Estimating kinetic parameter maps from dynamic contrast-enhanced MRI using spatial prior knowledge.

Abstract:

:Dynamic contrast-enhanced magnetic resonance (DCE-MR) imaging can be used to study microvascular structure in vivo by monitoring the abundance of an injected diffusible contrast agent over time. The resulting spatially resolved intensity-time curves are usually interpreted in terms of kinetic parameters obtained by fitting a pharmacokinetic model to the observed data. Least squares estimates of the highly nonlinear model parameters, however, can exhibit high variance and can be severely biased. As a remedy, we bring to bear spatial prior knowledge by means of a generalized Gaussian Markov random field (GGMRF). By using information from neighboring voxels and computing the maximum a posteriori solution for entire parameter maps at once, both bias and variance of the parameter estimates can be reduced thus leading to smaller root mean square error (RMSE). Since the number of variables gets very big for common image resolutions, sparse solvers have to be employed. To this end, we propose a generalized iterated conditional modes (ICM) algorithm operating on blocks instead of sites which is shown to converge considerably faster than the conventional ICM algorithm. Results on simulated DCE-MR images show a clear reduction of RMSE and variance as well as, in some cases, reduced estimation bias. The mean residual bias (MRB) is reduced on the simulated data as well as for all 37 patients of a prostate DCE-MRI dataset. Using the proposed algorithm, average computation times only increase by a factor of 1.18 (871 ms per voxel) for a Gaussian prior and 1.51 (1.12 s per voxel) for an edge-preserving prior compared to the single voxel approach (740 ms per voxel).

journal_name

IEEE Trans Med Imaging

authors

Kelm BM,Menze BH,Nix O,Zechmann CM,Hamprecht FA

doi

10.1109/TMI.2009.2019957

subject

Has Abstract

pub_date

2009-10-01 00:00:00

pages

1534-47

issue

10

eissn

0278-0062

issn

1558-254X

journal_volume

28

pub_type

杂志文章
  • Robust Unmixing of Dynamic Sequences Using Regions of Interest.

    abstract::In dynamic planar imaging, extraction of signals specific to structures is complicated by structures superposition. Due to overlapping, signals extraction with classic regions of interest (ROIs) methods suffers from inaccuracy, as extracted signals are a mixture of targeted signals. Partial volume effect raises the sa...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2017.2759661

    authors: Filippi M,Desvignes M,Moisan E

    更新日期:2018-01-01 00:00:00

  • Fast local trust region technique for diffusion tensor registration using exact reorientation and regularization.

    abstract::Diffusion tensor imaging is widely used in brain connectivity research. As more and more studies recruit large numbers of subjects, it is important to design registration methods which are not only theoretically rigorous, but also computationally efficient. However, the requirement of reorienting diffusion tensors com...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2013.2274051

    authors: Li J,Shi Y,Tran G,Dinov I,Wang DJ,Toga A

    更新日期:2014-05-01 00:00:00

  • PET Image Reconstruction Using Deep Image Prior.

    abstract::Recently, deep neural networks have been widely and successfully applied in computer vision tasks and have attracted growing interest in medical imaging. One barrier for the application of deep neural networks to medical imaging is the need for large amounts of prior training pairs, which is not always feasible in cli...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2018.2888491

    authors: Gong K,Catana C,Qi J,Li Q

    更新日期:2019-07-01 00:00:00

  • Video-Rate Ring-Array Ultrasound and Photoacoustic Tomography.

    abstract::Ultrasonography and photoacoustic tomography provide complementary contrasts in preclinical studies, disease diagnoses, and imaging-guided interventional procedures. Here, we present a video-rate (20 Hz) dual-modality ultrasound and photoacoustic tomographic platform that has a high resolution, rich contrasts, deep pe...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2020.3017815

    authors: Zhang Y,Wang L

    更新日期:2020-12-01 00:00:00

  • Quantitative ECT: Comparison of Recovery Coefficient and Linearity of Detector Response for Single Photon and Coincidence Detection (F-18, B+ 511 keV).

