Fast local trust region technique for diffusion tensor registration using exact reorientation and regularization.

Abstract:

:Diffusion tensor imaging is widely used in brain connectivity research. As more and more studies recruit large numbers of subjects, it is important to design registration methods which are not only theoretically rigorous, but also computationally efficient. However, the requirement of reorienting diffusion tensors complicates and considerably slows down registration procedures, due to the correlated impacts of registration forces at adjacent voxel locations. Based on the diffeomorphic Demons algorithm (Vercauteren , 2009), we propose a fast local trust region algorithm for handling inseparable registration forces for quadratic energy functions. The method guarantees that, at any time and at any voxel location, the velocity is always within its local trust region. This local regularization allows efficient calculation of the transformation update with numeric integration instead of completely solving a large linear system at every iteration. It is able to incorporate exact reorientation and regularization into the velocity optimization, and preserve the linear complexity of the diffeomorphic Demons algorithm. In an experiment with 84 diffusion tensor images involving both pair-wise and group-wise registrations, the proposed algorithm achieves better registration in comparison with other methods solving large linear systems (Yeo , 2009). At the same time, this algorithm reduces the computation time and memory demand tenfold.

journal_name

IEEE Trans Med Imaging

authors

Li J,Shi Y,Tran G,Dinov I,Wang DJ,Toga A

doi

10.1109/TMI.2013.2274051

subject

Has Abstract

pub_date

2014-05-01 00:00:00

pages

1005-22

issue

5

eissn

0278-0062

issn

1558-254X

journal_volume

33

pub_type

杂志文章
  • Volumetric texture segmentation by discriminant feature selection and multiresolution classification.

    abstract::In this paper, a multiresolution volumetric texture segmentation (M-VTS) algorithm is presented. The method extracts textural measurements from the Fourier domain of the data via subband filtering using an orientation pyramid (Wilson and Spann, 1988). A novel Bhattacharyya space, based on the Bhattacharyya distance, i...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2006.884637

    authors: Reyes Aldasoro CC,Bhalerao A

    更新日期:2007-01-01 00:00:00

  • Mobile Biplane X-Ray Imaging System for Measuring 3D Dynamic Joint Motion During Overground Gait.

    abstract::Most X-ray fluoroscopy systems are stationary and impose restrictions on the measurement of dynamic joint motion; for example, knee-joint kinematics during gait is usually measured with the subject ambulating on a treadmill. We developed a computer-controlled, mobile, biplane, X-ray fluoroscopy system to track human b...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2015.2473168

    authors: Guan S,Gray HA,Keynejad F,Pandy MG

    更新日期:2016-01-01 00:00:00

  • Point-based rigid-body registration using an unscented Kalman filter.

    abstract::We present and validate a novel registration algorithm mapping two data sets, generated from a rigid object, in the presence of Gaussian noise. The proposed method is based on the Unscented Kalman Filter (UKF) algorithm that is generally employed for analyzing nonlinear systems corrupted by additive Gaussian noise. Fi...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/tmi.2007.901984

    authors: Moghari MH,Abolmaesumi P

    更新日期:2007-12-01 00:00:00

  • A proposed taxonomy for nailfold capillaries based on their morphology.

    abstract::Certain diseases cause permanent changes to the shapes and densities of nailfold capillaries and, therefore, nailfold capillaroscopy is important as a tool for diagnosing and monitoring these diseases. The first aim of the project is to resolve differences in terminology that have developed over the years in previous ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.921482

    authors: Jones BF,Oral M,Morris CW,Ring EF

    更新日期:2001-04-01 00:00:00

  • Algebraic reconstruction for magnetic resonance imaging under B0 inhomogeneity.

    abstract::In magnetic resonance imaging, spatial localization is usually achieved using Fourier encoding which is realized by applying a magnetic field gradient along the dimension of interest to create a linear correspondence between the resonance frequency and spatial location following the Larmor equation. In the presence of...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.712126

    authors: Kadah YM,Hu X

    更新日期:1998-06-01 00:00:00

  • Including anatomical and functional information in MC simulation of PET and SPECT brain studies. Brain-VISET: a voxel-based iterative method.

