Feedback control of the nuclear magnetization state: modeling and control design.

Abstract:

:Magnetic resonance (MR) images are obtained by observing the fluctuations in nuclear magnetization produced by sequences of RF pulses and applied magnetic field gradients. The design of a pulse sequence is based on the expected response of the nuclear magnetization. Currently, all pulse sequence parameters are loaded into the pulse programmer before the start of the sequence and remain unchanged until the completion of the sequence. A fundamentally different approach is considered, whereby the sequence parameters are adjusted between successive RF excitation pulses. In this manner, the nuclear magnetization is regulated to a desired state by using measurements of the magnetization to adjust the amplitude and duration of the RF pulses. Feedback control of the nuclear magnetization state may be advantageous in certain types of MR experiments, for example those requiring a repeated spin-echo or gated MR image acquisition. As a first step in developing this approach a simple scheme for regulating the angle between the bulk magnetization and the axis applied static magnetic field is presented. The behavior of the closed-loop system is explored using computer simulations.

journal_name

IEEE Trans Med Imaging

authors

Schiano JL,Magin RL,Wright SM

doi

10.1109/42.79471

subject

Has Abstract

pub_date

1991-01-01 00:00:00

pages

138-47

issue

2

eissn

0278-0062

issn

1558-254X

journal_volume

10

pub_type

杂志文章
  • Tomographic fluorescence imaging in tissue phantoms: a novel reconstruction algorithm and imaging geometry.

    abstract::A novel image reconstruction algorithm has been developed and demonstrated for fluorescence-enhanced frequency-domain photon migration (FDPM) tomography from measurements of area illumination with modulated excitation light and area collection of emitted fluorescence light using a gain modulated image-intensified char...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/tmi.2004.839359

    authors: Roy R,Thompson AB,Godavarty A,Sevick-Muraca EM

    更新日期:2005-02-01 00:00:00

  • Quantitative analysis of cardiac tissue including fibroblasts using three-dimensional confocal microscopy and image reconstruction: towards a basis for electrophysiological modeling.

    abstract::Electrophysiological modeling of cardiac tissue is commonly based on functional and structural properties measured in experiments. Our knowledge of these properties is incomplete, in particular their remodeling in disease. Here, we introduce a methodology for quantitative tissue characterization based on fluorescent l...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2013.2240693

    authors: Schwab BC,Seemann G,Lasher RA,Torres NS,Wulfers EM,Arp M,Carruth ED,Bridge JH,Sachse FB

    更新日期:2013-05-01 00:00:00

  • EMS-Net: A Deep Learning Method for Autodetecting Epileptic Magnetoencephalography Spikes.

    abstract::Epilepsy is a neurological disorder characterized by sudden and unpredictable epileptic seizures, which incurs significant negative impacts on patients' physical, psychological and social health. A practical approach to assist with the clinical assessment and treatment planning for patients is to process magnetoenceph...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2019.2958699

    authors: Zheng L,Liao P,Luo S,Sheng J,Teng P,Luan G,Gao JH

    更新日期:2020-06-01 00:00:00

  • Super Wide-Field Photoacoustic Microscopy of Animals and Humans In Vivo.

    abstract::Acoustic-resolution photoacoustic micro-scopy (AR-PAM) is an emerging biomedical imaging modality that combines superior optical sensitivity and fine ultrasonic resolution in an optical quasi-diffusive regime (~1-3 mm in tissues). AR-PAM has been explored for anatomical, functional, and molecular information in biolog...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2019.2938518

    authors: Baik JW,Kim JY,Cho S,Choi S,Kim J,Kim C

    更新日期:2020-04-01 00:00:00

  • MDM-PCCT: Multiple Dynamic Modulations for High-Performance Spectral PCCT Imaging.

    abstract::Photon counting computed tomography (PCCT) has the ability to identify individual photons, resulting in quantitative material identification. Meanwhile, several technical challenges still exist in current PCCT imaging systems, including increased noise and suboptimal bin selection. These nonideal effects can substanti...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2020.3001616

    authors: Li D,Zeng D,Li S,Ge Y,Bian Z,Huang J,Ma J

    更新日期:2020-11-01 00:00:00

  • Intrathoracic airway trees: segmentation and airway morphology analysis from low-dose CT scans.

