A homogeneity correction method for magnetic resonance imaging with time-varying gradients.

Abstract:

:When time-varying gradients are used for imaging, the off-resonance behavior does not just cause geometric distortion as is the case with spin-warp imaging, but changes the shape of the impulse response and causes blurring. This effect is well known for projection reconstruction and spiral k-space scanning sequences. The authors introduce a reconstruction and homogeneity correction method to correct for the zeroth order effects of inhomogeneity using prior knowledge of the inhomogeneity. In this method, the data are segmented according to collection time, reconstructed using some fast, linear algorithm, correlated for inhomogeneity, and then superimposed to yield a homogeneity corrected image. This segmented method is compared to a conjugate phase reconstruction in terms of degree of correction and execution time. The authors apply this method to in vivo images using projection-reconstruction and spiral-scan sequences.

journal_name

IEEE Trans Med Imaging

authors

Noll DC,Meyer CH,Pauly JM,Nishimura DG,Macovski A

doi

10.1109/42.108599

subject

Has Abstract

pub_date

1991-01-01 00:00:00

pages

629-37

issue

4

eissn

0278-0062

issn

1558-254X

journal_volume

10

pub_type

杂志文章
  • Estimation of the hemodynamic response in event-related functional MRI: Bayesian networks as a framework for efficient Bayesian modeling and inference.

    abstract::A convenient way to analyze blood-oxygen-level-dependent functional magnetic resonance imaging data consists of modeling the whole brain as a stationary, linear system characterized by its transfer function: the hemodynamic response function (HRF). HRF estimation, though of the greatest interest, is still under invest...

    journal_title:IEEE transactions on medical imaging

    pub_type: 临床试验,杂志文章

    doi:10.1109/TMI.2004.831221

    authors: Marrelec G,Ciuciu P,Pélégrini-Issac M,Benali H

    更新日期:2004-08-01 00:00:00

  • Noise characterization of block-iterative reconstruction algorithms: II. Monte Carlo simulations.

    abstract::In Soares et al. (2000), the ensemble statistical properties of the rescaled block-iterative expectation-maximization (RBI-EM) reconstruction algorithm and rescaled block-iterative simultaneous multiplicative algebraic reconstruction technique (RBI-SMART) were derived. Included in this analysis were the special cases ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/tmi.2004.836876

    authors: Soares EJ,Glick SJ,Hoppin JW

    更新日期:2005-01-01 00:00:00

  • Automated detection of prostatic adenocarcinoma from high-resolution ex vivo MRI.

    abstract::Prostatic adenocarcinoma is the most commonly occurring cancer among men in the United States, second only to skin cancer. Currently, the only definitive method to ascertain the presence of prostatic cancer is by trans-rectal ultrasound (TRUS) directed biopsy. Owing to the poor image quality of ultrasound, the accurac...

    journal_title:IEEE transactions on medical imaging

    pub_type: 临床试验,杂志文章

    doi:10.1109/TMI.2005.859208

    authors: Madabhushi A,Feldman MD,Metaxas DN,Tomaszeweski J,Chute D

    更新日期:2005-12-01 00:00:00

  • Ovarian ultrasound image analysis: follicle segmentation.

    abstract::Ovarian ultrasound is an effective tool in infertility treatment. Repeated measurements of the size and shape of follicles over several days are the primary means of evaluation by physicians. Currently, follicle wall segmentation is achieved by manual tracing which is time consuming and susceptible to inter-operator v...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.746626

    authors: Krivanek A,Sonka M

    更新日期:1998-12-01 00:00:00

  • Patch-Based Output Space Adversarial Learning for Joint Optic Disc and Cup Segmentation.

    abstract::Glaucoma is a leading cause of irreversible blindness. Accurate segmentation of the optic disc (OD) and optic cup (OC) from fundus images is beneficial to glaucoma screening and diagnosis. Recently, convolutional neural networks demonstrate promising progress in the joint OD and OC segmentation. However, affected by t...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2019.2899910

    authors: Wang S,Yu L,Yang X,Fu CW,Heng PA

    更新日期:2019-11-01 00:00:00

  • Sufficient statistics as a generalization of binning in spectral X-ray imaging.

