Accurate localization of optic radiation during neurosurgery in an interventional MRI suite.

Abstract:

:Accurate localization of the optic radiation is key to improving the surgical outcome for patients undergoing anterior temporal lobe resection for the treatment of refractory focal epilepsy. Current commercial interventional magnetic resonance imaging (MRI) scanners are capable of performing anatomical and diffusion weighted imaging and are used for guidance during various neurosurgical procedures. We present an interventional imaging workflow that can accurately localize the optic radiation during surgery. The workflow is driven by a near real-time multichannel nonrigid image registration algorithm that uses both anatomical and fractional anisotropy pre- and intra-operative images. The proposed workflow is implemented on graphical processing units and we perform a warping of the pre-operatively parcellated optic radiation to the intra-operative space in under 3 min making the proposed algorithm suitable for use under the stringent time constraints of neurosurgical procedures. The method was validated using both a numerical phantom and clinical data using pre- and post-operative images from patients who had undergone surgery for treatment of refractory focal epilepsy and shows strong correlation between the observed post-operative visual field deficit and the predicted damage to the optic radiation. We also validate the algorithm using interventional MRI datasets from a small cohort of patients. This work could be of significant utility in image guided interventions and facilitate effective surgical treatments.

journal_name

IEEE Trans Med Imaging

authors

Daga P,Winston G,Modat M,White M,Mancini L,Cardoso MJ,Symms M,Stretton J,McEvoy AW,Thornton J,Micallef C,Yousry T,Hawkes DJ,Duncan JS,Ourselin S

doi

10.1109/TMI.2011.2179668

subject

Has Abstract

pub_date

2012-04-01 00:00:00

pages

882-91

issue

4

eissn

0278-0062

issn

1558-254X

journal_volume

31

pub_type

杂志文章
  • Image Registration Based on Low Rank Matrix: Rank-Regularized SSD.

    abstract::Similarity measure is a main core of image registration algorithms. Spatially varying intensity distortion is an important challenge, which affects the performance of similarity measures. Correlation among the pixels is the main characteristic of this distortion. Similarity measures such as sum-of-squared-differences ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2017.2744663

    authors: Ghaffari A,Fatemizadeh E

    更新日期:2018-01-01 00:00:00

  • Soft tissue differentiation using multiband signatures of high resolution ultrasonic transmission tomography.

    abstract::In this paper, we are interested in soft tissue differentiation by multiband images obtained from the High-Resolution Ultrasonic Transmission Tomography (HUTT) system using a spectral target detection method based on constrained energy minimization (CEM). We have developed a new tissue differentiation method (called "...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/tmi.2004.843179

    authors: Jeong JW,Kim TS,Shin DC,Do S,Singh M,Marmarelis VZ

    更新日期:2005-03-01 00:00:00

  • Computer-assisted scan protocol and reconstruction (CASPAR)-reduction of image noise and patient dose.

    abstract::X-ray computed tomography is a powerful medical imaging device. It allows high-resolution 3-D visualization of the human body. However, one drawback is the health risk associated with ionizing radiation. Simply downscaling the radiation intensities over the entire scan results in increased quantum noise. This paper pr...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2009.2034515

    authors: Sperl J,Beque D,Claus B,De Man B,Senzig B,Brokate M

    更新日期:2010-03-01 00:00:00

  • A fast Bayesian reconstruction algorithm for emission tomography with entropy prior converging to feasible images.

    abstract::The development and tests of an iterative reconstruction algorithm for emission tomography based on Bayesian statistical concepts are described. The algorithm uses the entropy of the generated image as a prior distribution, can be accelerated by the choice of an exponent, and converges uniformly to feasible images by ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.56340

    authors: Nunez J,Llacer J

    更新日期:1990-01-01 00:00:00

  • Segmentation of prostate boundaries from ultrasound images using statistical shape model.

    abstract::This paper presents a statistical shape model for the automatic prostate segmentation in transrectal ultrasound images. A Gabor filter bank is first used to characterize the prostate boundaries in ultrasound images in both multiple scales and multiple orientations. The Gabor features are further reconstructed to be in...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2003.809057

    authors: Shen D,Zhan Y,Davatzikos C

    更新日期:2003-04-01 00:00:00

  • A hardware architecture using finite-field arithmetic for computing maximum-likelihood estimates in emission tomography.

