance imaging data consists of modeling the whole brain as a stationary, linear system characterized by its transfer function: the hemodynamic response function (HRF). HRF estimation, though of the greatest interest, is still under invest...

    journal_title:IEEE transactions on medical imaging

    pub_type: 临床试验,杂志文章

    doi:10.1109/TMI.2004.831221

    authors: Marrelec G,Ciuciu P,Pélégrini-Issac M,Benali H

    更新日期:2004-08-01 00:00:00

  • Feature extraction in carpal-bone analysis.

    abstract::Hand-bone analysis with image processing techniques using a digital radiograph can be used to assess skeletal age. The analysis consists of two steps: phalangeal and carpal bone analysis. The carpal bone analysis is discussed. First, the carpal bone region of interest (CROI) is defined using a standard thresholding te...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.222665

    authors: Pietka E,Kaabi L,Kuo ML,Huang HK

    更新日期:1993-01-01 00:00:00

  • Standing-wave and RF penetration artifacts caused by elliptic geometry: an electrodynamic analysis of MRI.

    abstract::Motivated by the observation that the diagonal pattern of intensity nonuniformity usually associated with linearly polarized radio-frequency (RF) coils is often present in neurological scans using circularly polarized coils, a theoretical analysis has been conducted of the intensity nonuniformity inherent in imaging a...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.730409

    authors: Sled JG,Pike GB

    更新日期:1998-08-01 00:00:00

  • Time delay for arrival of MR contrast agent in collateral-dependent myocardium.

    abstract::An analysis of the kinetics of myocardial contrast enhancement is an important component of myocardial perfusion studies. The contrast enhancement can be modeled by a linear time-invariant system, and the myocardial impulse response, calculated by deconvolution of the measured tissue response with an arterial input, g...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2004.827969

    authors: Jerosch-Herold M,Hu X,Murthy NS,Seethamraju RT

    更新日期:2004-07-01 00:00:00

  • Real-Time Gain Control of PET Detectors and Evaluation With Challenging Radionuclides.

    abstract::Accurate gain control of PET detectors is a prerequisite for quantitative accuracy. A shift in the 511 keV peak position can lead to errors in scatter correction, degrading quantitation. The PET detectors in a PET/MR scanner are subject to thermal transients due to eddy currents induced during gradient-intensive MRI s...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2020.3022321

    authors: Jansen FP,Deller TW,Fries MD,Khalighi MM,White SL,Radford LL,McConathy JE,Lapi SE

    更新日期:2021-01-01 00:00:00

  • A geometry-driven optical flow warping for spatial normalization of cortical surfaces.

    abstract::Spatial normalization is frequently used to map data to a standard coordinate system by removing intersubject morphological differences, thereby allowing for group analysis to be carried out. The work presented in this paper is motivated by the need for an automated cortical surface normalization technique that will a...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2008.925080

    authors: Tosun D,Prince JL

    更新日期:2008-12-01 00:00:00

  • Elastic registration in the presence of intensity variations.

    abstract::We have developed a general-purpose registration algorithm for medical images and volumes. This method models the transformation between images as locally affine but globally smooth. The model also explicitly accounts for local and global variations in image intensities. This approach is built upon a differential mult...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2003.815069

    authors: Periaswamy S,Farid H

    更新日期:2003-07-01 00:00:00

  • FiloGen: A Model-Based Generator of Synthetic 3-D Time-Lapse Sequences of Single Motile Cells With Growing and Branching Filopodia.

    abstract::The existence of diverse image datasets accompanied by reference annotations is a crucial prerequisite for an objective benchmarking of bioimage analysis methods. Nevertheless, such a prerequisite is hard to satisfy for time lapse, multidimensional fluorescence microscopy image data, manual annotations of which are la...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2018.2845884

    authors: Sorokin DV,Peterlik I,Ulman V,Svoboda D,Necasova T,Morgaenko K,Eiselleova L,Tesarova L,Maska M

    更新日期:2018-12-01 00:00:00

  • Robust simultaneous detection of coronary borders in complex images.

    abstract::Visual estimation of coronary obstruction severity from angiograms suffers from poor inter- and intraobserver reproducibility and is often inaccurate. In spite of the widely recognized limitations of visual analysis, automated methods have not found widespread clinical use, in part because they too frequently fail to ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.370412

    authors: Sonka M,Winniford MD,Collins SM

    更新日期:1995-01-01 00:00:00

  • Head Motion Correction Based on Filtered Backprojection in Helical CT Scanning.

    abstract::Head motion may unexpectedly occur during a CT scan. It thereby results in motion artifacts in a reconstructed image and may lead to a false diagnosis or a failure of diagnosis. To alleviate this motion problem, as a hardware approach, increasing the gantry rotation speed or using an immobilization device is usually c...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2019.2953974

    authors: Jang S,Kim S,Kim M,Son K,Lee KY,Ra JB

    更新日期:2020-05-01 00:00:00

  • Joint Multi-Modal Longitudinal Regression and Classification for Alzheimer's Disease Prediction.

    abstract::Alzheimer's disease (AD) is a serious neurodegenerative condition that affects millions of individuals across the world. As the average age of individuals in the United States and the world increases, the prevalence of AD will continue to grow. To address this public health problem, the research community has develope...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2019.2958943

    authors: Brand L,Nichols K,Wang H,Shen L,Huang H

    更新日期:2020-06-01 00:00:00

  • Unsupervised Myocardial Segmentation for Cardiac BOLD.

    abstract::A fully automated 2-D+time myocardial segmentation framework is proposed for cardiac magnetic resonance (CMR) blood-oxygen-level-dependent (BOLD) data sets. Ischemia detection with CINE BOLD CMR relies on spatio-temporal patterns in myocardial intensity, but these patterns also trouble supervised segmentation methods,...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2017.2726112

    authors: Oksuz I,Mukhopadhyay A,Dharmakumar R,Tsaftaris SA

    更新日期:2017-11-01 00:00:00

  • General reconstruction theory for multislice X-ray computed tomography with a gantry tilt.

    abstract::This paper discusses image reconstruction with a tilted gantry in multislice computed tomography (CT) with helical (spiral) data acquisition. The reconstruction problem with gantry tilt is shown to be transformable into the problem of reconstructing a virtual object from multislice CT data with no gantry tilt, for whi...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2004.829337

    authors: Noo F,Defrise M,Kudo H

    更新日期:2004-09-01 00:00:00

  • A fast Bayesian reconstruction algorithm for emission tomography with entropy prior converging to feasible images.

    abstract::The development and tests of an iterative reconstruction algorithm for emission tomography based on Bayesian statistical concepts are described. The algorithm uses the entropy of the generated image as a prior distribution, can be accelerated by the choice of an exponent, and converges uniformly to feasible images by ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.56340

    authors: Nunez J,Llacer J

    更新日期:1990-01-01 00:00:00