    abstract::The response characteristics of two tomographic systems were compared for imaging of positron emitters: a) a SPECT system with a 3/8 in crystal and 511 keV detector shielding, equipped with a specially designed 511 keV collimator, and b) a PET V system using coincidence detection. SPECT transverse plane resolution was...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.1986.4307776

    authors: Clarke LP,Cullom SJ,Kenny PJ,Saw CB,Silbiger ML

    更新日期:1986-01-01 00:00:00

  • Ultrasound imaging and identification of microcalcification clusters by correlation of scatter from multiple angles.

    abstract::Various types of malignant and benign breast tumors are associated with clusters of calcifications with grain sizes 0.1 to a few mm spread out over volumes of a few cc. A series of phantoms containing calcium carbonate grains embedded in a gelatin mixture were made and the ultrasound scattering patterns were measured ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.1984.4307668

    authors: Perez-Mendez V,Wiedenbeck P,Davis P,Tzeng CJ

    更新日期:1984-01-01 00:00:00

  • Tracking multiple particles in fluorescence time-lapse microscopy images via probabilistic data association.

    abstract::Tracking subcellular structures as well as viral structures displayed as 'particles' in fluorescence microscopy images yields quantitative information on the underlying dynamical processes. We have developed an approach for tracking multiple fluorescent particles based on probabilistic data association. The approach c...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2014.2359541

    authors: Godinez WJ,Rohr K

    更新日期:2015-02-01 00:00:00

  • Space-time segmentation using level set active contours applied to myocardial gated SPECT.

    abstract::This paper presents a new variational method for the segmentation of a moving object against a still background, over a sequence of [two-dimensional or three-dimensional (3-D)] image frames. The method is illustrated in application to myocardial gated single photon emission computed tomography (SPECT) data, and incorp...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.932748

    authors: Debreuve E,Barlaud M,Aubert G,Laurette I,Darcourt J

    更新日期:2001-07-01 00:00:00

  • Efficient fully 3-D iterative SPECT reconstruction with Monte Carlo-based scatter compensation.

    abstract::Quantitative accuracy of single photon emission computed tomography (SPECT) images is highly dependent on the photon scatter model used for image reconstruction. Monte Carlo simulation (MCS) is the most general method for detailed modeling of scatter, but to date, fully three-dimensional (3-D) MCS-based statistical SP...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2002.803130

    authors: Beekman FJ,de Jong HW,van Geloven S

    更新日期:2002-08-01 00:00:00

  • Multistage hybrid active appearance model matching: segmentation of left and right ventricles in cardiac MR images.

    abstract::A fully automated approach to segmentation of the left and right cardiac ventricles from magnetic resonance (MR) images is reported. A novel multistage hybrid appearance model methodology is presented in which a hybrid active shape model/active appearance model (AAM) stage helps avoid local minima of the matching func...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.925294

    authors: Mitchell SC,Lelieveldt BP,van der Geest RJ,Bosch HG,Reiber JH,Sonka M

    更新日期:2001-05-01 00:00:00

  • Displacement estimation with co-registered ultrasound for image guided neurosurgery: a quantitative in vivo porcine study.

    abstract::Brain shift during open cranial surgery presents a challenge for maintaining registration with image-guidance systems. Ultrasound (US) is a convenient intraoperative imaging modality that may be a useful tool in detecting tissue shift and updating preoperative images based on intraoperative measurements of brain defor...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2003.819293

    authors: Lunn KE,Paulsen KD,Roberts DW,Kennedy FE,Hartov A,West JD

    更新日期:2003-11-01 00:00:00

  • A maximum a posteriori probability expectation maximization algorithm for image reconstruction in emission tomography.

    abstract::The expectation maximization method for maximum likelihood image reconstruction in emission tomography, based on the Poisson distribution of the statistically independent components of the image and measurement vectors, is extended to a maximum aposteriori image reconstruction using a multivariate Gaussian a priori pr...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.1987.4307826

    authors: Levitan E,Herman GT

    更新日期:1987-01-01 00:00:00

  • Artificial Neural Network Enhanced Bayesian PET Image Reconstruction.

    abstract::In positron emission tomography (PET) image reconstruction, the Bayesian framework with various regularization terms has been implemented to constrain the radio tracer distribution. Varying the regularizing weight of a maximum a posteriori (MAP) algorithm specifies a lower bound of the tradeoff between variance and sp...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2018.2803681

    authors: Yang B,Ying L,Tang J

    更新日期:2018-06-01 00:00:00

  • Determination of optimal angiographic viewing angles: basic principles and evaluation study.