    abstract::A special-purpose hardware architecture is proposed to implement the expectation-maximization algorithm to compute, in clinically useful times, the maximum-likelihood estimate of a radionuclide distribution for a positron-emission tomogram from time-of-flight measurements. Two-dimensional convolutions required for for...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.14510

    authors: Klotz HR,Snyder DL

    更新日期:1988-01-01 00:00:00

  • The adaptive bases algorithm for intensity-based nonrigid image registration.

    abstract::Nonrigid registration of medical images is important for a number of applications such as the creation of population averages, atlas-based segmentation, or geometric correction of functional magnetic resonance imaging (fMRI) images to name a few. In recent years, a number of methods have been proposed to solve this pr...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2003.819299

    authors: Rohde GK,Aldroubi A,Dawant BM

    更新日期:2003-11-01 00:00:00

  • Association Between Changes in Mammographic Image Features and Risk for Near-Term Breast Cancer Development.

    abstract::The purpose of this study is to develop and test a new computerized model for predicting near-term breast cancer risk based on quantitative assessment of bilateral mammographic image feature variations in a series of negative full-field digital mammography (FFDM) images. The retrospective dataset included series of fo...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2016.2527619

    authors: Tan M,Zheng B,Leader JK,Gur D

    更新日期:2016-07-01 00:00:00

  • Spatio-temporal nonrigid registration for ultrasound cardiac motion estimation.

    abstract::We propose a new spatio-temporal elastic registration algorithm for motion reconstruction from a series of images. The specific application is to estimate displacement fields from two-dimensional ultrasound sequences of the heart. The basic idea is to find a spatio-temporal deformation field that effectively compensat...

    journal_title:IEEE transactions on medical imaging

    pub_type: 临床试验,杂志文章

    doi:10.1109/TMI.2005.852050

    authors: Ledesma-Carbayo MJ,Kybic J,Desco M,Santos A,Sühling M,Hunziker P,Unser M

    更新日期:2005-09-01 00:00:00

  • Automatic construction of 3D-ASM intensity models by simulating image acquisition: application to myocardial gated SPECT studies.

    abstract::Active shape models bear a great promise for model-based medical image analysis. Their practical use, though, is undermined due to the need to train such models on large image databases. Automatic building of point distribution models (PDMs) has been successfully addressed and a number of autolandmarking techniques ar...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2008.2004819

    authors: Tobon-Gomez C,Butakoff C,Aguade S,Sukno F,Moragas G,Frangi AF

    更新日期:2008-11-01 00:00:00

  • Accuracy of the morphology enabled dipole inversion (MEDI) algorithm for quantitative susceptibility mapping in MRI.

    abstract::Determining the susceptibility distribution from the magnetic field measured in a magnetic resonance (MR) scanner is an ill-posed inverse problem, because of the presence of zeroes in the convolution kernel in the forward problem. An algorithm called morphology enabled dipole inversion (MEDI), which incorporates spati...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2011.2182523

    authors: Liu T,Xu W,Spincemaille P,Avestimehr AS,Wang Y

    更新日期:2012-03-01 00:00:00

  • Real-Time Gain Control of PET Detectors and Evaluation With Challenging Radionuclides.

    abstract::Accurate gain control of PET detectors is a prerequisite for quantitative accuracy. A shift in the 511 keV peak position can lead to errors in scatter correction, degrading quantitation. The PET detectors in a PET/MR scanner are subject to thermal transients due to eddy currents induced during gradient-intensive MRI s...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2020.3022321

    authors: Jansen FP,Deller TW,Fries MD,Khalighi MM,White SL,Radford LL,McConathy JE,Lapi SE

    更新日期:2021-01-01 00:00:00

  • Using a visual discrimination model for the detection of compression artifacts in virtual pathology images.

    abstract::A major issue in telepathology is the extremely large and growing size of digitized "virtual" slides, which can require several gigabytes of storage and cause significant delays in data transmission for remote image interpretation and interactive visualization by pathologists. Compression can reduce this massive amoun...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2010.2077308

    authors: Johnson JP,Krupinski EA,Yan M,Roehrig H,Graham AR,Weinstein RS

    更新日期:2011-02-01 00:00:00

  • ERS transform for the automated detection of bronchial abnormalities on CT of the lungs.

