Accelerating parallel transmit array B1 mapping in high field MRI with slice undersampling and interpolation by kriging.

Abstract:

:Transmit arrays have been developed to mitigate the RF field inhomogeneity commonly observed in high field magnetic resonance imaging (MRI), typically above 3T. To this end, the knowledge of the RF complex-valued B1 transmit-sensitivities of each independent radiating element has become essential. This paper details a method to speed up a currently available B1-calibration method. The principle relies on slice undersampling, slice and channel interleaving and kriging, an interpolation method developed in geostatistics and applicable in many domains. It has been demonstrated that, under certain conditions, kriging gives the best estimator of a field in a region of interest. The resulting accelerated sequence allows mapping a complete set of eight volumetric field maps of the human head in about 1 min. For validation, the accuracy of kriging is first evaluated against a well-known interpolation technique based on Fourier transform as well as to a B1-maps interpolation method presented in the literature. This analysis is carried out on simulated and decimated experimental B1 maps. Finally, the accelerated sequence is compared to the standard sequence on a phantom and a volunteer. The new sequence provides B1 maps three times faster with a loss of accuracy limited potentially to about 5%.

journal_name

IEEE Trans Med Imaging

authors

Ferrand G,Luong M,Cloos MA,Amadon A,Wackernagel H

doi

10.1109/TMI.2014.2322440

subject

Has Abstract

pub_date

2014-08-01 00:00:00

pages

1726-34

issue

8

eissn

0278-0062

issn

1558-254X

journal_volume

33

pub_type

杂志文章
  • Automated segmentation of multiple sclerosis lesions by model outlier detection.

    abstract::This paper presents a fully automated algorithm for segmentation of multiple sclerosis (MS) lesions from multispectral magnetic resonance (MR) images. The method performs intensity-based tissue classification using a stochastic model for normal brain images and simultaneously detects MS lesions as outliers that are no...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.938237

    authors: Van Leemput K,Maes F,Vandermeulen D,Colchester A,Suetens P

    更新日期:2001-08-01 00:00:00

  • Fractal feature analysis and classification in medical imaging.

    abstract::Following B.B. Mandelbrot's fractal theory (1982), it was found that the fractal dimension could be obtained in medical images by the concept of fractional Brownian motion. An estimation concept for determination of the fractal dimension based upon the concept of fractional Brownian motion is discussed. Two applicatio...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.24861

    authors: Chen CC,Daponte JS,Fox MD

    更新日期:1989-01-01 00:00:00

  • Improved Low-Count Quantitative PET Reconstruction With an Iterative Neural Network.

    abstract::Image reconstruction in low-count PET is particularly challenging because gammas from natural radioactivity in Lu-based crystals cause high random fractions that lower the measurement signal-to-noise-ratio (SNR). In model-based image reconstruction (MBIR), using more iterations of an unregularized method may increase ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2020.2998480

    authors: Lim H,Chun IY,Dewaraja YK,Fessler JA

    更新日期:2020-11-01 00:00:00

  • Computer Aided Theragnosis Using Quantitative Ultrasound Spectroscopy and Maximum Mean Discrepancy in Locally Advanced Breast Cancer.

    abstract::A noninvasive computer-aided-theragnosis (CAT) system was developed for the early therapeutic cancer response assessment in patients with locally advanced breast cancer (LABC) treated with neoadjuvant chemotherapy. The proposed CAT system was based on multi-parametric quantitative ultrasound (QUS) spectroscopic method...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2015.2495246

    authors: Gangeh MJ,Tadayyon H,Sannachi L,Sadeghi-Naini A,Tran WT,Czarnota GJ

    更新日期:2016-03-01 00:00:00

  • Artificial Neural Network Enhanced Bayesian PET Image Reconstruction.

    abstract::In positron emission tomography (PET) image reconstruction, the Bayesian framework with various regularization terms has been implemented to constrain the radio tracer distribution. Varying the regularizing weight of a maximum a posteriori (MAP) algorithm specifies a lower bound of the tradeoff between variance and sp...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2018.2803681

    authors: Yang B,Ying L,Tang J

    更新日期:2018-06-01 00:00:00

  • Unification of the inverse radon transform in odd and even dimensions.

