Abstract:
:Tomographic reconstruction from positron emission tomography (PET) data is an ill-posed problem that requires regularization. An attractive approach is to impose an l(1) -regularization constraint, which favors sparse solutions in the wavelet domain. This can be achieved quite efficiently thanks to the iterative algorithm developed by Daubechies et al., 2004. In this paper, we apply this technique and extend it for the reconstruction of dynamic (spatio-temporal) PET data. Moreover, instead of using classical wavelets in the temporal dimension, we introduce exponential-spline wavelets (E-spline wavelets) that are specially tailored to model time activity curves (TACs) in PET. We show that the exponential-spline wavelets naturally arise from the compartmental description of the dynamics of the tracer distribution. We address the issue of the selection of the "optimal" E-spline parameters (poles and zeros) and we investigate their effect on reconstruction quality. We demonstrate the usefulness of spatio-temporal regularization and the superior performance of E-spline wavelets over conventional Battle-LemariE wavelets in a series of experiments: the 1-D fitting of TACs, and the tomographic reconstruction of both simulated and clinical data. We find that the E-spline wavelets outperform the conventional wavelets in terms of the reconstructed signal-to-noise ratio (SNR) and the sparsity of the wavelet coefficients. Based on our simulations, we conclude that replacing the conventional wavelets with E-spline wavelets leads to equal reconstruction quality for a 40% reduction of detected coincidences, meaning an improved image quality for the same number of counts or equivalently a reduced exposure to the patient for the same image quality.
journal_name
IEEE Trans Med Imagingjournal_title
IEEE transactions on medical imagingauthors
Verhaeghe J,Van de Ville D,Khalidov I,D'Asseler Y,Lemahieu I,Unser Mdoi
10.1109/TMI.2008.923698subject
Has Abstractpub_date
2008-01-01 00:00:00pages
943-59issue
7eissn
0278-0062issn
1558-254Xjournal_volume
27pub_type
杂志文章abstract::Synthetic phased array (SPA) beamforming with Hadamard coding and aperture weighting is an optimal option for real-time volumetric imaging with a ring array, a particularly attractive geometry in intracardiac and intravascular applications. However, the imaging frame rate of this method is limited by the immense compu...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2013.2253117
更新日期:2013-07-01 00:00:00
abstract::Magnetic resonance (MR) fingerprinting is a technique for acquiring and processing MR data that simultaneously provides quantitative maps of different tissue parameters through a pattern recognition algorithm. A predefined dictionary models the possible signal evolutions simulated using the Bloch equations with differ...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2014.2337321
更新日期:2014-12-01 00:00:00
abstract::In this paper, we propose the use of multiscale amplitude-modulation-frequency-modulation (AM-FM) methods for discriminating between normal and pathological retinal images. The method presented in this paper is tested using standard images from the early treatment diabetic retinopathy study. We use 120 regions of 40 x...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2009.2037146
更新日期:2010-02-01 00:00:00
abstract::Accurate gain control of PET detectors is a prerequisite for quantitative accuracy. A shift in the 511 keV peak position can lead to errors in scatter correction, degrading quantitation. The PET detectors in a PET/MR scanner are subject to thermal transients due to eddy currents induced during gradient-intensive MRI s...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2020.3022321
更新日期:2021-01-01 00:00:00
abstract::A novel image reconstruction algorithm has been developed and demonstrated for fluorescence-enhanced frequency-domain photon migration (FDPM) tomography from measurements of area illumination with modulated excitation light and area collection of emitted fluorescence light using a gain modulated image-intensified char...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/tmi.2004.839359
更新日期:2005-02-01 00:00:00
abstract::The authors describe a technique to reduce truncation artifacts in chemical shift images taken for in vivo magnetic resonance spectroscopy by using boundary information available from anatomic images. In this approach, high spatial frequency components are extrapolated from the observed data by making use of the bound...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.97578
更新日期:1991-01-01 00:00:00
abstract::Look-up tables (LUTs) are a common method for increasing the speed of many algorithms. Their use can be extended to the reconstruction of nonuniformly sampled k-space data using either a discrete Fourier transform (DFT) algorithm or a convolution-based gridding algorithm. A table for the DFT would be precalculated arr...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.918471