    abstract::The segmentation of the human airway tree from volumetric computed tomography (CT) images builds an important step for many clinical applications and for physiological studies. Previously proposed algorithms suffer from one or several problems: leaking into the surrounding lung parenchyma, the need for the user to man...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2005.857654

    authors: Tschirren J,Hoffman EA,McLennan G,Sonka M

    更新日期:2005-12-01 00:00:00

  • Joint Optic Disc and Cup Segmentation Based on Multi-Label Deep Network and Polar Transformation.

    abstract::Glaucoma is a chronic eye disease that leads to irreversible vision loss. The cup to disc ratio (CDR) plays an important role in the screening and diagnosis of glaucoma. Thus, the accurate and automatic segmentation of optic disc (OD) and optic cup (OC) from fundus images is a fundamental task. Most existing methods s...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2018.2791488

    authors: Fu H,Cheng J,Xu Y,Wong DWK,Liu J,Cao X

    更新日期:2018-07-01 00:00:00

  • Anti-aliased three-dimensional cone-beam reconstruction of low-contrast objects with algebraic methods.

    abstract::This paper examines the use of the algebraic reconstruction technique (ART) and related techniques to reconstruct 3-D objects from a relatively sparse set of cone-beam projections. Although ART has been widely used for cone-beam reconstruction of high-contrast objects, e.g., in computed angiography, the work presented...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.781017

    authors: Mueller K,Yagel R,Wheller JJ

    更新日期:1999-06-01 00:00:00

  • Automated characterization of breast lesions imaged with an ultrafast DCE-MR protocol.

    abstract::Dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) of the breast has become an invaluable tool in the clinical work-up of patients suspected of having breast carcinoma. The purpose of this study is to introduce novel features extracted from the kinetics of contrast agent uptake imaged by a short (100 s) vi...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2013.2281984

    authors: Platel B,Mus R,Welte T,Karssemeijer N,Mann R

    更新日期:2014-02-01 00:00:00

  • Automatic Segmentation and Quantification of White and Brown Adipose Tissues from PET/CT Scans.

    abstract::In this paper, we investigate the automatic detection of white and brown adipose tissues using Positron Emission Tomography/Computed Tomography (PET/CT) scans, and develop methods for the quantification of these tissues at the whole-body and body-region levels. We propose a patient-specific automatic adiposity analysi...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2016.2636188

    authors: Hussein S,Green A,Watane A,Reiter D,Chen X,Papadakis GZ,Wood B,Cypess A,Osman M,Bagci U

    更新日期:2017-03-01 00:00:00

  • Stopping Rule for the MLE Algorithm Based on Statistical Hypothesis Testing.

    abstract::It is known that when the maximum likelihood estimator (MLE) algorithm passes a certain point, it produces images that begin to deteriorate. We propose a quantitative criterion with a simple probabilistic interpretation that allows the user to stop the algorithm just before this effect begins. The MLE algorithm search...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.1987.4307849

    authors: Veklerov E,Llacer J

    更新日期:1987-01-01 00:00:00

  • Separation of Metabolites and Macromolecules for Short-TE 1H-MRSI Using Learned Component-Specific Representations.

    abstract::Short-echo-time (TE) proton magnetic resonance spectroscopic imaging (MRSI) allows for simultaneously mapping a number of molecules in the brain, and has been recognized as an important tool for studying in vivo biochemistry in various neuroscience and disease applications. However, separation of the metabolite and ma...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2020.3048933

    authors: Li Y,Wang Z,Sun R,Lam F

    更新日期:2021-01-04 00:00:00

  • Point-based rigid-body registration using an unscented Kalman filter.

    abstract::We present and validate a novel registration algorithm mapping two data sets, generated from a rigid object, in the presence of Gaussian noise. The proposed method is based on the Unscented Kalman Filter (UKF) algorithm that is generally employed for analyzing nonlinear systems corrupted by additive Gaussian noise. Fi...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/tmi.2007.901984

    authors: Moghari MH,Abolmaesumi P

    更新日期:2007-12-01 00:00:00

  • Dynamic PET reconstruction using wavelet regularization with adapted basis functions.