    abstract::Monte Carlo (MC) simulation provides a flexible and robust framework to efficiently evaluate and optimize image processing methods in emission tomography. In this work we present Brain-VISET (Voxel-based Iterative Simulation for Emission Tomography), a method that aims to simulate realistic [ (99m) Tc]-SPECT and [ (18...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2014.2326041

    authors: Marti-Fuster B,Esteban O,Thielemans K,Setoain X,Santos A,Ros D,Pavia J

    更新日期:2014-10-01 00:00:00

  • A robust ultrashort TE (UTE) imaging method with corrected k-space trajectory by using parametric multiple function model of gradient waveform.

    abstract::Ultra-short TE (UTE) sequences with radial sampling make it possible to visualize tissues with very short T2 decay times. The UTE sequence acquires an echo signal from the central to the outer parts of k-space and is very sensitive to small trajectory errors. Therefore, k-space errors caused by imperfections in the gr...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2012.2226050

    authors: Takizawa M,Hanada H,Oka K,Takahashi T,Yamamoto E,Fujii M

    更新日期:2013-02-01 00:00:00

  • High-Permittivity Pad Design for Dielectric Shimming in Magnetic Resonance Imaging Using Projection-Based Model Reduction and a Nonlinear Optimization Scheme.

    abstract::Inhomogeneities in the transmit radio frequency magnetic field ( ) reduce the quality of magnetic resonance (MR) images. This quality can be improved by using high-permittivity pads that tailor the fields. The design of an optimal pad is application-specific and not straightforward and would therefore benefit from a s...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2018.2791179

    authors: van Gemert JHF,Brink WM,Webb AG,Remis RF

    更新日期:2018-04-01 00:00:00

  • Computation of the mid-sagittal plane in 3-D brain images.

    abstract::We present a new method to automatically compute, reorient, and recenter the mid-sagittal plane in anatomical and functional three-dimensional (3-D) brain images. This iterative approach is composed of two steps. At first, given an initial guess of the mid-sagittal plane (generally, the central plane of the image grid...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.993131

    authors: Prima S,Ourselin S,Ayache N

    更新日期:2002-02-01 00:00:00

  • Optimal rebinning of time-of-flight PET data.

    abstract::Time-of-flight (TOF) positron emission tomography (PET) scanners offer the potential for significantly improved signal-to-noise ratio (SNR) and lesion detectability in clinical PET. However, fully 3D TOF PET image reconstruction is a challenging task due to the huge data size. One solution to this problem is to rebin ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2011.2149537

    authors: Ahn S,Cho S,Li Q,Lin Y,Leahy RM

    更新日期:2011-10-01 00:00:00

  • Statistical Biomechanical Surface Registration: Application to MR-TRUS Fusion for Prostate Interventions.

    abstract::A common challenge when performing surface-based registration of images is ensuring that the surfaces accurately represent consistent anatomical boundaries. Image segmentation may be difficult in some regions due to either poor contrast, low slice resolution, or tissue ambiguities. To address this, we present a novel ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2015.2443978

    authors: Khallaghi S,Sánchez CA,Rasoulian A,Nouranian S,Romagnoli C,Abdi H,Chang SD,Black PC,Goldenberg L,Morris WJ,Spadinger I,Fenster A,Ward A,Fels S,Abolmaesumi P

    更新日期:2015-12-01 00:00:00

  • Compressed Sensing Doppler Ultrasound Reconstruction Using Block Sparse Bayesian Learning.

    abstract::In this paper we propose a framework for using duplex Doppler ultrasound systems. These type of systems need to interleave the acquisition and display of a B-mode image and of the pulsed Doppler spectrogram. In a recent study (Richy , 2013), we have shown that compressed sensing-based reconstruction of Doppler signal ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2015.2504240

    authors: Lorintiu O,Liebgott H,Friboulet D

    更新日期:2016-04-01 00:00:00

  • Flux-based anisotropic diffusion applied to enhancement of 3-D angiogram.

    abstract::We present a new approach to anisotropic diffusion based on a multidirectional diffusion flux. The diffusion flux is decomposed in an orthogonal basis, effectively enabling enhancement of contours as well as diffusion along the contours. To this end, we have selected a three-dimensional basis that depicts the directio...