更新日期:2001-03-01 00:00:00
abstract::Microwave radar imaging is promising as a complementary medical imaging modality. However, the unique nature of the images means interpretation can be difficult. As a result, it is important to understand the sources of image differences, and how much variability is inherent in the imaging system itself. To address th...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2018.2806878
更新日期:2018-08-01 00:00:00
abstract::An iterative algorithm is introduced which can compute and subtract the scatter bias. It is assumed that the scatter-free image is spatially bounded and anything outside the boundary is the result of recorded scattered photons. This information and the fact that the scatter distribution does not have appreciable high-...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.20362
更新日期:1989-01-01 00:00:00
abstract::A new graph-based approach for segmentation of luminal and external elastic lamina (EEL) surface of coronary vessels in gated 20 MHz intravascular ultrasound (IVUS) image sequences (volumes) is presented. The approach consists of a fully automated segmentation stage ("new automated" or NA) and a user-guided computer-a...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2013.2260763
更新日期:2013-08-01 00:00:00
abstract::We present a novel method to segment instances of glandular structures from colon histopathology images. We use a structure learning approach which represents local spatial configurations of class labels, capturing structural information normally ignored by sliding-window methods. This allows us to reveal different sp...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2017.2750210
更新日期:2018-01-01 00:00:00
abstract::An algorithm is developed for electrical impedance tomography (EIT) of finite cylinders with general cross-sectional boundaries and translationally uniform conductivity distributions. The electrodes for data collection are assumed to be placed around a cross-sectional plane; therefore, the axial variation of the bound...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.52982
更新日期:1990-01-01 00:00:00
abstract::Bronchoscopy is a major step in lung cancer staging. To perform bronchoscopy, the physician uses a procedure plan, derived from a patient's 3D computed-tomography (CT) chest scan, to navigate the bronchoscope through the lung airways. Unfortunately, physicians vary greatly in their ability to perform bronchoscopy. As ...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2013.2252361
更新日期:2013-08-01 00:00:00
abstract::A common challenge when performing surface-based registration of images is ensuring that the surfaces accurately represent consistent anatomical boundaries. Image segmentation may be difficult in some regions due to either poor contrast, low slice resolution, or tissue ambiguities. To address this, we present a novel ...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2015.2443978
更新日期:2015-12-01 00:00:00
abstract::Identification of objective criteria to correctly diagnose ectatic diseases of the cornea or to detect early stages of corneal ectasia is of great interest in ophthalmology and optometry. Metrics for diagnosis typically employed are curvature maps (axial/sagittal, tangential); elevation map of the anterior surface of ...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2018.2836304
更新日期:2018-11-01 00:00:00
abstract::This paper describes several methods for magnetic resonance angiography that create projection images based solely on flowing blood. To both remove static tissue from the image and generate signals from blood, two classes of methods considered are temporal subtraction and cancelling excitation. Temporal subtraction, a...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.1986.4307763
更新日期:1986-01-01 00:00:00
abstract::During the last two decades, various Doppler methods have been successfully used to screen patients with significant cerebral and peripheral vascular disease. In general terms, the principal advantages of Doppler ultrasound techniques in the evaluation of atherosclerotic lesions are that they: 1) are noninvasive, 2) a...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.1982.4307550
更新日期:1982-01-01 00:00:00
abstract::Three-dimensional Fourier transform (3-DFT) magnetic resonance imaging (MRI) offers advantages in terms of signal-to-noise (S/N) per unit of time for the case where a large number of slices is desired. This advantage is enhanced when the relaxation time, T(1 ), is short. Because time limitations in 3-DFT imaging force...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.97588
更新日期:1991-01-01 00:00:00