    abstract::It is well known that the inverse radon transform exists in two forms for odd and even dimension functions, respectively. This note shows that these formulas become zero when the dimension requirement is violated, which results in a simple unified formula for the inverse radon transform of arbitrary dimensions. ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.476117

    authors: Liang ZP

    更新日期:1995-01-01 00:00:00

  • Fast LV motion estimation using subspace approximation techniques.

    abstract::Cardiac motion estimation is very important in understanding cardiac dynamics and in noninvasive diagnosis of heart disease. Magnetic resonance (MR) imaging tagging is a technique for measuring heart deformations. In cardiac tagged MR images, a set of dark lines are noninvasively encoded within myocardial tissue provi...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.929616

    authors: Wang YP,Chen Y,Amini AA

    更新日期:2001-06-01 00:00:00

  • Time-frequency MEG-MUSIC algorithm.

    abstract::We propose a method that incorporates the time-frequency characteristics of neural sources into magnetoencephalographic (MEG) source estimation. The method is based on the multiple-signal-classification (MUSIC) algorithm and it calculates a time--frequency matrix in which diagonal and off-diagonal terms are the auto a...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.750262

    authors: Sekihara K,Nagarajan S,Poeppel D,Miyashita Y

    更新日期:1999-01-01 00:00:00

  • Renal Segmentation From 3D Ultrasound via Fuzzy Appearance Models and Patient-Specific Alpha Shapes.

    abstract::Ultrasound (US) imaging is the primary imaging modality for pediatric hydronephrosis, which manifests as the dilation of the renal collecting system (CS). In this paper, we present a new framework for the segmentation of renal structures, kidney and CS, from 3DUS scans. First, the kidney is segmented using an active s...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2016.2572641

    authors: Cerrolaza JJ,Safdar N,Biggs E,Jago J,Peters CA,Linguraru MG

    更新日期:2016-11-01 00:00:00

  • Feedback control of the nuclear magnetization state: modeling and control design.

    abstract::Magnetic resonance (MR) images are obtained by observing the fluctuations in nuclear magnetization produced by sequences of RF pulses and applied magnetic field gradients. The design of a pulse sequence is based on the expected response of the nuclear magnetization. Currently, all pulse sequence parameters are loaded ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.79471

    authors: Schiano JL,Magin RL,Wright SM

    更新日期:1991-01-01 00:00:00

  • Pubic arch detection in transrectal ultrasound guided prostate cancer therapy.

    abstract::New biopsy techniques, increased life expectancy, and prostate-specific antigen (PSA) screening have contributed to an increase in the reported incidence of prostate cancer. Among several treatment options available to the patients, transperineal prostate brachytherapy has emerged as a medically successful, cost-effec...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.736032

    authors: Pathak SD,Grimm PD,Chalana V,Kim Y

    更新日期:1998-10-01 00:00:00

  • Unwarping of unidirectionally distorted EPI images.

    abstract::Echo-planar imaging (EPI) is a fast nuclear magnetic resonance imaging (MRI) method. Unfortunately, local magnetic field inhomogeneities induced mainly by the subject's presence cause significant geometrical distortion, predominantly along the phase-encoding direction, which must be undone to allow for meaningful furt...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.836368

    authors: Kybic J,Thévenaz P,Nirkko A,Unser M

    更新日期:2000-02-01 00:00:00

  • Optimal rebinning of time-of-flight PET data.

    abstract::Time-of-flight (TOF) positron emission tomography (PET) scanners offer the potential for significantly improved signal-to-noise ratio (SNR) and lesion detectability in clinical PET. However, fully 3D TOF PET image reconstruction is a challenging task due to the huge data size. One solution to this problem is to rebin ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2011.2149537

    authors: Ahn S,Cho S,Li Q,Lin Y,Leahy RM

    更新日期:2011-10-01 00:00:00

  • Effect of detector weighting functions on the point spread function of high-resolution PET tomographs: a simulation study.