    abstract::It is well known that the energy dependence of X-ray attenuation can be used to characterize materials. Yet, even with energy discriminating photon counting X-ray detectors, it is still unclear how to best form energy dependent measurements for spectral imaging. Common ideas include binning photon counts based on thei...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2010.2061862

    authors: Wang AS,Pelc NJ

    更新日期:2011-01-01 00:00:00

  • Sparse patch-based label propagation for accurate prostate localization in CT images.

    abstract::In this paper, we propose a new prostate computed tomography (CT) segmentation method for image guided radiation therapy. The main contributions of our method lie in the following aspects. 1) Instead of using voxel intensity information alone, patch-based representation in the discriminative feature space with logisti...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2012.2230018

    authors: Liao S,Gao Y,Lian J,Shen D

    更新日期:2013-02-01 00:00:00

  • Multimodal registration and data fusion for cardiac resynchronization therapy optimization.

    abstract::Cardiac resynchronization therapy (CRT) has been shown to improve cardiovascular function in specific patients suffering from heart failure. This procedure still needs to be optimized to overcome the high rate of implanted patients that do not respond to this therapy. We propose in this work a better characterization ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2014.2311694

    authors: Tavard F,Simon A,Leclercq C,Donal E,Hernández AI,Garreau M

    更新日期:2014-06-01 00:00:00

  • Local phase tensor features for 3-D ultrasound to statistical shape+pose spine model registration.

    abstract::Most conventional spine interventions are performed under X-ray fluoroscopy guidance. In recent years, there has been a growing interest to develop nonionizing imaging alternatives to guide these procedures. Ultrasound guidance has emerged as a leading alternative. However, a challenging problem is automatic identific...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2014.2332571

    authors: Hacihaliloglu I,Rasoulian A,Rohling RN,Abolmaesumi P

    更新日期:2014-11-01 00:00:00

  • Robust online orientation correction for radiographs in PACS environments.

    abstract::In picture archiving and communications systems (PACS), images need to be displayed in standardized ways for radiologists' interpretations. However, for most radiographs acquired via computed radiography (CR), digital radiography (DR), or digitized films, the image orientation is undetermined because of the variations...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/tmi.2006.880677

    authors: Luo H,Luo J

    更新日期:2006-10-01 00:00:00

  • Robust simultaneous detection of coronary borders in complex images.

    abstract::Visual estimation of coronary obstruction severity from angiograms suffers from poor inter- and intraobserver reproducibility and is often inaccurate. In spite of the widely recognized limitations of visual analysis, automated methods have not found widespread clinical use, in part because they too frequently fail to ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.370412

    authors: Sonka M,Winniford MD,Collins SM

    更新日期:1995-01-01 00:00:00

  • An improved algorithm for 2-D translational motion artifact correction.

    abstract::The quality of magnetic resonance imaging systems has improved to the point that motion is a major limitation in many examinations. Translational motion in the imaging plane causes the phase of the data to be corrupted. An algorithm using computer post-processing is proposed to correct the phase of the data, and hence...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.108589

    authors: Medley M,Yan H,Rosenfeld D

    更新日期:1991-01-01 00:00:00

  • Spatial transformation of DWI data using non-negative sparse representation.

    abstract::This paper presents an algorithm to transform and reconstruct diffusion-weighted imaging (DWI) data for alignment of micro-structures in association with spatial transformations. The key idea is to decompose the diffusion signal profile, a function defined on a unit sphere, into a series of weighted diffusion basis fu...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2012.2204766

    authors: Yap PT,Shen D

    更新日期:2012-11-01 00:00:00

  • Development and validation of a Monte Carlo simulation of photon transport in an Anger camera.

    abstract::The geometric component of the point spread function (PSF) of a gamma camera collimator can be determined analytically, and the penetration component can be calculated readily by numerical ray-tracing. A Monte Carlo simulation of photon transport which includes collimator scatter is developed. The simulation was imple...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.61758

    authors: De Vries DJ,Moore SC,Zimmerman RE,Mueller SP,Friedland B,Lanza RC

    更新日期:1990-01-01 00:00:00

  • A versatile wavelet domain noise filtration technique for medical imaging.