    abstract::The identification of bronchi on Computed Tomography (CT) images of the lungs provides valuable clinical information in patients with suspected airways diseases including bronchiectasis, emphysema, or constrictive obliterative bronchiolitis. The automated recognition of the airways is, therefore, an important part of ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.952731

    authors: Chabat F,Hu XP,Hansell DM,Yang GZ

    更新日期:2001-09-01 00:00:00

  • Estimating 3-D respiratory motion from orbiting views by tomographic image registration.

    abstract::Respiratory motion remains a significant source of errors in treatment planning for the thorax and upper abdomen. Recently, we proposed a method to estimate two-dimensional (2-D) object motion from a sequence of slowly rotating X-ray projection views, which we called deformation from orbiting views (DOVs). In this met...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2006.889719

    authors: Zeng R,Fessler JA,Balter JM

    更新日期:2007-02-01 00:00:00

  • 3-D reconstruction of tissue components for atherosclerotic human arteries using ex vivo high-resolution MRI.

    abstract::Automatic computer-based methods are well suited for the image analysis of the different components in atherosclerotic plaques. Although several groups work on such analysis some of the methods used are oversimplified and require improvements when used within a computational framework for predicting meaningful stress ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2006.870485

    authors: Auer M,Stollberger R,Regitnig P,Ebner F,Holzapfel GA

    更新日期:2006-03-01 00:00:00

  • PET image reconstruction using information theoretic anatomical priors.

    abstract::We describe a nonparametric framework for incorporating information from co-registered anatomical images into positron emission tomographic (PET) image reconstruction through priors based on information theoretic similarity measures. We compare and evaluate the use of mutual information (MI) and joint entropy (JE) bet...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2010.2076827

    authors: Somayajula S,Panagiotou C,Rangarajan A,Li Q,Arridge SR,Leahy RM

    更新日期:2011-03-01 00:00:00

  • Deformable registration of glioma images using EM algorithm and diffusion reaction modeling.

    abstract::This paper investigates the problem of atlas registration of brain images with gliomas. Multiparametric imaging modalities (T1, T1-CE, T2, and FLAIR) are first utilized for segmentations of different tissues, and to compute the posterior probability map (PBM) of membership to each tissue class, using supervised learni...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2010.2078833

    authors: Gooya A,Biros G,Davatzikos C

    更新日期:2011-02-01 00:00:00

  • Low-Rank Atlas Image Analyses in the Presence of Pathologies.

    abstract::We present a common framework, for registering images to an atlas and for forming an unbiased atlas, that tolerates the presence of pathologies such as tumors and traumatic brain injury lesions. This common framework is particularly useful when a sufficient number of protocol-matched scans from healthy subjects cannot...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2015.2448556

    authors: Liu X,Niethammer M,Kwitt R,Singh N,McCormick M,Aylward S

    更新日期:2015-12-01 00:00:00

  • Cap-Based Transcranial Optical Tomography in an Awake Infant.

    abstract::Although Blood Oxygenation Level Dependent (BOLD) functional MRI (fMRI) is widely used to examine brain function in adults, the need for general anesthesia limits its practical utility in infants and small children. Functional Near-Infrared Spectroscopy - Diffuse Optical Tomography (fNIRS-DOT) imaging promises to be a...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2020.2990823

    authors: Zhu B,Sevick-Muraca EM,Nguyen RD,Shah MN

    更新日期:2020-11-01 00:00:00

  • Three-dimensional segmentation and growth-rate estimation of small pulmonary nodules in helical CT images.

    abstract::Small pulmonary nodules are a common radiographic finding that presents an important diagnostic challenge in contemporary medicine. While pulmonary nodules are the major radiographic indicator of lung cancer, they may also be signs of a variety of benign conditions. Measurement of nodule growth rate over time has been...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2003.817785

    authors: Kostis WJ,Reeves AP,Yankelevitz DF,Henschke CI

    更新日期:2003-10-01 00:00:00

  • Estimating kinetic parameter maps from dynamic contrast-enhanced MRI using spatial prior knowledge.