    abstract::The point spread function (PSF) of a ring PET tomograph is known to be spatially variant and difficult to obtain because it must be reconstructed from projections. A mathematical model was developed to simulate the data acquisition from a point source and to reconstruct the PSF, taking into account weighting functions...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.158942

    authors: Karuta B,Lecomte R

    更新日期:1992-01-01 00:00:00

  • MRF-based deformable registration and ventilation estimation of lung CT.

    abstract::Deformable image registration is an important tool in medical image analysis. In the case of lung computed tomography (CT) registration there are three major challenges: large motion of small features, sliding motions between organs, and changing image contrast due to compression. Recently, Markov random field (MRF)-b...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2013.2246577

    authors: Heinrich MP,Jenkinson M,Brady M,Schnabel JA

    更新日期:2013-07-01 00:00:00

  • A proposed taxonomy for nailfold capillaries based on their morphology.

    abstract::Certain diseases cause permanent changes to the shapes and densities of nailfold capillaries and, therefore, nailfold capillaroscopy is important as a tool for diagnosing and monitoring these diseases. The first aim of the project is to resolve differences in terminology that have developed over the years in previous ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.921482

    authors: Jones BF,Oral M,Morris CW,Ring EF

    更新日期:2001-04-01 00:00:00

  • Image guided personalization of reaction-diffusion type tumor growth models using modified anisotropic eikonal equations.

    abstract::Reaction-diffusion based tumor growth models have been widely used in the literature for modeling the growth of brain gliomas. Lately, recent models have started integrating medical images in their formulation. Including different tissue types, geometry of the brain and the directions of white matter fiber tracts impr...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2009.2026413

    authors: Konukoglu E,Clatz O,Menze BH,Stieltjes B,Weber MA,Mandonnet E,Delingette H,Ayache N

    更新日期:2010-01-01 00:00:00

  • Narrowband magnetic particle imaging.

    abstract::The magnetic particle imaging (MPI) method directly images the magnetization of super-paramagnetic iron oxide (SPIO) nanoparticles, which are contrast agents commonly used in magnetic resonance imaging (MRI). MPI, as originally envisioned, requires a high-bandwidth receiver coil and preamplifier, which are difficult t...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2009.2013849

    authors: Goodwill PW,Scott GC,Stang PP,Conolly SM

    更新日期:2009-08-01 00:00:00

  • Soft tissue differentiation using multiband signatures of high resolution ultrasonic transmission tomography.

    abstract::In this paper, we are interested in soft tissue differentiation by multiband images obtained from the High-Resolution Ultrasonic Transmission Tomography (HUTT) system using a spectral target detection method based on constrained energy minimization (CEM). We have developed a new tissue differentiation method (called "...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/tmi.2004.843179

    authors: Jeong JW,Kim TS,Shin DC,Do S,Singh M,Marmarelis VZ

    更新日期:2005-03-01 00:00:00

  • Multiobjective genetic optimization of diagnostic classifiers with implications for generating receiver operating characteristic curves.

    abstract::It is well understood that binary classifiers have two implicit objective functions (sensitivity and specificity) describing their performance. Traditional methods of classifier training attempt to combine these two objective functions (or two analogous class performance measures) into one so that conventional scalar ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.796281

    authors: Kupinski MA,Anastasio MA

    更新日期:1999-08-01 00:00:00

  • Solving the Bloch equation with periodic excitation using harmonic balancing: application to Rabi modulated excitation.

    abstract::In waveform design for magnetic resonance applications, periodic continuous-wave excitation offers potential advantages that remain largely unexplored because of a lack of understanding of the Bloch equation with periodic continuous-wave excitations. Using harmonic balancing techniques the steady state solutions of th...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2015.2423313

    authors: Tahayori B,Johnston LA,Layton KJ,Farrell PM,Mareels IM

    更新日期:2015-10-01 00:00:00

  • Improved watershed transform for medical image segmentation using prior information.

    abstract::The watershed transform has interesting properties that make it useful for many different image segmentation applications: it is simple and intuitive, can be parallelized, and always produces a complete division of the image. However, when applied to medical image analysis, it has important drawbacks (oversegmentation...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2004.824224

    authors: Grau V,Mewes AU,Alcañiz M,Kikinis R,Warfield SK

    更新日期:2004-04-01 00:00:00

  • FiloGen: A Model-Based Generator of Synthetic 3-D Time-Lapse Sequences of Single Motile Cells With Growing and Branching Filopodia.