    abstract::In this paper, we propose a robust wavelet domain method for noise filtering in medical images. The proposed method adapts itself to various types of image noise as well as to the preference of the medical expert; a single parameter can be used to balance the preservation of (expert-dependent) relevant details against...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2003.809588

    authors: Pizurica A,Philips W,Lemahieu I,Acheroy M

    更新日期:2003-03-01 00:00:00

  • Three-dimensional microwave breast imaging: dispersive dielectric properties estimation using patient-specific basis functions.

    abstract::Breast imaging via microwave tomography involves estimating the distribution of dielectric properties within the patient's breast on a discrete mesh. The number of unknowns in the discrete mesh can be very large for 3-D imaging, and this results in computational challenges. We propose a new approach where the discrete...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2008.2008959

    authors: Winters DW,Shea JD,Kosmas P,Van Veen BD,Hagness SC

    更新日期:2009-07-01 00:00:00

  • SNORE: spike noise removal and detection.

    abstract::A method for detection and removal of random spike noise in magnetic resonance (MR) raw data (k-space data) is described. This method would reduce or eliminate the corduroy-type and higher than usual level artifacts in MR images resulting from random spike noise in k-space data. The method described involves applying ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.276151

    authors: Foo TF,Grigsby NS,Mitchell JD,Slayman BE

    更新日期:1994-01-01 00:00:00

  • Interactive CT-video registration for the continuous guidance of bronchoscopy.

    abstract::Bronchoscopy is a major step in lung cancer staging. To perform bronchoscopy, the physician uses a procedure plan, derived from a patient's 3D computed-tomography (CT) chest scan, to navigate the bronchoscope through the lung airways. Unfortunately, physicians vary greatly in their ability to perform bronchoscopy. As ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2013.2252361

    authors: Merritt SA,Khare R,Bascom R,Higgins WE

    更新日期:2013-08-01 00:00:00

  • Wavelet analysis for brain-function imaging.

    abstract::The authors present a new algorithmic procedure for the analysis of brain images. This procedure is specifically designed to image the activity and functional organization of the brain. The authors' results are tested on data collected and previously analyzed with the technique known as in vivo optical imaging of intr...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.414621

    authors: Carmona RA,Hwang WL,Frostig RD

    更新日期:1995-01-01 00:00:00

  • Unsupervised Domain Adaptation from Axial to Short-Axis Multi-Slice Cardiac MR Images by Incorporating Pretrained Task Networks.

    abstract::Anisotropic multi-slice Cardiac Magnetic Resonance (CMR) Images are conventionally acquired in patient-specific short-axis (SAX) orientation. In specific cardiovascular diseases that affect right ventricular (RV) morphology, acquisitions in standard axial (AX) orientation are preferred by some investigators, due to po...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2021.3052972

    authors: Koehler S,Hussain T,Blair Z,Huffaker T,Ritzmann F,Tandon A,Pickardt T,Sarikouch S,Sarikouch S,Latus H,Greil G,Wolf I,Engelhardt S

    更新日期:2021-01-20 00:00:00

  • A Krasnoselskii-Mann Algorithm With an Improved EM Preconditioner for PET Image Reconstruction.

    abstract::This paper presents a preconditioned Krasnoselskii-Mann (KM) algorithm with an improved EM preconditioner (IEM-PKMA) for higher-order total variation (HOTV) regularized positron emission tomography (PET) image reconstruction. The PET reconstruction problem can be formulated as a three-term convex optimization model co...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2019.2898271

    authors: Lin Y,Schmidtlein CR,Li Q,Li S,Xu Y

    更新日期:2019-09-01 00:00:00

  • PORTR: Pre-operative and post-recurrence brain tumor registration.

    abstract::We propose a new method for deformable registration of pre-operative and post-recurrence brain MR scans of glioma patients. Performing this type of intra-subject registration is challenging as tumor, resection, recurrence, and edema cause large deformations, missing correspondences, and inconsistent intensity profiles...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2013.2293478

    authors: Kwon D,Niethammer M,Akbari H,Bilello M,Davatzikos C,Pohl KM

    更新日期:2014-03-01 00:00:00

  • Learning Domain Shift in Simulated and Clinical Data: Localizing the Origin of Ventricular Activation From 12-Lead Electrocardiograms.