    abstract::Tomographic reconstruction from positron emission tomography (PET) data is an ill-posed problem that requires regularization. An attractive approach is to impose an l(1) -regularization constraint, which favors sparse solutions in the wavelet domain. This can be achieved quite efficiently thanks to the iterative algor...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2008.923698

    authors: Verhaeghe J,Van de Ville D,Khalidov I,D'Asseler Y,Lemahieu I,Unser M

    更新日期:2008-01-01 00:00:00

  • Automated abdominal multi-organ segmentation with subject-specific atlas generation.

    abstract::A robust automated segmentation of abdominal organs can be crucial for computer aided diagnosis and laparoscopic surgery assistance. Many existing methods are specialized to the segmentation of individual organs and struggle to deal with the variability of the shape and position of abdominal organs. We present a gener...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2013.2265805

    authors: Wolz R,Chu C,Misawa K,Fujiwara M,Mori K,Rueckert D

    更新日期:2013-09-01 00:00:00

  • Statistical distributions of DCT coefficients and their application to an interframe compression algorithm for 3-D medical images.

    abstract::Displacement estimated interframe (DEI) coding, a coding scheme for 3-D medical image data sets such as X-ray computed tomography (CT) or magnetic resonance (MR) images, is presented. To take advantage of the correlation between contiguous slices, a displacement-compensated difference image based on the previous image...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.241875

    authors: Lee H,Kim Y,Rowberg AH,Riskin EA

    更新日期:1993-01-01 00:00:00

  • The effect of image distortion on 3-D reconstruction of coronary bypass grafts from angiographic views.

    abstract::Three-dimensional (3-D) reconstructions of coronary bypass grafts performed from X-ray angiographic images may become increasingly important for the investigation of damaging mechanical stresses imposed to these vessels by the cyclic movement of the heart. Contrary to what we had experienced with coronary arteries, ap...

    journal_title:IEEE transactions on medical imaging

    pub_type: 信件

    doi:10.1109/42.875203

    authors: Dorsaz PA,Dorsaz L,Doriot PA

    更新日期:2000-07-01 00:00:00

  • A characterization of the geometric architecture of the peritalar joint complex via MRI: an aid to the classification of foot type.

    abstract::The purpose of this work is to study the architecture of the rearfoot using in vivo MR image data. Each data set used in this study is made of sixty sagittal slices of the foot acquired in a 1.5-T commercial GE MR system. We use the live-wire method to delineate boundaries and form the surfaces of the bones. In the fi...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.802753

    authors: Stindel E,Udupa JK,Hirsch BE,Odhner D

    更新日期:1999-09-01 00:00:00

  • Edge detection in medical images using a genetic algorithm.

    abstract::An algorithm is developed that detects well-localized, unfragmented, thin edges in medical images based on optimization of edge configurations using a genetic algorithm (GA). Several enhancements were added to improve the performance of the algorithm over a traditional GA. The edge map is split into connected subregio...

    journal_title:IEEE transactions on medical imaging

    pub_type: 信件

    doi:10.1109/42.712136

    authors: Gudmundsson M,El-Kwae EA,Kabuka MR

    更新日期:1998-06-01 00:00:00

  • Augmented Likelihood Image Reconstruction.

    abstract::The presence of high-density objects remains an open problem in medical CT imaging. Data of projections passing through objects of high density, such as metal implants, are dominated by noise and are highly affected by beam hardening and scatter. Reconstructed images become less diagnostically conclusive because of pr...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2015.2459764

    authors: Stille M,Kleine M,Hägele J,Barkhausen J,Buzug TM

    更新日期:2016-01-01 00:00:00

  • Increased spatial resolution in transillumination using collimated light.

    abstract::In traditional transillumination of the breast (diaphanography), the abundance of diffuse light resulting from the use of extended noncollimated sources reduces the visibility of deep seated lesions. A prototype scanning imaging system has been developed to investigate the effectiveness of thin collimated light beams ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.251126

    authors: Wist AO,Fatouros PP,Herr SL

    更新日期:1993-01-01 00:00:00

  • A geometric method for automatic extraction of sulcal fundi.