    journal_title:IEEE transactions on medical imaging

    pub_type: 信件

    doi:10.1109/TMI.2002.806403

    authors: Krissian K

    更新日期:2002-11-01 00:00:00

  • A methodology for evaluation of boundary detection algorithms on medical images.

    abstract::Image segmentation is the partition of an image into a set of nonoverlapping regions whose union is the entire image. The image is decomposed into meaningful parts which are uniform with respect to certain characteristics, such as gray level or texture. In this paper, we propose a methodology for evaluating medical im...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.640755

    authors: Chalana V,Kim Y

    更新日期:1997-10-01 00:00:00

  • Quantification of MR brain images by mixture density and partial volume modeling.

    abstract::The problem of automatic quantification of brain tissue by utilizing single-valued (single echo) magnetic resonance imaging (MRI) brain scans is addressed. It is shown that this problem can be solved without classification or segmentation, a method that may be particularly useful in quantifying white matter lesions wh...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.241885

    authors: Santago P,Gage HD

    更新日期:1993-01-01 00:00:00

  • Efficient Compressed Sensing SENSE pMRI Reconstruction With Joint Sparsity Promotion.

    abstract::The theory and techniques of compressed sensing (CS) have shown their potential as a breakthrough in accelerating k-space data acquisition for parallel magnetic resonance imaging (pMRI). However, the performance of CS reconstruction models in pMRI has not been fully maximized, and CS recovery guarantees for pMRI are l...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2015.2474383

    authors: Chun IY,Adcock B,Talavage TM

    更新日期:2016-01-01 00:00:00

  • Multi-Task Deep Model With Margin Ranking Loss for Lung Nodule Analysis.

    abstract::Lung cancer is the leading cause of cancer deaths worldwide and early diagnosis of lung nodule is of great importance for therapeutic treatment and saving lives. Automated lung nodule analysis requires both accurate lung nodule benign-malignant classification and attribute score regression. However, this is quite chal...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2019.2934577

    authors: Liu L,Dou Q,Chen H,Qin J,Heng PA

    更新日期:2020-03-01 00:00:00

  • Establishment of an Automated Algorithm Utilizing Optical Coherence Tomography and Micro-Computed Tomography Imaging to Reconstruct the 3-D Deformed Stent Geometry.

    abstract::Percutaneous coronary intervention (PCI) is the prevalent treatment for coronary artery disease, with hundreds of thousands of stents implanted annually. Computational studies have demonstrated the role of biomechanics in the failure of vascular stents, but clinical studies is this area are limited by a lack of unders...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2018.2870714

    authors: Elliott MR,Kim D,Molony DS,Morris L,Samady H,Joshi S,Timmins LH

    更新日期:2019-03-01 00:00:00

  • Estimating average growth trajectories in shape-space using kernel smoothing.

    abstract::In this paper, we show how a dense surface point distribution model of the human face can be computed and demonstrate the usefulness of the high-dimensional shape-space for expressing the shape changes associated with growth and aging. We show how average growth trajectories for the human face can be computed in the a...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2003.814784

    authors: Hutton TJ,Buxton BF,Hammond P,Potts HW

    更新日期:2003-06-01 00:00:00

  • Fluorescence Diffusion in the Presence of Optically Clear Tissues in a Mouse Head Model.

    abstract::Diffuse Optical Tomography commonly neglects or assumes as insignificant the presence of optically clear regions in biological tissues, estimating their contribution as a small perturbation to light transport. The inaccuracy introduced by this practice is examined in detail in the context of a complete, based on reali...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2016.2646518

    authors: Ancora D,Zacharopoulos A,Ripoll J,Zacharakis G

    更新日期:2017-05-01 00:00:00

  • Progressive coding and transmission of digital diagnostic pictures.

    abstract::In radiology, as a result of the increased utilization of digital imaging modalities, such as computed tomography (CT) and magnetic resonance imaging (MRI), over a third of the images produced in a typical radiology department are currently in digital form, and this percentage is steadily increasing. Image compression...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.1986.4307750

    authors: Elnahas SE,Tzou KH,Cox JR,Hill RL,Jost R

    更新日期:1986-01-01 00:00:00

  • Unification of the inverse radon transform in odd and even dimensions.