    abstract::Building a data-driven model to localize the origin of ventricular activation from 12-lead electrocardiograms (ECG) requires addressing the challenge of large anatomical and physiological variations across individuals. The alternative of a patient-specific model is, however, difficult to implement in clinical practice...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2018.2880092

    authors: Alawad M,Wang L

    更新日期:2019-05-01 00:00:00

  • Characteristic quantities of microvascular structures in CLSM volume datasets.

    abstract::A method for fully automated morphological and topological quantification of microvascular structures in confocal laser scanning microscopy (CLSM) volume datasets is presented. Several characteristic morphological and topological quantities are calculated in a series of image-processing steps and can be used to compar...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2007.900379

    authors: Winter K,Metz LH,Kuska JP,Frerich B

    更新日期:2007-08-01 00:00:00

  • Segmentation of cardiac cine MR images for extraction of right and left ventricular chambers.

    abstract::A two-stage algorithm for extraction of the ventricular chambers (endocardial surfaces) in flow-enhanced magnetic resonance images is described. In the first stage, the approximate locations and sizes of the endocardial surfaces are determined by intensity thresholding. In the second stage, points on each approximated...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.370402

    authors: Goshtasby A,Turner DA

    更新日期:1995-01-01 00:00:00

  • 4-D Reconstruction With Respiratory Correction for Gated Myocardial Perfusion SPECT.

    abstract::Cardiac single photon emission computed tomography (SPECT) images are known to suffer from both cardiac and respiratory motion blur. In this paper, we investigate a 4-D reconstruction approach to suppress the effect of respiratory motion in gated cardiac SPECT imaging. In this approach, the sequence of cardiac gated i...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2017.2690819

    authors: Qi W,Yang Y,Song C,Wernick MN,Pretorius PH,King MA

    更新日期:2017-08-01 00:00:00

  • Ultrafast Ultrasound Imaging Using Combined Transmissions With Cross-Coherence-Based Reconstruction.

    abstract::Plane-wave-based ultrafast imaging has become the prevalent technique for non-conventional ultrasound imaging. The image quality, especially in terms of the suppression of artifacts, is generally compromised by reducing the number of transmissions for a higher frame rate. We hereby propose a new ultrafast imaging fram...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2017.2736423

    authors: Zhang Y,Guo Y,Lee WN

    更新日期:2018-02-01 00:00:00

  • CA-Net: Comprehensive Attention Convolutional Neural Networks for Explainable Medical Image Segmentation.

    abstract::Accurate medical image segmentation is essential for diagnosis and treatment planning of diseases. Convolutional Neural Networks (CNNs) have achieved state-of-the-art performance for automatic medical image segmentation. However, they are still challenged by complicated conditions where the segmentation target has lar...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2020.3035253

    authors: Gu R,Wang G,Song T,Huang R,Aertsen M,Deprest J,Ourselin S,Vercauteren T,Zhang S

    更新日期:2020-11-02 00:00:00

  • Classifying mammographic lesions using computerized image analysis.

    abstract::The classification of 3 common breast lesions, fibroadenomas, cysts, and cancers, was achieved using computerized image analysis of tumor shape in conjunction with patient age. The process involved the digitization of 69 mammographic images using a video camera and a commercial frame grabber on a PC-based computer sys...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.251116

    authors: Kilday J,Palmieri F,Fox MD

    更新日期:1993-01-01 00:00:00

  • Block-iterative Fisher scoring algorithms for maximum penalized likelihood image reconstruction in emission tomography.

    abstract::This paper introduces and evaluates a block-iterative Fisher scoring (BFS) algorithm. The algorithm provides regularized estimation in tomographic models of projection data with Poisson variability. Regularization is achieved by penalized likelihood with a general quadratic penalty. Local convergence of the block-iter...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2008.918355

    authors: Ma J,Hudson M

    更新日期:2008-08-01 00:00:00