abstract::The response characteristics of two tomographic systems were compared for imaging of positron emitters: a) a SPECT system with a 3/8 in crystal and 511 keV detector shielding, equipped with a specially designed 511 keV collimator, and b) a PET V system using coincidence detection. SPECT transverse plane resolution was...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.1986.4307776
更新日期:1986-01-01 00:00:00
abstract::In picture archiving and communications systems (PACS), images need to be displayed in standardized ways for radiologists' interpretations. However, for most radiographs acquired via computed radiography (CR), digital radiography (DR), or digitized films, the image orientation is undetermined because of the variations...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/tmi.2006.880677
更新日期:2006-10-01 00:00:00
abstract::Myocardial tissue characterization using ultrasound is a growing area of investigation which attempts to evaluate the structure of the myocardium by analysis of ultrasound signals. Our laboratory has been exploring the use of texture analysis for the determination of myocardial tissue properties from two-dimensional e...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.1985.4307721
更新日期:1985-01-01 00:00:00
abstract::Computed ultrasound tomography in echo mode (CUTE) is a promising ultrasound (US) based multi-modal technique that allows to image the spatial distribution of speed of sound (SoS) inside tissue using hand-held pulse-echo US. It is based on measuring the phase shift of echoes when detected under varying steering angles...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2020.3029286
更新日期:2020-10-07 00:00:00
abstract::Alzheimer's disease (AD) is a serious neurodegenerative condition that affects millions of individuals across the world. As the average age of individuals in the United States and the world increases, the prevalence of AD will continue to grow. To address this public health problem, the research community has develope...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2019.2958943
更新日期:2020-06-01 00:00:00
abstract::A new reconstruction method, coined MIRAGE, is presented for accurate, fast, and robust parameter mapping of multiple-echo gradient-echo (MEGE) imaging, the basis sequence of novel quantitative magnetic resonance imaging techniques such as water content and susceptibility mapping. Assuming that the temporal signal can...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2017.2771504
更新日期:2018-02-01 00:00:00
abstract::We propose a new method for deformable registration of pre-operative and post-recurrence brain MR scans of glioma patients. Performing this type of intra-subject registration is challenging as tumor, resection, recurrence, and edema cause large deformations, missing correspondences, and inconsistent intensity profiles...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2013.2293478
更新日期:2014-03-01 00:00:00
abstract::The accurate determination of the local impulse response and the covariance in voxels from penalized maximum likelihood reconstructed images requires performing reconstructions from many noise realizations of the projection data. As this is usually a very time-consuming process, efficient analytical approximations bas...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2015.2410342
更新日期:2015-09-01 00:00:00
abstract::In this paper we propose a framework for using duplex Doppler ultrasound systems. These type of systems need to interleave the acquisition and display of a B-mode image and of the pulsed Doppler spectrogram. In a recent study (Richy , 2013), we have shown that compressed sensing-based reconstruction of Doppler signal ...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2015.2504240
更新日期:2016-04-01 00:00:00
abstract::Most strain imaging techniques follow a pipeline strategy: in the first step, tissue displacement is estimated from radio-frequency (RF) frames, and in the second step, a spatial derivative operation is applied. There are two main issues that arise from this framework. First, the gradient operation amplifies noise, an...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2017.2685522
更新日期:2017-06-01 00:00:00
abstract::Deep learning is becoming an indispensable tool for various tasks in science and engineering. A critical step in constructing a reliable deep learning model is the selection of a loss function, which measures the discrepancy between the network prediction and the ground truth. While a variety of loss functions have be...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2020.3031913
更新日期:2020-10-19 00:00:00
abstract::While magnetic particle imaging (MPI) constitutes a novel biomedical imaging technique for tracking superparamagnetic nanoparticles in vivo, unlike magnetic resonance imaging (MRI), it cannot provide anatomical background information. Until now these two modalities have been performed in separate scanners and image co...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2014.2327515
更新日期:2014-10-01 00:00:00