    abstract::Foreshortening of vessel segments in angiographic (biplane) projection images may cause misinterpretation of the extent and degree of coronary artery disease. The views in which the object of interest are visualized with minimum foreshortening are called optimal views. The authors present a complete approach to obtain...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.276141

    authors: Dumay AM,Reiber JC,Gerbrands JJ

    更新日期:1994-01-01 00:00:00

  • Feature extraction in carpal-bone analysis.

    abstract::Hand-bone analysis with image processing techniques using a digital radiograph can be used to assess skeletal age. The analysis consists of two steps: phalangeal and carpal bone analysis. The carpal bone analysis is discussed. First, the carpal bone region of interest (CROI) is defined using a standard thresholding te...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.222665

    authors: Pietka E,Kaabi L,Kuo ML,Huang HK

    更新日期:1993-01-01 00:00:00

  • SVD compression for magnetic resonance fingerprinting in the time domain.

    abstract::Magnetic resonance (MR) fingerprinting is a technique for acquiring and processing MR data that simultaneously provides quantitative maps of different tissue parameters through a pattern recognition algorithm. A predefined dictionary models the possible signal evolutions simulated using the Bloch equations with differ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2014.2337321

    authors: McGivney DF,Pierre E,Ma D,Jiang Y,Saybasili H,Gulani V,Griswold MA

    更新日期:2014-12-01 00:00:00

  • Improved Low-Count Quantitative PET Reconstruction With an Iterative Neural Network.

    abstract::Image reconstruction in low-count PET is particularly challenging because gammas from natural radioactivity in Lu-based crystals cause high random fractions that lower the measurement signal-to-noise-ratio (SNR). In model-based image reconstruction (MBIR), using more iterations of an unregularized method may increase ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2020.2998480

    authors: Lim H,Chun IY,Dewaraja YK,Fessler JA

    更新日期:2020-11-01 00:00:00

  • Numerical characterization of quasi-static ultrasound elastography for the detection of deep tissue injuries.

    abstract::Deep tissue injuries are subcutaneous regions of tissue breakdown associated with excessive mechanical pressure for extended period of time. These wounds are currently clinically undetectable in their early stages and result in severe burdens on not only the patients who suffer from them, but the health care system as...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2014.2313082

    authors: Hamaluik K,Moussa W,Ferguson-Pell M

    更新日期:2014-07-01 00:00:00

  • Anatomical model matching with fuzzy implicit surfaces for segmentation of thoracic volume scans.

    abstract::Many segmentation methods for thoracic volume data require manual input in the form of a seed point, initial contour, volume of interest etc. The aim of the work presented here is to further automate this segmentation initialization step. In this paper an anatomical modeling and matching method is proposed to coarsely...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.764893

    authors: Lelieveldt BP,van der Geest RJ,Rezaee MR,Bosch JG,Reiber JH

    更新日期:1999-03-01 00:00:00

  • Objective Detection of Eloquent Axonal Pathways to Minimize Postoperative Deficits in Pediatric Epilepsy Surgery using Diffusion Tractography and Convolutional Neural Networks.

    abstract::Convolutional neural networks (CNNs) have recently been used in biomedical imaging applications with great success. In this paper, we investigated the classi?cation performance of CNN models on diffusion weighted imaging (DWI) streamlines de?ned by functional MRI (fMRI) and electrical stimulation mapping (ESM). To lea...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2019.2902073

    authors: Xu H,Dong M,Lee MH,OrHara N,Asano E,Jeong JW

    更新日期:2019-02-27 00:00:00

  • Estimating the Accuracy Level Among Individual Detections in Clustered Microcalcifications.

    abstract::Computerized detection of clustered microcalcifications (MCs) in mammograms often suffers from the occurrence of false positives (FPs), which can vary greatly from case to case. We investigate how to apply statistical estimation to determine the number of FPs that are present in a detected MC lesion. First, we describ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2017.2654799

    authors: Sainz de Cea MV,Nishikawa RM,Yang Y

    更新日期:2017-05-01 00:00:00

  • Joint Optic Disc and Cup Segmentation Based on Multi-Label Deep Network and Polar Transformation.