    abstract::Sulcal fundi are 3-D curves that lie in the depths of the cerebral cortex and, in addition to their intrinsic value in brain research, are often used as landmarks for downstream computations in brain imaging. In this paper, we present a geometric algorithm that automatically extracts the sulcal fundi from magnetic res...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2006.886810

    authors: Kao CY,Hofer M,Sapiro G,Stem J,Rehm K,Rottenberg DA

    更新日期:2007-04-01 00:00:00

  • Reconstruction from Sparsely Sampled Data by ART with Interpolated Rays.

    abstract::After a brief discussion of the algebraic reconstruction techniques (ART), we introduce the attenuation problem in positron emission tomography (PET). We anticipate that a generalization of ART, the so-called cyclic subgradient projection (CSP) method, may be useful for solving this problem. This, however, has not bee...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.1982.4307567

    authors: Kouris K,Tuy H,Lent A,Herman GT,Lewitt RM

    更新日期:1982-01-01 00:00:00

  • Image Registration Based on Low Rank Matrix: Rank-Regularized SSD.

    abstract::Similarity measure is a main core of image registration algorithms. Spatially varying intensity distortion is an important challenge, which affects the performance of similarity measures. Correlation among the pixels is the main characteristic of this distortion. Similarity measures such as sum-of-squared-differences ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2017.2744663

    authors: Ghaffari A,Fatemizadeh E

    更新日期:2018-01-01 00:00:00

  • Video-Rate Ring-Array Ultrasound and Photoacoustic Tomography.

    abstract::Ultrasonography and photoacoustic tomography provide complementary contrasts in preclinical studies, disease diagnoses, and imaging-guided interventional procedures. Here, we present a video-rate (20 Hz) dual-modality ultrasound and photoacoustic tomographic platform that has a high resolution, rich contrasts, deep pe...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2020.3017815

    authors: Zhang Y,Wang L

    更新日期:2020-12-01 00:00:00

  • Accelerated iterative transmission CT reconstruction using an ordered subsets convex algorithm.

    abstract::Iterative maximum likelihood (ML) transmission computed tomography algorithms have distinct advantages over Fourier-based reconstruction, but unfortunately require increased computation time. The convex algorithm [1] is a relatively fast iterative ML algorithm but it is nevertheless too slow for many applications. The...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.746730

    authors: Kamphuis C,Beekman FJ

    更新日期:1998-12-01 00:00:00

  • Segmentation of rodent whole-body dynamic PET images: an unsupervised method based on voxel dynamics.

    abstract::Positron emission tomography (PET) is a useful tool for pharmacokinetics studies in rodents during the preclinical phase of drug and tracer development. However, rodent organs are small as compared to the scanner's intrinsic resolution and are affected by physiological movements. We present a new method for the segmen...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2007.905106

    authors: Maroy R,Boisgard R,Comtat C,Frouin V,Cathier P,Duchesnay E,Dollé F,Nielsen PE,Trébossen R,Tavitian B

    更新日期:2008-03-01 00:00:00

  • Spatially adaptive mixture modeling for analysis of FMRI time series.

    abstract::Within-subject analysis in fMRI essentially addresses two problems, the detection of brain regions eliciting evoked activity and the estimation of the underlying dynamics. In Makni et aL, 2005 and Makni et aL, 2008, a detection-estimation framework has been proposed to tackle these problems jointly, since they are con...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2010.2042064

    authors: Vincent T,Risser L,Ciuciu P

    更新日期:2010-04-01 00:00:00

  • A new algorithm for border description of polarized light surface microscopic images of pigmented skin lesions.

    abstract::The aim of this study was to provide mathematical descriptors for the border of pigmented skin lesion images and to assess their efficacy for distinction among different lesion groups. New descriptors such as lesion slope and lesion slope regularity are introduced and mathematically defined. A new algorithm based on t...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2003.815901

    authors: Grana C,Pellacani G,Cucchiara R,Seidenari S

    更新日期:2003-08-01 00:00:00

  • Direct Parametric Reconstruction Using Anatomical Regularization for Simultaneous PET/MRI Data.

    abstract::Pharmacokinetic analysis of dynamic positron emission tomography (PET) imaging data maps the measured time activity curves to a set of model-specific pharmacokinetic parameters. Voxel-based parameter estimation via curve fitting is conventionally performed indirectly on a sequence of independently reconstructed PET im...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2015.2427777

    authors: Loeb R,Navab N,Ziegler SI

    更新日期:2015-11-01 00:00:00