    abstract::It is well known that the inverse radon transform exists in two forms for odd and even dimension functions, respectively. This note shows that these formulas become zero when the dimension requirement is violated, which results in a simple unified formula for the inverse radon transform of arbitrary dimensions. ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.476117

    authors: Liang ZP

    更新日期:1995-01-01 00:00:00

  • The problem of scatter correction in positron volume imaging.

    abstract::Thin, dense interslice septa have long been used to reduce the scattered radiation collected in positron emission tomography (PET). These septa prevent the acquisition of coincident gamma rays that are oblique to the scanning planes. Several volume imaging systems that acquire oblique rays have been built. The reasons...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.222675

    authors: Thompson CJ

    更新日期:1993-01-01 00:00:00

  • A geometric method for automatic extraction of sulcal fundi.

    abstract::Sulcal fundi are 3-D curves that lie in the depths of the cerebral cortex and, in addition to their intrinsic value in brain research, are often used as landmarks for downstream computations in brain imaging. In this paper, we present a geometric algorithm that automatically extracts the sulcal fundi from magnetic res...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2006.886810

    authors: Kao CY,Hofer M,Sapiro G,Stem J,Rehm K,Rottenberg DA

    更新日期:2007-04-01 00:00:00

  • Anti-aliasing weighting functions for single-slice helical CT.

    abstract::Spatially variant longitudinal aliasing plagues most volumes reconstructed from single-slice helical computed tomography data, and its presence can degrade resolution and distort image structures. We have recently developed a Fourier-based approach to longitudinal interpolation in helical computed tomography that can,...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2002.803104

    authors: La Rivière PJ,Pan X

    更新日期:2002-08-01 00:00:00

  • Resampling of data between arbitrary grids using convolution interpolation.

    abstract::For certain medical applications resampling of data is required. In magnetic resonance tomography (MRT) or computer tomography (CT), e.g., data may be sampled on nonrectilinear grids in the Fourier domain. For the image reconstruction a convolution-interpolation algorithm, often called gridding, can be applied for res...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.774166

    authors: Rasche V,Proksa R,Sinkus R,Börnert P,Eggers H

    更新日期:1999-05-01 00:00:00

  • Estimation and detection of myocardial tags in MR image without user-defined myocardial contours.

    abstract::Magnetic resonance (MR) tagging has been shown to be a useful technique for noninvasively measuring the deformation of an in vivo heart. An important step in analyzing tagged images is the identification of tag lines in each image of a cine sequence. Most existing tag identification algorithms require user defined myo...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.768842

    authors: Denney TS Jr

    更新日期:1999-04-01 00:00:00

  • Toward Electrical Impedance Tomography Coupled Ultrasound Imaging for Assessing Muscle Health.

    abstract::This paper establishes for the first time that a coupled ultrasound (US) and electrical impedance tomography (EIT) system can serve as a non-invasive, spatially localized approach to extract clinically relevant muscle properties. The US/EIT system represents a potential enhancement to electrical impedance myography (E...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2018.2886152

    authors: Murphy EK,Skinner J,Martucci M,Rutkove SB,Halter RJ

    更新日期:2019-06-01 00:00:00

  • Quantitative analysis of cardiac tissue including fibroblasts using three-dimensional confocal microscopy and image reconstruction: towards a basis for electrophysiological modeling.

    abstract::Electrophysiological modeling of cardiac tissue is commonly based on functional and structural properties measured in experiments. Our knowledge of these properties is incomplete, in particular their remodeling in disease. Here, we introduce a methodology for quantitative tissue characterization based on fluorescent l...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2013.2240693

    authors: Schwab BC,Seemann G,Lasher RA,Torres NS,Wulfers EM,Arp M,Carruth ED,Bridge JH,Sachse FB

    更新日期:2013-05-01 00:00:00

  • Topology-based kernels with application to inference problems in Alzheimer's disease.

    abstract::Alzheimer's disease (AD) research has recently witnessed a great deal of activity focused on developing new statistical learning tools for automated inference using imaging data. The workhorse for many of these techniques is the support vector machine (SVM) framework (or more generally kernel-based methods). Most of t...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2011.2147327

    authors: Pachauri D,Hinrichs C,Chung MK,Johnson SC,Singh V

    更新日期:2011-10-01 00:00:00