    abstract::The existence of diverse image datasets accompanied by reference annotations is a crucial prerequisite for an objective benchmarking of bioimage analysis methods. Nevertheless, such a prerequisite is hard to satisfy for time lapse, multidimensional fluorescence microscopy image data, manual annotations of which are la...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2018.2845884

    authors: Sorokin DV,Peterlik I,Ulman V,Svoboda D,Necasova T,Morgaenko K,Eiselleova L,Tesarova L,Maska M

    更新日期:2018-12-01 00:00:00

  • Improved SPECT quantitation using fully three-dimensional iterative spatially variant scatter response compensation.

    abstract::The quality and quantitative accuracy of iteratively reconstructed SPECT images improves when better point spread function (PSF) models of the gamma camera are used during reconstruction. Here, inclusion in the PSF model of photon crosstalk between different slices caused by limited gamma camera resolution and scatter...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.511752

    authors: Beekman FJ,Kamphuis C,Viergever MA

    更新日期:1996-01-01 00:00:00

  • Single and multipinhole collimator design evaluation method for small animal SPECT.

    abstract::High-resolution functional imaging of small animals is often obtained by single pinhole SPECT with circular orbit acquisition. Multipinhole SPECT adds information due to its improved sampling, and can improve the trade-off between resolution and sensitivity. To evaluate different pinhole collimator designs an efficien...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2007.902802

    authors: Vunckx K,Beque D,Defrise M,Nuyts J

    更新日期:2008-01-01 00:00:00

  • A homogeneity correction method for magnetic resonance imaging with time-varying gradients.

    abstract::When time-varying gradients are used for imaging, the off-resonance behavior does not just cause geometric distortion as is the case with spin-warp imaging, but changes the shape of the impulse response and causes blurring. This effect is well known for projection reconstruction and spiral k-space scanning sequences. ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.108599

    authors: Noll DC,Meyer CH,Pauly JM,Nishimura DG,Macovski A

    更新日期:1991-01-01 00:00:00

  • Estimating average growth trajectories in shape-space using kernel smoothing.

    abstract::In this paper, we show how a dense surface point distribution model of the human face can be computed and demonstrate the usefulness of the high-dimensional shape-space for expressing the shape changes associated with growth and aging. We show how average growth trajectories for the human face can be computed in the a...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2003.814784

    authors: Hutton TJ,Buxton BF,Hammond P,Potts HW

    更新日期:2003-06-01 00:00:00

  • BICAV: a block-iterative parallel algorithm for sparse systems with pixel-related weighting.

    abstract::Component averaging (CAV) was recently introduced by Censor, Gordon, and Gordon as a new iterative parallel technique suitable for large and sparse unstructured systems of linear equations. Based on earlier work of Byrne and Censor, it uses diagonal weighting matrices, with pixel-related weights determined by the spar...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.959302

    authors: Censor Y,Gordon D,Gordon R

    更新日期:2001-10-01 00:00:00

  • Structure Prediction for Gland Segmentation With Hand-Crafted and Deep Convolutional Features.

    abstract::We present a novel method to segment instances of glandular structures from colon histopathology images. We use a structure learning approach which represents local spatial configurations of class labels, capturing structural information normally ignored by sliding-window methods. This allows us to reveal different sp...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2017.2750210

    authors: Manivannan S,Li W,Zhang J,Trucco E,McKenna SJ

    更新日期:2018-01-01 00:00:00

  • Prospective Respiration Detection in Magnetic Resonance Imaging by a Non-Interfering Noise Navigator.

    abstract::Passive monitoring of the thermal noise variances of the channels of a receive array was shown to reveal respiratory motion of the underlying anatomy, a so called "noise navigator". There is, however, an inevitable trade off between the accuracy and temporal resolution of the noise navigator due to its passive nature....

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2018.2808699

    authors: Navest RJM,Andreychenko A,Lagendijk JJW,van den Berg CAT

    更新日期:2018-08-01 00:00:00