    abstract::Dynamic contrast-enhanced magnetic resonance (DCE-MR) imaging can be used to study microvascular structure in vivo by monitoring the abundance of an injected diffusible contrast agent over time. The resulting spatially resolved intensity-time curves are usually interpreted in terms of kinetic parameters obtained by fi...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2009.2019957

    authors: Kelm BM,Menze BH,Nix O,Zechmann CM,Hamprecht FA

    更新日期:2009-10-01 00:00:00

  • A proposed taxonomy for nailfold capillaries based on their morphology.

    abstract::Certain diseases cause permanent changes to the shapes and densities of nailfold capillaries and, therefore, nailfold capillaroscopy is important as a tool for diagnosing and monitoring these diseases. The first aim of the project is to resolve differences in terminology that have developed over the years in previous ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.921482

    authors: Jones BF,Oral M,Morris CW,Ring EF

    更新日期:2001-04-01 00:00:00

  • Time-frequency MEG-MUSIC algorithm.

    abstract::We propose a method that incorporates the time-frequency characteristics of neural sources into magnetoencephalographic (MEG) source estimation. The method is based on the multiple-signal-classification (MUSIC) algorithm and it calculates a time--frequency matrix in which diagonal and off-diagonal terms are the auto a...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.750262

    authors: Sekihara K,Nagarajan S,Poeppel D,Miyashita Y

    更新日期:1999-01-01 00:00:00

  • Sufficient statistics as a generalization of binning in spectral X-ray imaging.

    abstract::It is well known that the energy dependence of X-ray attenuation can be used to characterize materials. Yet, even with energy discriminating photon counting X-ray detectors, it is still unclear how to best form energy dependent measurements for spectral imaging. Common ideas include binning photon counts based on thei...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2010.2061862

    authors: Wang AS,Pelc NJ

    更新日期:2011-01-01 00:00:00

  • An Inverse Problems Approach to MR-EPT Image Reconstruction.

    abstract::Magnetic Resonance-Electrical Properties Tomography (MR-EPT) is an imaging modality that maps the spatial distribution of the electrical conductivity and permittivity using standard MRI systems. The presence of a body within the scanner alters the RF field, and by mapping these alterations it is possible to recover th...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2015.2466082

    authors: Borsic A,Perreard I,Mahara A,Halter RJ

    更新日期:2016-01-01 00:00:00

  • Graph-based multi-surface segmentation of OCT data using trained hard and soft constraints.

    abstract::Optical coherence tomography (OCT) is a well-established image modality in ophthalmology and used daily in the clinic. Automatic evaluation of such datasets requires an accurate segmentation of the retinal cell layers. However, due to the naturally low signal to noise ratio and the resulting bad image quality, this ta...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2012.2225152

    authors: Dufour PA,Ceklic L,Abdillahi H,Schröder S,De Dzanet S,Wolf-Schnurrbusch U,Kowal J

    更新日期:2013-03-01 00:00:00

  • Electrical impedance tomography using induced currents.

    abstract::The mathematical basis of a new imaging modality, induced current electrical impedance tomography (EIT), is investigated, The ultimate aim of this technique is the reconstruction of conductivity distribution of the human body, from voltage measurements made between electrodes placed on the surface, when currents are i...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.293927

    authors: Gencer NG,Kuzuoglu M,Ider YZ

    更新日期:1994-01-01 00:00:00

  • Two iterative image restoration algorithms with applications to nuclear medicine.

    abstract::Two methods for recovering an image that has been degraded while being processed are presented. The restoration problem is formulated as a constrained optimization problem in which a measure of smoothness based on the second derivatives of the restored image is maximized subject to the constraint that noise energy is ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.126904

    authors: Charalambous C,Ghaddar FK,Kouris K

    更新日期:1992-01-01 00:00:00

  • On Bayesian image reconstruction from projections: uniform and nonuniform a priori source information.

    abstract::A method that incorporates a priori uniform or nonuniform source distribution probabilistic information and data fluctuations of a Poisson nature is presented. The source distributions are modeled in terms of a priori source probability density functions. Maximum a posteriori probability solutions, as determined by a ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.34711

    authors: Liang Z,Jaszczak R,Greer K

    更新日期:1989-01-01 00:00:00