    abstract::Glaucoma is a chronic eye disease that leads to irreversible vision loss. The cup to disc ratio (CDR) plays an important role in the screening and diagnosis of glaucoma. Thus, the accurate and automatic segmentation of optic disc (OD) and optic cup (OC) from fundus images is a fundamental task. Most existing methods s...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2018.2791488

    authors: Fu H,Cheng J,Xu Y,Wong DWK,Liu J,Cao X

    更新日期:2018-07-01 00:00:00

  • Using human and model performance to compare MRI reconstructions.

    abstract::Magnetic resonance imaging (MRI) reconstruction techniques are often validated with signal-to-noise ratio (SNR), contrast-to-noise ratio, and mean-to-standard-deviation ratio measured on example images. We present human and model observers as a novel approach to evaluating reconstructions for low-SNR magnetic resonanc...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2006.881374

    authors: Tisdall MD,Atkins MS

    更新日期:2006-11-01 00:00:00

  • Ovarian ultrasound image analysis: follicle segmentation.

    abstract::Ovarian ultrasound is an effective tool in infertility treatment. Repeated measurements of the size and shape of follicles over several days are the primary means of evaluation by physicians. Currently, follicle wall segmentation is achieved by manual tracing which is time consuming and susceptible to inter-operator v...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.746626

    authors: Krivanek A,Sonka M

    更新日期:1998-12-01 00:00:00

  • Anti-aliasing weighting functions for single-slice helical CT.

    abstract::Spatially variant longitudinal aliasing plagues most volumes reconstructed from single-slice helical computed tomography data, and its presence can degrade resolution and distort image structures. We have recently developed a Fourier-based approach to longitudinal interpolation in helical computed tomography that can,...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2002.803104

    authors: La Rivière PJ,Pan X

    更新日期:2002-08-01 00:00:00

  • Three-dimensional segmentation of fluid-associated abnormalities in retinal OCT: probability constrained graph-search-graph-cut.

    abstract::An automated method is reported for segmenting 3-D fluid-associated abnormalities in the retina, so-called symptomatic exudate-associated derangements (SEAD), from 3-D OCT retinal images of subjects suffering from exudative age-related macular degeneration. In the first stage of a two-stage approach, retinal layers ar...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2012.2191302

    authors: Chen X,Niemeijer M,Zhang L,Lee K,Abramoff MD,Sonka M

    更新日期:2012-08-01 00:00:00

  • Gaussian process models of dynamic PET for functional volume definition in radiation oncology.

    abstract::In routine oncologic positron emission tomography (PET), dynamic information is discarded by time-averaging the signal to produce static images of the "standardised uptake value" (SUV). Defining functional volumes of interest (VOIs) in terms of SUV is flawed, as values are affected by confounding factors and the chose...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2012.2193896

    authors: Shepherd T,Owenius R

    更新日期:2012-08-01 00:00:00

  • Automatic construction of parts+geometry models for initializing groupwise registration.

    abstract::Groupwise nonrigid image registration is a powerful tool to automatically establish correspondences across sets of images. Such correspondences are widely used for constructing statistical models of shape and appearance. As existing techniques usually treat registration as an optimization problem, a good initializatio...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2011.2169077

    authors: Zhang P,Cootes TF

    更新日期:2012-02-01 00:00:00

  • Use of needle track detection to quantify the displacement of stranded seeds following prostate brachytherapy.

    abstract::We aim to compute the movement of permanent stranded implant brachytherapy radioactive sources (seeds) in the prostate from the planned seed distribution to the intraoperative fluoroscopic distribution, and then to the postimplant computed tomography (CT) distribution. We present a novel approach to matching the seeds...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2011.2178254

    authors: Lobo JR,Moradi M,Chng N,Dehghan E,Morris WJ,Fichtinger G,Salcudean SE

    更新日期:2012-03-01 00:00:00

  • Fractal feature analysis and classification in medical imaging.

    abstract::Following B.B. Mandelbrot's fractal theory (1982), it was found that the fractal dimension could be obtained in medical images by the concept of fractional Brownian motion. An estimation concept for determination of the fractal dimension based upon the concept of fractional Brownian motion is discussed. Two applicatio...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.24861

    authors: Chen CC,Daponte JS,Fox MD

    更新日期:1989-01-01 00:00:00